Control Panels #864928

Engine Control Device

LGC Engine Control Device Introduction -The Microcontroller/microprocessor based Engine Control Device is designed to suit the necessary requirements of customer. - Backlit LCD display for easy reading of parameters. - All the inputs like main, generator and battery voltages are fully isolated to avoid malfunctioning of system. Suitable for all type of gensets. - Molded in 96mm * 96mm * 110mm plastic cabinet is suitable to mount in panel. Protection and supervision LCD Display -All the working status of unit according to the present supply is displayed. - Displays Voltage, Current, Frequency and RPM Battery voltage and Engine run time when the generator is in running Condition. Push Buttons - Manual Start. - Manual Stop/Reset. Engine Safety Features - LLOP - HWT - LFL - Engine service due tripping Visual Display - Voltage - Current - Frequency - RPM - Engine Run Time - Battery Voltage Alternator Safety Features - Over and under voltage trip. - Over and under frequency trip. - Over and under RPM trip. - Over current trip. Note: The over current tripping and Engine Service due time can be set manually.

View Complete Details

Generator Control Panel

Avail from us Generator Control Panel that is fabricated with M.S. sheet with powder coated paint finish. The Generator Control Panel that we provide is acclaimed for its uninterrupted performance and reliability. Made using latest technology tools and devices, our Generator Control Panels serve longer in comparison to other panels. We are a reputed name as Generator Control Panel Manufacturer and Supplier in Malerkotla, Punjab. Specifications Of Engine Control Panel :

  • 1 Pilot lamps to indicate Battery connected.
  • 1 Pilot lamp to indicate generator On.
  • 1 pilot lamp for load on.
  • 1 push button to start the generator.
  • 1 push button to stop the generator.
  • 1 Digital Engine control unit to display voltage, amp., frequency rpm, engine run time and battery voltage when the generator is running condition with all engine safety features like LLOP fault trip, High water temperature trip, Low fuel level trip, and all alternator safety features like under and over voltage trip, under and over RPM trip, under and over frequency trip, over current trip and engine service due tripping.
  • connection strip 4 way to connect the input and output of generator supply
  • 1 connection strip 3 way to connect the engine safety inputs for LLOP, HWt and LFL
  • 1 MCB for short circuit trip.

Note : Auto start and auto stop features are also available in the panel if required. The Details For The Same Are As Follows :

  • Auto start diesel generator on mains failure after a delay time of 5 seconds.
  • Four more starting impulses if the engine does not start in one attempt after a delay time of each 10 second.
  • Automatic lock out if generator fails to start.
  • One auto/manual switch provided on panel to change the working status.
  • Display of voltage, frequency, current and RPM. When the generator is in running condition.
  • Under and over voltage tripping.
  • Under and over frequency tripping.
  • Under and over RPM tripping.
  • Over current tripping.
  • During the resumption of main supply generator stops automatically with a delay time of 30 seconds.
View Complete Details

Engine Control Panel

  • Brand Name Selfguard
  • Model Number generator engine control panel with auto start and auto stop
  • Place of Origin malerkotla

Specifications of Engine control panel Panel is fabricated with M.S. sheet with powder coated paint finish. 1. 1 Pilot lamps to indicate Battery connected. 2. 1 Pilot lamp to indicate generator On. 3. 1 pilot lamp for load on. 4. 1 push button to start the generator. 5. 1 push button to stop the generator. 6. 1 Digital Engine control unit to display voltage, amp., frequency rpm, engine run time and battery voltage when the generator is running condition with all engine safety features like LLOP fault trip, High water temperature trip, Low fuel level trip, and all alternator safety features like under and over voltage trip, under and over RPM trip, under and over frequency trip, over current trip and engine service due tripping. 7. 1. connection strip 4 way to connect the input and output of generator supply 8. 1 connection strip 3 way to connect the engine safety inputs for LLOP, HWt and LFL 9. 1 MCB for short circuit trip. Auto start and auto stop features are also available in the panel if required. The details for the same is as under: 1. Auto start diesel generator on mains failure after a delay time of 5 seconds. 2. Four more starting impulses if the engine does not start in one attempt after a delay time of each 10 second. 3. Automatic lock out if generator fails to start. 4. One auto/manual switch provided on panel to change the working status. 5. Display of voltage, frequency, current and RPM. When the generator is in running condition. 6. Under and over voltage tripping. 7. Under and over frequency tripping. 8. Under and over RPM tripping. 9. Over current tripping. 10. During the resumption of main supply generator stops automatically with a delay time of 30 seconds.

