Post Buy Requirement
Golden Electronics

Golden Electronics

Verified Add Review

Other Products / Services

Our product range contains a wide range of Power Monitoring Device, Pre Set Counter, digital monitoring device, analog monitoring device and 6 Window Annunciator

B-Series Electronic Timer

Features :

  • Din sized enclosure for Track (Din rail) / Screw mounting.
  • B1DCA-T : HOLD / RESTART facility during power fail conditions.
  • B1DCA-T : Auto / Manual switch for mode of operation
  • B1DCA-T : Program - enable / disable facility for tamper proof operation.
  • B1DCA-X, B1DCA-T : Independently selectable ON & OFF time.
  • SPP-T :Trips under phase missing, phase reversal or phase unbalance
  • In manual mode, terminals provided to connect to switch so as to manually switch ON and switch OFF load


Applications : Lubricating system, DG Sets, MCC panels, Pump panels and many more.

Dimensions : Over-all: 45 X 75 X 116mm (W X H X D).

Regular Models

Model Function Source Voltage Time Selection Output Dimensions
B1DS Star Delta 440V AC 0.6Secs to 60Secs TD 40ms / 100ms (Transfer Delay Time) 1 C/o (C-NO)Star 1 C/o (C-NO)Delta 45 x 75 x 116 mm (W X H X D)
B1DCA-X Cyclic Adjustable On-Off 24V to 240V AC ,24V DC to 220V DC 0.6Secs to 60Mins 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DCA-T Cyclic Adjustable On-Off 110V AC / 240V AC 0.1Secs to 10Hrs 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DH-Q Power-Off Delay 110V AC to 240V AC, 110V DC to 220V DC 6Secs to 60Secs 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DF On Delay with instant contact 110V AC / 240V AC 0.3Secs to 30Mins 1 C/o On Delay 1 C/o Instant 45 x 75 x 116 mm (W X H X D)

Optional Models

Model Function Source Voltage Time Selection Output Dimensions
B1DCA-T Cyclic Adjustable On-Off 24V DC 0.1Secs to 10 Hrs 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DH-Q Power-Off Delay 110V AC to 240V AC 110V DC to 220V DC 0.6Secs to 6Secs 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DC-A Cyclic Adjustable On-Off 12V DC 0.6secs to 60Mins 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
B1DF On Delay with instant contact 24V DC 0.3Secs to 30Mins 1 C/o On Delay 1 C/o Instant 45 x 75 x 116 mm (W X H X D)
B1DF-R Forward/Reverse with Pause Time 240V AC Forward & Reverse - 0.6Min to 6Mins Pause- 0.1Min to 1Min 1c/o relay forward and 1c/o reverse 45 x 75 x 116 mm (W X H X D)
B1DCA-T Cyclic Adjustable On-Off 110V AC / 240V AC/ 12V DC 0.24Secs to 24Hrs 2 C/o Relay 45 x 75 x 116 mm (W X H X D)
View Complete Details

H-Series Electronic Timer

Features :

  • LED indication for timing in progress
  • Front protective cover for safety.
  • Timer and base available for Track(except H3D1).
  • Large transparent knob with lock is provided for precise time setting and protect from unintentional change of time setting.
  • H1DA-X : Accepts any voltage from 12V AC/DC to 240V AC / 220V DC as signal between command contacts for timing initiation.
  • H1D1-X, H3D1: Multifunction-On-Delay / Interval / Equal Cyclic-On / Equal Cyclic-Off programmable.


Applications : Textile machines, Vending machines and many more.

Dimensions :

  • Over-all: 45 X 75 X 116mm (W X H X D).
  • Cut-out: 46 X 46mm (W x H)

Regular Models

Model Function Source Voltage Time Selection Output CSA Approved Over-All Dimensions Cut-Out Dimensions
H3D1 Multifunction (8 terminals) screw type 24V to 240V AC ,24V DC to 220V DC 0.3Secs to 60Mins 2 C/o Relay   48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H1D1-X(CSA) Multifunction (11 Pin) plug-in type 24V to 240V AC ,24V DC to 220V DC 0.3Secs to 60Mins 2 C/o Relay Yes 48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H1DA-X Signal Off-Delay (11 Pin) plug-in type 24V to 240V AC ,24V DC to 220V DC 0.6Secs to 60Mins 2 C/o Relay   48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H1DT-10(CSA) On-Delay (11 Pin) plug in type. 24V to 240V AC ,24V DC to 220V DC 1Secs to 10Secs 2 C/o Relay Yes 48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H1DT-30(CSA) On-Delay (11 Pin) plug in type. 24V to 240V AC ,24V DC to 220V DC 3Secs to 30Secs 2 C/o Relay Yes 48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H1DT-60(CSA) On-Delay (11 Pin) plug in type. 24V to 240V AC ,24V DC to 220V DC 6Secs to 60Secs 2 C/o Relay Yes 48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H4DT-10 On-Delay (8 Pin) plug-in type. 24V to 240V AC ,24V DC to 220V DC 1Secs to 10Secs 2 C/o Relay   48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H4DT-30 On-Delay (8 Pin) plug-in type. 24V to 240V AC ,24V DC to 220V DC 3Secs to 30Secs 2 C/o Relay   48 x 48 x 94 mm (W X H X D) 46 x 46 mm (W X H )
H4DT-60 On-Delay (8 Pin) plug-in type.   24V to 240V AC ,24V DC to 220V DC 6Secs to 60Secs 2 C/o Relay   48 x 48 x 94 mm (W X H X D)
View Complete Details

Digital Electronic Timer

Features :

  • Din Sized enclosure for panel mounting.
  • Digital dual display for set value and process value.
  • FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE.
  • TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS.
  • One of the relay c/o can be configured as INSTANT or DELAYED.
  • Program lock is provided for function, relay configuration, type of start signal and range selected.
  • RESET cum START facility can be achieved either through front buttons Or Rear terminals
  • HOLD/RESTART facility during power failure conditions.
  • Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal


Dimensions :

  • Over-all: H3PT-MU – 48 x 48 x 95.5mm, C3PT-MU , E3PT-MU – 96 x 96 x 117mm (W x H X D)
  • Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, E3PT-MU – 92 x 92mm (W x H)


ApplicationsInjection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc.

