Post Buy Requirement

Our Products

Our product range contains a wide range of Harmonic Indicator, counter measurement, Heater System Burnout Detector, Power Genius PRO and Harmonics Indicator

Alarm Annunciator

Alarm Annunciatoris a centralised model, which gives audio visual signals for the faulty processes. Latest models of annunciators are based upon microprocessor or micro controller circuitry, which ensures the maximum reliability as well as enhanced wide ranges of features and functionalities. We Offer Alarm Annunciator according to customers flexibility and needs.

Alarm Annunciators consist of a power supply unit SMPS, a programming unit CPU and other connections including fault contacts and facial display units. The blinking windows are generally acrylics, which are enlightened byLEDwith very low power consumption.

FEATURES

  • It provides high safety integrity for critical alarm applications
  • With a wide range of three window sizes your exact requirements can be matched
  • User selectable operating alarm sequences (Auto Reset, Manual Reset, FIFO & Ring Back sequence)
  • Customised sequences also given
  • User selectable alarm contacts (NC/NO)
  • Front door access and easy removal of legend inscription (Less than 0.2 VA)
  • High bright multicolour LEDs for Facia
  • Manual push button for Test, ACK & Reset function
  • Optional status monitoring indication
  • Optional RS485/RJ45 communication output for SCADA application
  • Optional dual indication in single window
  • Powder coated MS Enclosures

APPLICATION

Electrical control panel, power generation stationand process Automation

View Complete Details

Digital Voltmeter

digital voltmeter vlt 9053 new approach to develop panel metering in sub stations, distribution panels , genset panels, pumps, motors, compressors and individual equipments, control panels and test benches and much more.

benefits

  • microcontroller based design
  • true rms measurement
  • 3 voltage readings in a single meter
  • single meter for 3 phase star & delta (lt/ ht) application
  • pt primary voltage & secondary voltage (415v/110v) selection through keypad
  • 4 digit 0.5" 7 segment red led
  • displays phase & line voltages
  • r, y, b, ry, yb, br voltage display selection by push button
  • phase indication by leds
  • accuracy +/-1% on reading
  • accuracy 0.5% on reading(optional)
  • voltage resolution (0.01kv for ht & 1v for lt)
  • auxiliary supply 90-270v ac/dc
  • 96(h) x 96(w) x 45(d) mm
  • poly carbonate enclosure
  • panel mounting
.
View Complete Details

Digital Ammeter

Digital Ammeter AMM 9043 new approach to develop panel metering in sub stations, Distribution panels , Genset Panels, Pumps, Motors, Compressors and Individual Equipments, Control panels and Test benches and much more.

Benefits

  • Microcontroller based design
  • True RMS measurement
  • 3 phase Current readings in a single meter
  • CT Primary current & secondary current (5A/1A) selection through keypad
  • Accurate under Harmonic conditions
  • 4 digit 0.5" 7 segment Red LED
  • R, Y, B current display selection by push button
  • Phase indication by LEDs
  • Accuracy +/-1% on reading +1 LSD
  • Accuracy +/-0.5 % on reading +1 LSD (Optional)
  • Current Resolution (1A up to 1000A / 0.01KA above 1000A)
  • Auxiliary supply 90-270V AC/DC
  • 96(H) x 96(W) x 45(D) mm
  • Poly carbonate enclosure
  • Panel Mounting
View Complete Details

Harmonic Indicator

HAR 9000is a new approach in harmonic analysis which measures the value of current and voltage harmonics. THD in & of voltage and Current.Individual Harmonic Amplitude in % of voltage and current spectrum.Displays up to 31st harmonic and Total demand di stortion (TDD) display. Continuous harmonic monitoring Communication port.

