Moving Die Rheometer

Elastic Modules, Tan Delta, Initial, Maximum Torque, Rotor less, Viscous Modus, Cure rate, Minimum torque, Scorch points, Smaller Sample size. Viscous and Elastic S Modulus (torques) can be separated, Choice of display S or tan and along with elastic Modulus, Automated Testing, Online Display of Torque vs. Time graph, Graphical Comparison of results. Other Features are as above. Sample Volume Approx. 6 CM^3, Oscillating Disc Frequency 100Cycles/Min (1.66Hz), Oscillating Amplitude +/- 0.5 Deg, 1 Deg, 3 Deg, and Microprocessor Temp. Controller Calibrated range 100200 Deg C., Air Pressure 60 PST, 4.2Kg/Cm2.

View Complete Details

Kinematic Viscosity Bath

The Viscosity Bath is designed to simplify ASTM D 445; IS-1206 kinematic viscosity testing. A top-mounted controller keypad permits quick entry of bath set point temperature while a sophisticated microprocessor PID Auto tuned controller controls the bath heating and stirring through flange top mounted motorized pump cum stirrer. To further enhance the input, the unit accommodates up to a maximum of six individual capillaries. The HVB features a measuring range of 5C to 200C and can be used with mineral oil, silicone oil, or water as the bath base media. Bath temperature is displayed on a bright, easy-to-read digital display. In addition, the unit features a built-in over-temperature circuit protection.
Features:
Accommodates up to six capillary tubes; optional Cannon-Fenske or Canon- Menin tube holders available Measures kinematic viscosity of petroleum products/any oils at temperatures from 20C to 150C, according to ASTM D 445; IP 71 ; DIN 51562 ; ISO 3104 ; IS-1206 Controls bath temperature with 0.01C stability & resolution of o.1C Digital bath temperature measurement and display Large capacity bath with built-in stirrer cum PUMP, & illumination by Daylight CFL fluorescent tube Integral over-temperature protection through SSR. SS Ball Valve provided for ease of Drain.
The unit has a double walled construction with outer GI /MS powder coat finish & argon welded inner of SS 304, having glass wool insulation between the walls. A motorized Pump with Stirrer is provided for better temperature uniformity. Toughened glass window from both sides with fluorescent tube for easy visualization. The SS immersion heater (Hot + COLD Zone Type) does the heating. PID Auto tuned Microprocessor based Digital temperature controller cum indicator controls the process temperature. Cooling of bath is achieved by CFC free hermetically sealed Compressor & direct copper tubing inside the inner area for fast & accurate cooling.

View Complete Details

Oscillating Disc Rheometer

Applications

The Rheometer describes precisely and quickly curing and processing characteristics of vulcanizable rubber compounds. Computer Controlled Automated Testing, Repeatability-Continuous repeated testing, Window environment easy to operate, huge Capacity of data storage and retrieval, Color Printouts, Multiple color coded graphs for easy separation of batches, Flexible testing timings, Statically Computation of data, Fast Temperature recovery, Automatic Computation of results at the end of test sequence. Sample Volume Approx. 8 CM^3, Oscillating Disc Frequency 100Cycles/Min (1.66Hz), Oscillating Amplitude +/- 1 Deg, 3 Deg, 5 Deg, and Microprocessor Temp. Controller Calibrated range 100200 Deg C. Directly shaft mounted inline with oscillating disk. Directly online display on monitor, Air Pressure 60 PST, 4.2Kg/Cm2

View Complete Details

Mooney Viscometer

  • Mooney Measuring range 0 to 200MU,
  • Pre Heat Time 0-60Sec,
  • Rotor size large and small,
  • Rotor speed 2.0 +/- 0.2 rpm,
  • Synchronous geared motor,
  • Temperature PT 100 Platinum resistors Microprocessor controlled.
  • Calibrated rage 5 Deg to 200 Deg,
  • Independent upper and lower platen control,
  • Temp. Control Accuracy +/-0.5 C PID Temp Control,
  • Torque transducer reaction torque sensor,
  • Computer Controlled testing,
  • Directly on line display on VGA monitor.
  • Req. Air Pressure 60PSI Minimum operating pressure controlled by external regulator with gauge.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Viscosity Instruments from Pune, Maharashtra by Gatha Enterprises
Post Buy Requirement
GE

Gatha Enterprises Pune, Maharashtra

Pune, Maharashtra, India
Add Review

Our Products

  1. Testing Equipment 11 Products available
  2. Laboratory Apparatus 5 Products available
  3. Industrial Machinery 4 Products available
  4. Viscosity Instruments 4 Products available
  5. Measurement Gauges & Fittings

    2 Products available
  6. Industrial Ovens & Furnaces

    2 Products available
  7. Microscope

    1 Products available
  8. Security, Metal & Leak Detectors

    1 Products available
  9. Cutting Machines & Equipment

    1 Products available
  10. Polishing Machines

    1 Products available
  11. Others Products 7 Products available

Viscosity Instruments #5814019

Our offered Product range includes Moving Die Rheometer, Kinematic Viscosity Bath, Oscillating Disc Rheometer and Mooney Viscometer.