Regular Models

Model Function Source Voltage Time Selection Output Over-All Dimensions Cut-Out Dimensions Datasheet
C3PT-MU Multifunction Up-counting 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1C/o Instant , 1 C/o Delayed or 2c/o Delayed 72 x 72 x 128.5mm (W X H X D) 69 x 69mm (W X H)  
 
E3PT-MU Multifunction Up-counting 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1 C/o Instant , 2 C/o Delayed or 3 C/o Delayed 96 x 96 x 117mm (W X H X D) 92 x 92mm (W X H)  
 
H3PT-MU Multifunction Up-counting 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1C/o Instant , 1 C/o Delayed or 2c/o Delayed 48 x 48 x 95.5mm (W X H X D) 46 x 46mm (W X H)

Optional Models

Model Function Source Voltage Time Selection Output Over-All Dimensions Cut-Out Dimensions
C3PT-MU Multifunction Up-counting 24V DC 0.1Secs to 99Hrs 59Mins 1 C/o Instant , 1 C/o Delayed or 2 C/o Delayed 72 x 72 x 128.5mm (W X H X D) 69 x 69mm (W X H)
H3PT-MU Multifunction Up-counting 12V DC /24V DC 0.1Secs to 99Hrs 59Mins 1 C/o Instant , 1 C/o Delayed or 2 C/o Delayed 48 x 48 x 95.5mm (W X H X D) 46 x 46mm (W X H)
View Complete Details

S-Series Electronic Timer

Features :

  • Suitable for screw mounting(except ST4-M1).
  • 7 segment display indication for channel and timing operation (except ST-4M1).
  • User friendly programming for ON/OFF time selection independently (except ST-4M1).
  • Hold /Restart feature is available during power failure, Over voltage protection(except ST-4M1).
  • ST-6M1 / ST-10M2 / ST-10M1 : pulse start signal.
  • ST-15M2 / ST-4M1 : continuous start signal.
  • S1D-C8M3 : Comprises of 8 Relays and each relay can be programmed for maximum of 8 switchings in a cycle.
  • Potential free (Zero volts) continuous start signal and continuous signal from differential pressure switch is mandatory for operating the timer (Only in model ST-15M2)
  • Feedback outputs for timer healthy, timing in progress and power healthy available in model ST-6M2


Dimensions :

  • Over-all: ST6-M1 / ST6-M2 / ST10-M2 / ST15-M2 / S1DC8-M3 – 200 x130 x 45mm
  • ST4-M1: 110 x 86 x 68mm (W x H x D)
  • ST10-M1 (IP) / ST10-M2 (IP) / ST6-M1 (IP) / ST6-M2 / ST15-M2 – 291 x 214 x 82mm (W x H x D)


ApplicationsBag Filter systems, dust pollution systems, Air handling systems, MCC panels, conveyors, process industries, nitrogen and other gas plants, sewage water treatment plants, irrigation spraying systems and many more.

Regular Models

Model Function Source Voltage Time Selection Output Dimensions
ST4-M1 Sequential Switching 4 channels 240V AC 0.1S/M/H to 1S/M/H 1 C/o NO Relay for each channel 110 x 86 x 68mm (W X H X D)
ST6-M1 Sequential Switching 6 channels 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1 C/o NO Relay for each channel 200 x 130 x 45mm (W X H X D)
ST6-M1(IP) Sequential Switching 6 channels with IP Enclosure 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1 C/o NO Relay for each channel 291 x 214 x 68mm (W X H X D)
ST10-M1(IP) Sequential Switching 10 channels with IP Enclosure 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1 C/o NO Relay for each channel 291 x 214 x 68mm (W X H X D)
ST10-M2(IP) Sequential Switching 10 channels with IP Enclosure 85V to 270V AC / DC 0.01Secs to 99Hrs 59Mins Triac O/p for each channel(Suitable for 240V AC/ 110V AC loads only) 291 x 214 x 68mm (W X H X D)
ST15-M2 Sequential Switching 15 channels 85V to 270V AC 0.01Secs to 99Hrs 59Mins Triac O/p for each channel(Suitable for 240V AC/ 110V AC loads only) 200 x 130 x 45mm (W X H X D)
S1CD8-M3 Combination Switching 8 channels ,8 combinations 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1C/o NO Relay for each Channel 200 x 130 x 45mm (W X H X D)
ST10-M1 Sequential Switching 10 channels 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1 C/o NO Relay for each channel 200 x 130 x 45mm (W X H X D)
ST10-M2 Sequential Switching 10 channels 85V to 270V AC / DC 0.01Secs to 99Hrs 59Mins Triac O/p for each channel(Suitable for 240V AC/ 110V AC loads only) 200 x 130 x 45mm (W X H X D)
ST15-M2(IP) Sequential Switching 15 channels with IP Enclosure 85V to 270V AC 0.01Secs to 99Hrs 59Mins Triac O/p for each channel(Suitable for 240V AC/ 110V AC loads only) 291 x 214 x 68mm (W X H X D)

Optional Models

Model Function Source Voltage Time Selection Output Dimensions
ST6-M2 Sequential Switching 6 channels 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel. 1c/o NO Relay each for timer ready, time in progress and timer On 200 x 130 x 45mm (W X H X D)
ST10-M1 Sequential Switching 10 channels 24V DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel 200 x 130 x 45mm (W X H X D)
           
ST10-M1(IP) Sequential Switching 10 channels with IP Enclosure 24V DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel 291 x 214 x 68mm (W X H X D)
S1CD8-M3 Combination Switching 8 channels, 8 Combination 12V DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel 200 x 130 x 45mm (W X H X D)
ST6-M1 Sequential Switching 6 channels 24V DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel 200 x 130 x 45mm (W X H X D)
ST6-M1(IP) Sequential Switching 6 channels with IP Enclosure 24V DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel 291 x 214 x 68mm (W X H X D)
ST6-M2(IP) Sequential Switching 6 channels with IP Enclosure 85V to 270V AC / DC 0.1Secs to 99Hrs 59Mins 1c/o NO Relay for each channel. 1c/o NO Relay each for timer ready, time in progress and timer On 291 x 214 x 68mm (W X H X D)
View Complete Details

Energy Converter

Features :

  • Aux. supply - wide voltage and frequency range.
  • Compactable baud rate - 2400, 4800, 9600, 19200.
  • Max. no of nodes - 32.
  • Max. cable length (RS-232 side) - 15mtrs typical.
  • Max. cable length (RS-485 side) - 1000mtrs typical.
  • Mounting - Din-rail.
  • LED indication for power, Receiving and Transmitting signals


Dimensions : Overall: 117 x 86 x 61mm (W x H x D)

Applications : Converts RS485 to RS232

View Complete Details

DC Multifunction Meter

Features :

  • Micro Controller based 3 Channel DC Energy Meter
  • Displays DC parameters V, I, KW, KWh , MWh& Load on hours of all three channels.
  • Displays the latest reading of all the cleared energies and load on hours.
  • Display Hold / Scroll Facility available.
  • Programmable Shunt ratios.
  • Alphanumeric display for Parameter & values
  • RS-485 serial port with Modbus RTU output.
  • Wide Input Voltage and Current Range.
  • Protection from dust and water as per IP-51.