features

  • Display of True RMS voltage and current
  • THD in % of voltage
  • THD in % of current
  • Individual Harmonic Amplitude and in % of voltage spectrum
  • Individual Harmonic Amplitude and in % of current spectrum
  • Displays up to 31st harmonic
  • Total demand distortion (TDD) display
  • Continuous harmonic monitoring
  • Communication port RS485 with MODBUS-RTU to PC
  • Derating of Transformer, cables, breakers can be decided.
  • Effects of the mitigating devices / filters can be quantified
  • Voltage: 100 - 520V AC L-L for LT 30 - 140V AC L-L for HT
  • Current: 5A / 1A AC
  • Accuracy : +1% +1 LSD for magnitude +2% over full scale for % values (for loads more than 20%)
View Complete Details

Power Factor Controller

ICD Power Factor Controller PFC 9070 is micro-controller based and assembled in 144 x 144 mm ABS plastic enclosure for flush mounting. It operates with voltage and current signals from suitable voltage and current transformers. It measures power factor and also the reactive power consumption of the load. With appropriate user program fed, it gives relay output signals to switch IN/OUT capacitor banks by contactors in a sequential manner to achieve the preset PF.

Features
  • Measurement of PF for all 4 quadrants
  • Identification of the power of connected
  • capacitor either automatically or through user program
  • Optimum usage of capacitor banks through cyclic switching
  • Control either in Auto / Manual
  • Suitable for switching in / out capacitor through thyristor module / Contactor
  • Adjustable connection delay and reconnecting delay for banks to suit the load changes
  • Alarm against Over Voltage, Under Voltage, Over Current, Over Compensation, Under Compensation & Step fault
  • THD Measurement and alarm (optional)
  • Alarm for insufficient measurement current
  • Disconnection of particular step for step problem
  • Disconnection of capacitor bank for excessive harmonics
  • Connection of permanent capacitor value in addition to the measured required power E.g: for compensation of a transformer
  • Separate PF setting for EB/DG (optional)
  • External potential free digital input provided to select EB/DG Setting (optional)
  • RS485 Port for communication with MODBUS RTU protocol (optional)

View Complete Details

Temperature Scanner

ICD Temperature Scanner Model No. SCN525 is capable to measure and control the Temperature upto 16 points. It accepts temperature sensors like RTDs, Thermocouple, mV and mA signals from Transmitters. The Scanner is completely user programmable like High/Low set point control action, Auto/Manual operation, Channel grouping, Hold, Pause etc.

The Scanner is a single board construction with the latest integrated circuit, so as to reduce component counts. Fast A/D converter is used for quick refreshing of all the channels input and output. Digital Zero / Span calibration eliminates trim pot adjustments and settings are made through key pad.

Maximum 4 relay outputs are given for Alarm & Trip controls. Channel grouping optional and control modes are programmable.The Scanner scans all the channels continuously on the background while displaying and generates the Alarm & Trip outputs after comparison with respective settings.

The Scanner has two modes of operation:1. Operator Level and, 2. Superior Level

The operator level permits channel display selection in Auto, Manual, Hold mode and Alarm acknowledge. Whereas supervisory level access, Alarm & Trip setting, group configuration, output delay adjustments, channel pause function, scan time etc.

Optionally, external relay box containing Max. 32 relays can be connected through serial link. The scanner is housed in 96 x 192 x 250 mm flush mounting enclosure.

FEATURES

  • Microcontroller based design
  • Accepts RTD, Thermocouple, mV, mA
  • High Accuracy with software linearisation
  • Multiplexing by Analog switches
  • Channel pause & Hold facility
  • Two set points per channel
  • Over range & Open sensor indication
  • Programmable scan time, set point & channel pause
  • Alarm and Trip indication for each channel
  • Error compensation at site
  • Digital calibration for each channel
  • Optional : PC Interface
  • Optional : Relay output - Max.32 through external relay unit
  • Compact in size / Modular construction
  • EERAM storage, no battery required
  • Protection against EMI/Stray noise
  • Built-in Watchdog Timer
  • 2 or 4 Relay output

