Post Buy Requirement
GI

Global Infotech Solution

gstGST : 06ABLFM8932D1Z4 Verified Add Review

Our Products

  1. Computer Systems 26 Products available
  2. Motherboard 22 Products available
  3. Computer Cabinets 22 Products available
  4. Industrial PC 7 Products available
  5. LED Displays 4 Products available
  6. Computer Parts 3 Products available
  7. Laptops, Computers & Mainframes 3 Products available
  8. Infrared Thermometer & Thermal Camera Raw Materials

    2 Products available
  9. Industrial Grade Monitor

    2 Products available
  10. LCD Monitor

    2 Products available
  11. Others Products 7 Products available

Computer Cabinets

We offer a complete product range of ACP-2320 2U Rackmount Chassis, IPC-623 4U 20-Slot Rackmount Chassis, ACP-2000 2U 6-Slot Rackmount Chassis, IPC-940 4U Entry level Rack Mount Chassis and IPC-603MB 2U 3-Slot Rackmount Chassis

ACP-2320 2U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 10.7 kg (23.5 lb)
  • Form Factor 2U Rackmount
  • PS/2 1
  • Fan 2 (8 cm / 47 CFM each) + 1 (6 cm / 28 CFM) for SATA storage unit
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Non-Operating Vibration 2 G
  • Dimensions (W x H x D) 482 x 88 x 480 mm (19" x 3.46" x 18.9")
  • Hot-swap Drive Bay 2 (compatible with 3.5" or 2.5" devices)
  • LED Indicators Power, HDD, temperature, fan
  • Rear Panel Two 9-pin D-Sub openings
View Complete Details

IPC-623 4U 20-Slot Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 4U Rackmount
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Dimensions (W x H x D) 482 x 177 x 657 mm (19'' x 7'' x 26'')
  • LED Indicators Power, HDD, Temperature, FAN, and Power voltage Status
  • Power Supply 500W (Single)
  • System Fan 3 (12 cm/150 CFM)
View Complete Details

ACP-2000 2U 6-Slot Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 11.5 kg (25.3 lb)
  • Form Factor 2U Rackmount
  • PS/2 1
  • USB 2
  • Fan 2 (8 cm / 47 CFM each)
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Dimensions (W x H x D) 482 x 88 x 451 mm (19'' x 3.5'' x 17.8'')
  • Control Power / System reset / Alarm reset switch
  • Rear Panel One 9-pin D-Sub opening
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
View Complete Details

IPC-940 4U Entry Level Rack Mount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 14.5 kg (31.9 lb) / 14.2 kg (31.2 lb)
  • Fan 1 (12 cm / 85 CFM)
  • Air Filter Yes
  • LED Indicators Power and HDD activity
  • Control Power switch and system reset button
  • Rear Panel Motherboard version: Five 9-pin D-Sub & one 25-pin D-sub openings
  • Temperature 0 ~ 40 °C (32 ~ 104 °F)
  • Humidity 10 ~ 85 % @ 40 °C, non-condensing
  • Shock 10 G (with 11 ms duration, 1/2 sine wave)
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
View Complete Details

IPC-603MB 2U 3-Slot Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 2U Rackmount
  • 2 (8 cm /47 CFM each) 2 (8 cm /47 CFM each)
  • Air Filter Yes
  • LED Indicators Power status and HDD activity
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Vibration 1 Grms
  • Non-Operating Vibration 2 G
  • Power Supply 350W (Single)
View Complete Details

HPC-7242 2U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 13.7 kg (30.12 lb)
  • USB 3.0 2
  • System Fan 1 (8 cm/47 CFM) + 2 (6 cm/28 CFM) for SAS/SATA storage unit
  • Air Filter Yes
  • Operating Temperature 0 ~ 40° C (32 ~ 104° F)
  • Non-Operational Temperature -40 ~ 70° C (-40 ~ 156° F)
  • Operating Vibration 1 Grms
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Humidity 10 ~ 95% @ 40° C, non-condensing
View Complete Details

ACP-2020G 2U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 2U Rackmount
  • Air Filter Yes
  • LED Indicators Power, HDD
  • USB 2.0 2
  • System Monitoring Chassis intrusion switch
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Vibration (5 ~ 500 Hz) 0.5 Grms
  • Non-Operating Vibration (5 ~ 500 Hz) 2 Grms
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
View Complete Details

IPC-631 4U Front I/O Short Depth Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 4U Rackmount
  • Hot-swap Drive Bay 2 ( 2.5" SAS/SATA - Optional )
  • Fan 2 (12 cm / 82 CFM)
  • Air Filter Yes
  • LED Indicators Power status and HDD activity
  • Control Power switch and system reset button
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Dimensions (W x H x D) 482 x 177 x 348 mm (19'' x 7.0'' x 13.7'')
View Complete Details

IPC-941 348mm Depth 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 8.5 kg (18.7 lb)
  • Slim ODD 1
  • Fan 2 (9 cm / 53 CFM)
  • Air Filter Yes
  • LED Indicators Power, HDD, temperature, fan, LAN1, and LAN2
  • Rear Pane Motherboard version: Five 9-pin D-Sub and one 25-pin D-Sub openings
  • Shock 10 G (with 11 ms duration, half sine wave)
View Complete Details

ACP-4000 Quiet 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 15.2 kg (33.5 lb)
  • Form Factor 4U Rackmount
  • Air Filter Yes
  • Fan 2 (12 cm / 82 CFM)
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Dimensions 482 x 177 x 479 mm (19" x 7" x 18.9")
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
View Complete Details