View Complete Details

Standard Generator Control Panel

Specifications of Engine control panel Panel is fabricated with M.S. sheet with powder coated paint finish. 1. 1 Pilot lamps to indicate Battery connected. 2. 1 Pilot lamp to indicate generator On. 3. 1 pilot lamp for load on. 4. 1 push button to start the generator. 5. 1 push button to stop the generator. 6. 1 Digital Engine control unit to display voltage, amp., frequency rpm, engine run time and battery voltage when the generator is running condition with all engine safety features like LLOP fault trip, High water temperature trip, Low fuel level trip, and all alternator safety features like under and over voltage trip, under and over RPM trip, under and over frequency trip, over current trip and engine service due tripping. 7. 1. connection strip 4 way to connect the input and output of generator supply 8. 1 connection strip 3 way to connect the engine safety inputs for LLOP, HWt and LFL 9. 1 MCB for short circuit trip. Auto start and auto stop features are also available in the panel if required. The details for the same is as under: 1. Auto start diesel generator on mains failure after a delay time of 5 seconds. 2. Four more starting impulses if the engine does not start in one attempt after a delay time of each 10 second. 3. Automatic lock out if generator fails to start. 4. One auto/manual switch provided on panel to change the working status. 5. Display of voltage, frequency, current and RPM. When the generator is in running condition. 6. Under and over voltage tripping. 7. Under and over frequency tripping. 8. Under and over RPM tripping. 9. Over current tripping. 10. During the resumption of main supply generator stops automatically with a delay time of 30 seconds.

View Complete Details

AMF Control Panel

The organization has vast experience in designing and manufacturing AMF Control Panel. The Selfguard AMF Control Panel that we provide A.M.F. panel is fabricated with M.S. sheet with powder coated paint finish. Additionally, the AMF Control Panels are designed as per the industry set norms. The latest technology AMF Control Panels that we offer are acclaimed for their reliable, hassle-free performance. We are a renowned name as AMF Control Panel Manufacturer and Supplier in Malerkotla, Punjab. Specifications Of Selfguard AMF Control Panel :

  • 3 Pilot lamps to indicate mains on.
  • 1 Pilot lamp to indicate generator on.
  • 1 push button for manual stop.
  • 1 push buttom for manual start.
  • 1 switch to select battery Off/On.
  • 1 Digital LGS-2c unit meter to indicate voltage, amp., frequency and rpm when the generator is running condition with all alternator safety features.
  • 3 Electro mechanical relays for mains and 3 electro mechanical relays for generator according to the desired load.
  • connection strip 12 way moulded in D.M.C. material .
  • 1 copper bus bar to connect A.M.F. panel with main supply, generator supply and load.
  • 1 connection strip 30amp. 6 way to connect A.M.F. panel with 12 volts battery, start solenoid,
  • Stop solenoid and GCU control unit.

Working of Selfguard AMF Control Panel :

  • Auto start diesel generator on mains failure (even on single phase failure) after a delay time of 5 seconds.
  • Four more starting impulses if the engine does not start in one attempt after a delay time of each 10 seconds.
  • Automatic lock out if generator fails to start.
  • Auto changeover transfers load automatically on generator supply after the generator starts with a delay time of 5 seconds.
  • Display of voltage, frequency, current and RPM. When the generator is in running condition.
  • Under and over voltage tripping.
  • Under and over frequency tripping.
  • Under and over RPM tripping.
  • Over current tripping.
  • During the resumption of all three phases generator relays are de-energized and mains relays are energized with a delay time of 5 seconds.
  • Generator set runs on no load condition and automatically stops after a delay time of 30 seconds.
View Complete Details