Post Buy Requirement
HE
Noida, Uttar Pradesh, India
Verified Add Review

Electrical Cables & Wires #3733858

3 Core Flat Cable

  • Color Black
  • Feature Crack Free, Durable, High Ductility, High Tensile Strength, Quality Assured
  • Voltage 110V
  • Innner Material Aluminium
  • Length 10-20mtr
  • Load Capacity 1-3kw
  • Thickness 0.5-1mm, 5.5-6mm
  • Size of conductor Size of conductor in mm2

3 Core Flat Submersible Cable, StrandedFlexibleSolid bare annealed 100% electrolytic grade copper conductor, Round Submersible cables can be specially asked for , Conforms to IS:6941990.

View Complete Details

ZHFR Wire

  • Size of conductor Size of conductor
  • Voltages grade Up to 1100 Volts
Single Core Unsheathed (ZHFR), Multi strand 100% Pure annealed Electrolytic copper conductor, ZHFR insulated compound Non-PVC, Bunching of copper in uniform lay & diameter, 100 % Free PVC and eco friendly, Low toxic & corrosive gases.
View Complete Details

Telephone Wire

Range : 0.40.450.50.60.70.80.9 mm dia conductors upto 50 pairs, Solid 100% pure annealed bareTinned electrolytic copper conductor, PVC & PE insulation, Individual Overall shielded with Aluminium tape Polyster backed.
View Complete Details

Industrial Wire

  • Specifications: IS 694/1990
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 0.5 to 400 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: 1
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded Double layer PVC Type A/ FR/ HR/ FR-LSH
  • PVC insulation thickness & tolerance: As per table 2 / 3 / 4 of IS 694
  • Color of PVC insulation: As per purchase required & IS:694-1990, Table No. 7
  • Standard length of wire coil: 90/180/270
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • PVC Sheathed compound for multicore cables: N/A
  • PVC Sheath thickness & tolerance: N/A
  • Color of Sheath: N/A
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
Salient Features

  • Range : 0.5 to 400 Sqmm in Single core cables
  • Multi strand 100% Pure annealed Electrolytic copper conductor
  • FR/FR-LSH insulation conforms to IS:694/1990
  • Bunching of copper in uniform lay & diameter
  • High insulation Resistance
  • Double insulation with ultra thin layer
Application

  • Used in duct, conduit, or Aerial wiring for electric power in Houses, Buildings, Flats, Apartments, Hospitals, Theaters, EducationInstitutions & Factories also used with UPS, Invertor, Battery, control panels etc .
View Complete Details

Telephone Cables

  • Specifications: TEC Specification G/WIR 06/02
  • Range: 0.4/0.45/0.5/0.6/0.7/0.8/0.9 mm dia
  • No. of Pairs: Up to 50 Pairs
  • Rated Temperature: Up to 70 °C
  • Conductor material: 100% Electrolytic Annealed Bare / Tinned Solid Copper as per IS:8130/1984
  • Insulation material & Colour: Specially formulated high grade of PVC/PE Compound Hard grade . Colour of Insulation are as per Table -2 of G/WIR - 06/02 and colour sheds are conforming to IS:9938.
  • Rip Cord: A non-metallic such as nylon suitable rip cord shall be laid up longitudinally under the sheath for effective means of slitting the sheath longitudinally to facilitate removal.
  • Sheath: The Laid up of pairs are covered with PVC Compound as per Type TM2 of IS:13176:1991 of Grey colour.
  • Cond. Resistance: As per IS:8130/1984 AT 20 ° C
  • Insulation Thickness: As per specification
  • PE Tape: YES
  • Jacket material: FR PVC
Salient Features
  • Range : 0.4/0.45/0.5/0.6/0.7/0.8/0.9 mm dia conductors upto 50 pairs .
  • Solid 100% pure annealed bare/Tinned electrolytic copper conductor
  • PVC & PE insulation
  • Individual / Overall shielded with Aluminium tape / Polyster backed .
Application
  • For telecom data transmission in telephones, Intercoms, EPBAX, FAX, close
  • circuit security system, Residential/ Industrial telephone line .
View Complete Details

