Acrylic Body Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 10 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

Acrylic block construction with direct reading scales have white screen printed backs to enhance scale readability. Connections are in-line for easy installation with flanged or screwed connections with several options of materials for the wetted parts. Available in the sizes from 1/2" to 4". Available in various Scale lengths 175-200 mm, 250 mm, 500 mm to suit customer requirements.

Application Fluid Media : Air Gases/Water, Liquid
Measuring Ranges : Between 2.5 to 40, 000 LPH / 0.018 to 175.5 USGPM of Water at Ambient Temp. Between 0.1 to 300 NM3 / HR / 0.9 to 190 SCFM of Air at Ambient Temperature 760 Torre.

Line size : 1/2" to 4"
Thread standard : Bsp/Npt/Swagelok/push ftting/Nozzle
Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304/PP/UPVC
FLOAT MOC : SS316/ SS 304/TEFLON
WETTED PART MOC : SS316 /SS 304/MS/TEFLON LINING WITH MS, CS
BODY MOC : /(PMMA) Poly(methyl methacrylate),Transparent Thermoplastic Acrylic Clear with shining Buff. METERING TUBE MOC TRANSPARENT ACRYLIC TUBE DRILLED & MACHINED WITHTAPERED REAMER CUTTER INSIDE THE BODY.
PACKING ELASTOMER : SILICON, VITON, EPDM, NEOPRINE
FLANGE TO FLANGE DISTANCE : 400 MM
SCALE : ENGRAWING ON ACRYLIC BODY IT SELF WITH BLACK MARKING LETTERS ON METERING TUBE
MOUNTING/INLET & OUTLET : VERTICAL BOTTOM TO TOP
View Complete Details

Acrylic Rotameter

  • Max PRESSURE 8 KG/CM2
  • Accuracy ± 2% F.S.Overall, Calibrated at STP
Economical machined cast acrylic block construction makes these flowmeters great for OEM use. Optional inlet metering Needle valve available.Economical machined cast acrylic block construction makes these flowmeters great for OEM use. Optional inlet metering Needle valve available.
View Complete Details

Glass Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 7 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

GLASS TUBE ROTAMETER is Basically Variable Area Flowmeter the differential Pressure across the annulus area in constant and the flow rate is measured as a function of the annulus area.This areais displayed as the position of a float. Suitable for in line installation with flanged or screwed connections with several options of materials for the wetted parts. Available in the sizes from 1/2" to 4". Available in various Scale lengths 175-200 mm, 250 mm, 500 mm to suit customer requirements

Line size : 1/2" to 4"
Thread standard : Bsp/Npt/Swagelok/push ftting/Nozzle
Flange Standard : ASA 150 RF /BS 10 Table D,E,F,/DN,PN
Flange Moc : SS316/SS 304/PP/UPVC
Float Moc : SS316/ SS 304/TEFLON
Wetted Part Moc : SS316/SS 304/MS/Teflon Lining with MS, CS
Bodycasing Side Plates Moc : SS 304 with Shining Buffed/MS Epoxy Coated/Aluminium with Two Tone Powder Coated Excellent Finish
Metering Tube Moc : Wall Tempered Borosil Taperd Glass of 4.8 MM Wall Thickness Ribbed Type FPG
Gland Packing : Silicon, Viton, EPDM, Over wrapping Teflon Cover Cap
Flange to Flange distance : 450 MM
Scale : Milky White Acrylic with Black Screen Printing Letters / Aluminium Anodized / ss Engrawing / Ceramic Ink Etched on Metering Tube
Mounting/Inlet & Outlet : Vertical Bottom to Top
View Complete Details

Metal Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 18 KG/CM2
  • ACCURACY. ± 4% F.S.Overall, Calibrated at STP

Metal Tube Rotameter is basically a variable area flowmeter. These 316L stainless steel meters feature flange connections, all welded construction (no O-rings), and an end to end length of 350mm. A float sensed by a magnet and indicated on the dial in terms of flowrate and tapered tube design provides longer, more linear scales. A 4-20mA transmitter option adds to its versatility.

Suitable for Flow Measurement of Translucent/Opaque Fluids with high operating Pressure and Temperature. Available in the sizes from 1/2" to 4". Available in various Total lengths 250 mm, 300 mm, 350 mm, 400 mm, to suit customer requirements

A 4-20mA Transmitter uses a unique magnetic sensor which is directly placed on the PCB. As the float moves in the taper tube the magnetic flux around the sensor changes in accordance with the float position. This change in magnetic flux causes the change in the output of the sensor. This output is amplified and linearised using microprocessor based circuitry to get standard loop powered 4-20 mA DC output.

