1 Products availableOur offered Product range includes Horizontal Cylindrical Autoclave, Autoclave Vertical Deluxe Sterilizer, Fully Automatic Cylindrical Autoclave, Portable Autoclave Sterilizer and Vertical Autoclave Sterilizer.
Gasket
Fitted with silicon rubber gasket.
Door
Sterilizers have single or double door made out or rolled steel lined with stainless steel sheet on both sides.
Component
Insulation
As per the international standards and guidelines our triple walled Horizontal autoclave have a working temperature of 121 C, however for specific requirements our autoclaves can be upgraded to be used for up to 134 C.
Pressure is adjustable from 15-20 psi.
Steam Generator
Available with separate boiler
Automation with Printing Facility
Quality & Standards
We are an ISO 9001:2008/WHO-GMP, CE, ISO, CE, ISO 13485:2003 Certified Company with Strict quality control measures conforming to National and International Standards.
Sizes
Size of Inner Chamber | Capacity in Liters | Load |
---|---|---|
400X600mm | 75 Liters | 6.00 KW |
450X600mm | 100 Liters | 6.00 KW |
400X1100mm | 138 Liters | 12.00 KW |
400X1200mm | 150 Liters | 12.00 KW |
500X900mm | 175 Liters | 12.00 KW |
500X1200mm | 220 Liters | 12.00 KW |
550X1250mm | 300 Liters | 12.00 KW |
600X1200mm | 355 Liters | 12.00 KW |
650X1200mm | 430 Liters | 12.00 KW |
Construction and Salient Features
Capacity
OPTIONS
Material of construction & silent Features
Gasket
Fitted with silicon rubber gasket.
Door
Sterilizers have single or double door made out or rolled steel lined with stainless steel sheet on both sides.
Component
Insulation
75MM gap between the wall is filled with special grade glass wool for proper insulation and to avoid heat losses.
Temperature & Power Supply
Steam Generator
Fully Automatic with PLC controller. Fitted with vacuum breaker to break vacuum in case of formation of vacuum due to steam condensation/Vacuum pump.
Automatic Low Water Level Cut-off Device fitted for general safety of the element.
Printing facility.
Quality & Standards
We are an ISO 9001:2008/WHO-GMP, CE, ISO, CE, ISO 13485:2003 Certified Company with Strict quality control measures conforming to National and International Standards.
Sizes
Size of Inner Chamber | Capacity in Liters | Load |
---|---|---|
400X600mm | 75 Liters | 6.00 KW |
450X600mm | 100 Liters | 6.00 KW |
400X1100mm | 138 Liters | 12.00 KW |
400X1200mm | 150 Liters | 12.00 KW |
500X900mm | 175 Liters | 12.00 KW |
500X1200mm | 220 Liters | 12.00 KW |
550X1250mm | 300 Liters | 12.00 KW |
600X1200mm | 355 Liters | 12.00 KW |
650X1200mm | 430 Liters | 12.00 KW |
Construction and Salient Features
Options
These are also available in sizes of 5 Liters. to 15 Liters. Non-Electric Models are also available.
Technical Details
Size of Inner | Capcity in Litter | |
---|---|---|
9X9 | Electric / Non-Electric | 9 Liters |
9X11 | Electric / Non-Electric | 11 Liters & 13 Liters |
9X12 | Electric / Non-Electric | 14 Liters |
9X13 | Electric / Non-Electric | 15 Liters |
12X11 | Electric / Non-Electric | 18 Liters & 20 Liters |
12X12 | Electric / Non-Electric | 23 Liters |
12X12 | Electric / Non-Electric | 26 Liters |
12X16 | Electric / Non-Electric | 30 Liters |
12X22 | Electric | 30 Liters |
Construction and Salient Features
OPTIONS
Sizes
Size of Inner Chamber | Capcity | Load |
---|---|---|
250X450MM | 22 LITERS | 2.0010/V |
300X500MM | 40 LITERS | 3.00 10/V |
350X550MM | 50 LITERS | 3.00 10/V |
400X600MM | 78 LITERS | 4.00 10/V |
450X600MM | 98 LITERS | 6.0010/V |
550X750MM | 250 LITERS | 6.0010/V |
Extra for Digital Timer | ||
Extra for Automatic Water Control | ||
Customized Size Available. |
Construction and Salient Features
Table top Bench-top, pre- and post-vacuum autoclave with an automatic temperature control system, self-test system before an operation, self-test mode diagnoses, fully automatic steam ejection and safety device containing safety valve, automatic sterilization cycles, and auto detections for steam sterilization of glass wares and plastic wares.