Axial Cables

  •    
  • Conductor material: 100% Electrolytic Annealed Bare copper Grade solid Copper Conductor.
  • Size of conductor in mm: 1.02
  • Approx DC resistance of conductor at 20° C in Ώ / km: 22
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
  • Insulation compound: Gas Injected Physical Foam Polyethylene.
  • Nominal Capacitance (Pf/M): 53.1
  • Nominal Impedance (Ohm): 75
  • Diameter Over Dielectric(Mm.): 4.6
  • Nominal Overall Diameter(mm.): 6.9
  • Shielding: Polyaluminium Tape Braided with Aluminium Alloy with Minimum 60% Coverage.
  • Jacket: Special formulated, Black Colour PVC Compound.
  • Standard length of wire coil: 100/305
  • Color of Sheath: Black & As per purchase required .
  • Typical Application : Transmission of audio and Video Signals and in CATV System.
Salient Features
  • Range : RG-59, RG-11 & RG-6 Co-axial .
  • Solid 100% pure annealed bare electrolytic copper conductor
  • Foam / PE insulated co-axial cables .
  • Overall shielded with melinex Tape /wire braiding/Aluminium foil taping .
Application
  • For signals transmission for satellite TV telecom, microwave signals and Close Circuit TV, CATV/MATV industry
View Complete Details

Data Networking Cable

  • Specifications: ISO/IEC-11801 2Ed, TIA/EIA568-C.2-1, EN: 50173, EN:50288-6-1
  • Range: CAT-5e Data cable
  • Rated Temperature: 60 °C , 75 °C
  • Frequency: 100MHz
  • Conductor material: Bare Copper
  • Conductor diameter: Solid one: 0.57mm±0.005mm (23AWG)
  • Num of Conductor: 4Pair easily identified
  • Insulation material: HDPE
  • Insulation diameter: 1.03±0.02mm
  • Spline: YES
  • PE Tape: YES
  • PET/AL: Not-applicable
  • Ripcord: YES
  • Filler / Filling material: Not-applicable
  • Drain wire: ----------
  • Jacket material: FR PVC
  • Attenuation (dB/100 meters at 20°C ) Max. : 22 of 100 MHz
  • Return Loss (dB ) Min.: 16 of 100 MHz

salient features

  • range : cat-5e & cat-6e data cables .
  • solid 100% pure annealed bare electrolytic copper conductor
  • low attenuation and cross talk .
  • low structural return loss.
  • 100 oms impedance cables .
application
  • for telecom data transmission in telephones, intercoms, epbox, fax, close circuit security
  • system, residential / industrial telephone line .
View Complete Details

Instrumentation Cables

Salient Features
  • Range : 1.5 to 2.5 Sqmm , 300/500Volts Grade confirming to BS:5308-I & II
  • Shielding: Core/Pair/Triad/Quads .
  • Stranded/Flexible/Solid, 100% pure annealed bare/Tinned electrolytic copper conductor
  • Unarmoured/Armoured- Galvanized Steel roung wire/flat strip
  • Low attenuation and cross talk .
  • Low structural return loss.
  • High Transmission Reliability .
Application
  • Used in data Acquisition systems, computer networking.PA systems, Digital
  • control/Measuring & Communication systems. Speciallly designed to
  • transmit signals without any external interference .
View Complete Details

Control Cables

  • Specifications: IS 1554-1/1988 & IS:7098-1/1988
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 1.5 & 2.5 mm2 and upto 10 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: Up to 61 core for 1.5 & 2.5 sqmm and 4, 6, 10 up to 4 core
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation / XLPE 90°C
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C for PVC insulated & 250° for XLPE insulated .
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded, Type A & C of IS:5831/1984 & XLPE compound as per IS:7098-1/88
  • PVC insulation thickness: As per table 2 of IS 1554-1/1988 & table no 3 of IS:7098-1/1988
  • Color of PVC insulation: As per Clause No. 10 0f IS:1554-1/88 / IS :7098-1/1988
  • Standard length of Cables : 500/1000
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • Laying Up of core : As per table No. 3 of IS:1554-1/1988 & table no. 4 of IS:7098-1/1988
  • Inner Sheath Material : Extruded, PVC Type ST1 & ST2 of IS:5831/1984
  • PVC inner sheath thickness : As per table 4 of IS 1554-1/1988 & table 5 of IS:7098-1/1988
  • Color of Inner sheath : Black & As per purchaser required .
  • Armouring : Galvanized Steel roung wire/strip used for as per Table no. 5 of IS:1554-1/1988 & Table no. 6 of IS:7098-1/1988 only armoured cables
  • PVC Sheathed compound for multicore cables: Extruded, PVC Type ST1, ST2 FR, FR-LSH
  • PVC Sheath thickness & tolerance: As per table 7 of IS:1554-1/1988 & table 8 of of IS 7098-1/1988
  • Color of Sheath: Black & As per purchase required .
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
Salient Features
  • Range : 1.5 to 2.5 Sqmm up to 61 Core , 1100 Volts Grade confirming to IS:1554-1/1988 & IS:7098-1/1988.
  • Stranded/Solid, 100% pure bare annealed electrolytic copper conductor
  • Insulation PVC/XLPE/HR
  • Unarmoured/Armoured- Galvanized Steel roung wire/flat strip
  • Outer sheath PVC Type-ST-1 / ST2 .
  • Heavy Duty Performance .
Application
  • Control cables used for power switch yard control/Relay Equipment & all Industries .
View Complete Details

