Open Path Gas Detector

The ILUX hydrocarbon gas detector is an open path infrared gas detection system that provides continuous monitoring of combustible hydrocarbon gas concentrations in the range of 0 to 1, 5 LEL/m, 0-2, 5 LEL/m, 0-5 LEL/m, over a distance of 5 to 200 meters. Standard system outputs include 4-20 mA DC current output, with HART and RS-485 MODBUS communication. ILUX is capable of detecting most hydrocarbon gases and vapors including methane, ethane, propane, butane, propylene and others. No direct electrical interconnection between the two modules is required. The application of the ILUX system is allows to substitute for up to 12 fixed gas detectors. The ILUX system consists of two stainless steel modules- a transmitter and a receiver, along with mounting fixture hardware. Both modules are powered from an external 24 volt DC supply. The receiver provides the measurement signal outputs, and is furnished with an onboard status indication LED and an external magnetic bangle for reset setting and zero adjustment. The transmitter contains one ultra-reliable xenon flash lamp. Both modules are installed of approximately the same elevation and must be aligned to point directly at one another. The ILUX transmitter module illuminates a direct linear path ending at the ILUX receiver module. As flammable hydrocarbon gases intersect the light beam between by the two modules, certain IR wavelengths are absorbed by the gas, while other IR wavelengths are not. The amount of IR absorption is determined by the concentration of the hydrocarbon gas. A pair of optical detectors and associated electronics located in the receiver module measures the absorption. The change in the intensity of the absorbed light (active signal) is measured relative to the intensity of light at a non-absorbed wavelength (reference signal). The microprocessor computes the gas concentration and converts the value into a 4-20 mA current output signal (digital signal), which is then communicated to external control and annunciation systems. No filter wheel motors or other moving parts are utilized in either module.

APPLICATION

  • Power stations and petroleum and gas stations
  • Storage of combustive-lubricating materials
  • Tank ships and other vessels
  • Vanish and dye industry
  • Storage of oily products
  • Oil and gas industry
  • LNG/PNG processing and storage

ADVANTAGE

  • System is equivalent of eight fixed gas detectors
  • Low power consumption
  • Detect methane and most hydrocarbon gases including methane, ethane, propane, butane, and propylene
  • Analog, relay and digital outputs
  • 5-200m meters distance
  • Resistance to fog and high humidity
  • Wide range of operating temperature
  • Equal sensitivity to main hydrocarbons
  • High sensitivity to main hydrocarbons
  • High sensitivity and longevity over 10 years
  • Protection from direct contract with contaminants
  • Stainless steel construction
View Complete Details

FIXED PID SENSOR GAS DETECTOR

ILUX-GDF-1001 FIXED GAS MONITOR

Method: Natural Diffusion

Working Voltage: DC24V6V

Power Consumption: 3W

Operation Method: infrared remote control

Working Humidity: 95%RHno dews

Protection Grade: IP65

Description:

ILUX-GDF-1001 series fixed gas detector. It adopts high-quality gas sensitive element and microcontroller technology. It has advantages of good repeatability, temperature & humidity performance, long life and easy to operate.

Applications:

The detector is widely used in industrial gas detection fields where may has dangerous gases such as petroleum and petrochemicals oil refineries, chemical plants, metallurgy industries and power plant

Features:

smart sensor module, easy for sensor replacement

audible and visual alarm

Methodnatural diffusion

Working voltageDC 24V6V

Power consumption3W

Accuracy3%LEL /5%FStoxic gas

Operation method infrared remote control

Response timet90flammable gas30s toxic gas60s

Working temperature

-40+70flammable gas

-20+50toxic gas/oxygen

Working humidity95%RH

Explosion proof levelEx d

Protection degreeIP65

Output signal420mA/RS485

Connecting threadG3/4FPT

Cable1.5 mm23 shielded cable

external diameter 6mm9mm420mA/ 1.5 mm24RS485

Transmission distance1000m

Sensor life3 years for catalytic sensor, 2 years for electrochemical sensor.