Specifications
Options
Sizes
Size of Inner Chamber ( WXHXD ) | Capcity in Liters | Load |
---|---|---|
450X450X900 mm | 180 Liters | 18 KYV |
450X600X900 mm | 240 Liters | 18 KYV |
600X600X900 mm | 320 Liters | 18 KYV |
600X600X1200 mm | 430 Liters | 27 KYV |
600X900X1500 mm | 810 Liters | 36 KYV |
900X1050X2100 mm | 1980 Liters | 48 KYV |
1050X1200X2100 mm | 2600 Liters | 60 KYV |
Application
Options
A High-speed model is also available (GTA-005-A)
Technical Details
Size of Inner Chamber | Capacity in Liters | Load |
---|---|---|
400X600mm | 78 Liters | 6.00 KW |
400X1100mm | 138 Liters | 12.00 KW |
500X900mm | 165 Liters | 12.00 KW |
500X1200mm | 220 Liters | 12.00 KW |
Construction Construction Robust and rugged all weld construction which is leak-proof, unlike riveted construction. Chamber and jacket are made of a thick plate of stainless steel of 316. Pass a hollow load (A) test (batch Monitoring System), High Vacuum compressor with recycling facility. Door The equipment provided with vertical sliding single/double door. The door is fabricated from SS 316 quality material, and sealing is done through a movable silicon gasket pressurized by compressed air. The pressure gauge is provided for a gasket. Insulation Glass wool Insulation to surface temperature of the sterilizer to be less than 45°C and it has low thermal conductivity and should not release any particles. Door Gasket Silicon Door gasket, and on commencement of the process, the door gasket is pressed against the rear face of the door by steam/air to ensure the doors remains closed during the process. Control System with Connectivity Fully automatic microprocessor controlled horizontal steam sterilizer. PLC-based system has 4-5 color touch-sensitive, LCD display interface. With battery back-up & non-volatile memories. Digital input/output controls, analog measuring inputs & ports for PC connectivity. Panel include various pressure and temp. Display for the depiction of actual pressure/temperature in the chamber, jacket, and on the gasket. Password Protection Monitoring & documentation system and multiple password access levels would be provided to control access/ operation of the machine preventing unauthorized access. Printer Equipped with built thermal printer. Door Safety The steam pressure in the boiler is indicated on an individual pressure gauge. Safety Lock for Door Every horizontal rectangular sterilizer is fitted with a SELF-LOCKING SAFETY DOOR, which cannot be opened when the chamber is under pressure. Alarms Automatic process checking & failure correction. Self-diagnosis and check the autoclave for the different audio/visual alarm situations. Other Safety Power to shut off heaters should water in the heating section falls below a preset level. The terminals & contacts are housed in a watertight cabinet. Electronic water saving control – condensing the exhaust chamber steam with drain system designed to prevent pollutants from entering water supply & sterilizer. Automatic process checking, and failure correction should be possible by the control system. The range of alarm should include over temperature pressure sensor failure, phase time out, doors not properly closed, power failure (less than 10 sec should be ignored), continuous self-checking of all the safety devices, low water level, water in the chamber, etc. should be possible. Steam Generator Separate Steam generator of suitable capacity for each sterilizer made of 316 Stainless Steel. Fitted with all safety & control devices. Steam Generator has automatic operation for water level control energizes the water pump and supply valve to ensure proper water level in the boiler drum . Vacuum Electric vacuum system consists of a multistage vacuum pump with a liquid ring that ensures air removal during the pre-vacuum stage. Temperature and Pressure Sensors Working temperature 121 °C to 134 °C To work on 440VAC, 50 Hz, 3 Phase Condensate free 97-100 % saturated vapor complete with piping, valves, and pressure relief etc., delivery at 50-80 PSIG pressure. Air Filter A disposable air filter provided by filtering the atmospheric air for entering inside the chamber. Cycle Designed to operate various programs. Apart from standard pre- programmed cycles, the special cycle should be programmed by an authorized supervisor code only. Programs Include Wrapped instruments, porous load 134°C / Heat Sensitive material, rubber, plastic, porous load 121 °C (working holding temperature 121°C to 134°C) Bowie & Dick test (7kg), PCD test/ Leak test and equipped with pre-vacuum, gravity and preferably with liquid cycle (121 °C Liquid cycle for liqui construction.
