PM 2.5 Size Separator : Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR
Leak Test : Internal & External Leak check feature for accurate sampling.
Bar Press Sensor : Range 600 to 800 mm Hg. Resolution, 1 mm Hg
Feature : Durable, Fine Finished
PM 2.5 Size Separator : Separate set of inlet assembly with EPA PM 2.5 WINS Impactor
Dust Instruments Measurement : Pm2.5 & Pm10
When it comes to innovation in Ambient Air Sampling technology, Instrumex has delivered yet again! The most common hassle faced by Consultants in order to comply with the CPCB norms for Ambient Air Sampling - was using two separate instruments for measurement of PM2.5 & PM10 more...
Instrumex Respirable Dust Sampler is a versatile dust sampler that is based on a design standardized by CPCB for collection of PM10 & Totoal Suspended Particulates (TSPM) in ambient air and also simultaneously samples the particulates having aerodynamic diameter less than 10 more...
Features : High collection efficiency from 5 to >25,000nm, No particle bounce
The Series 110 Sequential Spot Sampler instrument enables affordable, time-resolved characterization of particulate chemical composition at multiple locations. It provides an uninterrupted collection of particulate matter (PM) as concentrated dry deposits into small sample wells.more...
Feature : Brushless regenerative blower with very little noise., Heavy duty Induction motor fitted in blower requires no maintenance.
APM 460 DXNL is one of the most advanced PM10 samplers being manufactured in India. It is based on CSIR NEERI technology and is the only PM 10 sampler in India that conforms to BIS 5182 (Part 23): 2006 Automatic flow controller and auto shut off In all previous models of particulmore...
Features : Lockable top cover and gaseous attachment., Electromagnetic Interference (EMI) to TVs totally eliminated
The APM 460 NL uses an IMPORTED brushless, continuous rated induction motor driven blower to significantly reduce equipment downtime, maintenance efforts and inconvenience to community. This new improved PM 10 sampler avoids problems arising due to frequent brush wear and limitedmore...
The APM 460 sampler uses an improved cyclone with sharper cutoff (D50 at 10 microns) to separate the coarser particulates from the air stream before filtering it on the glass microfibre filter. By using the APM 460, measurement of Respirable Particulate Matter can be done accuratmore...
We are offering respirable dust sampler. Apm 460 bl is respirable dust sampler also called as pm 10 sampler is used for monitoring pm 10 in ambient air. more...
Compact, light weight, battery operated personal sampler with an in-built cyclone system to monitor both total air borne dust as well as the respirable fraction of dust. This is the most ideal instrument to monitor the health risk of workers due to dust exposure in the shop floormore...
Factory Act 1948 as amended in 86-87 clearly lays down a requirement of regular scientific monitoring of workers’ exposure for air borne dust and other pollutants. Workers’ exposure measured in terms of Total Suspended Particulate Matter does not indicate its criticality in tmore...
The APM 154 system is a manual method for sampling fine particles (PM2.5 fraction) and is based on impactor designs standardized by US-EPA for ambient air quality monitoring. Ambient air enters the APM 154 series samplers system through an omni-directional inlet designed to provimore...
Particle Size : Up To 10 Micron Collected On Filter And SPM Bigger Than 10 Micron Collected In A Separate Collector Cup Blower Continuous Duty Blower With Brushless Blower Recommended Filter GF/A(8" X 10") For Common Use,
Suspended Particles Matter( SPM) which is defined as particles less that 100 microns & Respirable Suspended Particle less than 10 microns have emerged as the most critical among all the criteria air pollutants & is caused by number of sources like Large, medium & small-scale indumore...
technical specifications:- flow rate :- 0.9 – 1.4 m3 /min free flow particle size :- particles of 10 microns & below collected on filter paper holder. Spm bigger than 10 microns collected in a separate sampling bottle under the cyclone. sampling time :- 28 hours (maximum) samplmore...
specifications: battery operated pump for a full of 8 hrs. rechargeable maintenance free battery provision for system to operate for the main also suction pump: diaphragm type. sampling rate : 0.5 – 1lpm rota meter: 0-3 lpm wit needle valves to control flow. digital timer : 3more...
Size (HxWxL): : 30.5 x 14 x 24 inches (78 x 36 x 60 cm)
Operational Temperatures: : 0°C to 50°C
Weight: : Dry, less battery - 76 lbs (35 kg)
Multi-function Sampler is based on the industry-leading 6712 controller. Avalanche provides the advanced control, data logging, and communication features of the 6712, combined with on-the-go cooling from either AC power or a 12-volt deep cycle battery. Bottle configurations inclmore...
combo kdm global sampler we have produced and supplied the highest quality combination sampler for the cement industry from the day of our founding. for applications involving measurement and monitoring of air pollution, the combination sampler is employed in the cement industry.more...