APPLICATION

  • Winding temperature monitoring of High Rating Motors, PowerGenerators and transformers
  • Various parts of Engine bed, Ball bearings, Water and Steam pipe of boilers
  • Various points in Sugar mills, Food processing, Chemical, Cement, Fertilizer & Pharmaceutical Industries
View Complete Details

Counter Measurement

CNT 200 is a new approach to Process Measurement integrating Control I/Os which Counts of any motor or any devices which accepts input from Proximity, External Pulse inputs, photo electric switch. Our counter which acts as a controller device with respect to the input by providing two number of Relay's. EERAM is provided to store the Setpoints and constants.

View Complete Details

Digital Timer

4,500 - 6,500 /Piece Get Latest Price
  • Type Digital Timers
  • Brand Name ICD
  • Display Type Digital
  • Country of Origin India
features
  • microcontroller based design
  • high accuracy
  • individual and multifunction
  • 5 digit display
  • two relays output
  • flexible design
  • flexible control input
  • non erasable memory storage
View Complete Details

Display Unit

ICD Microprocessor based Display unit which displays Value of Voltage, Current, Frequency, Temperature, Pressure, Flow. etc. Our display unit can be assembled from the range of 2' inch display to 12' inch size. These displays can be used as a monitoring cum controlling devices.

Features
  • Long life Super Bright LEDs
  • Single Line / Multi Line
  • Display Size 2 / 4 / 6 / 12
  • Day light visibility
  • Alpha Numeric characters (optional)
  • Rs - 485 Communication(optional)
  • Relay Output(Optional)

Applications
  • Monitors Process variable seen at a longer distance
  • Monitor Production / Machine stroke/Assembly lines / Conveyors
  • Improves process Efficiency Productivity and Motivate employee
View Complete Details

Zero Speed Switch

Zero Speed Switch is designed to detect the stalling of motors due to over load or chain delinking and conveyor belt stoppage. It is designed for accepting I/P Signal from non contact proximity pickup, Magnetic Pickup, Potential free NO Contact for DC/AC signal from Tacho generators. A Sensing Wheel with projection mounted on the shaft of the motor with proximity pickup or Magnetic reed switch gives a train of pulses. The signal is given to an electronic circuit which senses the duration between the pulses. If the interval between pulses is more than the set time and if it continues more than the time delay set, a relay de-energises. The circuit consists of signal conditioners, time interval detectors, power supply and Relay Circuit. Total system is housed in a compact dust proof ABS Plastic DIN Rail mounting Case.

View Complete Details

Sequential Timer

9,000 - 18,000 /Piece Get Latest Price

a sequential timer, also referred to as a sequencer or sequence timer, will energize and de-energize multiple outputs over a period of time. the amount of time before each output is energized and the amount of time the output remains energized is variable. the outputs may be energized one at a time in order. for mechanical relay applications, the relay contacts of the first relay will close. then, after a set amount of time, the first relay's contacts will open and the second relay's contacts will close.

features

  • microcontroller based design
  • high accuracy
  • individual and multifunction
  • 5 digit display
  • two relays output
  • flexible design
  • flexible control input
  • non erasable memory storage
View Complete Details

Signal Isolator

Signal Isolatoris a versatile for LT/HT application. It measures basic electrical quantity DC Voltage(75 mV /200 mV /1V /10V), DC Current(0-20mA/4-20mA), Resistance(500 Ohm, 1kOhm, 2kOhm, 5kOhm, 10kOhm) as input and convert it as Current(0-20mA, 4-20mA), Voltage(0-1V DC, 0-10V DC).The number of outputs provided two.

