Post Buy Requirement
FP
Mumbai, Maharashtra, India
Verified Add Review

Other Products / Services #5410128

BYE PASS ROTAMETER

Suitable for measuring Rotameters in 50 NB & above pipeline sizes. Available upto 450 NB line size in a variety of materials. Complete assembly consists of Orifice Plate, Carrier Rings, Impulse Tubing, Isolation Valves and Rotameter. Byepass Rotameters with D & D2 tappings are available against specific enquiries.

Application Fluid Media : Air Gases/Water, Liquid, Acid
Ranges : Between 20 to 800 M3/HR of Water. Higher Flow and higher line sizes on request

Line size : 1/2" to 4"
Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304/PP/UPVC
FLOAT MOC : Conical SS 316/ SS 304
WETTED PART : SS 316/SS 304L/MS POWDER COATED
ROTAMETER LINE : PIPE LINE ½" OD SS 304
VALVE : 1/4" BALL VALVE SS 304
ORIFICE PLATE : 4 MM THICKNESS SS 316
BODYCASING SIDE PLATES MOC : SS 304 WITH SHINING BUFFED/MS EPOXY COATED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH/(PMMA) Poly(methyl methacrylate), Transparent Thermoplastic Acrylic Clear
METERING TUBE MOC : HEAVY WALL TEMPERED BOROSIL TAPERD GLASS OF 4.8 MM WALL THICKNESS FPG. TRANSPARENT ACRYLIC TUBE DRILLED & MACHINED WITHTAPERED REAMER CUTTER INSIDE THE BODY.
GLAND PACKING : SILICON, VITON, EPDM, OVERWRAPPING TEFLON COVER CAP
FITTING TO FITTING DISTANCE : 350 MM
SCALE : MILKY WHITE ACRYLIC WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
MOUNTING. : VERTICAL /HORIZONTAL.
View Complete Details

Reflex Level Gauges

These gauges are used for measuring the level in a vessel.These can be used for maximum pressure of upto150kg/cm2 and a maximum temperature of 4000 C. Constructional features include upto 2.5 metre single piece construction with multiple glasses between process connections. A pair of auto shut off ball check valves in standard material of construction; Carbon Steel or Stainless Steel; Polypropylene as optional.

WORKING PRINCIPLE

The principle of Reflex Level Gauges is based on the difference in the refractive indices of liquid and vapour. The liquid column is contained within the recess of the liquid chamber behind the sight glass which is clamped to the gauge body. The sight glass has prismatic right angled grooves on the side facing the liquid and vapor space. Light rays entering from outside the gauge are either absorbed or reflected depending upon whether they enter the liquid or vapour space. When the ray of light encounters the surface of one of the grooves in the vapor space, it is reflected to the opposite surface of the grooves and from there, totally reflected back to the direction of observation. Thus vapour space appears as silvery white. When the light ray encounters the surface of the grooves in the liquid space, it is totally absorbed thereby the liquid behind the glass appear black.

C/C Distance : to100"; single piece liquid chamber.
Gauge classification X : Low pressure X 30Kg/cm², Medium pressure X 85Kg/cm² Test pressure High pressure X 165Kg/cm², Very high pressure X 210Kg/cm²
Gauge glass : Tempered soda ash/ Borosilicate (30W x 17mm Thk) / Tempered borosilicate (34W x 17mm Thk)
Cushion/Gasket : CAF, CNAF, PTFE, SS304 Spiral wound with Graphite Filler & SS316 Spiral wound with Graphite Filler
Body (liquid chamber) : CS, ASTM A -105, SS304, SS316 or PP (CS Reinforced)
Cover plate : CS, ASTM A -105, SS304, SS316 or FRP
Chamber connection : ½" NPT (F)
Bolts : CS or SS304 or A 193 Gr. B7
Nuts : CS or SS304 or A 194 Gr. B4
Gauge connection : up (side-side chamber conn) or Straight thru`(top-bottom chamber conn)
Process (vessel) conn. : Flanged 20 or 25 NB to various standards & pressure ratings Screwed ¾" male shank,union & spherical union
Process conn orientation : Rear/Rear or Left/Left or Right/Right or Vertical/ Vertical
Isolating valves : Offset needle valve x auto ball check x Screwed bonnet (85 Kg/cm²) / Union bonnet (165Kg/cm²) / Bolted bonnet (210Kg/cm²)
Vent : ½" NPT (BSP for PP/TEFLON MOC) plug / valve (Ball, Needle, Diaphragm, Globe, Gate as reqd.)
Drain : ½" NPT(BSP for PP/TEFLON MOC) plug/valve (Ball, Needle, Diaphragm, Globe, Gate as reqd.)
View Complete Details

Capsule Follower Magnetic Level Indicator

It is commonly used for visual level indication of liquids, which attack glass or are hazardous, flammable, toxic, aggressive, agitated, contaminated and under high temperature & Pressure i.e. for services where glass gauges are unsafe.

