Post Buy Requirement
GS
Delhi, India
Add Review

Load Cell #1115834

ELEVATORS LOADCELL

  • Hysteresis < ± 0.02% FSO
  • Standard Capacities 80-Kgf
  • Excitation Voltage 10VDC-Max. 15VDC
  • Normal Output 2.0 mV/V
  • Non - Linearity < ± 0.025% FSO
  • Non - Repeatability < ± 0.01% FSO
  • Creep (30 minutes) < ± 0.03% FSO
  • Zero balance ± 1.0% FSO
  • Input Resistance 400 ± 15 Ohms
  • Output Resistance 350 ± 5 Ohms
  • Insulation Resistance (50VDC) > 1000 Mega Ohms
  • Cable Length (4 Core Screened) 45Cm.
  • Safe Overload of Related Capacity 150%
  • Ultimate Overload of Rated Capacity 200%
  • Temp Compensated Range 0-60ºC
  • Temprature Effect on Output < 0.0015% FSO/ºC
  • Temprature Effect on Zero < 0.0020% FSO/ºC
  • Platter Size 300mm x 300mm
  • Eccentric Load Effect < 0.02% of FSO at 1/3 rated load placed within the specified sized platter
  • Deflection <0.5mm at FSO
  • Tightening Torque 2 m.Kg
  • Finish & Construction Alluminium Alloy
  • Environmental Protection Class lp65
  • Applications Bench, Counting Postal Scales, Check Weighers
View Complete Details

S Type Load Cells

  • Standard Capacities 80-Kgf
  • Excitation Voltage 10VDC-Max. 15VDC
  • Normal Output 2.0 mV/V
  • Non - Linearity < ± 0.025% FSO
  • Hysteresis < ± 0.02% FSO
  • Non - Repeatability < ± 0.01% FSO
  • Creep (30 minutes) < ± 0.03% FSO
  • Zero balance ± 1.0% FSO
  • Input Resistance 400 ± 15 Ohms
  • Output Resistance 350 ± 5 Ohms
  • Insulation Resistance (50VDC) > 1000 Mega Ohms
  • Cable Length (4 Core Screened) 45Cm.
  • Safe Overload of Related Capacity 150%
  • Ultimate Overload of Rated Capacity 200%
  • Temp Compensated Range 0-60ºC
  • Temprature Effect on Output < 0.0015% FSO/ºC
  • Temprature Effect on Zero < 0.0020% FSO/ºC
  • Platter Size 300mm x 300mm
  • Eccentric Load Effect < 0.02% of FSO at 1/3 rated load placed within the specified sized platter
  • Deflection <0.5mm at FSO
  • Tightening Torque 2 m.Kg
  • Finish & Construction Alluminium Alloy
  • Environmental Protection Class lp65
  • Applications Bench, Counting Postal Scales, Check Weighers
View Complete Details

Table Top Loadcell

  • Hysteresis <±0.02% FSO
  • Standard Capacities 5, 10, 20, 40 - Kgf
  • Excitation Voltage 10 VDC-Maximun 15 VDC
  • Normal Output 2.0 mv/v
  • Non - Linearity <±0.025% FSO
  • Non - Repeatability < ± 0.01% FSO
  • Creep (30 minutes) < ± 0.03% FSO
  • Zero balance ±1.0% FSO
  • Input Resistance 400 ± 15 Ohms
  • Output Resistance 350 ± 5 Ohms
  • Insulation Resistance (50VDC) > 1000 Mega Ohms
  • Cable Length (4 Core Screened) 45Cm.
  • Safe Overload of Related Capacity 150%
  • Ultimate Overload of Rated Capacity 200%
  • Temp Compensated Range 0-60ºC
  • Temprature Effect on Output < 0.0015% FSO/ºC
  • Temprature Effect on Zero < 0.0020% FSO/ºC
  • Platter Size 150mm x 150mm
  • Eccentric Load Effect < 0.02% of FSO at 1/3 rated load placed within the specified sized platter
  • Deflection < 0.5mm at FSO
  • Tightening Torque 1.5 m.Kg.
  • Finish & Alluminium Alloy
  • Construction lP65
  • Environmental Protection Class Table Top Scales, Bench, Bag Weighers, Postal, Check Weighers
View Complete Details

