Leading Manufacturer, Supplier & Retailer of Advanced Siren Controller, Electric Siren and Electric Motor Siren.

Buzzers

Hooter Cut Out Dimensions: 92 X 92 mm
Input Voltage: 12v, 24/30v, 48/50v, 110v, 220v / 220v AC Or DC (Any One)
Ideal Audible Range: 50 Meters
Tone: Multitone / Single Tone

  • Buzzers with Volume Control
  • Buzzers with Tone Control
  • Buzzers with acknowledgement switch.
View Complete Details

Emergency Lights

Emergency Light with Exit Sign

Features:-

  • Double Beam
  • Metal Halide bulb / LED
  • 7.5AH Exide Battery
  • Upto 1 Hour backup
  • Automatic ON in case of Power Failure
  • Battery over, under Charge Protection.
  • With Radium exit sign
View Complete Details

Advanced Siren Controller

Our Advanced Siren Controller is based on OISD-177 safety standard &Codes of Practices for Emergency Response and Disaster Management Plan (ERDMP)Petroleum And Natural Gas Regulatory BoardG.S.R. 39(E)

AdvancedSirenController

14.2.5.9 Siren Codes.

The Emergency siren/s should be located suitably to cover the whole area with the operational control within the installation. These should be tested at least once in a week to keep them in working condition.

  1. The Emergency siren/s should be located suitably to cover the whole area with the operational control within the installation. These should be tested at least once in a week to keep them in working condition.
  2. Emergency siren code should be as follows, namely:
    1. Emergency Level-I: A wailing siren for two minutes.
    2. Emergency Level-II and III: Same type of siren as in case of Level I and II but the same will be sounded for three times at the interval ofoneminutes i.e.( wailing siren 2min + gap 1 min + wailing siren 2min + gap 1min + wailing siren 2min) total duration of Disaster siren to be eight minutes.
    3. ALL CLEAR: Straight run siren for two minutes.
    4. TEST: Straight run siren for two minutes at frequency at least once a week
    5. Public address system should be provided with message.

OISD-STD-117. Control panel shall have different patterns codes as under:

  • FIRE: For fire situation, the siren shall be wailing sound for 2 minutes.
  • DISASTER: For disaster situation, the siren shall be wailing sound for 2 minutes repeated thrice with a gap of 10 seconds.
  • ALL CLEAR: For all clear situation, the siren shall be straight run sound for 2 minutes.
  • TEST SIREN: For testing, the siren shall be straight run sound for 2 minutes.

We can also customize this as per customer requirements.

Classification of emergencies.

Emergencies can be categorized into three broad levels on the basis of seriousness and response requirements, namely:-

  1. Level 1: This is an emergency or an incident which
  1. can be effectively and safely managed, and contained within the site, location or installation by the available resources;
  2. has no impact outside the site, location or installation.
  1. Level 2 :This is an emergency or an incident which
  1. cannot be effectively and safely managed or contained at the location or installation by available resource and additional support is alerted or required;
  2. is having or has the potential to have an effect beyond the site, location or installation and where external support of mutual aid partner may be involved;
  3. is likely to be danger to life, the environment or to industrialassets or reputation.
  1. Level 3: This is an emergency or an incident with off-site impact which could be catastrophic and is likely to affect the population, property and environment inside and outside the installation, and management and control is done by district administration. Although the Level-III emergency falls under the purview of District Authority but till they step in, it should be responsibility of the unit to manage the emergency.

Note:Level-I and Level-II shall normally be grouped as onsite emergency and Level-III as off-site emergency.

View Complete Details

Industrial Sirens

Housing:M. S. Powder Coated, Circuit Size:225mm X 200mm (Varies as per Voltage), Tone:Siren Dual Tone, Range:300-400 Meters (Single Speaker), Speaker:P.A. Type, Sound Output:80-85 dB, Input Voltage:2201104824 V AC or 1224 V DC (Any One).
View Complete Details

Electric Siren

We offer complete range of Electric Siren which are used for fire alarm or in case of emergency alerts. Electric Motor Siren are also called as air raid siren. Electric Siren is basic and integral part of any emergency alert system.
View Complete Details

Electric Motor Siren

We offer complete range ofElectric Siren which are used forfire alarm or in case ofemergency alerts.Electric Motor Siren are also called as air raid siren.Electric Siren is basic and integral part of anyemergency alert system.

Model Number Voltage Ideal Audible Range
PC-MS-1S-050 12, 24, 110, 220/240V AC 0.5 Kms
PC-MS-1S-100 12, 24, 110, 220/240V AC 1.0 Kms
PC-MS-1S-200 12, 24, 110, 220/240V AC 2 Kms
PC-MS-1D-200 12, 24, 110, 220/240V AC 2 Kms
PC-MS-1D-325 12, 24, 110, 220/240V AC 3.25 Kms
View Complete Details

Strobe Light

  • Input Voltage 12V, 24V, 110V & 220V
  • colors Red, Amber, Green & Blue

We offer High Intensity LED Strobe and Flashing Lights suitable for Outdoor Installations & various applications. OurStrobe Lights are made with best quality LED & ABS top cover for better life.

  • Chimney Lights (Aircraft warning lights for chimneys)
  • Crane Strobe Lights (For overhead crane warning)
  • Obstruction Lights
View Complete Details

Flasher Electronic Hooter

  • Input Voltage 12V, 24V, 110V & 220V
  • Sound Output 85-90 dB (approximate)

This is an Audio Visual Alarm, useful for situations where there is requirement for both Audio & Visual Alerts. Benefit of warning led light is that in case machine operator is away, he can still get alerted with Flashing warning light.