Features :Rugged gland less construction to provide safety in handling toxic, flammable & highly corrosive Liquid. Suitable for glass attacking liquid, where conventional gauge glass can not be used

Construction & Operation :It consists of a chamber and an internal float in non-magnetic material compatible with the liquid. The float containing a magnetic system rides on liquid level and is coupled to an external visual indicator, which comes in two options. The simnpler & economical design consists of a RED magnetic follower Capsule, that moves within a glass tube Filled with water (to reduce friction) and can be read against a scale. The Other system is expensive and consists of a series of Bi-colour flappers. White on front side and contrasting RED on the reverse. These flappers rotate corresponding to float movement, thus changing their colour from white to red as the float rises and vice-versa when the float falls. As such the liquid represented by an external RED coloumn.

Operating Principle :These models consist of Bi-coloured magnetic rollers equipped with small rod magnets which are rotated one after another at an angle of 180o by the directed field of the Permanent magnet inside the float.In addition, Level sensing elements can be fixed directly to the float cage, so that simultaneously liquid level is electrically measured through smart transmitter with output of 4-20mA. It is possible to connect Level indicating Meters and Set Point Relays at any distance for control and display purpose. The Magnetic Level transmitters can also be supplied with HART PROTOCOL.Moreover it is possible to attach bistable Magnetic Switches to the Magnetic Level indicator in order to get switching at any desired liquid level.

Installation : Side / Top
Range (C=C DIST) : Max. 3000mm (Magnetic follower capsule)
Max. 5000mm (Bicolour rotating flappers)
Level Indication : a) Red PP Follower Capsule -150°C in Toughened glass tube (H2O filled)
b) Bicolour Rotating PP Flappers - 150°C (White & Red)
c) Bicolour Rotating Ceramic Flappers - 400°C (White & Red) Fitted externally to the float chamber
Float Chamber : Ø 60.3 mm in SS304/SS316/PP/PVDF
Float : Ø 50 mm in SS316/PP/PVDF (for Side mounted) & Ø 75 mm in SS316/ PP (for Top mounted)
Still Well : CS/SS304/SS316/PP (80NB)
Calibrated Scale : White powder coated Aluminium /SS (LC-10mm)
Shut off Valve : 20 NB Ball/Globe Valves (SS)
(Isolation for Gauge) : 25NB flanged Ball Valve (PP)
Vent x Drain : ½" Threaded Plugs/Valves
Process Connection : 1) 25NB/40NB/50NB Flanges for Side Mtd to BS/ANSI/DIN or 100NB Flange for Top Mtd. to BS/ANSI/DIN
2) ½"/ ¾"/ 1" BSP or NPT (M/F) Screwed
3) ½"/ ¾"/ 1" BSP or NPT (M/F) Union
Max Temp : 70°C ( PP ) /100°C (PVDF)/400°C (SS)
Max Test Pressure : 2 Kg/cm² ( PP/PVDF)/10 Kg/cm² (SS) or
(at amb. temp) : 100Kg/cm² (SS)
Min. Liquid Sp. Gr. : 0.7 - Side Mtd., 0.8 - Top Mtd.





View Complete Details

Top Mounted Level Switch

Top Mounted Level Switch

Flow Point Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem ), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • FLOW POINT INDIA (FLOW POINT INDIA)
  • A/104, Divya Stuti C.H.S, B/h.Maharaja Bldg, Kanyapada Filmcity Road, Gokuldham, Goregoan (E), Mumbai, Maharashtra-400 102 (INDIA) - 400102
  • Share us via
  • Call 08069182200 Ext. 500
List of Other Products by FLOW POINT INDIA from Mumbai, Maharashtra.
Post Buy Requirement
FP
Mumbai, Maharashtra, India
Verified Add Review

Other Products / Services #5410128

BYE PASS ROTAMETER

Suitable for measuring Rotameters in 50 NB & above pipeline sizes. Available upto 450 NB line size in a variety of materials. Complete assembly consists of Orifice Plate, Carrier Rings, Impulse Tubing, Isolation Valves and Rotameter. Byepass Rotameters with D & D2 tappings are available against specific enquiries.

