Our Products
We offer a complete product range of BENCHTOP GRATING SPECTROPHOTOMETER, Portable Colorimeter, Paper Thickness Tester, Ultrasonic Flaw Detector and Analytical Weighing Balance
Item | GT-N19A | GT-N19B | GT-N19C | GT-N19D |
---|---|---|---|---|
Measuring Range | 0 - 6mm | |||
Accuracy | 0.01mm | 0.001mm | ||
Contact Pressure | 100±1kPa | |||
Contact Area | 200±5mm2 | |||
Dial | Pointer Dial indicator | Digital Dial indicator | Pointer Dial gauge | Digital Dial gauge |
Parallelism | ≤0.002mm | |||
Dimension | 375 x 264 x 400 | |||
Weight | About 6kg |
Ultrasonic testing for flaw detection of metal and composite parts, finally portable and truly user-friendly. Correct, complete, precise and reusable inspection data is key for ensuring the integrity of components and infrastructure. Proceq UT8000 represents a breakthrough in inspections with ultrasonic testing fordetecting flaws such as cracks and voids in metals and composites. For more information - 8291971983
Model | JA1003 | JA1203 | JA2003 | JA3003 | JA4003 | JA5003 | JA11003 |
---|---|---|---|---|---|---|---|
Weighing Range | 0-110g | 0-120g | 0-210g | 0-310g | 0-410g | 0-510g | 0-1100g |
Min. Reading | 0.001g | ||||||
Scale Interval | 1mg | ||||||
Repeatability Error | 0.001g | ||||||
Linear Error | ±0.002g | ||||||
Pan Size | Φ90mm | ||||||
Output Interface | Rs232C | ||||||
Size | 330*215*350mm & 5.5kg | ||||||
Power | 220V+22V/-33V、50Hz |
Model | FA1004N | FA1104N | FA1604N | FA2004N | FA2104N | FA2204N | FA3104N |
---|---|---|---|---|---|---|---|
Range | 0~100g | 0-110g | 0-160g | 0-200g | 0-210g | 0-220g | 310g |
Min. Reading | 0.0001g (0.1mg) | ||||||
Scale Interval | 0.1mg | ||||||
Repeat Error | 0.0002g | ||||||
Linear Error | ±0.0005g | ||||||
Pan Size | φ80mm | ||||||
Size | 330*215*350mm & 7.5kg | ||||||
Power | 100~240V, 50/60Hz |
Sizes of Walk-in Temeprature Chamber | ||||
Model | Volume | Internal Dimension D*W*H (mm) |
External Dimension D*W*H (mm) |
Power |
LRHS-28M-BRS | 28 m3 | 5000*2700*2100 | 5300*2900*3080 | 90 kW |
Specification | ||||
Performance | Temperature Range | from -40oC to +100oC | ||
Ramp Rate | 0.9oC/min (linear) for heating and cooling | |||
Temperature Fluctuation | ≤ ±0.5oC during -40oC~80oC ≤ ±1.0oC during 80oC~100oC |
|||
Structure | External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | ||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | |||
Heat Isolation | Polyurethane foams and fine glass fibres | |||
Illumination Lamp | Six, anti-temeprature | |||
Viewing Window | Toughened glass with conductive films for heating to defrost | |||
Door | Manually operated sliding door with unlock button | |||
Heating & Cooling | Heating System | Steipped Nickel-chromium Wire Heater | ||
Cooling System | Cascade refrigeration compressors. Water-cooled method. | |||
Control System | Controller | Programmable Touch-screen controller with data logging and download function | ||
Water Storage | Water tank for storing water for recycling use | |||
Safety Protection | Power leakage protection, over-load or over-current protection/Dry burning protection. | |||
Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement |
Sizes of Dust Test Chamber | ||||