View Complete Details

Rpm Indicator

6,500 - 12,500 /No Get Latest Price
  • Min. Order (MOQ) 1 No
  • Type Rpm Indicators
  • Resolution 0.1 Rpm For 4.0 To 999.9 Rpm, 1 Rpm Above 1000 Rpm
  • Warranty 1yr
  • Country of Origin India

CNR230 is a new approach to Process Measurement integrating Control I/Os which Measures RPM value of any motors or Devices which accepts input from Proximity, Photo Electric, Magnetic Pickup, Potential Free Contact Limit, Pulse Inputs. Our Process Indicator which acts as a controller device with respect to the input by providing two number of Relay's. EERAM is provided to store the Setpoints and constants. Our Device can measure the RPM ranges from 0 to 99999 RPM with Accuracy of 0.01%.

View Complete Details

Process Indicator

UPC 5200 is a new approach to Process Measurement integrating Control I/Os which Measures input from Temperature(J, K, T, R, S, RTD, mA/Volt), Current(4-20 mA / 0-20 mA), Volt(0-10v / 1-5v). Our Process Indicator which acts as a controller device with respect to the input by providing two number of Relay's.

View Complete Details

Thyristor Capacitor Switching Module

Thyristor capacitor switching module is designed to use for Real time power factor correction. It consist Dynamic switching Module (DSM- Electronic circuitry housed in Din rail mount enclosure) and Thyristor power stack (TSM 2 no Thyristors mounted on suitable heat sink). DSM is a microcontroller based design which generates trigger pulse to TPS and ensures the zero voltage switching of thyristor to achieve the transient free operation. DSM is common for all rating thyristor capacitor switching module and TSM varies according to the capacitor bank KVAr rating. Both DSM and TPS are interconnected with simple wiring.

Features

  • Transient free switching.
  • Real time PF correction is possible.
  • Suitable to use with tuned and detuned filter reactor.
  • Relay provided for cooling fan to activate the fan only at bank ON
  • Over temperature Protection.
  • Electronic circuitry is housed in the enclosure, so that suitable to work in dust environment.
View Complete Details

Power Factor Correction Panel

Majority of the loads in the industries are highly inductive in nature such as induction motors, welding equipments, arc furnaces andfluorescent lightings. There may be a few resistive loads for heaters and incandescent bulbs. Very rarely industries may have capacitive loads such as synchronous motors. Net industrial load is highly inductive causing a lagging power factor. If this poor power factor is left uncorrected, the industry will require a high maximum demand fromElectricity Board and also will suffer a penalty for poor power factor. These two factors of high kVA demand and penalty for poor factor will inflate the monthly Electricity Bill. Since Power Factor can be corrected to near unity there can be huge saving from the Electricity Bills. Standard practice is to connect power capacitors in the electrical network at appropriate places to compensate the inductive nature of the load.

FEATURES

  • 1 and 3 Welding Equipments
  • Wind Turbine Generators
  • Robotic Machinery
  • Steel Rolling Mills
  • Elevators, Cranes, Presses
  • IT Companies, Hospitals
  • Water Treatment Plants
  • Air-conditioning etc
View Complete Details

Thyristor Power Regulators

10,000 - 15,000 /Piece Get Latest Price
  • Type Thyristor Power Regulator
  • Material Aluminium, Brass, Fiberglass, Frp, Glass, Plastic
  • Application Power Use
  • Color Creamy, Golden, Green, Light Green, Metallic, Off White, Shiny Silver, Silver, Sky Blue
  • Condition New, Old
  • Operating Temperature -25 +85deg C
  • Feature Accurate Reading, High Performance, Longer Service Life, Robust Construction
  • Current Type AC, DC
  • Automation Grade Manual, Semi Automatic
HP 802 Small Combo Pack Multi Color Ink Cartridge
View Complete Details

DC Voltmeter

  • Type Dc Voltmeter
  • Condition New
  • Warranty 1yr
  • Country of Origin India
  • Brand Name ICD
  • Display Type LED
  • Dimension 96x96
View Complete Details

Heater System Burnout Detector

ICD offers heater system monitoring and burnout detection. This product is designed to monitor status of the heater system with 3 phase star or delta connected loads. This instrument measure and monitors voltage, current, power and energy through external CTs and voltage detection; it can operate with 3 CTs or 2 CTs with true RMS measurement, CT ratio is settable in the meter itself. Under current setting will be given to study heater status and it will announce the heater burnout detection. This unit also shows the thyristor short circuit failure or open circuit failure.