Dimensions :

  • Overall:96 x 96 x 117mm (W x H x D)
  • Cutout: 92 x 92mm(W x H)


ApplicationsDC rectifier systems, Battery panels, DC distribution solar panels, DC loads, DC motors.

Regular Models

Model Function Source Voltage Display Parameters Input Voltage Over-All Dimensions Cut-Out Dimensions
SNM-02 DC Multi Function meter 24V-48V DC load 2-V, A, KW, KWh, MWh, LH, load 3- V, A, KW, KWh, MWh, LH, Old-KWh, MWh, LH (load1, Load2, load 3), communi-cation-Communication status, Dev Id 21V DC to 50V DC 96 x 96 x 95.5mm 92 x 92 mm
SNM-01 DC Multi Function meter 85V-270V AC / DC load 1-V, A, KW, KWh, MWh, LH 80V DC to 220V DC 96 x 96 x 95.5mm 92 x 92 mm
SNM-03 DC Multi Function meter 85V-270V AC / DC V, A, KW, KWh, MWh, LH, OLd KWh, OLd MWh, OL, DEV Id 5V DC to 1000V DC 96 x 96 x 95.5mm 92 x 92 mm

Optional Models

Model Function Source Voltage Display Parameters Input Voltage Over-All Dimensions Cut-Out Dimensions
DCM-01 Bi-Directional Solar Energy Meter 85V-270V AC / DC Main-V, ±A, ±KW, F-KWh, F-MWh, F-Load on Hours, RA, R-KW, R-KWh, R-MWh, R-Load on Hours, Device ID & Communication Status , Old Energy - F-KWh, F-MWh, F-Load on Hours, R-KWh, R-MWh, R-Load on Hours 5V DC to 1000V DC 96 x 96 x 95.5mm 92 x 92 mm
View Complete Details

AC Multifunction Meter

Features :

  • Microcontroller based multifunction AC Energy Meter.
  • Accuracy Class1.0 / (Class 0.5 calibration on Request).
  • CT /PT (Pri/Sec) Programmable.
  • Digital Measurement.
  • IEC 62052-11 IEC 62053-21 IEC 62053-22 IEC 62053-23.
  • RS 485 Serial Port with Modbus RTU Output.
  • Flush / Panel Mounting.
  • 96 x 96 mm DIN Mounting.
  • Auto Scroll / Hold Facility.
  • Internal Resettable fuse for protection of device against voltage fluctuations.
  • Protection from dust and water as per IP-51.


Dimensions :

  • Overall: 96 * 96 * 95.5mm (W x H x D)
  • Cut-out: 92 * 92mm (W x H)


ApplicationsSub metering panels, Distribution Panels, HT/ LT panels, DG panels etc.

Regular Models

Model Function Source Voltage Display Parameters Over-All Dimensions Cut-Out Dimensions
EMS-09 Basic / Energy Meter 85V to 270 V AC/DC V(R,Y,B), V(RY,YB,BR), A(R,Y,B), Hz, PF(R,Y,B,T), W(R,Y, B,T), KWh, MWh, LH, OKWh, OMWh, OL, Device ID (Communication Status) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-01 3 Phase Multi Function Meter with RS 485 85V to 270 V AC/DC Basic-V(R,Y,B), V(RY,YB,BR), A(R,Y,B), Hz, PF(R,Y, B,T), Phase Angle(R,Y, B), RPM, W(R, Y, B,T), VAr(R,Y, B,T), VA(R,Y, B, T), Device ID (Communication Status),Total-KWhT, KVrhCT, KVrhIT, KVAhT, LT (Load Hours Total),Import-KWhI, KVrhCI, KVrhII, KVAhI, LI (Load Hours Import),Export-KWhE, KVrhCE, KVrhIE, KVAhE, LE (Load Hours Export),Old-Total-KWhT, KVrhCT, KVrhIT, KVAhT, LT (Load Hours Total),Old-Import-KWhI, KVrhCI, KVrhII, KVAhI, LI (Load Hours Import),Old-Export-KWhE, KVrhCE, KVrhIE, KVAhE, LE (Load Hours Export). 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-01x 3 Phase Multi Function Meter with wifi 85V to 270 V AC/DC Basic-V(R,Y,B), V(RY,YB,BR), A(R,Y,B), Hz, PF(R,Y, B,T), Phase Angle(R,Y, B), RPM, W(R, Y, B,T), VAr(R,Y, B,T), VA(R,Y, B, T), Device ID (Communication Status),Total-KWhT, KVrhCT, KVrhIT, KVAhT, LT (Load Hours Total),Import-KWhI, KVrhCI, KVrhII, KVAhI, LI (Load Hours Import),Export-KWhE, KVrhCE, KVrhIE, KVAhE, LE (Load Hours Export),Old-Total-KWhT, KVrhCT, KVrhIT, KVAhT, LT (Load Hours Total),Old-Import-KWhI, KVrhCI, KVrhII, KVAhI, LI (Load Hours Import),Old-Export-KWhE, KVrhCE, KVrhIE, KVAhE, LE (Load Hours Export). 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-01T 3 Phase Multi Function Meter with THD 85V to 270 V AC/DC THD (available in EMS-01T)-Voltage (%) (R, Y, B), Ampere (%) (R, Y, B) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-17 Dual Source Energy Meter 85V to 270 V AC/DC V(R,Y, B), V(RY,YB, BR), A(R,Y,B), Hz, PF(R,Y, B,T), RPM*, Phase angle(R, Y, B), W(R,Y, B,T), KWh(M), MWh(M), KVAh(M), LH(M), KWh(G), MWh(G), LH(G) All energy parameters are available in-Mains(M) and generator mode(G), KVA, KVAh(G&M) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-03 KWH Meter 85V to 270 V AC/DC W(T), PF(T), KWh, MWh, Device ID (Communication Status) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-09m Basic /Energy Meter with 2 Event Counter 85V to 270 V AC/DC V(R,Y,B), V(RY,YB,BR), A(R,Y,B), Hz, PF (R,Y, B,T), W(R,Y,B,T), V A, KVAh, KWh, MWh, LH, Device ID (Communication Status) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
View Complete Details

Maximum Demand Controller

Features :

  • Measurement of basic, power, energy and demand parameters.
  • On-site programmable PT and CT ratios.
  • High brightness LED display (alpha numeric for parameter, numeric for value).
  • Automatic CT reverse correction for energy and demand.
  • Programmable demand techniques : block / sliding window.
  • Programmable demand parameters : Apparent / Active power.
  • Programmable demand range : Kilo / Mega.
  • Programmable Alarm / hysterisis settings.
  • Program RTC time to match EB meter's clock.
  • For EMS-15C : Max. Demand Controller = Max. demand indicator + Relay module (4 relay) (RR-4).
  • 4 control outputs for alarm and trip settings.