Model | Volume (L) | Rated Power | Internal Dimension (mm) D*W*H | External Dimension (mm) D*W*H |
LRHS-512-PS | 512 | 2.5kw | 800*800*800 | 1300*1050*1750 |
LRHS-800-PS | 800 | 2.5kw | 800*1000*1000 | 1300*1250*1950 |
LRHS-1000-PS | 1000 | 2.5kw | 1000*1000*1000 | 1600*1250*1980 |
LRHS-1500-PS | 1500 | 2.5kw | 1000*1500*1000 | 1600*1750*1980 |
Basic Specification | ||||
Performance | Air speed | Not Exceed 2m/s Lowing | ||
Time setting Range | 1~999H adjustable | |||
Sand and dust concentration | 2~4kg/m3 | |||
Test Dust | Dry Talcum powder,Silicate cement,smoke ash,etc. | |||
Vacuum pump flow control | 60~600L/H | |||
Dust method | continous.period blowing dust time setting is optional | |||
Structure | External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | ||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | |||
Heat Isolation | Polyurethane foams and fine glass fibres | |||
Viewing Window | Toughened glass with conductive films for heating to defrost(395×395mm) | |||
Door | Manually operated sliding door with unlock button | |||
Control System | Controller | Programmable Touch-screen controller "weinview" with data logging and download function | ||
Heating System | Steipped Nickel-chromium Wire Heater | |||
Dust dehumidification | Heating and dehumidification | |||
Vibration time | 1S-99H adjustable | |||
Blowing time | 1S-99H adjustable | |||
Cycle time | Arbitrarily set the blowing time | |||
Dust heat | Use stainless steel Mica Heating coil constant control to prevent dust adhesion | |||
Standard Configuration | Test Chamber x 1,Dust scraperx 1, talcum powder x 100g , EMO x 1, Tri-color Indicator x 1, etc. | |||
Safety Protection | Power leakage protection, over-load or over-current protection/Fan motor overheating/Dry burning protection. | |||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | |||
Ambient Enviromental for application | 5oC~+30oC ≤ 85%R.H | |||
Test Standards (not limited to) | IEC 60529 IP5X IP6X |
Pulse Holiday Detector NOVOTEST SPARK-1 designed to detect pits, flaws, and holes in different non-metallic insulation coatings (such as polymers, epoxy, bitumen, etc.) and is mostly used for oil and gas metal pipelines and other objects.
Names / model | Schmidt Hammer NOVOTEST SH-225 | Schmidt Hammer NOVOTEST SH-75 | Schmidt Hammer NOVOTEST SH-20 |
Measurement range of strength, MPa | 10 – 60 | 10 – 60 | 1 – 25 |
Impact energy, J | 2207 | 735 | 196 |
Minimum thickness of testing object, mm | 70 and more | 50 – 100 | 30 and more |
Measurement accuracy, % | 10 | ||
Hardness value of impact plunger working surface, HRC, no less | 60 | ||
Surface roughness of testing object, Ra um, no worse | 40 | ||
Radius of impact plunger, mm | 25 | ||
Operating temperature range, oC | -20 … +50 | ||
Weight of the device, kg, no more | 1 | ||
Gross weight of package, kg | 1.7 |
Model | ME-H220 | ME-H550 | ME-H250 | ME-H150 | ME-H5100 | ME-H2100 | ME-H1100 |
---|---|---|---|---|---|---|---|
Moisture Range | 0-100% | ||||||
Maximum Weighing Capacity | 20g | 50g | 100g | ||||
Reading accuracy | 2mg | 5mg | 2mg | 1mg | 5mg | 2mg | 1mg |
Moisture Readability | 0.01% | 0.02% | 0.01% | 0.01% | 0.02% | 0.01% | 0.01% |
Moisture accuracy | 0.01% | ||||||