This instrument displays voltage, current, power and energy by digital measurement and finds the heater burnout status and provide alarm through an external relay output.

Main Functions

  • Heater burnout alarm
  • Heater layer short circuit alarm oncrossing limit
  • Power device short circuit detect
  • Power device open circuit detect
  • Display of all electrical quantities
  • Heater useful run hour

Features

  • Ensure best quality product
  • Avoid scrap and raw material wastage
  • Automatic human intervention
  • Monitoring unbalance heating
  • Monitoring a group of heater together in an enclosure
  • Contribute preventive maintenance
View Complete Details

Flow Totalizer

10,000 /Piece Get Latest Price
  • Size Multisizes
  • Type Flow Totalizers
  • Material Aluminum, Brass, Copper, Plastic
  • Application Industrial, Residential
  • Color Brown, Green, Grey, Maroon, Red, Yellow
  • Feature Accuracy, Digital Water Meter Display, Lorawan Compatible, Spiral Water Meter
  • Voltage 110V, 220V, 230V, 380V, 440V
  • Automatic Grade Automatic, Fully Automatic
  • Driven Type Electric
  • Warranty 1 Year
  • Display Local
HP 802 Small Combo Pack Multi Color Ink Cartridge
View Complete Details

Power Genius PRO

PCM 9505 is a new approach to Energy Management Systems and Energy Billing Systems integrating Control IOs which enable Process Integration, Breaker Status Detection, Alarm output, Basic Demand control outputs and more, directly integrated within the meter .
View Complete Details

Energy Saver Panels

80,000 /Piece Get Latest Price
  • Type Energy Saver Panels
  • Weight 0.5-1kg, 1-2kg, 2-3kg, 3-4kg
  • Color Black, Gray, White
  • Voltage 110V, 220V, 380V, 440V
  • Condition New, Used
  • Output Type AC Single Phase, AC Three Phase, DC
  • Frequency 50hz, 60hz
  • Feature Auto Cut, Easy Operate, Shocked Proof, Stable Performance, Works In Low Voltage
  • Warrenty 1year, 2years
HP 802 Small Combo Pack Multi Color Ink Cartridge
View Complete Details

AC Voltage Controller

  • Packaging Type Carton Box
  • Overall Weight 200gm
  • Usage Factories, Power Plants, Shopping Malls
  • Specialities Durable
  • Overall Dimension 96x96x80
  • Brand Name ICD
  • Color Brown
  • Voltage 220V
  • Warranty 1 Year
  • Current Type AC
  • Mounting Type Panel

digital three phase ac control relay, microcontroller based design,

settings: over current, under current, individual phase, avg current

.
View Complete Details

Harmonics Indicator

We offer harmonics indicator. Display of true rms voltage and currentthd in % of voltagethd in % of currentindividual harmonic amplitude and in % of voltage spectrumindividual harmonic amplitude and in % of current spectrum
View Complete Details

Harmonics Filter

Any device with non-linear operating characteristics, draw current from the source which does not follow the voltage wave form and introduce wave form distortion in current. These wave form distortion in current are called current harmonics
View Complete Details

Battery Charger Panel

1.10 Lakh /Piece Get Latest Price
  • Type Battery Charger Panel
  • Application Charging, Power Converting
  • Weight 10-20kg, 20-30kg, 30-40kg, 40-50kg
  • Color Black, Brown, Grey
  • Voltage 110V, 220V, 380V, 440V
  • Condition New, Used
  • Power 1-3kw, 3-6kw, 6-9kw, 9-12kw
  • Warranty 1year
HP 802 Small Combo Pack Multi Color Ink Cartridge
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us