Related Category
Business Type
Used in plastic and cable industries, ASIAN Temperature Of Deflection Under Load Apparatus under Load consists of a specimen support, an immersion bath, a set of weights under deflection -measuring device. The specimen support consists of a two parallel metal supports having rounded edges fixed at a specified more...
The unit consists of 3 identical cylindrical conductors in respect of geometry. One end of these is heated electrically while there are small capacity tanks acting as heat sinks at the other end. The unit consists of a heat pipe, a copper pipe & stainless steel pipe. Thermocouples are embedded along the lengt more...
Infrared radiation delivers warmth to the human body. The warmth of the irradiation increases blood flow in the irradiated skin tissues. Increased temperature also improves local metabolism. Improved blood flow brings more oxygen and nutrients to the treated area and encourages the speed of healing. Warm infr more...
Get Quotes from Verified Suppliers
- Two Phase Heat Transfer Apparatus - For Educational Training - Heat Transfer Lab more...
The apparatus consists of a. m. s. shell, in which copper tubes are fitted. The baffle in the end box makes the tubes arrangement two-pass type. The cold fluid, i.e. air enters the shell and flows over the tubes. Hot fluid is hot water, which is obtained from a geyser and flows through the tubes. 25% cut baff more...
The apparatus consists of a nichrome wire immersed in water. The Nichrome wire is heated by passing current through it. Input to the nichrome wire is controlled by dimmer stat. As one goes on increasing wire input current, at critical heat flux, the wire brakes which is measured on meter. We can visulise natu more...
Get Quotes from Verified Suppliers
Critical Heat Flux Apparatus works as a demonstrative tool to present the method of pool boiling. Our flux apparatus has a test wire enclosed by water of persistent temperature. The surface temperature of the test wire is heated by passing current through it. Due to the temperature different temperatures in t more...
The apparatus consists of a small test sphere. This sphere is heated by a hot bath, till the steady state is reached and then it is coolled in air or water oil. During both, heating and cooling of sphere, temperature of sphere is a function of time and hence, it is a unsteady state of heat transfer process. T more...
The ‘J P T I’ unit consists of a cylindrical glass container containing distilled water. Heating surface is in the form of a Nichrome heating wire completely submerged in the water. Thermometers are provided to measure the temperature of water in the container. Pool boiling phenomenon can be studied at at more...
The nichrome wire is heated by passing current through it. Input to nichrome wire is controlled by a dimmer stat. As one goes on increasing wire input current increases and at critical heat flux the wire brakes, which is measured on the meter. A magnifying glass & a lamp is provided to visualize natural conve more...
Metal box, 230 x 75 x 75 mm, with sliding glass front and two detachable glass chimneys, with one candle holder under left chimney. Supplied without candles. Spark in mm : 25, 50, 75, 100 more...
Product Code: EKE 2302 Heat pipe is an interesting device, which is used to transfer heat from one location to another. The apparatus consists of three pipes, viz. A heat pipe, copper pipe and stainless steel pipe. Ail the pipes have same physical dimensions. Copper and stainless steel pipes serve the purpose more...
The HDT/VSP instrument is used for determining the deflection temperature limit for specific application and comparing the heat softening characteristics of thermoplastic material at a constant load in oil upto 300 Deg. C o .c Plastic materials being heat sensitive in nature has a lot of bearing on its therma more...
The Specific Heat of nanofluids decreases as nanoparticle concentration increases. The specific Heat of nanofluids increases with temperature. The Specific Heat of nanofluids decreases as nanoparticle concentration increases. The specific Heat of nanofluids increases with temperature. Thus future research are more...
The ‘J P T I’ unit consists of a cylindrical glass container containing distilled water. Heating surface is in the form of a Nichrome heating wire completely submerged in the water. Thermometer is provided to measure the temperature of water in the container, variac is provided to supply electrical input more...
The apparatus comprises a thick brass calorimeter approximately 90x65 mm. diameter, a bung with steam inlet and outlet tubes, a felt cover, and a 1100 cm3 tinplate boiler with bung to take the steam tube which a connects to the calorimeter. Â Â more...
Range of Experiments to be Carried Out • To study the temperature distribution along the length of a pin fin in natural & forced convection • To calculate Gr, Pr & Nu number in natural conviction • Calculate Re, Pr & Nu number in forced conviction • Calculate the value of m & obtain the temperature at more...
The apparatus comprises a thick brass calorimeter approximately 90x65 mm. diameter, a bung with steam inlet and outlet tubes, a felt cover, and a 1100 cm3 tinplate boiler with bung to take the steam tube which a connects to the calorimeter. Â Â more...
The apparatus consists housing the test heater and heater coil for initial heating of water. This heating coil is directly connected to mains (Heater) and the Test Heater (Nichrome Wire) is connected also to mains via a dimmer stat and a voltmeter, to read the voltage. A micro controller based peak detector h more...
This equipment is required to determine the heat of hydration of cement as expressed in calories per gram. The Euipment comprises of the following :  A wide mounted double walled vacuum flask with a stop cock 38 mm & a insulating container for the flask A Beckman thermometer (Range 5° C )held tightly by th more...
We are offering heat distoration temperature apparatus. more...
We are listed among the most genuine and reliable Manufacturers, Exporters and Suppliers of Critical Heat Flux Apparatus . The offered Critical Heat Flux Apparatus is fabricated using high grade and excellent raw material, sourced from renowned vendors in the industry. We stringently examine the Critical Heat more...
Heat of Hydration apparatus is used for determining heat of hydration of cements by measuring difference between heat of solution of dry cement and heat of solution of a separate sample partially hydrated for 7 days & 28 days. Constant-speed stirrer maintains uniform temperature throughout liquid and supp more...