Our Products
Surgical Needle
2 Products availableOur Complete range of products are Breast Localization Needle, Manifold Kit, Target Picc Catheter Kit, Ventilator Full Set and Path Finder Bulb Irrigator.
Key features
Ordering Information
A.V. fistula needles set are indicated for use in conjunction with a connector of Hemodialysis blood tubing set. AV Fistula Needles used to connect blood lines to the blood vessel through needle when dialysis is carried out via an internal fistula. Flexible butterfly wings are for proper fixation, Color coded wings for easy identification of needle sizes & Soft kink resistant Medical Grade PVC tubing.
Meditech is the leading supplier and manufacturer for highly quality Ventilator Circuits, and Ventilator Tube Circuit, which are made of medical Grade Corrugated PVC. Ventilator . Ventilator Circuit is provided with a recessed standard 22 mm Male / Male & 22 mm Male / Female adapter for flexibility throughout the critical care management.
Ergonomic design provides feel & balance of a high quality surgical instrument.
Stopcock manifolds provide a simple and reliable means of interfacing
multiple fluid or gas lines together using lure fittings.
Manifold are available in 2 , 3 , 4 Way (Right Off and Right On)
Cat No. | Diameter (G) | Length (cm) |
---|---|---|
IN 16 | 16 G | 7 cm |
IN 18 | 18 G | 7 cm |
IN 20 | 20 G | 4 cm |
Used through the channel of the endoscope to provide short durationinternal access for delivery of nutrition or medication to the small bowel.
Cat. No. | Description | Size |
---|---|---|
MTPICC 2 | Peripherally Inserted Central Venous catheter | 2 F |
MTPICC 4 | Peripherally Inserted Central Venous catheter | 4 F |
MTPICC 5 | Peripherally Inserted Central Venous catheter | 5 F |
Our special designed and manufactured disposable skin stapler is the specific instrument for surgical skin suture. Our skin stapler has the advantages of quick speed of sewing up during the operation, very less histological reaction, good wound matching and healing, small surgical scar, and no pain for removing, etc. Our disposable skin stapler enables you not to only work with higher efficiency, but also avoid cross-infection effectively.
Our designed Remover for skin stapler is specially used for the removing of skin staples with the feature easy structure and novel appearance.
Transducer protectors are used in Hemodialysis blood lines to keep the blood side of the circuit separated from the machine side and to prevent contamination of the machine by the blood flowing through the circuit. Transducer Protector is a good protective barrier for pressure monitoring during hemodialysis.
Indication For Use :
Med Plus Biopsy Needle is a disposable, spring-loaded, semi-automatic biopsy needle for biopsies from soft tissue such as prostate, kidney, liver, spleen lymph nodes and various soft tissue tumors. It is not appropriate for bone biopsies
Key features
Ordering Information
Product Code | Diameter, Length | Coaxial Needle Size |
---|---|---|
MAB – 1415 | 14G, 15 CM | 13G, 12.8 CM |
MAB – 1615 | 16G, 15 CM | 15G, 12.8 CM |
MAB – 1810 | 18G, 10 CM | 17G, 7.8 CM |
MAB – 1815 | 18G, 15 CM | 17G, 12.8 CM |
MAB – 1825 | 18G, 25 CM | —- |
MAB – 2010 | 20G, 10 CM | 19G, 7.8 CM |
MAB – 2015 | 20G, 15 CM | 19G, 12.8 CM |
Soft-Core biopsy instrument is available with compatible guiding cannula in various gauge and lengths for procuring multiple samples with single insertion.Coaxial biopsy needle.
Soft-Core Instrument Order Number |
Needle Gauge X Length (cm) |
Soft-Core CT Instrument Order Number |
Coaxial Needle X Length (cm) |
Colour |
---|---|---|---|---|
SC 1810 | 18 X 10 | SC 1810 CT | 7.8 | Pink |
SC 1816 | 18 X 16 | SC 1816 CT | 13.8 | Pink |
SC 1820 | 18 X 20 | SC 1820 CT | 17.8 | Pink |
SC 1825 | 18 X 25 | —- | — | Pink |
SC 1610 | 16 X 10 | SC 1610 CT | 7.8 | Purple |
SC 1816 | 16 X 16 | SC 1610 CT | 13.8 | Purple |
SC 1410 | 14 X 10 | SC 1410 CT | 7.8 | Green |
SC 1416 | 14 X 16 | SC 1416 CT | 13.8 | Green |
Meditech is the leading supplier and manufacturer for highly quality Ventilator Circuits, and Ventilator Tube Circuit, which are made of medical Grade Corrugated PVC. Ventilator. Ventilator Circuit is provided with a recessed standard 22 mm Male / Male & 22 mm Male / Female adapter for flexibility throughout the critical care management.