Moisture Reproducibility | 0.1% | 0.2% | 0.1% | 0.1% | 0.2% | 0.1% | 0.1% |
Heating Time range | 1-99min | ||||||
Temperature Control Accuracy | 1oC | ||||||
Display items | Before dry in weight, after-drying weight, the method of ending, the remaining time of heating(min), heating temperature, driage, drying rate, moisture weight rate, moisture regain rate | ||||||
Standard Accessory | Power cable, Sample plate, Sample Tray support, Correction weight, Tweezers |
Parameter | Film Test | Container Test (customization available) |
---|---|---|
Testing Range | 0.01∼1000 cm3/m2.d (standard) | 0.0001∼10 cm3/pkg.d (standard) |
0.1∼10,000 cm3/m2.d (optional) | ||
Resolution | 0.01 cm3/m2 .d | 0.0001 cm3/pkg.d |
Temperature Range | 150C∼550C (outside of supply scope), ±0.10C | |
Humidity Range | O%RH, 15%RH∼90%RH, 100%RH (outside of supply scope), ±1%RH | |
Standards To Follow | ISO 15105-2, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2 |
Configuration
No. | Product |
---|---|
2033101 | Martindale abrasion tester (4 head) |
2033106 | Specimen mounting weight |
2033107 | 38mm specimen cutter |
2033108 | 140mm specimen cutter |
Model | Rated Power | Internal Dimension(mm) D x W x H | External Dimension(mm) D x W x H | ||
---|---|---|---|---|---|
LRHS-S-NGF | 2.5 kw | 600 x 1270 | 750 x 1880 x 800 | ||
LRHS-B-NGF | 4.5 kw | 1820 x 1000 | 1400 x 2500 x 1500 |
Basic Specification | |||||
---|---|---|---|---|---|
Performance | PV Module Surface Temperature | 60oC | |||
Temperature Fluctuation | ±0.5oC | ||||
Temperature Resolution | 0.1oC | ||||
Center Distance of Lamp | 70mm | ||||
Illumination | Specimen surface Uniformlty of ±15% | ||||
Wind speed | 0.5 ∼ 1.0m/s | ||||
UVA-313 Warelength | 280nm ∼ 320nm | ||||
UVB-340 Warelength | 300nm ∼ 340nm | ||||
Lamp Brand | Q-lab x 6 | ||||
Material | External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Door | Manually operated sliding door with unlock button | ||||
Temperature Sensor | STT-R Platinum resistance | ||||
Air Circulation System | Imported Snail blower | ||||
Hand-held irradiation meter | Made by Beijing Normal University | ||||
Standard Configuration | UV-A x 4, UV-B x 4 , Specimen Holder x 1 unit , Hand-held irradiation meter x 1 | ||||
Safety Protection | Power leakage protection, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5oC∼+30oC <= 85% R.H |
Operation Display | Touch Screen | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Difference Range | 0-4000Pa | ||||||||||
Permeability Range | 0.1sim;12000mm/s | ||||||||||
Measuring Error | <= ±2% | ||||||||||
Measuring Unit | mm/s, cfm, cm3/cm2/s, l/m2/s, l/dm2/min, m3/m2/min | ||||||||||
Testing Area | 5cm2, 20cm2, 50cm2, 100cm2, Ф50mm(≈19.6cm2,Ф70mm (≈38.2cm2) |
||||||||||
Fabric Thickness | <=12mm | ||||||||||
Nozzle Parameter | Number | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Dia. mm | 0.8 | 1.2 | 2 | 3 | 4 | 6 | 8 | 10 | 12 | 16 | |
Power Supply | AC 220V 50/60Hz, 2KW | ||||||||||
Dimensions | 700 X 520 X 1100mm(LxWxH) | ||||||||||
Weight | 93kg | ||||||||||
Standard Accessories | 1 SET | Standard calibration plate | |||||||||
1 SET | Nozzle | ||||||||||
1 PC | Operation Software | ||||||||||
1 PC | Cable Connect with PC | ||||||||||