Dimensions :

  • Overall : EMS 15, EMS 15C 96 x 96 x 117mm (W x H x D)
  • RR-4 : 195x90x59mm(WxHxD) Cutout: 92 x 92mm(W x H)


Applications : In-comer distribution panels

Regular Models

Model Function Source Voltage Display Parameters Over-All Dimensions Cut-Out Dimensions
EMS-15C Maximum Demand Indicator 85V to 270V AC / DC Power-PF(R, Y, B, T), W(R, Y, B, T), VAr(R, Y, B,T), VA(R, Y, B, T) , Integral - KWh, KVArh-C, KVArh-l, KVAh, LH,Demand - Md (Fixed / Sliding), Md Time (Fixed / Sliding), Wd (Fixed / Sliding), Rd (Fixed), Elapsed Time (Fixed / Sliding) 96 x 96 x 95.5mm 92 x 92 mm
EMS-15 Maximum Demand Controller 85V to 270V AC / DC Basic-V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz, RTC Time 96 x 96 x 95.5mm 92 x 92 mm
View Complete Details

Dual Point Temperature Controller

Features :

  • Universal Input (J, K, PT-100) Selectable.
  • Wide Voltage Range.
  • ON / OFF or Self-Tuned Function Selectable.
  • Single / double set point.
  • Over Voltage Protection
  • LED Indication for sensor selected, function and relay status
  • Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua


Dimensions :

  • Overall : 48 x 48 x 95.5mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D)
  • Cut-out : H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H)


ApplicationsAny 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes and escalators etc.

Regular Models

Model Function Source Voltage Sensor Range Output Over-All Dimensions Cut-Out Dimension
EX9-MU Multi function Temperature Controller On-OffForward and Reverse Type (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C , 0 C - 400 C relay 1 - 1c/o, 5A relay 2 - 1c/o, 3A 96 x 96 x 95.5mm 92 x 92mm
EX9-MU-RS Multi function Temperature Controller On-Off - Forward and Reverse Type (Single/ Dual Set Point)with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
H3TX-U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C ,0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 48 x 48 x 95.5mm 46 x 46mm
EX9-U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C , -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
H3TX-2U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off 0 C - 600 C , 0 C - 1200 C, 0 C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive, 12V DC to drive SSR 48 x 48 x 95.5mm 46 x 46mm
EX9-2U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 400 C,-100 C - 400 C 1 relay 1c/o, 5A resistive, 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
H3TX-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C , 0 C - 300 C 2 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-2A-U On-Off - Alarm type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2A-U On-Off - Alarm type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2A-U On-Off - Alarm type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-MU Multi function Temperature Controller On-OffForward and Reverse Type (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C , 0 C - 400 C relay 1 - 1c/o, 5A relay 2 - 1c/o, 3A 48 x 48 x 95.5mm 46 x 46mm
H3TX-MU-RS Multi function Temperature Controller On-Off - Forward and Reverse Type (Single/ Dual Set Point)with SSR and Relay output   85V to 270V AC / DC J K PT-100 (Self-Tune)* PT-100 (On-Off 0 C - 600 C,0 C - 1200 C,0 C - 300 C,-100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 48 x 48 x 95.5mm
View Complete Details

Power Monitoring Device

Features :

  • Front button for resetting in manual mode
  • External potential free (zero volt /no voltage) terminal contacts for auto mode.
  • LED indication for relay status
  • Window displays the type of fault that has occurred during unhealthy condition
  • Trip delay time and limits for each parameter can be set digitally
  • All programs can be locked by removing short link across specified terminals
  • Unwanted parameters can be by-passed as per user's choice.
  • Relay can be configured to have NO or NC status during healthy condition
  • Unit will retain fault till accepted in manual mode
  • PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
  • Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
  • PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting
  • PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)
  • Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
  • User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
  • User can set the in-rush time delay.
  • Terminals to connect all the 3 phase CTs are provided.
  • CT primary can be programmed up to 500 in steps of 5. CT secondary will be factory set for 5
  • PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting
  • Din sized enclosure with Auto / manual Switch


Dimensions :

  • Overall : PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G, – 76 x 78 x 115mm (W x H x D)
  • Cut-out : PVMD, PVIMD– 92 x 92mm (W x H)


Applications : Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators

View Complete Details

Digital Time Switch

Features :

  • Switches On and Off 4 times in a day with respect to real time.
  • LED indication for relay status, LCD display for real time clock.
  • User friendly programming with manual over ride facility.
  • Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC.
  • For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries
  • For TS-203R : Built in Rechargeable Battery


Dimensions :

  • TS-203 :Over-all:72 x 72 x 84mm (W x H x D)
  • TS-203B : Over-all:110 x 86 x 68mm (L x W x D)


Applications : Street lightings, advertising sign boards etc.

Regular Models

Model Function Source Voltage Output Over-All Dimensions Cut-Out Dimensions
TS-203 Digital Daily Time Switch with 4 Program 240V AC 1 C/o, 16A resistive 72 X 72 X 84mm (W X H X D) 69 X 69mm (W X H )
TS-203B Digital Daily Time Switch with 4 Program 240V AC 1 C/o, 16A resistive 110 X 86 X 68mm (W X H X D) NA
TS-203R Digital Daily Time Switch with 4 Program 240V AC 1 C/o, 16A resistive 72 X 72 X 84mm (W X H X D) 69 X 69mm (W X H )
View Complete Details

Power Supply Module

Features :

  • Compact, light weight and SMPS design
  • Versatile and easy snap-on mounting on Din-rail
  • Very low ripple and noise
  • Regulated and adjusted output
  • Protection against over voltage, short circuit and over load.


