Our Products
Oil Plant And Extraction Machinery
2 Products availableEpoxy Coatings
2 Products availableMeasuring Instruments
2 Products availableMaterial Testing Equipment
1 Products availableInsize Thickness Gauge
1 Products availableInstruments used in assay offices and hallmarking institute for material analysis of gold and precious metals must meet the strictest of specification. Besides gold content analysis, it is necessary to be able to determine other precious metals or prohibited substances. Well established in the industry, X-ray fluorescence analysis offers an excellent alternative to the widely-used fire assay method (cupellation) for analyzing precious metals and their composition without damaging the item. The high end measurement system FISCHERSCOPE X-RAY XAN 250 was developed specifically for high precision analysis of precious metals as required for hallmarking and assay offices.
Additional Information:
Delivery Time : 3-4 Weeks
Gold testing machine in hallmarking centres: XAN-FD is a fast and non-destructive coating thickness measurement and material analysis. These are compact in size and widely applicable as an energy-dispersive X-ray fluorescence measuring instrument.
Our machines are extensively used for non-destructive thickness measurements and material analysis. These are fitted with electrically changeable apertures and primary filters and modern silicon PIN detector for excellent detection sensitivity and high accuracy. These can be used for coating systems as well as solid and liquid Samples can be analyzed standard-free. Besides, these can easily measure up to 24 elements in a Range from aluminum (13) to uranium (92) simultaneously.
Our machines are acclaimed for their long term stability, excellent accuracy, long term stability and ergonomic design. These are very easy to operate and acclaimed for fast calculation and quick data presentation. These are well suited for measuring and analyzing thin coatings, even with very complex compositions or small concentrations.
General Specifications
X-ray detection
Click Here For More Details
Download
THE NEW DMP SERIES
Experience the next level of tactile coating measurement
Gauge family for measuring coating thickness.
TOUGHER THAN THE CIRCUMSTANCES. MORE PRECISE THAN THE REST.
The new DMP series sets the standard for tactile and non-destructive coating thickness measurement of magnetized and non-magnetized base materials. The robust and modern design, optimized functionalities, digital probes, and intuitive Tactile Suite software make these compact handheld devices your perfect companions for any measuring requirement.
-Built to last: Next level quality and durability thanks to all-aluminum housing.
-Full measuring control: Feedback via light, sound and vibration whether measured values are within tolerance
-Digital probes: Fully digitized probes for the most demanding measurement tasks.
The all-around capabilities of coating thickness
measurement
Burnished rails
Features
Universal device series for tactile coating thickness
measurement thanks to enormously wide probe
portfolio
Test method: Magnetic induction and amplitude-sensitive eddy current method
Measured value memory: DMP10/20: 10, 000 in one
batch, DMP30/40: 250, 000 in 2, 500 batches
Measurement range: Depending on the combination
of coating and base material and the used probe
Robust aluminium housing with protection class IP64
Replaceable Li-Ion battery for >24h operating time
Easy data transfer via USB-C and Bluetooth
Limit monitoring via light, sound and vibration
Digital and analog probe
The range of Lead Frame Coating is uniquely designed with high-precision, programmable XY-stage as well as an electrically.
The user-friendly bench-top instruments are acclaimed for sample stage moves into the loading position automatically in case the protective hood is opened.
These are solid and strong range that ensure longer stability. With laser pointer works as a positioning help and support the rapid alignment of the sample to be measured.
These are carefully operated through the dominant and user-friendly WinFTM® software designed as per German regulations Deutsche R ntgenverordnung-rov". Its whole operation as well as evaluation of measurements and the clear arrangement of measurement data is performed on a PC through software.
Typical areas of application are
General Specification
Watches Coating machine XDAL237 is engineered to use as X-ray fluorescence measuring instrument with a modern programmable XY-stage and Z-axis for automated measurements. Our Watches Coating Thickness device is ideal to test the thin coatings in Gold Hallmarking, Manufacturing and Assaying Centres. They are extensively used for non-destructive measurements and analysing very thin coatings.
Design
Application Areas
General Specification
FISCHERSCOPE X-RAY XDL X-ray fluorescence measuring device for manual as well as automated coating thickness measurements on decorative and protective coatings. They are universally applicable energy dispersive X-ray measuring instruments used for non-destructive thickness measurements as well as analysis of thin coatings for the measurements on mass-produced parts as well as printed circuit boards. FISCHERSCOPE X-RAY XDL is designed under the direction of practiced quality controllers following the international industrial standards.