ACP-4010 Quiet 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 16.6 kg (36.5 lb)
  • Form Factor 4U Rackmount
  • Air Filter Yes
  • Fan 2 (12 cm / 82 CFM)
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
  • LED Indicators Power, HDD, temperature, fan, LAN1, and LAN2
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
View Complete Details

IPC-610-H 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 15 kg ( 33 lb )
  • Form Factor 4U Rackmount
  • Fan 2 (12 cm / 82 CFM)
  • Air Filter Yes
  • LED Indicators Power, HDD and power voltage status
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
View Complete Details

ACP-4320 Quiet 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 4U Rackmount
  • 5.25 External Bay 2
  • 3.5 External Bay 1
  • Hot Swap External 2 (3.5" or 2.5")
  • Fan 1 (12 cm / 82 CFM) + 1 (6 cm / 28 CFM)
  • Air Filter Yes
  • LED Indicators Power, HDD, temperature, fan, LAN1, and LAN2
  • Remote Monitoring CPU/System fan speed , CPU/System temperature , motherboard voltage
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
View Complete Details

IPC-610-L 4U 15-Slot Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 4U Rackmount
  • Fan 1(12cm / 82CFM)
  • Air Filter Yes
  • LED Indicators Power status and HDD activity
  • Control Power switch and system reset button
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
  • Non-Operating Vibration 2 G
View Complete Details

IPC-611 4U 15-Slot Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 14.2 kg (31.2 lb)
  • Form Factor 4U Rackmount
  • System Fan 1 (12 cm , 82 CFM)
  • Air Filter Yes
  • LED Indicators Power status and HDD activity
  • Control Power switch and system reset button
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
View Complete Details

ACP-1010 1U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 8 Kg (17.6 Lb)
  • Form Factor 1U Rackmount
  • Operating-Temperature 0 ~ 45
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F)
  • Operating Humidity 10 ~ 85% @ 40° C, non-condensing
  • Non-Operating Humidity 10 ~ 95% @ 40° C, non-condensing
  • Dimensions (W x H x D) 480 x 44 x 497 mm (19
  • Control Power / System reset / Alarm reset switch
View Complete Details

ACP-2020 2U Rackmount Short Depth Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 8.6 kg ( 18.96 lbs )
  • Form Factor 2U Rackmount
  • USB 3.0 2
  • Power Supply 500W (Redundant)
  • Filter Yes
  • Fan 1 ( 8 cm / 41 CFM )
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Dimensions (W x H x D) 482 x 88 x 398 mm ( 18.96" x 3.46" x 15.67" )
View Complete Details

ACP-4020 Compact 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Form Factor 4U Rackmount
  • Air Filter Yes
  • Fan 2 (9 cm / 52 CFM)
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Operating Vibration (5 ~ 500 Hz) 1 Grms
  • Non-Operating Vibration (5 ~ 500 Hz) 2 Grms
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
  • Power Supply 500W (Single)
View Complete Details

ACP-4340 4U Rackmount Chassis

  • Form Factor 4U Rackmount
  • Hot Swap External 2 (3.5" or 2.5")
  • Fan 1 (12 cm / 82 CFM) + 1 (8 cm / 52 CFM)
  • LED Indicators Power, HDD, temperature, fan, LAN1, and LAN2
  • System Monitoring Chassis intrusion switch
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Dimensions (W x H x D) 482 x 177 x 479 mm (19" x 7" x 18.9")
  • Power Supply 500W (Single)
View Complete Details

IPC-510 Economical 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 10.7 kg (23.5 lb)
  • Form Factor 4U Rackmount
  • 5.25 External Bay 3
  • System Fan 1 (12 cm / 77 CFM)
  • Air Filter Yes
  • USB 2.0 2
  • LED Indicators Power status and HDD activity
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Dimensions (W x H x D) 481 x 175 x 446 mm ( 19" x 7" x 17.6" )
View Complete Details

HPC-7442 4U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 18.5 kg (40.68 lb)
  • Hot-swap Drive Bay 4 (compatible with 3.5" or 2.5" devices)
  • System Fan 1 (12 cm /114 CFM) + 1 (8 cm/55 CFM)
  • USB 2.0 10 D-sub openings supporting up to 10 COMs with optinal COM cables
  • LED Indicators Power, HDD, temperature, fan, LAN1, and LAN2
  • Rear Panel Five 9-pin D-Sub & one 68-pin SCSI openings
  • Remote Monitoring CPU/System fan speed , CPU/System temperature , motherboard voltage
  • Operating Shock 10 G (with 11 ms duration, half sine wave)
  • Dimensions (W x H x D) 482 x 177 x 600 mm (19" x 7.0" x 23.6")
View Complete Details

ACP-2010 2U Rackmount Chassis

  • Min. Order (MOQ) 1 Piece
  • Weight 10.7 kg (23.5 lb)
  • Form Factor 2U Rackmount
  • Fan 2 (8 cm / 47 CFM each)
  • Operating-Temperature 0 ~ 40° C (32 ~ 104° F) (Operational humidity: 40° C @ 85% RH Non-Condensing)
  • Non-Operating Vibration 2 G
  • Non-Operational Temperature -20 ~ 60° C (-4 ~ 140° F) and 40° C @ 95% RH Non-Condensing
  • Operating Vibration (5 ~ 500 Hz) 1 Grms
  • Dimensions (W x H x D) 482 x 88 x 480 mm (19" x 3.46" x 18.9")
  • Rear Panel Two 9-pin D-Sub openings
  • Remote Monitoring CPU/System fan speed, CPU/System temperature
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us