Dimensions :

  • Overall : MS-01 - 45 x 75 x 116mm, MS-02 – 110 x 86 x 71mm
  • MS-03 - 155 x 88 x 79mm
  • MS-04 - 172x150x78mm MS-05 – 22.5 x 75 x 97mm (W x H x D)


Applications : PLC, DC Panels, DC Solenoids, DC Relay boards, Battery Charging Panels.

Regular Models

Model Function Input Voltage Output Over-All Dimensions
MS-01 Switch Mode Power Supply 192V - 264V AC 24V DC, 1A, 24W/ 12V DC, 1A, 12W 45.5 x 77.4 x 116mm
MS-03 Switch Mode Power Supply 170V - 300V AC 24V DC, 5A, 120W 155 x 88 x79mm
MS-05 Switch Mode Power Supply 170V - 300V AC 5V DC, 1A, 5W 22.5 x 75 x 96.5mm
MS-02 Switch Mode Power Supply 170V - 300V AC 24V DC, 2.1A, 50W / 24V DC, 1.46A, 35W / 24V DC, 1.04A, 25W / 24V DC, 0.63A, 15W /15V DC, 2.1A, 31.5W 12V DC, 4.2A, 50W / 12V DC, 2.9A, 35W / 12V DC, 2.08A, 25W / 12V DC, 1.25A, 1 5W /5V DC, 6A, 30W / 5V DC, 5A, 25W /5V DC, 3A, 15W 110 x 86 x 71mm
View Complete Details

Portable Tachometer

Features :

  • Micro-controller based design with world class Indian software.
  • Non-contact sensing through reflected light beam on reflective sticker.
  • LCD display
  • Input sensing indication through LED.
  • Memory facility to retain measured value.
  • Portable, lightweight, strong and elegant ABS enclosure.
  • Accuracy: 1RPM up to 5, 000 RPM and 0.05% of the reading above 5, 000 RPM.
  • Resolution: 0.1RPM up to 5, 999 RPM and 1RPM at and above 6, 000RPM.
  • Calibration certificate provided along with tachometer - traceable to national and international standards.


Dimensions : Over-all: 72 X 170 X 38mm (W X H X D).

Applications : Motors, Pumps, Generators, Engines and many more.

View Complete Details

Pre Set Counter

Features :

  • Din sized enclosure for panel mounting.
  • Wide Voltage range
  • Front / Rear reset facility provided.
  • Hold / Restart options (selectable) during power failure.
  • Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc
  • Over-voltage protection
  • CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value.
  • Preset Counts can be programmed with the help of thumbwheel switch
  • H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value
  • Input sensitivity – programmable (1-100Hz)
  • Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.


Dimensions : Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D)

Applications : Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more.

View Complete Details

16 Window Annunciator

Features :

  • Sleek, light weight, ABS enclosure
  • Super bright, White color SMD, LED for fault indications
  • Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
  • Multiple units terminals can be connected in parallel to achieve more windows
  • Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
  • Windows with different colours (Red, Green, Amber and White) can be supplied on request.
  • Above program can be locked by removing the short link across specified terminals


Dimensions :

  • Overall: M2-12, M2-16, M2-20, M2-24: 291 x 186.5 x 79mm (W x H x D)
  • Cut-out: M2-12, M2-16, M2-20, M2-24: 285 x 181mm(W x H)


ApplicationsC & R panels, Transformer panels, DG set panels, Fire annunciation panels and Instrumentation panels etc.

Regular Models

Model No of Windows Source Voltage Stand By Voltage Output Input Product Size Over-All Dimensions Cut-Out Dimensions
M2-6 6 Windows 85V to 270V AC/DC (or) 18V to 90V AC/DC N A 2 relays 1c/o (C-NO), (trip / Alarm) 6 potential free fault inputs 2 windows:- 66 x 27.5mm, 4 windows:- 31.5 x 27.5mm 73.5 x 142.5 x 78 mm (W x H x D) 69 x 141 mm (W x H )
M2-12 12 Windows 85V to 270 V AC/DC 12V DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free fault inputs 63 x 28mm 291 x 187 x 79mm (W x H x D) 285 x 181mm (W x H )
M2-16/16a 16 Windows 85V to 270 V AC/DC 12V DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free fault inputs 28 x 28mm & 63 x 28mm 291 x 187 x 79mm (W x H x D) 285 x 181mm (W x H )
M2-20 20 Windows 85V to 270 V AC/DC 12V DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 20 potential free fault inputs 28 x 28mm & 63 x 28mm 291 x 187 x 79mm (W x H x D) 285 x 181mm (W x H )
M2-24 24 Windows 85V to 270 V AC/DC 12V DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free fault inputs 28 x 28mm 291 x 187 x 79mm (W x H x D) 285 x 181mm (W x H )
M3-20(R)/M3-24(R) 20/24 Windows 85V to 270V AC / DC 12V DC / 85-270V AC/DC 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 2 Relays AC Fail (C, NO)/DC Fail (C, NO) 20/24 potential free fault inputs 3D 216 x 144 x 121mm (W x H x D) 212 x 139mm (W x H )
M3-8(C)/M3-16(C) 8/16 Windows 85V to 270V AC / DC NA 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 8/16 potential free fault inputs 2D 144 x 144 x 121mm (W x H x D) 139 x 139mm (W x H )
M3-4(R)/M3-6(R)/M3-8(R) 4/6/8 Windows 85V to 270V AC / DC 12V DC / 85-270V AC/DC 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 2 Relays AC Fail (C, NO)/DC Fail (C, NO) 4/6/8 potential free fault inputs 1D 72 x 144 x 121mm (W x H x D) 66 x 139mm (W x H )
M3-4(C)/M3-8(C) 4/8 Windows 85V to 270V AC / DC NA 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 4 /8 potential free fault inputs 1D 72 x 144 x 121mm (W x H x D) 66 x 139mm (W x H )
M3-16(R) 16 Windows 85V to 270V AC / DC 12V DC / 85-270V AC/DC 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 2 Relays AC Fail (C, NO)/DC Fail (C, NO) 16 potential free fault inputs 2D 144 x 144 x 121mm (W x H x D) 139 x 139mm (W x H )
M2-4 4 Windows 85V to 270V AC/DC (or) 18V to 90V AC/DC N A 2 relays 1c/o (C-NO), (trip / Alarm) 4 potential free fault inputs 66 x 27.5mm 73.5 x 142.5 x 78 mm (W x H x D) 69 x 141 mm (W x H )
M2-8 8 Windows 85V to 270V AC/DC (or) 18V to 90V AC/DC N A 2 relays 1c/o (C-NO), (trip / Alarm) 8 potential free fault inputs 31.5 x 27.5mm 73.5 x 142.5 x 78 mm (W x H x D) 69 x 141 mm (W x H )
M3-12(C)/M3-24(C) 12/24 Windows   85V to 270V AC / DC NA 2 Relays Trip Relay (C-NC-NO), Alarm Relay (C-NC-NO). 12/24 potential free fault inputs 3D 216 x 144 x 121mm (W x H x D)

