Our Products
Plastic Testing Equipment
2 Products availableLaboratory Apparatus
1 Products availableGas Analyzers
1 Products availableOur offered Product range includes Systech Illinois Water Vapor Permeation Analyzer, Omnimark Moisture Analyzer and Moisture Analyzer.
We have made a name for ourselves as a prominent name by offering a huge assortment of Systech Illinois Water Vapor Permeation Analyzer. The vendors we procure it from are known to deliver nothing short of best quality. The high efficiency, smooth operation and reliability make our product admired not only in India but also worldwide. Our customers may get their order delivered at our doorstep at reasonable rates.
Description :
Features and Benefits :
Applications :
Specifications
Industry | Packaging |
---|---|
Gas | Water Vapor |
Application | Permeation |
Measurement Range | 7001 Unmasked 0.002 – 10 g/m2/day, Masked 0.02 – 70 g/m2/day. |
Measurement Range | 7002 Unmasked 0.002 – 70 g/m2/day, Masked 0.02 – 1000 g/m2/day |
Test Temperature Range | 5 to 50oC (41 to 122oF) |
Test RH Range | 20 to 90% RH |
Dimensions | 533 x 533 x 305 (mm) |
Weight | 23.6 kg |
We present Omnimark Moisture Analyzer to our admired customers. Sustaining supreme quality tops our priority list. For that purpose, we have an exceptional team of capable quality auditors. This team matches the highest parameters of quality set by industry. It is popular for its low level moisture performance and built-in temperature and weight calibration. We make certain its durability by the protective packaging in which we provide our product.
Description :
Features :
Specifications
Method of Measurement | Loss on drying via four infrared quartz cylinders |
---|---|
Modular configuration | Control and Heater modules (Optional: up to 4 heater modules) |
Temperature setting/control | 30-210 oC in one degree increments via RTD sensor, +/- 1 oC |
Temperature steps | Programmable one or two with selectable ramp rate |
Standby temperature | 30-160 oC in one degree increments with selectable equilibration time |
Temperature display | Display of both target and current temp at each stage of testing and standby |
Conserve mode clock | Programmable time by day of week to shut down and wake up analyzer |
Balance module design | Monolithic weighing cell with protective stainless steel cover |
Balance calibration | Internal calibration weight or external weights accepted for manual calibration |
Ideal weight | Audio and visual display for programmable target sample weight addition |
Target limit alert | Minimum and maximum programmable limits and screen alert when test done |
Program storage | 300 programs with unique settings, alphanumeric naming |
Result storage | 999 results with statistics: Average, SD, RSD, high and low |
Units of measure of results | Weight, %Moisture, %Solids, %Volatiles, Fuel Moisture, PPM, mg/L |
Endpoint determination | Actual slope, Calculation and Time modes |
Sample ID | Numeric, incremental, alphanumeric or turned Off |
Modes of operation | Standard test, Syringe, “Splash” method or Concentration modes |
Security mode | Selectable setup and operation protection with numeric code |
Graph mode | Graph of temperature and percentage over time |
Display | Quarter VGA with contrast adjustment (black on white or white on black) |
Keypad | Sealed membrane with audible tactile feedback |
Internal printer | Built-in thermal, 40 character graphic with selectable format |
Power requirements | 90-250 VAC 50/60 Hz self adjusting power supply |
Dimensions (L x W x H) | 16.25” x 19.5” x 9.25”, shipping weight 35lbs (includes one heater module) |
Warranty period | 2 years, complete parts and labor |
The principle of operation of the Mark 3 is loss on drying. The instrument finalizes on a programmed rate of weight change compared to the actual initial weight of the sample over a programmed window of time.
The Mark 3 analyzer is compared to a convection oven, vacuum oven or Karl Fischer titration to verify accuracy and precision.
Accuracy is stated by the average of repeat tests compared to the standard AOAC or ASTM reference value while precision is established by the standard deviation of repeat tests on the Mark 3.
Method of Measurement | : | Loss on drying via four infrared quartz cylinders |
Modular configuration | : | Control and Heater modules (Optional: up to 4 heater modules) |
Temperature setting/control | : | 30-210 °C in one degree increments via RTD sensor, +/- 1 °C |
Temperature steps | : | Programmable one or two with selectable ramp rate |
Standby temperature | : | 30-160 ° C in one degree increments with selectable equilibration time |
Temperature display | : | Display of both target and current temp at each stage of testing and standby |
Conserve mode clock | : | Programmable time by day of week to shut down and wake up analyzer |
Balance module design | : | Monolithic weighing cell with protective stainless steel cover |
Balance calibration | : | Internal calibration weight or external weights accepted for manual calibration |
Ideal weight | : | Audio and visual display for programmable target sample weight addition |
Target limit alert | : | Minimum and maximum programmable limits and screen alert when test done |
Program storage | : | 300 programs with unique settings, alphanumeric naming |
Result storage | : | 999 results with statistics: Average, SD, RSD, high and low |
Units of measure of results | : | Weight, %Moisture, %Solids, %Volatiles, Fuel Moisture, PPM, mg/L |
Endpoint determination | : | Actual slope, Calculation and Time modes |
Sample ID | : | Numeric, incremental, alphanumeric or turned Off |
Modes of operation | : | Standard test, Syringe, “Splash” method or Concentration modes |
Security mode | : | Selectable setup and operation protection with numeric code |
Graph mode | : | Graph of temperature and percentage over time |
Display | : | Quarter VGA with contrast adjustment (black on white or white on black) |
Keypad | : | Sealed membrane with audible tactile feedback |
Internal printer | : | Built-in thermal, 40 character graphic with selectable format |
Power requirements | : | 90-250 VAC 50/60 Hz self adjusting power supply |
Dimensions (L x W x H) | : | 16.25” x 19.5” x 9.25”, shipping weight 35lbs (includes one heater module) |
Warranty period | : | 2 years, complete parts and labor |