1 PC | Power Line | ||||||||||
Optional Accessories | Optional | Computer | |||||||||
Optional | Air Compressor |
Model | GT-C26A-1 | GT-C26A-2 |
---|---|---|
Testing Range | 500pa-200kpa | 5kpa-500kpa |
Water Pressure Increase Rate | 1kpa-30kpa | 1kpa-60kpa |
Accuracy | 0.2%F.S | |
Specimen Test Area | 100cm2, or 7.8cm2 (Option) | |
Testing Mode | Supercharge method, leaking method (set the pressure and time) | |
Test Unit | pa, mmHg, cmH2O | |
Power Supply | AC 220V 50/60HZ | |
Dimensions | 600 X 450 X 640mm(LxWxH) | |
Weight | 60kg |
Standard Accessories | 1Set | 100cm2 testing sets |
---|---|---|
1Set | Calibration plate | |
2pcs | Rubber ring | |
1pc | Power line | |
Optional Accessories | Optional | Fixtures of other testing range |
Model | ME-OV-9023A | ME-OV-9053A | ME-OV-9073A | ME-OV-9123A |
---|---|---|---|---|
Working size(mm) | 300x300x275 | 415x375x345 | 450x350x450 | 550x370x520 |
Power | 500W | 1000W | 1200W | 1500W |
Temperature range | RT+10-200oC | |||
Temperature resolution | 0.1oC | |||
Temperature fluctuation | ±1oC | |||
Timer | 0-9999min | |||
Voltage | 110V 60Hz /220V 50Hz | |||
Dimension(mm) | 400x570x630 | 510x650x700 | 620x620x720 | 720x740x650 |
Weight | 33kg | 49kg | 55kg | 65kg |
Salt Spray Test Chamber could evaluate the anti-corrosion ability of material and material coating, make a comparsion about the product techniques and quality of similar coating and products, It be used to test the electronic elements, and metal materials and industrial products.
Model | Volume(L) | Temperature Range (oC) |
Rated Power | Internal Dimension(mm) D x W x H | External Dimension(mm) D x W x H |
---|---|---|---|---|---|
LRHS-108-RJY | 108 | RT+5oC ∼ 55oC | 1.5kW | 450 x 600 x 450 | 780 x 1140 x 1050 |
LRHS-270-RJY | 270 | 1.8kW | 600 x 900 x 500 | 960 x 1460 x 1150 | |
LRHS-412-RJY | 412 | 4.0kW | 750 x 1100 x 500 | 1100 x 1730 x 1240 | |
LRHS-663-RJY | 663 | 5.0kW | 850 x 1300 x 600 | 1230 x 2150 x 1410 | |
LRHS-816-RJY | 816 | 6.0kW | 850 x 1600 x 600 | 1230 x 2450 x 1460 | |
LRHS-1080-RJY | 1080 | 6.5kW | 900 x 2000 x 600 | 1280 x 2850 x 1460 |
Basic Specification | |||||
Performance | Temperature Range | RT+5oC ∼ 55oC | |||
Air Saturator | RT+10oC ∼ 70oC | ||||
Temperature Fluctuation | ±0.5oC | ||||
Temperature Uniformity | <= 2.0oC | ||||
Salt fog fall-out Rate | 1∼2ml/80 cm2.h (Ave in 16 hours) | ||||
Air Pressure | 2.00±0.01 (kg/cm2) | ||||
Spray Method | Optional continuous/periodic test time: 1∼9999 H`M`S (Adjustable) | ||||
Period time | 1∼99 H , M , S (Adjustable) | ||||
Test specimen shelf | Test specimen shelf can meet the requirements of 15oC∼30oC tilt test | ||||
Material | Chamber material | Be made of imported reinforced hard PP plates with smooth and flat surface | |||
Saturated air cylinder | Made of imported high-quality mirror-finished stainless steel plates (SUS304) | ||||
Pipe | Reinforced fluorosilicone rubber tube | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass | ||||
Control System | breaker | Schneider miniature circuit breaker | |||
Heater | Steipped Nickel-chromium Wire Heater | ||||