Ranges Between : 16 to 60000 LPH / 0.07 to 266 USGPM Water at Ambient emperature. Between 0.45 to 1450 NM3 / HR / 0.28 to 915 SCFM Air at Ambient Temperature, 760 Torr
Application Fluid Media : Air Gases/Water, Liquid, Acid
Measuring Ranges : Between 2.5 to 40, 000 LPH / 0.018 to 175.5 USGPM of Water at Ambient Temp. Between 0.1 to 300 NM3 / HR / 0.9 to 190 SCFM of Air at Ambient Temperature 760 Torre.

Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304
FLOAT MOC : SS316/ SS 304
SCALE INDICATION : [90 DEG. POINTER TYPE]
FRONT FASCIA MOC : TOUGHENED GLASS WITH SS 304 HOUSING
POINTER : ALUMINIUM WITH BLACK EPOXY COATED
WETTED PART MOC : SS316L /SS 304
PACKING : SS 304 ARGON WELD
BODY CASING MOC : SS 304 WITH SHINING BUFFED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH
INDICATOR BOX (HOUSING) : SS 304 WEATHER PROOF IP-65 TOTALLY PROTECTION AGAINST DUST & WATER SPRAYED FROM ALL DIRECTIONS
METERING TAPRE TUBE MOC : SS316/SS304L
FLANGE TO FLANGE DISTANCE : 250 mm, 300 mm, 350 mm, 400 mm
SCALE : MILKY WHITE ACRYLIC / ALUMINIUM ANODIZING WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
MOUNTING/INLET & OUTLET : VERTICAL BOTTOM TO TOP
ACCESSORIES : ELECTRONIC TRANSMITTER WITH 4-20 MA OUTPUT, HART (OPTIONAL), DIGITAL FLOW RATE INDICATOR / TOTALISER, MINIMUM OR MAXIMUM FLOW SWITCH.
View Complete Details

Purge Rotameter

  • Ambient Temperature 5-60 Deg.c
  • Ambient Pressure 0.985 to 1.05 Atm.
  • ACCURACY ± 2% F.S.Overall, Calibrated at STP
Suitable for purging or low flowrate measurement. The standard mounting is 14" BSP NPT rear , although several arrangement of Flanged or Hose pipe connection are offered on requests. Special sterilizable Lowflowmeter for Auto-clave applications is also available against specific enquries.
View Complete Details

Low Flow Purge Glass Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 8 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

Suitable for purging or low flowrate measurement. The standard mounting is 1/4" BSP / NPT rear , although several arrangement of Flanged or Hose pipe connection are offered on requests. Special sterilizable Lowflowmeter for Auto-clave applications is also available against specific enquries

Application Fluids : Air Gases/Water, Liquid, Acid
Measuring Ranges : Between 0.6 to 160 LPH / 50-500 ML/MIN of Water at Ambient Temperature. Between 1 to 5000 NLPH / 0.001 to 3.1 SCFM of Air at Ambient Temperature, 760 Torre.

Line size : 1/4",BSP / NPT Rear WITH FINE CONTROL NEEDLE VALVE &HEX LOCK NUT
Thread Standard : Bsp/Npt/Metric /Swagelok/push ftting/Nozzle.
Float Moc : Spherical Glass ball/ Conical SS 316/ SS 304/TEFLON /Red pvc
NEEDLE VALVE MOC : SS304/ SS 316
End Fitting MOC : SS316 /SS 304
BODYCASING SIDE PLATES MOC : SS 304 WITH SHINING BUFFED/MS EPOXY COATED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH
METERING TUBE MOC : HEAVY WALL TEMPERED BOROSIL TAPERD GLASS OF 4MM WALL THICKNESS FPG
GLAND PACKING : SILICON ,VITON,EPDM,OVERWRAPPING TEFLON COVER CAP
SCALE : MILKY WHITE ACRYLIC WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
Mounting : Panel Mounting Clamps.,High & Low Flow Alarms.
OVER ALL LENGTH : 200 MM
CENTRE TO CENTRE DISTANCE : 150 MM
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • FLOW POINT INDIA (FLOW POINT INDIA)
  • A/104, Divya Stuti C.H.S, B/h.Maharaja Bldg, Kanyapada Filmcity Road, Gokuldham, Goregoan (E), Mumbai, Maharashtra-400 102 (INDIA) - 400102
  • Share us via
  • Call 08069182200 Ext. 500
Manufacturer of Rotameters from Mumbai, Maharashtra by FLOW POINT INDIA
Post Buy Requirement

Rotameters

Our product range contains a wide range of Acrylic Body Rotameter, Acrylic Rotameter, Glass Tube Rotameter, Metal Tube Rotameter and Purge Rotameter

Acrylic Body Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 10 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

Acrylic block construction with direct reading scales have white screen printed backs to enhance scale readability. Connections are in-line for easy installation with flanged or screwed connections with several options of materials for the wetted parts. Available in the sizes from 1/2" to 4". Available in various Scale lengths 175-200 mm, 250 mm, 500 mm to suit customer requirements.