Submersible Cables

  • Brand Name HPL
  • Feature High Tensile Strength, Quality Assured
  • Specifications: IS 694/1990
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 1.0 to 50 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: 3 core
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded Double layer Type A of IS:5831/1984
  • PVC insulation thickness: As per table 5/6 of IS 694
  • Color of PVC insulation: As per IS:694-1990, Table No. 7
  • Standard length of wire coil : 100/500/1000
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • PVC Sheathed compound for multicore cables: Extruded, PVC Type ST1, FR, FR-LSH
  • PVC Sheath thickness & tolerance: As per table 5 / 6 of IS 694
  • Color of Sheath: Black & As per purchase required .
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm

Salient Features

  • Range : 0.5 to 50 Sqmm in Multi core cables
  • Stranded/Flexible/Solid bare annealed 100% electrolytic grade copper conductor
  • Specially formulated PVC Compound (Type-A & ST-1)
  • Round Submersible cables can be specially asked for .
  • Conforms to IS:694/1990 .

Application

  • Three core sheathed flat cable can be used in Submersible Pump & moter for agriculture etc.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Electrical Cables & Wires from Noida, Uttar Pradesh by HPL Electric and Power Limited
Post Buy Requirement
HE
Noida, Uttar Pradesh, India
Verified Add Review

Electrical Cables & Wires #3733858

3 Core Flat Cable

  • Color Black
  • Feature Crack Free, Durable, High Ductility, High Tensile Strength, Quality Assured
  • Voltage 110V
  • Innner Material Aluminium
  • Length 10-20mtr
  • Load Capacity 1-3kw
  • Thickness 0.5-1mm, 5.5-6mm
  • Size of conductor Size of conductor in mm2

3 Core Flat Submersible Cable, StrandedFlexibleSolid bare annealed 100% electrolytic grade copper conductor, Round Submersible cables can be specially asked for , Conforms to IS:6941990.

View Complete Details

ZHFR Wire

  • Size of conductor Size of conductor
  • Voltages grade Up to 1100 Volts
Single Core Unsheathed (ZHFR), Multi strand 100% Pure annealed Electrolytic copper conductor, ZHFR insulated compound Non-PVC, Bunching of copper in uniform lay & diameter, 100 % Free PVC and eco friendly, Low toxic & corrosive gases.
View Complete Details

Telephone Wire

Range : 0.40.450.50.60.70.80.9 mm dia conductors upto 50 pairs, Solid 100% pure annealed bareTinned electrolytic copper conductor, PVC & PE insulation, Individual Overall shielded with Aluminium tape Polyster backed.
View Complete Details

Industrial Wire

  • Specifications: IS 694/1990
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 0.5 to 400 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: 1
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded Double layer PVC Type A/ FR/ HR/ FR-LSH
  • PVC insulation thickness & tolerance: As per table 2 / 3 / 4 of IS 694
  • Color of PVC insulation: As per purchase required & IS:694-1990, Table No. 7
  • Standard length of wire coil: 90/180/270
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • PVC Sheathed compound for multicore cables: N/A
  • PVC Sheath thickness & tolerance: N/A
  • Color of Sheath: N/A
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
Salient Features

  • Range : 0.5 to 400 Sqmm in Single core cables
  • Multi strand 100% Pure annealed Electrolytic copper conductor
  • FR/FR-LSH insulation conforms to IS:694/1990
  • Bunching of copper in uniform lay & diameter
  • High insulation Resistance
  • Double insulation with ultra thin layer
Application

  • Used in duct, conduit, or Aerial wiring for electric power in Houses, Buildings, Flats, Apartments, Hospitals, Theaters, EducationInstitutions & Factories also used with UPS, Invertor, Battery, control panels etc .
View Complete Details

