Related Category
Business Type
Samplereagent tray ·70 sample position ·70 reagent position ·reagent refrigerated function reaction tray ·90 reusable cuvettes ·automatic blank testing for cuvettes ·colorimetry systemof the pattern of light splitting behind cuvettes ·dismountable, easily replacement ·reaction temperature 37℃, const more...
①. 60 Sample positions. ②. 45 Reagent positions. ③. 120 Reaction cuvettes. ④. 300 Tests Hour. Reaction tray 37℃±0.1℃, with online softare monitor the temperature Reagent tray Continuous 2℃~8℃ cooling within 24 hours Stirring needle Teflon coating to avoid cross contamination Sample needle Liq more...
①. 180 Sample positions. ②. 200 Reagent positions. ③. 160 Reaction cuvettes. ④. 800 Tests Hour 1. Fully automated, Discrete, Random access, STAT priority. 2. Close or open system setting, supported reagents of different brand. 3. Precision sampling pumps, sample step by 0.1 ul, reagent step by0.5 ul 4 more...
①. 60 sample positions. ②. 45 reagent positions. ③. 120 reaction cuvettes. ④. 300 tests hour. sample unit sample settings 60 sample positions, including calibration, quality control and emergency sample volume 2ul ~70ul (0.1ul stepping) sample probe teflon coating probe, with liquid level sensor, with more...
①.120 sample positions ②.90 reagent positions ③.90 reaction cuvettes ④.400 tests hour samplereagent tray ·120 sample position ·90 reagent position ·reagent refrigerated function. more...
.40 sample positions ②.80 reagent positions ③.44 reaction cuvettes ④.200 tests hour reaction tray ·44 reusable cuvettes ·automatic blank testing for cuvettes ·colorimetry system of the pattern of light splitting behind cuvettes ·dismountable, easily replacement ·reaction temperature 37℃, constant more...
①. 49 Sample positions. ②. 56 Reagent positions. ③. 120 Reaction cuvettes. ④. 200 Tests Hour. Reaction tray 37℃±0.1℃, with online softare monitor the temperature Reagent tray Continuous 2℃~8℃ cooling within 24 hours Sample needle Liquid level sensor function, with anti-collision function, rea more...
①. 90 Sample positions. ②. 90 Reagent positions. ③. 120 Reaction cuvettes. ④. 550 Tests Hour. Reaction tray 37℃±0.1℃, with online softare monitor the temperature Reagent tray Continuous 2℃~8℃ cooling within 24 hours Stirring needle Teflon coating to avoid cross contamination Sample needle Liq more...
Get Quotes from Verified Suppliers
①. 180 Sample positions. ②. 200 Reagent positions. ③. 160 Reaction cuvettes. ④. 800 Tests Hour 1. Fully automated, Discrete, Random access, STAT priority. 2. Close or open system setting, supported reagents of different brand. 3. Precision sampling pumps, sample step by 0.1 ul, reagent step by0.5 ul 4 more...
①.40 Sample positions ②.80 Reagent positions ③.44 Reaction cuvettes ④.200 Tests Hour SampleReagent tray ·40 sample position ·80 reagent position ·Reagent refrigerated function Reaction tray ·44 reusable cuvettes ·Automatic blank testing for cuvettes ·Colorimetry system of the pattern of light sp more...