Controller | 7'' HD true color LCD touch display Have the function of Real-time monitoring, and store 600 days of historical records, is allowed to export or upload data with U disc , also can realised remoto control |
||||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Standard Configuration | Round stick, V-shaped sample shelf, Glass nozzle, Funnel, Metering cylinder Flexible pipe | ||||
Safety Protection | Power leakage protection, Low water level protection, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5oC∼+30oC <= 85% R.H |
UCI probe types |
|
Leeb probe types |
|
Measuring range |
|
Measuring accuracy |
|
Standards |
|
Indenter | UCI probe - Diamond indenter Leeb probe - Hardened ball |
Measuring direction | Any direction 360o |
Data storage | Limited only by the memory card up to 32Gb |
Communication | Upload data to PC and export as a spreadsheet (USB cable and software included ) |
Hardness scales |
|
Materials |
|
Data display |
|
Indication | Color LCD display (320 x 240) |
Operating environment |
|
Power supply | DC 4,5V (3 pcs batteries AA) |
Instrument dimensions | 160 x 75 x 30mm |
Net weight | Approx. 0.3kg (without probe) |
Gross weight (package) | 2kg |
Battery life | Approx. 10 hours. |
Warranty | 3 (1+2) years |
GT-N29C Bursting Strength Tester has abundant functions, such as, parameter testing, parametric transformation, parameter adjusting, parameter memory and parameter print. All are in accordance with related national standards. It has data processing function which can directly output result of data statistics with convenient operation, easy regulation and stable performance.
Model | Volume(L) | Temperature Range (oC) |
Rated Power | Internal Dimension(mm) D x W x H | External Dimension(mm) D x W x H |
---|---|---|---|---|---|
LRHS-101B (R5) -LJ | 101 | A: -20∼150oC B: -40∼150oC C: -60∼150oC D: -70∼150oC E: or customized |
12.0kW | 450 x 450 x 500 | 1160 x 1000 x 1610 |
LRHS-225B (R5) -LJ | 225 | 14.0kW | 500 x 600 x 750 | 1210 x 1150 x 1870 | |
LRHS-504B (R5) -LJ | 504 | 16.0kW | 700 x 800 x 900 | 1260 x 1340 x 2070 | |
LRHS-800B (R5) -LJ | 800 | 18.0kW | 800 x 1000 x 1000 | 1370 x 1550 x 2170 | |
LRHS-1000B (R5) -LJ | 1000 | 20.0kW | 1000 x 1000 x 1000 | 1540 x 1490 x 2160 | |
Note: In the Model, the number means volume of test chamber's working room, and ABCD means the temperature range. For example, model LRHS-101B (R5) -LJ means the volume of this test chamber is 101L, and its temperature range is -20oC∼+150oC. LRHS-225B (R5) -LJ means the volume is 225L and the temeprature range is -60oC∼+150oC |
Basic Specification | |||||
Performance | Temperature Range | A: -20∼150oC, B: -40∼150oC, C: -60∼150oC, D: -70∼150oC, E : or customized | |||
Temperature Fluctuation | ±0.5oC | ||||
Temperature Uniformity | ±2.0oC | ||||
Ramp Rate | -55oC∼85oC <=15oC/min for heating (non-linear, based on on-load) 85oC∼ -55oC<=15oC /min for cooling (non-linear, based on on-load) Note: can be customized as per requirement |
||||
Material | External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Heating & Cooling System | Heater | Steipped Nickel-chromium Wire Heater | |||
Air Blower | Anti-temperature stainless fan blades with low noise | ||||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
Refrigerant | R404A or/and R23 (eco-friendly) | ||||