Telephone Cables

  • Specifications: TEC Specification G/WIR 06/02
  • Range: 0.4/0.45/0.5/0.6/0.7/0.8/0.9 mm dia
  • No. of Pairs: Up to 50 Pairs
  • Rated Temperature: Up to 70 °C
  • Conductor material: 100% Electrolytic Annealed Bare / Tinned Solid Copper as per IS:8130/1984
  • Insulation material & Colour: Specially formulated high grade of PVC/PE Compound Hard grade . Colour of Insulation are as per Table -2 of G/WIR - 06/02 and colour sheds are conforming to IS:9938.
  • Rip Cord: A non-metallic such as nylon suitable rip cord shall be laid up longitudinally under the sheath for effective means of slitting the sheath longitudinally to facilitate removal.
  • Sheath: The Laid up of pairs are covered with PVC Compound as per Type TM2 of IS:13176:1991 of Grey colour.
  • Cond. Resistance: As per IS:8130/1984 AT 20 ° C
  • Insulation Thickness: As per specification
  • PE Tape: YES
  • Jacket material: FR PVC
Salient Features
  • Range : 0.4/0.45/0.5/0.6/0.7/0.8/0.9 mm dia conductors upto 50 pairs .
  • Solid 100% pure annealed bare/Tinned electrolytic copper conductor
  • PVC & PE insulation
  • Individual / Overall shielded with Aluminium tape / Polyster backed .
Application
  • For telecom data transmission in telephones, Intercoms, EPBAX, FAX, close
  • circuit security system, Residential/ Industrial telephone line .
View Complete Details

Axial Cables

  •    
  • Conductor material: 100% Electrolytic Annealed Bare copper Grade solid Copper Conductor.
  • Size of conductor in mm: 1.02
  • Approx DC resistance of conductor at 20° C in Ώ / km: 22
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
  • Insulation compound: Gas Injected Physical Foam Polyethylene.
  • Nominal Capacitance (Pf/M): 53.1
  • Nominal Impedance (Ohm): 75
  • Diameter Over Dielectric(Mm.): 4.6
  • Nominal Overall Diameter(mm.): 6.9
  • Shielding: Polyaluminium Tape Braided with Aluminium Alloy with Minimum 60% Coverage.
  • Jacket: Special formulated, Black Colour PVC Compound.
  • Standard length of wire coil: 100/305
  • Color of Sheath: Black & As per purchase required .
  • Typical Application : Transmission of audio and Video Signals and in CATV System.
Salient Features
  • Range : RG-59, RG-11 & RG-6 Co-axial .
  • Solid 100% pure annealed bare electrolytic copper conductor
  • Foam / PE insulated co-axial cables .
  • Overall shielded with melinex Tape /wire braiding/Aluminium foil taping .
Application
  • For signals transmission for satellite TV telecom, microwave signals and Close Circuit TV, CATV/MATV industry
View Complete Details

Data Networking Cable

  • Specifications: ISO/IEC-11801 2Ed, TIA/EIA568-C.2-1, EN: 50173, EN:50288-6-1
  • Range: CAT-5e Data cable
  • Rated Temperature: 60 °C , 75 °C
  • Frequency: 100MHz
  • Conductor material: Bare Copper
  • Conductor diameter: Solid one: 0.57mm±0.005mm (23AWG)
  • Num of Conductor: 4Pair easily identified
  • Insulation material: HDPE
  • Insulation diameter: 1.03±0.02mm
  • Spline: YES
  • PE Tape: YES
  • PET/AL: Not-applicable
  • Ripcord: YES
  • Filler / Filling material: Not-applicable
  • Drain wire: ----------
  • Jacket material: FR PVC
  • Attenuation (dB/100 meters at 20°C ) Max. : 22 of 100 MHz
  • Return Loss (dB ) Min.: 16 of 100 MHz

salient features

  • range : cat-5e & cat-6e data cables .
  • solid 100% pure annealed bare electrolytic copper conductor
  • low attenuation and cross talk .
  • low structural return loss.
  • 100 oms impedance cables .
application
  • for telecom data transmission in telephones, intercoms, epbox, fax, close circuit security
  • system, residential / industrial telephone line .
View Complete Details

Instrumentation Cables

Salient Features
  • Range : 1.5 to 2.5 Sqmm , 300/500Volts Grade confirming to BS:5308-I & II
  • Shielding: Core/Pair/Triad/Quads .
  • Stranded/Flexible/Solid, 100% pure annealed bare/Tinned electrolytic copper conductor
  • Unarmoured/Armoured- Galvanized Steel roung wire/flat strip
  • Low attenuation and cross talk .
  • Low structural return loss.
  • High Transmission Reliability .
Application
  • Used in data Acquisition systems, computer networking.PA systems, Digital
  • control/Measuring & Communication systems. Speciallly designed to
  • transmit signals without any external interference .
View Complete Details