View Complete Details

VOC Gas Detector

We are the most reliable VOC Gas Detector Manufacturer, Supplier and Exporter from Vapi, Gujrat. Volatile organic compounds (VOCs) are organic chemicals that have a high vapor pressure at ordinary, room-temperature conditions. Their high vapor pressure causes the molecules to evaporate from the liquid or solid form of the compound and enter the surrounding air. These vapor form of VOCs is detectable by a VOC Gas Detector and hence we come to know its presence in environment. VOCs are numerous, varied, and ubiquitous. They include both man-made and naturally occurring chemical compounds. Many VOCs are dangerous to human health or cause harm to the environment. VOCs are typically not acutely toxic, but instead have compounding long-term health effects. PID (Photoionization) : A photoionization detector measure volatile organic compounds and other gases. It uses an ultraviolet (UV) light source (photo = light) to break down chemicals to positive and negative ions (ionization) that can easily be counted with a detector. Ionization occurs when a molecule absorbs the high-energy UV light, which excites the molecule and results in the temporary loss of a negatively charged electron and the formation of positively charged ion. The gas becomes electrically charged. In the PID, these charged particles produce a current that is then amplified and displayed on the meter as "ppm" (parts per million) or even in "ppb" (parts per billion). The ions quickly recombine after passing the electrodes in the detector to re-form their original molecule. PIDs are non-destructive; they do not "burn" or permanently alter the sample gas, which allows them to be used for sample gathering. All Volatile elements and chemicals can be ionized, but they differ in the amount of energy they require. The energy required to displace an electron and "ionize" a compound is called its Ionization Potential (IP), measured in electron volts (eV). The light energy emitted by a UV lamp is also measured in eV. Note : If the IP of the sample gas is less than the eV output of the lamp, then the sample gas will be ionized and detected. We offer VOC Gas Detectors with three different PID lamps : 9.8eV, 10.6eV and 11.7 eV. The standard lamp is 10.6 eV with 3 years warranty. Now, few compounds have IP less than 9.8, few have less than 10.6 and few have more than 10.6 eV. So considering 10.6eV PID lamp we confirm that given compounds shall be detectable with our VOC Gas Detector. These Meter VOC Gas Detectors are manufactured using latest technology to offer accurate performance. Why Our VOC Gas Detector?
  • Highly durable
  • Reliable reading
  • Easy to use
  • Spare parts availability
View Complete Details

Multi Gas Detector

We are a highly reputed Multi Gas Detector Manufacturer, Supplier and Exporter In Gujarat. Our Multi Gas Detector is very popular because of its long lasting performance and easy to handle interface. The Multi Gas Detector offers instant reading with up to four sensors at one time. Product Specifications : QRAE II Multi Gas Detector
  • Size
    • Diffusion : 5" L x 2.8" W x 1.5" H (12.5cm x 7.2cm x 3.8cm)
    • Pump : 5" L x 2.8" W x 2" H (12.5cm x 7.2cm x 5.0cm)
  • Sensors : Catalytic bead for combustibles
  • Oxygen : SPE (non-consumable Solid Polymer Electrolyte technology)
  • Toxic : Electrochemical, H2S, CO or SO2
  • Battery : Interchangeable Lithium-ion and alkaline battery packs
  • Operating Period
    • Diffusion : Up to 14 hours continuous operation with Lithium-ion battery, up to 10 hours with alkaline battery (typical, without alarm)
    • Pump : Up to 10 hours with Lithium-ion battery, up to 8 hours with alkaline battery
  • Display Graphic : 4 lines, with LED automatic back light in dim light or alarm condition
  • Key Pad : Two Key Operations
  • Direct Readout
    • Instant reading of up to four sensors
    • Oxygen as percentage by volume scalable using correction factors
    • Toxic gases as parts per million
    • High and low values for all gases
    • Battery and shutdown voltage
    • Date, time, elapsed time, temperature
  • Alarms
    • 95dB buzzer (at 30 cm) and flashing red LED
    • High : 3 beeps and flashes per second
    • Low : 2 beeps and flashes per second
    • STEL and TWA : 1 beep, vibration and flash per second
    • Alarms : latching with manual override or automatic reset
    • Additional diagnostic alarm and display message for low battery
  • IP Rating : IP 65
  • Data logging : Standard 12 days at one-minute intervals
  • Calibration : Two-point calibration for zero and span
  • Sampling Pump : Optional, internal pump 300 cc/mn
  • Hazardous Area Approval
    • US and Canada : C1, D1, Groups A, B, C, D, T4
    • Europe : ATEX II 2G EEx ia d IIc T4
    • IECEX : Ex ia d II C T4
  • Attachments : Stainless-steel alligator clip
View Complete Details