Moving Die Rheometer

Elastic Modules, Tan Delta, Initial, Maximum Torque, Rotor less, Viscous Modus, Cure rate, Minimum torque, Scorch points, Smaller Sample size. Viscous and Elastic S Modulus (torques) can be separated, Choice of display S or tan and along with elastic Modulus, Automated Testing, Online Display of Torque vs. Time graph, Graphical Comparison of results. Other Features are as above. Sample Volume Approx. 6 CM^3, Oscillating Disc Frequency 100Cycles/Min (1.66Hz), Oscillating Amplitude +/- 0.5 Deg, 1 Deg, 3 Deg, and Microprocessor Temp. Controller Calibrated range 100200 Deg C., Air Pressure 60 PST, 4.2Kg/Cm2.

View Complete Details

Kinematic Viscosity Bath

The Viscosity Bath is designed to simplify ASTM D 445; IS-1206 kinematic viscosity testing. A top-mounted controller keypad permits quick entry of bath set point temperature while a sophisticated microprocessor PID Auto tuned controller controls the bath heating and stirring through flange top mounted motorized pump cum stirrer. To further enhance the input, the unit accommodates up to a maximum of six individual capillaries. The HVB features a measuring range of 5C to 200C and can be used with mineral oil, silicone oil, or water as the bath base media. Bath temperature is displayed on a bright, easy-to-read digital display. In addition, the unit features a built-in over-temperature circuit protection.
Features:
Accommodates up to six capillary tubes; optional Cannon-Fenske or Canon- Menin tube holders available Measures kinematic viscosity of petroleum products/any oils at temperatures from 20C to 150C, according to ASTM D 445; IP 71 ; DIN 51562 ; ISO 3104 ; IS-1206 Controls bath temperature with 0.01C stability & resolution of o.1C Digital bath temperature measurement and display Large capacity bath with built-in stirrer cum PUMP, & illumination by Daylight CFL fluorescent tube Integral over-temperature protection through SSR. SS Ball Valve provided for ease of Drain.
The unit has a double walled construction with outer GI /MS powder coat finish & argon welded inner of SS 304, having glass wool insulation between the walls. A motorized Pump with Stirrer is provided for better temperature uniformity. Toughened glass window from both sides with fluorescent tube for easy visualization. The SS immersion heater (Hot + COLD Zone Type) does the heating. PID Auto tuned Microprocessor based Digital temperature controller cum indicator controls the process temperature. Cooling of bath is achieved by CFC free hermetically sealed Compressor & direct copper tubing inside the inner area for fast & accurate cooling.

View Complete Details

Oscillating Disc Rheometer

Applications

The Rheometer describes precisely and quickly curing and processing characteristics of vulcanizable rubber compounds. Computer Controlled Automated Testing, Repeatability-Continuous repeated testing, Window environment easy to operate, huge Capacity of data storage and retrieval, Color Printouts, Multiple color coded graphs for easy separation of batches, Flexible testing timings, Statically Computation of data, Fast Temperature recovery, Automatic Computation of results at the end of test sequence. Sample Volume Approx. 8 CM^3, Oscillating Disc Frequency 100Cycles/Min (1.66Hz), Oscillating Amplitude +/- 1 Deg, 3 Deg, 5 Deg, and Microprocessor Temp. Controller Calibrated range 100200 Deg C. Directly shaft mounted inline with oscillating disk. Directly online display on monitor, Air Pressure 60 PST, 4.2Kg/Cm2

View Complete Details

Mooney Viscometer

  • Mooney Measuring range 0 to 200MU,
  • Pre Heat Time 0-60Sec,
  • Rotor size large and small,
  • Rotor speed 2.0 +/- 0.2 rpm,
  • Synchronous geared motor,
  • Temperature PT 100 Platinum resistors Microprocessor controlled.
  • Calibrated rage 5 Deg to 200 Deg,
  • Independent upper and lower platen control,
  • Temp. Control Accuracy +/-0.5 C PID Temp Control,
  • Torque transducer reaction torque sensor,
  • Computer Controlled testing,
  • Directly on line display on VGA monitor.
  • Req. Air Pressure 60PSI Minimum operating pressure controlled by external regulator with gauge.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us