Control Cables

  • Specifications: IS 1554-1/1988 & IS:7098-1/1988
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 1.5 & 2.5 mm2 and upto 10 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: Up to 61 core for 1.5 & 2.5 sqmm and 4, 6, 10 up to 4 core
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation / XLPE 90°C
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C for PVC insulated & 250° for XLPE insulated .
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded, Type A & C of IS:5831/1984 & XLPE compound as per IS:7098-1/88
  • PVC insulation thickness: As per table 2 of IS 1554-1/1988 & table no 3 of IS:7098-1/1988
  • Color of PVC insulation: As per Clause No. 10 0f IS:1554-1/88 / IS :7098-1/1988
  • Standard length of Cables : 500/1000
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • Laying Up of core : As per table No. 3 of IS:1554-1/1988 & table no. 4 of IS:7098-1/1988
  • Inner Sheath Material : Extruded, PVC Type ST1 & ST2 of IS:5831/1984
  • PVC inner sheath thickness : As per table 4 of IS 1554-1/1988 & table 5 of IS:7098-1/1988
  • Color of Inner sheath : Black & As per purchaser required .
  • Armouring : Galvanized Steel roung wire/strip used for as per Table no. 5 of IS:1554-1/1988 & Table no. 6 of IS:7098-1/1988 only armoured cables
  • PVC Sheathed compound for multicore cables: Extruded, PVC Type ST1, ST2 FR, FR-LSH
  • PVC Sheath thickness & tolerance: As per table 7 of IS:1554-1/1988 & table 8 of of IS 7098-1/1988
  • Color of Sheath: Black & As per purchase required .
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm
Salient Features
  • Range : 1.5 to 2.5 Sqmm up to 61 Core , 1100 Volts Grade confirming to IS:1554-1/1988 & IS:7098-1/1988.
  • Stranded/Solid, 100% pure bare annealed electrolytic copper conductor
  • Insulation PVC/XLPE/HR
  • Unarmoured/Armoured- Galvanized Steel roung wire/flat strip
  • Outer sheath PVC Type-ST-1 / ST2 .
  • Heavy Duty Performance .
Application
  • Control cables used for power switch yard control/Relay Equipment & all Industries .
View Complete Details

Submersible Cables

  • Brand Name HPL
  • Feature High Tensile Strength, Quality Assured
  • Specifications: IS 694/1990
  • Conductor material: 100% Electrolytic Annealed Bare Copper As per IS:8130/1984
  • Shape of conductor: Flexible / Stranded / Solid
  • Size of conductor in mm2: 1.0 to 50 mm2
  • No of strands / conductor: As per IS 8130
  • Maximum resistance of conductor at 20°C in Ώ / km: As per table 1, 2 & 3 of IS 8130
  • Number of Core: 3 core
  • Max. rated conductor Temperature: 70° C for General purpose insulation & 85° for HR insulation
  • Currents Rating : As per IS: 3961 part 5, Table No -1, 2 & 6
  • Max. temperature of conductor during short circuit: 160° C
  • Voltages grade: Up to 1100 Volts
  • PVC insulation compound: Extruded Double layer Type A of IS:5831/1984
  • PVC insulation thickness: As per table 5/6 of IS 694
  • Color of PVC insulation: As per IS:694-1990, Table No. 7
  • Standard length of wire coil : 100/500/1000
  • Ambient Temperature: 40°C
  • Approx reactance of cables ohm/km : 50Hz
  • PVC Sheathed compound for multicore cables: Extruded, PVC Type ST1, FR, FR-LSH
  • PVC Sheath thickness & tolerance: As per table 5 / 6 of IS 694
  • Color of Sheath: Black & As per purchase required .
  • max. Safe pulling force copper conductor : 5.0 kg per Sqmm

Salient Features

  • Range : 0.5 to 50 Sqmm in Multi core cables
  • Stranded/Flexible/Solid bare annealed 100% electrolytic grade copper conductor
  • Specially formulated PVC Compound (Type-A & ST-1)
  • Round Submersible cables can be specially asked for .
  • Conforms to IS:694/1990 .

Application

  • Three core sheathed flat cable can be used in Submersible Pump & moter for agriculture etc.