Application Fluid Media : Air Gases/Water, Liquid
Measuring Ranges : Between 2.5 to 40, 000 LPH / 0.018 to 175.5 USGPM of Water at Ambient Temp. Between 0.1 to 300 NM3 / HR / 0.9 to 190 SCFM of Air at Ambient Temperature 760 Torre.

Line size : 1/2" to 4"
Thread standard : Bsp/Npt/Swagelok/push ftting/Nozzle
Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304/PP/UPVC
FLOAT MOC : SS316/ SS 304/TEFLON
WETTED PART MOC : SS316 /SS 304/MS/TEFLON LINING WITH MS, CS
BODY MOC : /(PMMA) Poly(methyl methacrylate),Transparent Thermoplastic Acrylic Clear with shining Buff. METERING TUBE MOC TRANSPARENT ACRYLIC TUBE DRILLED & MACHINED WITHTAPERED REAMER CUTTER INSIDE THE BODY.
PACKING ELASTOMER : SILICON, VITON, EPDM, NEOPRINE
FLANGE TO FLANGE DISTANCE : 400 MM
SCALE : ENGRAWING ON ACRYLIC BODY IT SELF WITH BLACK MARKING LETTERS ON METERING TUBE
MOUNTING/INLET & OUTLET : VERTICAL BOTTOM TO TOP
View Complete Details

Acrylic Rotameter

  • Max PRESSURE 8 KG/CM2
  • Accuracy ± 2% F.S.Overall, Calibrated at STP
Economical machined cast acrylic block construction makes these flowmeters great for OEM use. Optional inlet metering Needle valve available.Economical machined cast acrylic block construction makes these flowmeters great for OEM use. Optional inlet metering Needle valve available.
View Complete Details

Glass Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 7 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

GLASS TUBE ROTAMETER is Basically Variable Area Flowmeter the differential Pressure across the annulus area in constant and the flow rate is measured as a function of the annulus area.This areais displayed as the position of a float. Suitable for in line installation with flanged or screwed connections with several options of materials for the wetted parts. Available in the sizes from 1/2" to 4". Available in various Scale lengths 175-200 mm, 250 mm, 500 mm to suit customer requirements

Line size : 1/2" to 4"
Thread standard : Bsp/Npt/Swagelok/push ftting/Nozzle
Flange Standard : ASA 150 RF /BS 10 Table D,E,F,/DN,PN
Flange Moc : SS316/SS 304/PP/UPVC
Float Moc : SS316/ SS 304/TEFLON
Wetted Part Moc : SS316/SS 304/MS/Teflon Lining with MS, CS
Bodycasing Side Plates Moc : SS 304 with Shining Buffed/MS Epoxy Coated/Aluminium with Two Tone Powder Coated Excellent Finish
Metering Tube Moc : Wall Tempered Borosil Taperd Glass of 4.8 MM Wall Thickness Ribbed Type FPG
Gland Packing : Silicon, Viton, EPDM, Over wrapping Teflon Cover Cap
Flange to Flange distance : 450 MM
Scale : Milky White Acrylic with Black Screen Printing Letters / Aluminium Anodized / ss Engrawing / Ceramic Ink Etched on Metering Tube
Mounting/Inlet & Outlet : Vertical Bottom to Top
View Complete Details

Metal Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 18 KG/CM2
  • ACCURACY. ± 4% F.S.Overall, Calibrated at STP

Metal Tube Rotameter is basically a variable area flowmeter. These 316L stainless steel meters feature flange connections, all welded construction (no O-rings), and an end to end length of 350mm. A float sensed by a magnet and indicated on the dial in terms of flowrate and tapered tube design provides longer, more linear scales. A 4-20mA transmitter option adds to its versatility.

Suitable for Flow Measurement of Translucent/Opaque Fluids with high operating Pressure and Temperature. Available in the sizes from 1/2" to 4". Available in various Total lengths 250 mm, 300 mm, 350 mm, 400 mm, to suit customer requirements

A 4-20mA Transmitter uses a unique magnetic sensor which is directly placed on the PCB. As the float moves in the taper tube the magnetic flux around the sensor changes in accordance with the float position. This change in magnetic flux causes the change in the output of the sensor. This output is amplified and linearised using microprocessor based circuitry to get standard loop powered 4-20 mA DC output.