Optional Models

Model No of Windows Source Voltage Stand By Voltage Output Input Product Size Over-All Dimensions Cut-Out Dimensions
M2-12/16a/ 20/24 12/16/20/24 Windows 24-48V DC 12V DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC/DC Fail) 12/16/20/24 potential free fault inputs M2-12: 63 x 28mm , M2-16 : 63 x 28mm 28 x 28mm, M2-24: 28 x 28mm 73.5 x 142.5 x 78mm (W x H x D) 285 x 181mm (W x H )
M2-12/16/24 12/16/24 Windows 24-48V DC 85-270V AC/DC 2 relays 1c/o (NC-C-NO), (trip/Alarm), 2 relays 1c/o (C-NO) (Hooter, AC/DC Fail) 12/16/24 potential free fault inputs M2-12: 63 x 28mm , M2-16 : 63 x 28mm 28 x 28mm, M2-24: 28 x 28mm 73.5 x 142.5 x 78mm (W x H x D) 285 x 181mm (W x H )
M2-12R /16R/24R 12/16/24 Windows 85-270V AC/DC 12V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm) 2 relays 1c/o (C-NO) (Hooter, AC Fail) RS 485 Port 12/16/24 potential free fault inputs M2-12R: 63 x 28mm M2-16R: 63 x 28mm, 28 x 28mm ,M2-24R: 28 x 28mm 73.5 x 142.5 x 78mm (W x H x D) 285 x 181mm (W x H )
M2-2 2 Windows   85V to 270V AC/DC 18V to 90V AC/DC NA 2 relays 1c/o (C-NO), (trip / Alarm) 2 potential free fault inputs 66 x 58mm 73.5 x 142.5 x 78mm (W x H x D)
View Complete Details

ATM Time Switch

Features :

  • Battery operated (2nos x 1.5V DC, AA size) Real Time Clock in 24 hour format.
  • Switches On and Off 4 times in a day with respect to real time


Dimensions : 110 X 86 X 68mm

Applications :  ATM air conditioners

View Complete Details

Basic Energy Meter

Features :

  • High brightness red LED display
  • On site programmable CT(pri &sec) ratio
  • Protection from dust and water as per IP-51 for front facia
  • Measurement of basic parameters
  • Program enable /disable facility available
  • EMS-11: Measurement of current parameters (L-N) *CT primary and secondary programmable.
  • EMS-12: Measurement of voltage parameters *PT primary and secondary programmable.
  • EMS-13: Measurement of frequency parameter.
  • EMS-14: Measurement of Power Factor parameter.
  • EMS-18: VAF Meter with True RMS Sensing
  • EMS-18: Measurement of basic parameters.(Current (L-N), Voltage (L-N), (L-L), frequency (average) and Power factor (Total) * CT ratio programmable, RS485 Mod-bus RTU protocol available, Sensing : True RMS.
  • Hold/Scroll Facility available.


Dimensions :

  • For EMS-11, EMS-12, EMS-13, EMS-14 Overall: 96 x 96 x 97.5mm (W x H x D) * Cutout : 92 x 92mm (W x H)
  • For EMS-02, EMS-18 Overall: 96 x 96 x 117 mm (W x H x D) * Cutout : 92 x 92mm (W x H)


ApplicationsSub metering, machines, Panels, power analysis systems etc.

Regular Models

Model Function Source Voltage Display Parameters Over-All Dimensions Cut-Out Dimensions
EMS-11 Ammeter 240V AC/ 110V AC A(R, Y, B) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-12 Voltmeter 240V AC/ 110V AC V(R, Y, B), V(RY, YB, BR) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-13 Frequency Meter 240V AC/ 110V AC Hz. (Avg) 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
EMS-18 VAF Meter 85V - 270V AC / DC V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz 96 x 96 x 95.5mm (W x H x D) 92 x 92 mm (W x H)
View Complete Details

Digital Monitoring Device

Features :

  • Front button for resetting in manual mode
  • External potential free (zero volt /no voltage) terminal contacts for auto mode.
  • LED indication for relay status
  • Window displays the type of fault that has occurred during unhealthy condition
  • Trip delay time and limits for each parameter can be set digitally
  • All programs can be locked by removing short link across specified terminals
  • Unwanted parameters can be by-passed as per user's choice.
  • Relay can be configured to have NO or NC status during healthy condition
  • Unit will retain fault till accepted in manual mode
  • PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
  • Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
  • PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting
  • PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)
  • Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
  • User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
  • User can set the in-rush time delay.
  • Terminals to connect all the 3 phase CTs are provided.
  • CT primary can be programmed up to 500 in steps of 5. CT secondary will be factory set for 5
  • PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting
  • Din sized enclosure with Auto / manual Switch


Dimensions :

  • Overall : PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G, – 76 x 78 x 115mm (W x H x D)
  • Cut-out : PVMD, PVIMD– 92 x 92mm (W x H)


Applications : Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators

Regular Models

Model Function Input Voltage Output Over-All Dimensions Cut-Out Dimension
PVMD Phase Voltage Monitoring Device 415V AC 3 phase, 4 wire, Self powered 1 c/o, 10A resistive 96 x 96 x 95.5mm 92 x 92mm
PVMD-G Phase Voltage Monitoring Device 415V AC 3 phase, 4 wire, Self powered 1 c/o, 10A resistive 76 x 78 x 115mm NA
PVIMD Phase Voltage Current Monitoring Device 415V AC 3 phase, 4 wire, Self powered 1 c/o, 10A resistive 96 x 96 x 95.5mm 92 x 92mm
PVIMD-G Phase Voltage Current Monitoring Device 415V AC 3 phase, 4 wire, Self powered 1 c/o, 10A resistive 76 x 78 x 115mm NA
PVIMD-R Phase Voltage Current & Energy Monitoring Device 415V AC 3 phase, 4 wire with RS485 415V AC 3 phase, 4 wire & auxiliary supply 85-270 V AC/DC 2 c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
RPD-01 Reverse Power Device 85-270V AC, self powered 1c/o, 5A 76 x 78 x 115mm NA
View Complete Details

Single Point Temperature Controller

Features :

  • 31/2 digit, 7segment LED temperature display
  • Wide voltage range (85-270V AC / DC)
  • Universal input (J / K / PT-100)
  • LED indication for sensor, funtion & relay status.
  • Sensor and function lock.
  • Dual function (On / Off or Self tuned).
  • Single set point with relay output.
  • Over voltage protection.
  • H3TX-Ua / TX7-Ua / EX9-Ua/H3TX-U-RS : Single display for both process and set value.
  • Temperature offset calibration user settable
  • Single set point with relay output
  • H3TX-2U / TX7-2U / EX9-2U : Dual display for process and set value.