Toxic Gas Detectors

We are offering toxic gas detectors. toxi rae ii (portable personal gas detector) features size - 3.6 x 1.9 x 0.9 battery - user replaceable 23 aa high cpacity lithium battery display - easy to read lcd for continuous display of concentration in ppm and text messages keypad - one button operation direct readout - instantaneous display of toxic gas concentration in ppm (or o2 in vol. %) stel & twa values peak hold alarm minutes consumed alarms - audible 90 db at 10 cm visible: bright redgreen led bar visible fromtop, front, and sides
View Complete Details

Fixed Type Gas Detector

We are offering Fixed Type Gas Detector.raeguard s (online fixed type gas detector) the rae guard s is a permanently installed gas detector for hydrocarbon combustible gases, carbon dioxide and a wide range of toxic gases. it is a flexible detector which provides both an analog (4-20ma) and digital (rs-485, modbus rtu) output signal. the raeguard s uses a smart sensor which can be off-line pre-calibrated. an explosion-proof stainless steel enclosure and magnetic key non-intrusive operation make the raeguard s ideal for use in hazardous environments. the raeguard s is equipped with a local digital display and leds for viewing of gas concentration and alarm conditions.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Security, Metal & Leak Detectors from Vapi, Gujarat by Hind Electrical Co.
Post Buy Requirement
Hind Electrical Co.
Vapi, Gujarat, India
Add Review

Security, Metal & Leak Detectors #113486

Open Path Gas Detector

The ILUX hydrocarbon gas detector is an open path infrared gas detection system that provides continuous monitoring of combustible hydrocarbon gas concentrations in the range of 0 to 1, 5 LEL/m, 0-2, 5 LEL/m, 0-5 LEL/m, over a distance of 5 to 200 meters. Standard system outputs include 4-20 mA DC current output, with HART and RS-485 MODBUS communication. ILUX is capable of detecting most hydrocarbon gases and vapors including methane, ethane, propane, butane, propylene and others. No direct electrical interconnection between the two modules is required. The application of the ILUX system is allows to substitute for up to 12 fixed gas detectors. The ILUX system consists of two stainless steel modules- a transmitter and a receiver, along with mounting fixture hardware. Both modules are powered from an external 24 volt DC supply. The receiver provides the measurement signal outputs, and is furnished with an onboard status indication LED and an external magnetic bangle for reset setting and zero adjustment. The transmitter contains one ultra-reliable xenon flash lamp. Both modules are installed of approximately the same elevation and must be aligned to point directly at one another. The ILUX transmitter module illuminates a direct linear path ending at the ILUX receiver module. As flammable hydrocarbon gases intersect the light beam between by the two modules, certain IR wavelengths are absorbed by the gas, while other IR wavelengths are not. The amount of IR absorption is determined by the concentration of the hydrocarbon gas. A pair of optical detectors and associated electronics located in the receiver module measures the absorption. The change in the intensity of the absorbed light (active signal) is measured relative to the intensity of light at a non-absorbed wavelength (reference signal). The microprocessor computes the gas concentration and converts the value into a 4-20 mA current output signal (digital signal), which is then communicated to external control and annunciation systems. No filter wheel motors or other moving parts are utilized in either module.