Personal Scale Loadcell

  • Standard Capacities 150-Kgf
  • Excitation Voltage 10 VDC-Max. 15 VDC
  • Normal Output 2.0 m V/v
  • Non - Linearity <±0.025% FSO
  • Hysteresis <±0.02% FSO
  • Non - Repeatability <±0.01% FSO
  • Creep (30 minutes) <±0.03% FSO
  • Zero balance ±1.0% FSO
  • Input Resistance 400±15Ohms
  • Output Resistance 350±5Ohms
  • Insulation Resistance (50VDC) > 1000 Mega Ohms
  • Cable Length (4 Core Screened) 45 Cm.
  • Safe Overload of Related Capacity 150%
  • Ultimate Overload of Rated Capacity 200%
  • Temp Compensated Range 0-60ºC
  • Temprature Effect on Output <0.0015% FSO /ºC
  • Temprature Effect on Zero <0.0020% FSO/ºC
  • Platter Size 300mm*300mm
  • Eccentric Load Effect <0.02% FSO at 1/3 Rated load placed within the specified sized
  • Deflection <0.5mm at FSO
  • Tightening Torque 1.5 m.kg
  • Finish & Alluminium Alloy
  • Construction lp 65
  • Environmental Protection Class Personal, Home, Bench Scales . Check Weighers
View Complete Details

Single Point Loadcells

  • Standard Capacities 1, 3, 5, 10, 20-Kgf
  • Excitation Voltage 10 VDC-Max. 15 VDC
  • Normal Output 2.0 m V/v ±10%
  • Non - Linearity <±0.03% FSO
  • Hysteresis <±0.03% FSO
  • Non - Repeatability <±0.05% FSO
  • Creep (30 minutes) <±0.03% FSO
  • Zero balance 0.5 mV/V
  • Input Resistance 400 ±10 Ohms
  • Output Resistance 350 ±10 Ohms
  • Insulation Resistance (50VDC) > 2000 Mega Ohms
  • Cable Length (4 Core Screened) 35 CM +10% -0%
  • Safe Overload of Related Capacity 150%
  • Ultimate Overload of Rated Capacity 300%
  • Allowable Side Load -0
  • Side Load Discrimination -0
  • Temp Compensated Range -10°~50°C
  • Temprature Effect on Output 0.05% FSO 10 /ºC
  • Temprature Effect on Zero 0.05% FSO 10 /ºC
  • Finish & Aluminum Alloy
  • amp Aluminum Alloy
  • Construction IP65
View Complete Details

Compression Load Cell

  • Standard Capacities 7.5, 15, 22.5, 30, 40, 50, 100, 150, 300, -Tf
  • Excitation Voltage 5VDC-Max. 15VDC
  • Normal Output 2.0 mV/V+ 0.1%
  • Non - Linearity < ± 0.025% FSO
  • Hysteresis < ± 0.02% FSO
  • Non - Repeatability < ± 0.01% FSO
  • Creep (30 minutes) < ± 0.06% FSO
  • Zero balance < =± 5.0% FSO
  • Input Resistance 1150 ± 15 Ohms
  • Output Resistance 1000 ± 2 Ohms
  • Insulation Resistance (50VDC) > 5000 Mega Ohms
  • Cable Length (4 Core Screened) 1800 Cm.
  • Safe Overload of Related Capacity 200%
  • Ultimate Overload of Rated Capacity 300%
  • Allowable Side Load 50%
  • Side Load Discrimination 500.1
  • Temp Compensated Range -10-40ºC
  • Temprature Effect on Output < 0.0020% FSO/ºC
  • Temprature Effect on Zero < =0.0040% FSO/ºC
  • Deflection < 0.5mm at FSO
  • Tightening Torque 5 m.Kg
  • Finish & Electroless Nickel Plated Steel Alloy
  • Construction lP67
  • Environmental Protection Class Tank, Hopper & Truck Weighing, Compressive Force Testing, Industrial Automation
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us