Sizes
Size of Inner Chamber ( WXHXD ) | Capcity in Liters | Load |
---|---|---|
450X450X900 mm | 180 Liters | 18 KYV |
450X600X900 mm | 240 Liters | 18 KYV |
600X600X900 mm | 320 Liters | 18 KYV |
600X600X1200 mm | 430 Liters | 27 KYV |
600X900X1500 mm | 810 Liters | 27 KYV |
Door with Safety Features
Opening methods of the door structure are the active door autoclave structure, hoist reducer gear by hand to open and close, and can be customized with an electric, pneumatic, or hydraulic hoist. The autoclave is equipped with a perfect safety interlock protection technology, ensuring the safe functioning of the appliance and the safety of the operator. Two types of opening ways for the users to choose one side the door open and open door up or down. Side-door structure with rotating arm. Rotating flexible, low-operating, easy opening; on the use of lever-type door open institutions, lever bottom connecting.We the “Genist Technocracy Pvt Ltd” is an organization committed to manufacturing and export of International quality Medical Equipment and Laboratory Equipments in India & abroad since 2004. We are dedicated to serve the Mankind and the Nation by providing World Class Medical Equipment and Laboratory Equipments at affordable prices.
GENIST TECHNOCRACY DEALS IN:
The vessel door, the top equipped weight unit device, open the type of lightweight, occupy small space for autoclave
Chamber Dimension & Temperature
Inside Diameter (mm) | 1000 |
---|---|
Effective Length (mm) | 1800mm/2400mm |
Design Temperature (0c) | 121°C-134°C |
Temperature Medium | Water |
Open-Door Fashion | Manual Operation |
Sealing | Pneumatic |
Control Panel | Automatic |
Premium Technologies
Applications
Size
Size of Inner Chamber (DiaxDepth)mm | Capcity(Ltr.) | Load |
---|---|---|
400X600mm | 78 Litter | 6.00 KW |
400X1100mm | 138 Litter | 12.00 KW |
500X900mm | 165 Litter | 12.00 KW |
500X1200mm | 220 Litter | 12.00 KW |
600X1200mm | 350 Litter | 15.00 KW |
Construction
Material of Construction of external body:
SS 304 or more external body with SS microwave applicator with microwave leakproof front cover. Inner microwave chamber construction: Specially designed rectangular chamber made of SS 316 Grade stainless steel.
Capacity
Specifications
With microwave sterilization, Genist machines are Ultracompact and completely automated. No prior segregation of waste is required. This equipment can transform all types of clinical by-products into sterilized, inert, and unrecognizable waste within its single, unique vessel. Once the biomedical waste has been processed, it can then be considered normal municipal waste without any biological risk to anyone handling it. Genist solutions provide traceability, safety, and a guaranteed level of sterilization. They can also provide a massive reduction in the cost of waste removal compared to other standard solutions (collection, incinerators, autoclaves, chemicals).
Customized Sizes Available as per Customer Requirement