APPLICATION

  • Power stations and petroleum and gas stations
  • Storage of combustive-lubricating materials
  • Tank ships and other vessels
  • Vanish and dye industry
  • Storage of oily products
  • Oil and gas industry
  • LNG/PNG processing and storage

ADVANTAGE

  • System is equivalent of eight fixed gas detectors
  • Low power consumption
  • Detect methane and most hydrocarbon gases including methane, ethane, propane, butane, and propylene
  • Analog, relay and digital outputs
  • 5-200m meters distance
  • Resistance to fog and high humidity
  • Wide range of operating temperature
  • Equal sensitivity to main hydrocarbons
  • High sensitivity to main hydrocarbons
  • High sensitivity and longevity over 10 years
  • Protection from direct contract with contaminants
  • Stainless steel construction
View Complete Details

FIXED PID SENSOR GAS DETECTOR

ILUX-GDF-1001 FIXED GAS MONITOR

Method: Natural Diffusion

Working Voltage: DC24V6V

Power Consumption: 3W

Operation Method: infrared remote control

Working Humidity: 95%RHno dews

Protection Grade: IP65

Description:

ILUX-GDF-1001 series fixed gas detector. It adopts high-quality gas sensitive element and microcontroller technology. It has advantages of good repeatability, temperature & humidity performance, long life and easy to operate.

Applications:

The detector is widely used in industrial gas detection fields where may has dangerous gases such as petroleum and petrochemicals oil refineries, chemical plants, metallurgy industries and power plant

Features:

smart sensor module, easy for sensor replacement

audible and visual alarm

Methodnatural diffusion

Working voltageDC 24V6V

Power consumption3W

Accuracy3%LEL /5%FStoxic gas

Operation method infrared remote control

Response timet90flammable gas30s toxic gas60s

Working temperature

-40+70flammable gas

-20+50toxic gas/oxygen

Working humidity95%RH

Explosion proof levelEx d

Protection degreeIP65

Output signal420mA/RS485

Connecting threadG3/4FPT

Cable1.5 mm23 shielded cable

external diameter 6mm9mm420mA/ 1.5 mm24RS485

Transmission distance1000m

Sensor life3 years for catalytic sensor, 2 years for electrochemical sensor.

View Complete Details

VOC Gas Detector

We are the most reliable VOC Gas Detector Manufacturer, Supplier and Exporter from Vapi, Gujrat. Volatile organic compounds (VOCs) are organic chemicals that have a high vapor pressure at ordinary, room-temperature conditions. Their high vapor pressure causes the molecules to evaporate from the liquid or solid form of the compound and enter the surrounding air. These vapor form of VOCs is detectable by a VOC Gas Detector and hence we come to know its presence in environment. VOCs are numerous, varied, and ubiquitous. They include both man-made and naturally occurring chemical compounds. Many VOCs are dangerous to human health or cause harm to the environment. VOCs are typically not acutely toxic, but instead have compounding long-term health effects. PID (Photoionization) : A photoionization detector measure volatile organic compounds and other gases. It uses an ultraviolet (UV) light source (photo = light) to break down chemicals to positive and negative ions (ionization) that can easily be counted with a detector. Ionization occurs when a molecule absorbs the high-energy UV light, which excites the molecule and results in the temporary loss of a negatively charged electron and the formation of positively charged ion. The gas becomes electrically charged. In the PID, these charged particles produce a current that is then amplified and displayed on the meter as "ppm" (parts per million) or even in "ppb" (parts per billion). The ions quickly recombine after passing the electrodes in the detector to re-form their original molecule. PIDs are non-destructive; they do not "burn" or permanently alter the sample gas, which allows them to be used for sample gathering. All Volatile elements and chemicals can be ionized, but they differ in the amount of energy they require. The energy required to displace an electron and "ionize" a compound is called its Ionization Potential (IP), measured in electron volts (eV). The light energy emitted by a UV lamp is also measured in eV. Note : If the IP of the sample gas is less than the eV output of the lamp, then the sample gas will be ionized and detected. We offer VOC Gas Detectors with three different PID lamps : 9.8eV, 10.6eV and 11.7 eV. The standard lamp is 10.6 eV with 3 years warranty. Now, few compounds have IP less than 9.8, few have less than 10.6 and few have more than 10.6 eV. So considering 10.6eV PID lamp we confirm that given compounds shall be detectable with our VOC Gas Detector. These Meter VOC Gas Detectors are manufactured using latest technology to offer accurate performance. Why Our VOC Gas Detector?
  • Highly durable
  • Reliable reading
  • Easy to use
  • Spare parts availability
View Complete Details