Dimensions :

  • Overall : H3TX Models 48 x 48 x 95.5mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D)
  • Cut-out : H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H)


Applications : Furnace, Heat treatment equipment, Ovens, Boilers, Plastic and Rubber machinery and many more.

Regular Models

Model Function Source Voltage Sensor Range Output Over-All Dimensions Cut-Out Dimension
H3TX-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 0C - 400 C, -100 C - 400 C 1 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
EX9-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 0C - 400 C, -100 C - 400 C 1 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
EX9-MU Multi function Temperature Controller On-OffForward and Reverse Type (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C ,0 C - 1200 C , 0 C - 400 C relay 1 - 1c/o, 5A relay 2 - 1c/o, 3A 96 x 96 x 95.5mm 92 x 92mm
H3TX-MU-RS Multi function Temperature Controller On-Off - Forward and Reverse Type (Single/ Dual Set Point)with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C,0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 48 x 48 x 95.5mm 46 x 46mm
H3TX-U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 48 x 48 x 95.5mm 46 x 46mm
H3TX-2U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C , 0 C - 400 C, -100 C - 400 C 1 relay 1c/o, 5A resistive, 12V DC to drive SSR 48 x 48 x 95.5mm 46 x 46mm
H3TX-MU Multi function Temperature Controller On-OffForward and Reverse Type (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C , 0 C - 400 C relay 1 - 1c/o, 5A relay 2 - 1c/o, 3A 48 x 48 x 95.5mm 46 x 46mm
EX9-MU-RS Multi function Temperature Controller On-Off - Forward and Reverse Type (Single/ Dual Set Point)with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
EX9-U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C, -100 C - 400 C 2 relay 1C/o, 5A resistive 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
EX9-2U-RS On-Off / Self-Tune Function (Single Set Point) with SSR and Relay output 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C ,0 C - 1200 C , 0 C - 400 C, -100 C - 400 C 1 relay 1c/o, 5A resistive, 12V DC to drive SSR 96 x 96 x 95.5mm 92 x 92mm
TX7-Ua On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 0C - 400 C,-100 C - 400 C 1 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
H3TX-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C,0 C - 1200 C, 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C ,0 0 C - 1200 C , 0 0C - 400 C , -100 C - 400 C 1 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2U On-Off / Self-Tune Function (Single Set Point) 85V to 270V AC / DC J K PT-100 (Self-Tune) Hysterisis not applicable , PT-100 (On-Off) 0 C - 600 C,0 C - 1200 C,0 0C - 400 C,-100 C - 400 C 1 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C ,0 C - 1200 C , 0 C - 300 C 2 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2H-U On-Off - Heater type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C , 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 96 x 96 x 95.5mm 92 x 92mm
H3TX-2A-U On-Off - Alarm type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 48 x 48 x 95.5mm 46 x 46mm
TX7-2A-U On-Off - Alarm type Function (Dual Set Point) 85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C , 0 C - 300 C 2 relay 1c/o, 5A resistive 72 x 72 x 128mm 69 X 69mm
EX9-2A-U On-Off - Alarm type Function (Dual Set Point)   85V to 270V AC / DC J K PT-100 (On-Off) 0 C - 600 C, 0 C - 1200 C, 0 C - 300 C 2 relay 1c/o, 5A resistive 96 x 96 x 95.5mm
View Complete Details

Pneumatic Cylinder

  • Type Pneumatic Cylinders
  • Material Silicone Rubber
  • Shape Round
  • Thickness 10-20mm
  • Feature Fine Finish, Good Quality, Robust Construction
  • Country of Origin India
View Complete Details

Pneumatic Pressure Switch

  • Max. Current 10-15Amps
  • Packaging Type Plastic Packet
  • Cable Length 15-30mm
  • Output 15-20ma
  • Working Pressure 12kg/cm2
  • Usage Switching USe, Laboratory
  • Specialities Optimum Efficiency, Adjustable, Accuracy
View Complete Details

Pneumatic Pressure Gauge

  • Packaging Type Corrugated Boxes
  • Dial Size 8 Inch
  • Application Liquid Pressure, Air Compressor
  • Specialties Rust Proof, Perfect Strength, Easy To Fit
  • Diameter in mm 20-40mm
  • Liquid Pressure in Bar 0-500 Bar
View Complete Details

Photo Relay

Features :

  • Designed for the control of cotton level in laminae duct in ERM cleaners.
  • Designed for Industrial Environment
  • High Intensity pulsed Infra Red Emitter
  • Time Delay up to 20 Seconds.
  • Highly immune to Ambient Light
  • 45mm Din Rail mounting.


Dimensions : Overall:45 x 75 x 116mm (W x H x D)

Applications : Designed for control of cotton level in laminae duct in ERM cleaners and similar application.

Regular Models

Model Function Source Voltage Time Selection Output Over-All Dimensions
EALS-1003 Photo sensing & Control relay 240V AC 2Sec to 20Sec 1 C/O rated for 5A@ 250V AC/28VDC 145 x 75 x 116mm (W x H x D)
EAPRE-01 Photo sensing & Control relay - Emitter Probe NA NA NA 19.2 x 35.5 x 1257.5mm (W x H x D)
EAPR R-01 Photo sensing & Control relay - Receiver Probe NA NA NA 19.2 x 35.5 x 1257.5mm (W x H x D)
View Complete Details

Analog Monitoring Device

Features :

  • Din sized enclosure
  • Front button and external potential free (Zero volt/no voltage) terminal contacts for resetting in manual mode.
  • LED indication for power , relay status and fault condition.
  • *Trip delay time and limits of all parameters are factory set.
  • PMD-02, PMD-03: Monitors phase sequence, phase failure, and under voltage in a 3phase, 3wire system and trips under such conditions.
  • SPP-T: Monitors phase sequence, phase failure and phase unbalance in a 3phase, 3wire system and trips under such conditions.