Timer : 24 Hr Programmable timer, number of required intervals can be programmed
Flo Rate : 0.8 to 1.8 m3/min
Blower: : Continues duty blower with brushless Motor
Recommended filter : GF/A (8” X 10”) for common use, EPM 2000 for Special Research or equivalent
Particle Size : Down to 1.6 micron depending upon Filter used
Time Record : 0 to 99999.99 hrs. Time totalizer records the running time in hours
he high volume air sampler collects suspended particulates on large filter paper The name high volume is appropriate because the sampling flow rate has a high level of 20 to 60 standard cubic feet per minute (SCFM). Because of the high flow rate, large quantities of particles ranmore...
Ambient Fine Dust Sampler is designed to measure Ambient Air Pollutants for PM10 PM2.5 according to the CPCB guidelines. Choice of sampling inlets for PM10 , PM2.5 & TSP Data Storage for Ambient Temperature, Filter Temperature, Barometric Pressure, Real time Flow and Volumetric Fmore...
We are dealing in dust samplers, The Sidekick sampling pump - a favorite with SKC customers. Reliability and simplicity make it a good entry level pump, whilst high build quality, means it won’t let you down. All models offer a wide flow range of 5-3000 mlmin, which means the Smore...
The Sidekick sampling pump - a favorite with SKC customers. Reliability and simplicity make it a good entry level pump, whilst high build quality, means it won’t let you down. All models offer a wide flow range of 5-3000 mlmin, which means the Sidekick is suitable for dust and more...
We are offering respirable dust sampler. Netel's model npm-hvs / r is designed to measure repairable suspended particulate matter in ambient air.it is used for collection of pm10 suspended particulate matter upto small as 0.1 micro size.it also has provision to collect samples ofmore...
Long sampling period simulates work shift, Intrinsically safe, Fully portable with rechargeable battery, Accurate and reliable , DGMS approved. more...
Instantaneous digital read out of dust concentration (No Weighing balance required) Highly sensitive in respirable dust range + 10mgm3 Choice of ranges for measurement, gives greater flexibility Detachable sampling probe suitable for remote or inaccessible sampling Rechargeable bmore...
Instantaneous digital read out of dust concentration (No Weighing balance required), Highly sensitive in respirable dust range + 10mgm3, Highly sensitive in respirable dust range + 10mgm3, Choice of ranges for measurement, gives greater flexibility, Detachable sampling probe suitmore...
Particle size: Below 10 microns collected on filter paper and bigger than 10 Micron will be collected in a separate sampling lid, through Cyclone separator. Flow Rate: 0.9 to 1.4m3/min.. Automatic Sampling: By- 24 Hrs Programmable Timer, Time Record Voltage Stabilizer: Auto shut more...
Get in touch with us for obtaining top quality and accurate Respirable Dust Sampler ! We are a renowned Manufacturer, Supplier and Exporter of Respirable Dust Sampler in Delhi, India. Sturdy built, superb finish, hygienic and cost-effective are the highlights of our Dust Sampler,more...
We have carved a niche as Manufacturer, Exporter and Supplier of Personal Dust Sampler in Delhi, India. Compact in design, battery operated, lightweight, our Dust Sampler comes with an in-built cyclone system not only to monitor total air borne dust as well abuts the respirable fmore...
As air quality measurement norms are going higher and higher day by day, In new air quality standard notified by Govt. of India where measurement of PM10 and PM2.5 dust is required with other pollutants to decide status of air pollution. So far samplers developed in India do not more...
A device that is compact, versatile air sampler for monitoring gaseous and particulate pollutants in ambient air and the work - space environment that analyses inorganic gases such as so2, nox. This instrument is small, light in weight, mounted in a compact aluminum case and is fmore...
We offer a comprehensive range of Respirable Dust Sampler to the clients in national and international markets. These Respirable Dust Samplers are widely used for air quality monitoring. It effectively detects the presence of inorganic gases in the environment. Our clients can avmore...
We are offering respirable dust sampler. sle-rds103 suspended particles matter( spm) which is defined as particles less that 100 microns & respirable suspended particle less than 10 microns have emerged as the most critical among all the criteria air pollutants & is causemore...
We manufacture, export, and supply a supreme range of High Volume Air Sampler across the globe. The quality tested High Volume Air Sampler provided by us conform to guidelines of Central Pollution Control Board. It is used to monitor the air to determine the extent of pollution amore...