Ranges Between : 16 to 60000 LPH / 0.07 to 266 USGPM Water at Ambient emperature. Between 0.45 to 1450 NM3 / HR / 0.28 to 915 SCFM Air at Ambient Temperature, 760 Torr
Application Fluid Media : Air Gases/Water, Liquid, Acid
Measuring Ranges : Between 2.5 to 40, 000 LPH / 0.018 to 175.5 USGPM of Water at Ambient Temp. Between 0.1 to 300 NM3 / HR / 0.9 to 190 SCFM of Air at Ambient Temperature 760 Torre.

Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304
FLOAT MOC : SS316/ SS 304
SCALE INDICATION : [90 DEG. POINTER TYPE]
FRONT FASCIA MOC : TOUGHENED GLASS WITH SS 304 HOUSING
POINTER : ALUMINIUM WITH BLACK EPOXY COATED
WETTED PART MOC : SS316L /SS 304
PACKING : SS 304 ARGON WELD
BODY CASING MOC : SS 304 WITH SHINING BUFFED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH
INDICATOR BOX (HOUSING) : SS 304 WEATHER PROOF IP-65 TOTALLY PROTECTION AGAINST DUST & WATER SPRAYED FROM ALL DIRECTIONS
METERING TAPRE TUBE MOC : SS316/SS304L
FLANGE TO FLANGE DISTANCE : 250 mm, 300 mm, 350 mm, 400 mm
SCALE : MILKY WHITE ACRYLIC / ALUMINIUM ANODIZING WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
MOUNTING/INLET & OUTLET : VERTICAL BOTTOM TO TOP
ACCESSORIES : ELECTRONIC TRANSMITTER WITH 4-20 MA OUTPUT, HART (OPTIONAL), DIGITAL FLOW RATE INDICATOR / TOTALISER, MINIMUM OR MAXIMUM FLOW SWITCH.
View Complete Details

Purge Rotameter

  • Ambient Temperature 5-60 Deg.c
  • Ambient Pressure 0.985 to 1.05 Atm.
  • ACCURACY ± 2% F.S.Overall, Calibrated at STP
Suitable for purging or low flowrate measurement. The standard mounting is 14" BSP NPT rear , although several arrangement of Flanged or Hose pipe connection are offered on requests. Special sterilizable Lowflowmeter for Auto-clave applications is also available against specific enquries.
View Complete Details

Low Flow Purge Glass Tube Rotameter

  • Repeatability 10 1
  • Operating Principle Variable Area Type
  • Max PRESSURE 8 KG/CM2
  • ACCURACY. ± 2% F.S.Overall, Calibrated at STP

Suitable for purging or low flowrate measurement. The standard mounting is 1/4" BSP / NPT rear , although several arrangement of Flanged or Hose pipe connection are offered on requests. Special sterilizable Lowflowmeter for Auto-clave applications is also available against specific enquries

Application Fluids : Air Gases/Water, Liquid, Acid
Measuring Ranges : Between 0.6 to 160 LPH / 50-500 ML/MIN of Water at Ambient Temperature. Between 1 to 5000 NLPH / 0.001 to 3.1 SCFM of Air at Ambient Temperature, 760 Torre.

Line size : 1/4",BSP / NPT Rear WITH FINE CONTROL NEEDLE VALVE &HEX LOCK NUT
Thread Standard : Bsp/Npt/Metric /Swagelok/push ftting/Nozzle.
Float Moc : Spherical Glass ball/ Conical SS 316/ SS 304/TEFLON /Red pvc
NEEDLE VALVE MOC : SS304/ SS 316
End Fitting MOC : SS316 /SS 304
BODYCASING SIDE PLATES MOC : SS 304 WITH SHINING BUFFED/MS EPOXY COATED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH
METERING TUBE MOC : HEAVY WALL TEMPERED BOROSIL TAPERD GLASS OF 4MM WALL THICKNESS FPG
GLAND PACKING : SILICON ,VITON,EPDM,OVERWRAPPING TEFLON COVER CAP
SCALE : MILKY WHITE ACRYLIC WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
Mounting : Panel Mounting Clamps.,High & Low Flow Alarms.
OVER ALL LENGTH : 200 MM
CENTRE TO CENTRE DISTANCE : 150 MM
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • FLOW POINT INDIA (FLOW POINT INDIA)
  • A/104, Divya Stuti C.H.S, B/h.Maharaja Bldg, Kanyapada Filmcity Road, Gokuldham, Goregoan (E), Mumbai, Maharashtra-400 102 (INDIA) - 400102
  • Share us via
  • Call 08069182200 Ext. 500