Application Fluid Media : Air Gases/Water, Liquid, Acid
Ranges : Between 20 to 800 M3/HR of Water. Higher Flow and higher line sizes on request

Line size : 1/2" to 4"
Flange Standard : ASA 150 RF /BS 10 TABLE D, E, F, /DN, PN
FLANGE MOC : SS316/SS 304/PP/UPVC
FLOAT MOC : Conical SS 316/ SS 304
WETTED PART : SS 316/SS 304L/MS POWDER COATED
ROTAMETER LINE : PIPE LINE ½" OD SS 304
VALVE : 1/4" BALL VALVE SS 304
ORIFICE PLATE : 4 MM THICKNESS SS 316
BODYCASING SIDE PLATES MOC : SS 304 WITH SHINING BUFFED/MS EPOXY COATED/ALUMINIUM WITH TWO TONE POWDER COATED EXCELLENT FINISH/(PMMA) Poly(methyl methacrylate), Transparent Thermoplastic Acrylic Clear
METERING TUBE MOC : HEAVY WALL TEMPERED BOROSIL TAPERD GLASS OF 4.8 MM WALL THICKNESS FPG. TRANSPARENT ACRYLIC TUBE DRILLED & MACHINED WITHTAPERED REAMER CUTTER INSIDE THE BODY.
GLAND PACKING : SILICON, VITON, EPDM, OVERWRAPPING TEFLON COVER CAP
FITTING TO FITTING DISTANCE : 350 MM
SCALE : MILKY WHITE ACRYLIC WITH BLACK SCREEN PRINTING LETTERS/ALUMINIUM ANODIZED/SS ENGRAWING/ CERAMIC INK ETCHED ON METERING TUBE
MOUNTING. : VERTICAL /HORIZONTAL.
View Complete Details

Reflex Level Gauges

These gauges are used for measuring the level in a vessel.These can be used for maximum pressure of upto150kg/cm2 and a maximum temperature of 4000 C. Constructional features include upto 2.5 metre single piece construction with multiple glasses between process connections. A pair of auto shut off ball check valves in standard material of construction; Carbon Steel or Stainless Steel; Polypropylene as optional.

WORKING PRINCIPLE

The principle of Reflex Level Gauges is based on the difference in the refractive indices of liquid and vapour. The liquid column is contained within the recess of the liquid chamber behind the sight glass which is clamped to the gauge body. The sight glass has prismatic right angled grooves on the side facing the liquid and vapor space. Light rays entering from outside the gauge are either absorbed or reflected depending upon whether they enter the liquid or vapour space. When the ray of light encounters the surface of one of the grooves in the vapor space, it is reflected to the opposite surface of the grooves and from there, totally reflected back to the direction of observation. Thus vapour space appears as silvery white. When the light ray encounters the surface of the grooves in the liquid space, it is totally absorbed thereby the liquid behind the glass appear black.

C/C Distance : to100"; single piece liquid chamber.
Gauge classification X : Low pressure X 30Kg/cm², Medium pressure X 85Kg/cm² Test pressure High pressure X 165Kg/cm², Very high pressure X 210Kg/cm²
Gauge glass : Tempered soda ash/ Borosilicate (30W x 17mm Thk) / Tempered borosilicate (34W x 17mm Thk)
Cushion/Gasket : CAF, CNAF, PTFE, SS304 Spiral wound with Graphite Filler & SS316 Spiral wound with Graphite Filler
Body (liquid chamber) : CS, ASTM A -105, SS304, SS316 or PP (CS Reinforced)
Cover plate : CS, ASTM A -105, SS304, SS316 or FRP
Chamber connection : ½" NPT (F)
Bolts : CS or SS304 or A 193 Gr. B7
Nuts : CS or SS304 or A 194 Gr. B4
Gauge connection : up (side-side chamber conn) or Straight thru`(top-bottom chamber conn)
Process (vessel) conn. : Flanged 20 or 25 NB to various standards & pressure ratings Screwed ¾" male shank,union & spherical union
Process conn orientation : Rear/Rear or Left/Left or Right/Right or Vertical/ Vertical
Isolating valves : Offset needle valve x auto ball check x Screwed bonnet (85 Kg/cm²) / Union bonnet (165Kg/cm²) / Bolted bonnet (210Kg/cm²)
Vent : ½" NPT (BSP for PP/TEFLON MOC) plug / valve (Ball, Needle, Diaphragm, Globe, Gate as reqd.)
Drain : ½" NPT(BSP for PP/TEFLON MOC) plug/valve (Ball, Needle, Diaphragm, Globe, Gate as reqd.)
View Complete Details