Multi Gas Detector

We are a highly reputed Multi Gas Detector Manufacturer, Supplier and Exporter In Gujarat. Our Multi Gas Detector is very popular because of its long lasting performance and easy to handle interface. The Multi Gas Detector offers instant reading with up to four sensors at one time. Product Specifications : QRAE II Multi Gas Detector
  • Size
    • Diffusion : 5" L x 2.8" W x 1.5" H (12.5cm x 7.2cm x 3.8cm)
    • Pump : 5" L x 2.8" W x 2" H (12.5cm x 7.2cm x 5.0cm)
  • Sensors : Catalytic bead for combustibles
  • Oxygen : SPE (non-consumable Solid Polymer Electrolyte technology)
  • Toxic : Electrochemical, H2S, CO or SO2
  • Battery : Interchangeable Lithium-ion and alkaline battery packs
  • Operating Period
    • Diffusion : Up to 14 hours continuous operation with Lithium-ion battery, up to 10 hours with alkaline battery (typical, without alarm)
    • Pump : Up to 10 hours with Lithium-ion battery, up to 8 hours with alkaline battery
  • Display Graphic : 4 lines, with LED automatic back light in dim light or alarm condition
  • Key Pad : Two Key Operations
  • Direct Readout
    • Instant reading of up to four sensors
    • Oxygen as percentage by volume scalable using correction factors
    • Toxic gases as parts per million
    • High and low values for all gases
    • Battery and shutdown voltage
    • Date, time, elapsed time, temperature
  • Alarms
    • 95dB buzzer (at 30 cm) and flashing red LED
    • High : 3 beeps and flashes per second
    • Low : 2 beeps and flashes per second
    • STEL and TWA : 1 beep, vibration and flash per second
    • Alarms : latching with manual override or automatic reset
    • Additional diagnostic alarm and display message for low battery
  • IP Rating : IP 65
  • Data logging : Standard 12 days at one-minute intervals
  • Calibration : Two-point calibration for zero and span
  • Sampling Pump : Optional, internal pump 300 cc/mn
  • Hazardous Area Approval
    • US and Canada : C1, D1, Groups A, B, C, D, T4
    • Europe : ATEX II 2G EEx ia d IIc T4
    • IECEX : Ex ia d II C T4
  • Attachments : Stainless-steel alligator clip
View Complete Details

Toxic Gas Detectors

We are offering toxic gas detectors. toxi rae ii (portable personal gas detector) features size - 3.6 x 1.9 x 0.9 battery - user replaceable 23 aa high cpacity lithium battery display - easy to read lcd for continuous display of concentration in ppm and text messages keypad - one button operation direct readout - instantaneous display of toxic gas concentration in ppm (or o2 in vol. %) stel & twa values peak hold alarm minutes consumed alarms - audible 90 db at 10 cm visible: bright redgreen led bar visible fromtop, front, and sides
View Complete Details

Fixed Type Gas Detector

We are offering Fixed Type Gas Detector.raeguard s (online fixed type gas detector) the rae guard s is a permanently installed gas detector for hydrocarbon combustible gases, carbon dioxide and a wide range of toxic gases. it is a flexible detector which provides both an analog (4-20ma) and digital (rs-485, modbus rtu) output signal. the raeguard s uses a smart sensor which can be off-line pre-calibrated. an explosion-proof stainless steel enclosure and magnetic key non-intrusive operation make the raeguard s ideal for use in hazardous environments. the raeguard s is equipped with a local digital display and leds for viewing of gas concentration and alarm conditions.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us