Models
XDL 210: Plane support stage, fixed Z-axis
XDL 220: Plane support stage, motor-driven Z-axis
XDL 230: Manually operable XY-stage, motor-driven Z-axis
XDL 240: Motor-driven XY-stage that moves into the loading position automatically, when the protective hood is opened. Motor-driven programmable Z-axis
Applications
Measurement of electroplated mass-produced parts
Study of thin coatings like decorative chromium-plating
Examination of functional coatings in the electronics as well as semiconductor industries
Automated measurements such as printed circuit boards
Solution study in the electroplating
Coating thickness gauge for electroplating and electroless coatings XDV-µ or X-Ray Fluorescence Tester is available in various technical specifications. These are widely used for non-destructive analyses and measurements of coating thickness on very small components and structures, even with complex coating systems.
Applications
The high-end measurement system Fischerscope X-Ray XAN 250 was developed specifically for high-precision analysis of precious metals as required for Hallmarking and assay offices. Gold testing machine in assaying centres: XAN250 is engineered using best available techniques. These are high performance X-ray fluorescence measuring instruments widely used for fast and non-destructive material analysis and coating thickness measurement. Compact sized these devices are acclaimed for high performance, longer service life and accurate measurement.
Environmental Conditions
Evaluation Unit
Details 01
Application |
|
---|---|
Design |
|
Specification |
Intended use Energy dispersive x-ray fluorescence measuring instrument (EDXRF) to determine thin coatings, Gold Testing, Gold analysis, trace elements and alloys Element range Aluminium (13) to Uranium (92) up to 24 elements simultaneously Design Bench top unit with upwards opening hood Measuring direction Bottom up |
X- Ray Source |
X-ray tube Micro-focus tungsten tube with beryllium window Aperture (Collimator) 4x changeable: 0.2 mm (7.9 mils), 0.6 mm (23.6 mils), 1 mm (39.4 mils), 2 mm (78.7 mils), others on request Primary filter 6x changeable: Ni, free, Al 1000 m (39.4 mils); Al 500 m (19.7 mils); Al 100 m (3.9 mils); Mylar 100 m (3.9mils) Measurement spot Depending on the measuring distance and on the aperture, the actual measurement spot size is shown in the video image. Smallest measurement spot: approx. 0.3 mm (11.8 mils) |
X-Ray Detection |
X-ray detector Silicon Drift Detector (SDD), peltier-cooled Resolution (fwhm for Mn-K±) 160 eV Measuring distance 0....10 mm (0...0.4 in) Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary. |
Sample Stage |
Design Fixed sample support Usable sample placement area 310 x 320 mm (12.2 x 12.6 in) Max. sample weight 13 kg (29 lb) Max. sample height 90 mm (3.5 in) |
Dimensions |
External dimensions Width x depth x height 403 x 588 x 365 mm (16 x 23.2 x 14.4 in) Weight Approx. 45 kg (99 lb) |
Details 02
Standards | XAN 250 | XAN 252 |
---|---|---|
CE approval | EN 61010 | EN 61010 |
X-Ray standards | DIN ISO 3497 and ASTM B 568 | DIN ISO 3497 and ASTM B 568 |
Approval | Fully protected instrument with type approval according to the German regulations "Deutsche Rontgenverordnung-RoV". | Individual acceptance inspection as a fully protected instrument according to the German regulations "Deutsche Rontgenverordnung-Ro |
Download
The instrument of Electroplating Thickness ensures quick and exact materials analysis with user-friendly features. The array is ideal for the analysis of varied precious metal as well as gold alloys. The collection comes with geometric arrangement of hardware components. X-ray source as well as detector is situated below the measurement chamber and the measurement is conducted from bottom to top for easy & swift positioning of the samples. The range comes in varied versions only differ in terms of detectors, number of apertures, X-ray tubes, and filters.
Features
Applications
Our Electrical Conductivity Measurement instrument - sigmascope SMP350 is designed with utmost precision to measure the electrical conductivity of metallic conductor accurately and precisely. Our Electrical Conductivity Sigmascope SMP350 is also used for assessing hardness and strength of various heat treated materials. Electrical conductivity is a basic material property which gives information about metal's ability for conducting electrical current.
Features
Typical areas of application are
Technical data