Dimensions :

  • PMD-01 Over all : 45x75x116mm(WxHxD)
  • PMD-02 Over all : 22.5x75x102mm (W x H x D)


ApplicationsMotors, pumps, generators and Compressor panels etc.

Regular Models

Model Function Input Voltage Output Over-All Dimensions
ETR-01 Under Voltage Time Relay (ON Delay) 415V AC 3P/4W Self powered 5Min to 15 Min 17.5 X 89 X 62mm (W x H x D)
ETR-02 Under Voltage Time Relay (ON Delay) 230V AC 1C/O Relay 17.5 X 89 X 62mm (W x H x D)
PMD-02 Phase Sequence, Phase Failure, under voltage Monitor and Control 415V AC 3phase, 3 wire, Self powered 1 C/o, 5A resistive 22.5 x 75 x 96mm
PMD-03 Phase Sequence, Phase Failure, under voltage Monitor and Control 415V AC 3phase, 3 wire, Self powered 1 C/o, 5A resistive 17.5 x 89 x 62mm
PMD-01 Phase Unbalance, Phase Failure, Phase Sequence, Under Voltage, Monitor & Control 440V AC 3phase, 3 wire, Self powered 1 c/o, 5A resistive 45 x 75 x 116mm
SPP-T Phase Unbalance, Phase Failure, Phase Sequence, Monitor & Control 415V AC 3phase, 3 wire, Self powered 1 C/o, 5A resistive 45 x 75 x 116mm
View Complete Details

Control Transformer

  • Weight 5-10 Tons
  • Packaging Type Carton Box
  • Speciality Robust Construction, High Efficiency, Reliable
  • Material Stainless Steel
  • Shape Rectangle
  • Color Red
  • Voltage 220 V
View Complete Details

6 Window Annunciator

Features :

  • Sleek, light weight, ABS enclosure
  • Super bright, White color SMD, LED for fault indications
  • Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
  • Multiple units terminals can be connected in parallel to achieve more windows
  • Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
  • Above program can be locked by removing the short link across specified terminals
  • Available in 2, 4, 6 and 8 windows respectively
  • Available in wide auxiliary voltage ranges of 18V to 90V AC/DC and 85V to 270V AC/DC
  • Manual RESET and Auto RESET facility available
  • Windows with different colours (Red, Green, Amber and White) can be supplied on request.
  • Window size M2-4 – 66 x 27.5mm, M2-6 – Top 2 windows – 66 x 27.5mm, Bottom 4 windows – 31.5 x 27.5mm, M2-8 – 31.5 x 27.5mm (W x H)


Dimensions :

  • Overall:M2-4, M2-6, M2-8: 73.5 x 142.5 x 78 mm (W x H x D)
  • Cut-out: M2-4, M2-6, M2-8: 69 x 141 mm (W x H)


ApplicationsC & R panels, Transformer panels, DG set panels, Fire annunciation panels and Instrumentation panels and many more.

View Complete Details

8 Window Annunciator

Features :

  • Sleek, light weight, ABS enclosure
  • Super bright, White color SMD, LED for fault indications
  • Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
  • Multiple units terminals can be connected in parallel to achieve more windows
  • Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
  • Above program can be locked by removing the short link across specified terminals
  • Available in 2, 4, 6 and 8 windows respectively
  • Available in wide auxiliary voltage ranges of 18V to 90V AC/DC and 85V to 270V AC/DC
  • Manual RESET and Auto RESET facility available
  • Windows with different colours (Red, Green, Amber and White) can be supplied on request.


Dimensions :

  • Overall:M2-4, M2-6, M2-8: 73.5 x 142.5 x 78 mm (W x H x D)
  • Cut-out: M2-4, M2-6, M2-8: 69 x 141 mm (W x H)


ApplicationsC & R panels, Transformer panels, DG set panels, Fire annunciation panels and Instrumentation panels and many more.

View Complete Details

Light Switch

Features :

  • This is a light switch working on direct or reflective transmission principle.
  • It consists of high intensity emitter source and high sensitive receiver
  • The signal received from the receiver will operate a relay with ON delay or OFF delay depending on mode selected.
  • The time range can be 0.3 sec / 30 sec.


Dimensions :

  • EALS-4505 Dimension:45 x 75 x 116mm(WxHxD)
  • EALSR-01:19.2 x 35.5 x 127.5mm (W x H x D)
  • EALSE-01:19.2 x 35.5 x 127.5mm (W x H x D)


Applications : Hopper Feed Control, Stop Motion Device, Light Barriers, Level Control, Intrusion Alarm.

View Complete Details

Pneumatic Pulse Valve

1,350 /Piece Get Latest Price
  • Material Stainless Steel
  • Weight 0-150 Gm
  • Finishing Polished
  • Pressure 8-12 Kg/cm2
  • Temperature 0-50 Deg C
  • Automation Grade Automatic
View Complete Details

Drive Cooling Fan

  • Type Cooling Fans
  • Shape Round
  • Application Automobiles
  • Weight 500gm
  • Voltage 0-6vdc
  • Automatic Grade Automatic
  • Power 1-3kw
View Complete Details

Industrial Automation Sensor

  • Type Sensors
  • Material Plastic
  • Application Automobile Use
  • Power 15w, 20w
  • Warranty 2years
  • Alarm Range 2.5mtr
View Complete Details

24 Window Annunciator

Features :

  • Sleek, light weight, ABS enclosure
  • Super bright, Red color SMD, LED for fault indications
  • Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
  • Multiple units terminals can be connected in parallel to achieve more windows
  • Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
  • Windows with different colours (Red, Green, Amber and White) can be supplied on request.
  • Above program can be locked by removing the short link across specified terminals
  • Available in wide auxiliary voltage range of 85V to 270V AC / DC


Dimensions :

  • Overall: M2-12, M2-16, M2-20, M2-24: 291 x 187 x 79mm (W x H x D)
  • Cut-out: M2-12, M2-16, M2-20, M2-24: 285 x 181mm(W x H)


ApplicationsC & R panels, Transformer panels, DG set panels, Fire annunciation panels and Instrumentation panels etc.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us