Condenser | Plate-type heat exchanger | ||||
Control System | Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | ||||
Program | 1∼1000 programs, 1∼999 steps for per program, Max 99hrs 59mins for per program. 10 programs can be interlinked. | ||||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Running Model | Constant/Fix-value Model and Programmable Model | ||||
I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5oC∼+30oC <= 85%R.H | ||||
Test Standards (not limited to) | IEC60068-2-1 IEC60068-2-2 IEC60068-2-78 IEC60068-2-30 |
Light Sources | Color Viewing Booths Application | Color Temperature(K) | Power (W) |
---|---|---|---|
D65 | International Standards Artificial Daylight | 6500 | 18 |
TL84 | Applied to Stores in Europe, Japan and China | 4000 | 18 |
CWF | (Call White Fluorescent) American Standard | 4150 | 18 |
F/A | "Sun-Setting Light Yellow" Incandescent Light Source(Imitation of Sunset) | 2700 | 40 |
UV | Viewing Under Ultraviolet Light to Detect and Evaluate Optical Brightners or Fluorescent Pigments | Wavelength: 365nm | 20 |
U30 | Warm White Fluorescent, American Standard | 3000 | 18 |
Models | Configured Light Sources | Weight | Dimensions(LxWxH) |
---|---|---|---|
Gt-D08(4) | D65. TL84. F/a. UV | 24Kg | 710 X 405 X 570mm |
GT-D08(5) | D65. TL84. CWF. F/A. UV | 28kg | 710 X 405 X 570mm |
GT-D08(6) | D65. TL84. CWF. F/A. UV. U30 | 34kg | 710 X 530 X 570mm |
GT-D08(7) | D65. TL84. CWF. F/A. UV. U30. INCA | 34kg | 710 X 530 X 570mm |
GT-D08(12) | D65. TL84. CWF. F/A. UV. U30 | 65kg | 1310 X 600 X 800mm |
Standard Accessories | 1 SET | Tube |
---|---|---|
1 PC | Power Line | |
Optional Accessories | Optional | 45o Standard Grandstand |
Model | Volume(L) | Temperature Range (oC) |
Rated Power | Internal Dimension(mm) D x W x H | External Dimension(mm) D x W x H |
---|---|---|---|---|---|
LRHS-101-NO3 | 101 | 25oC ∼ 65oC | 4.0kw | 450 x 450 x 500 | 1160 x 1000 x 1800 |
LRHS-225-NO3 | 225 | 5.5kw | 500 x 600 x 750 | 1220 x 1150 x 2040 | |
LRHS-504-NO3 | 504 | 7.0kw | 700 x 800 x 900 | 1400 x 1350 x 2250 | |
LRHS-800-NO3 | 800 | 9.0kw | 800 x 1000 x 1000 | 1520 x 1540 x 2300 | |
LRHS-1000-NO3 | 1000 | 11.5kw | 1000 x 1000 x 1000 | 1720 x 1540 x 2300 |
Basic Specification | |||||
---|---|---|---|---|---|
Performance | Temperature Range | 25oC ∼ 65oC | |||
Temperature Fluctuation | ±0.5oC | ||||
Temperature Uniformity | <= 2.0oC | ||||
Temperature change speed | ± 2.0oC | ||||
Humidity Range | 40% ∼ 95% | ||||
Humidity Deviation | +2 / -3% R.H | ||||
Ozone Concentration | 50∼1000pphm or 50∼300ppm | ||||
Ozone Concentration Deviation | <= ±10% | ||||
Air Flow Rate | 8∼16mm/s | ||||
Rotate speed | 1∼3r/min (adjustment) | ||||
Time Setting Range | 1∼9999 h/m/s adjustable | ||||
Material | External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Heating & Cooling System | Heater | Steipped Nickel-chromium Wire Heater | |||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
Refrigerant | R404A or R23 (eco-friendly) | ||||
Condenser | Plate-type heat exchanger | ||||
Control System | Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder platform x 1 | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5oC∼+30oC <= 85% R.H |