HME filters are passive humidification systems that retain heat and moisture from the patients exhaled gas via a hygroscopic filter. Bacterial Viral Filters help provide effective protection against various types of particles including bacteria, viruses, and moisture droplets.
Catheter Mounts are of great use to add extra length to the breathing system when needed. Meditech manufactured catheter mount is compatible with all Breathing and Ventilator circuits. Catheter Mounts is connected between the patient and the breathing system.
The catheter mount with double swivel connector and flexible tubing provides mobility and flexibility to the patient end of the circuit. The catheter mount is used as an intermediary connection between the patient and the breathing system.
These tubes are made of a special flexible co-polymer.
These tubes have a minimal compliance with low dead space volume. The catheter mount is fitted with a double swivel connector and flexible tubing.
Each catheter mount has a 22 mm female / 15 mm male end to connect to the breathing system and 15 mm female end to connect to the endotracheal tube or laryngeal mask. The length of the tubing is around 13 cm.
MFG
The Pathfinder bulb irrigator is the elegantly simple irrigation device that provides the physician the option of controlling the flow of irrigation. The result is greater accuracy and enhanced visualization during endoscopicprocedures.
Introducing TARGET Ports family of power Injectable ports for repeated treatments like chemotherapy and Compatible with C.T. The TARGET ports are constructed of a MRI compatible, lightweight engineering plastic that allows up to 5cc/sec power injection of contrast media for CECT scans.
A) TARGETA IMPLANTABLE C.T PORT ( FULL SIZE PORT FOR ADULT PATIENT)
Order Number | Order Number | Size | USE FOR |
---|---|---|---|
MTAP – 9.6 | Full size port with 9.6F attachable catheter | 9.6F | Adult Patient |
used for injection into & around bleeding vessels including varices. 2 position handle ensures safety. Handle clicks on needle extension. Luer lock handle.
Order No. | Diameter | Length (CM) |
---|---|---|
SN21-160 | 21 G | 160 cm |
SN23-160 | 23 G | 160 cm |
SN25-160 | 25 G | 160 cm |
SN21-230 | 21 G | 230 cm |
SN23-230 | 23 G | 230 cm |
HME filters are passive humidification systems that retain heat and moisture from the patients exhaled gas via a hygroscopic filter. Bacterial Viral Filters help provide effective protection against various types of particles including bacteria, viruses, and moisture droplets.
Skin marker is a medical pen used for marking on the patients skin before or during surgical procedures.
Size | Pigtail Type | Malecot Type |
---|---|---|
7F, 8F, 9F | P7, P8, P9 | —– |
10F, 12F, 14F | P10, P12, P14 | M10, M12, M14 |
16F, 18F | —– | M16, M18 |
Used to perform dual irrigating and tissue straining / collecting functionsduring transurethral, bladder and prostate surgery. Selfair purging design allows efficient and rapid tissue evacuation
Pre-Curved Code | Stright Ext. Code | Dscription |
---|---|---|
MDLKC-24 | MDLKS-24 | 14.5 Fx24cm Long Term Dual Lumen Catheter Kit |
MDLKC-28 | MDLKS-28 | 14.5 Fx28cm Long Term Dual Lumen Catheter Kit |
— | MDLKS-32 | 14.5 Fx32cm Long Term Dual Lumen Catheter Kit |
— | MDLKS-36 | 14.5 Fx36cm Long Term Dual Lumen Catheter Kit |
Hemodialysis Blood tubing set has been specially designed for the patient to connect external system which extracts patients blood to the dialyzer and then returns patients blood from the dialyzer. Hemodialysis Blood Lines specially used for continues blood supplies during Hemodialysis process. These Hemodialysis Blood line set are CE and ISO certificate made of medical grade PVC, non-toxic material. For hemodialysis process these blood lines act as the blood channel during blood purification treatment. Medical grade PVC tube, ensure the biggest safety on human body and can easily equipped with different dialysis machines.
Peel Apart Sheath Introducers facilitate the introduction of the catheter to the vein. If they fail to peel or are difficult to insert, complications may arise, making the procedure longer and more challenging.
Potential cost savings.Improved design may reduce the need to open a secondintroducer kit.
Inflation Device used for a wide array of applications such as balloon catheterization, stent deployment and fluid delivery. Inflation Device connected with 1200psi braided line and 3-way stopcock for interventional systems . Ergomic design, easy for holding and operating features of inflation device make it very user friendly.