Capsule Follower Magnetic Level Indicator

It is commonly used for visual level indication of liquids, which attack glass or are hazardous, flammable, toxic, aggressive, agitated, contaminated and under high temperature & Pressure i.e. for services where glass gauges are unsafe.

Features :Rugged gland less construction to provide safety in handling toxic, flammable & highly corrosive Liquid. Suitable for glass attacking liquid, where conventional gauge glass can not be used

Construction & Operation :It consists of a chamber and an internal float in non-magnetic material compatible with the liquid. The float containing a magnetic system rides on liquid level and is coupled to an external visual indicator, which comes in two options. The simnpler & economical design consists of a RED magnetic follower Capsule, that moves within a glass tube Filled with water (to reduce friction) and can be read against a scale. The Other system is expensive and consists of a series of Bi-colour flappers. White on front side and contrasting RED on the reverse. These flappers rotate corresponding to float movement, thus changing their colour from white to red as the float rises and vice-versa when the float falls. As such the liquid represented by an external RED coloumn.

Operating Principle :These models consist of Bi-coloured magnetic rollers equipped with small rod magnets which are rotated one after another at an angle of 180o by the directed field of the Permanent magnet inside the float.In addition, Level sensing elements can be fixed directly to the float cage, so that simultaneously liquid level is electrically measured through smart transmitter with output of 4-20mA. It is possible to connect Level indicating Meters and Set Point Relays at any distance for control and display purpose. The Magnetic Level transmitters can also be supplied with HART PROTOCOL.Moreover it is possible to attach bistable Magnetic Switches to the Magnetic Level indicator in order to get switching at any desired liquid level.

Installation : Side / Top
Range (C=C DIST) : Max. 3000mm (Magnetic follower capsule)
Max. 5000mm (Bicolour rotating flappers)
Level Indication : a) Red PP Follower Capsule -150°C in Toughened glass tube (H2O filled)
b) Bicolour Rotating PP Flappers - 150°C (White & Red)
c) Bicolour Rotating Ceramic Flappers - 400°C (White & Red) Fitted externally to the float chamber
Float Chamber : Ø 60.3 mm in SS304/SS316/PP/PVDF
Float : Ø 50 mm in SS316/PP/PVDF (for Side mounted) & Ø 75 mm in SS316/ PP (for Top mounted)
Still Well : CS/SS304/SS316/PP (80NB)
Calibrated Scale : White powder coated Aluminium /SS (LC-10mm)
Shut off Valve : 20 NB Ball/Globe Valves (SS)
(Isolation for Gauge) : 25NB flanged Ball Valve (PP)
Vent x Drain : ½" Threaded Plugs/Valves
Process Connection : 1) 25NB/40NB/50NB Flanges for Side Mtd to BS/ANSI/DIN or 100NB Flange for Top Mtd. to BS/ANSI/DIN
2) ½"/ ¾"/ 1" BSP or NPT (M/F) Screwed
3) ½"/ ¾"/ 1" BSP or NPT (M/F) Union
Max Temp : 70°C ( PP ) /100°C (PVDF)/400°C (SS)
Max Test Pressure : 2 Kg/cm² ( PP/PVDF)/10 Kg/cm² (SS) or
(at amb. temp) : 100Kg/cm² (SS)
Min. Liquid Sp. Gr. : 0.7 - Side Mtd., 0.8 - Top Mtd.





View Complete Details

Top Mounted Level Switch

Top Mounted Level Switch

Flow Point Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem ), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • FLOW POINT INDIA (FLOW POINT INDIA)
  • A/104, Divya Stuti C.H.S, B/h.Maharaja Bldg, Kanyapada Filmcity Road, Gokuldham, Goregoan (E), Mumbai, Maharashtra-400 102 (INDIA) - 400102