Diode Laser System

  • Frequency Aestheticversion, 1-8Hz / Medical version, 1-10Hz
  • Warranty Oneyear or 10, 000, 000 shots
  • LCD Screen 10.4 inch color touch screen
  • Light Source Diodelaser module (AnSnbonded)
  • Laser Wavelength 808nm
  • Laser Power 400W(Max), Micro channel, ContinuousWoking
  • Software Versin Aesthetic& Medical
  • Working Mode Frequency modulation and Pulse modulation
  • Energy Density Aesthetic version-HR:45J/cm2;FHR:10J/cm2
  • Medical Version-HR 80J/cm2;FHR:15J/cm2
  • Spot Size 12mmx12mm
  • Cooling Contacting cooling at -10C
  • Electrical Requirement AV220V±10%, 50Hz±1Hz/AV110V±10%, 60Hz±1Hz
  • Net Weight 18Kg
  • Physical Dimension 510mmx330mmx250mm

Advantages

  • 10C Super Chilled Tip - The treatment tip can be chilled at -10and the central area of sapphire can reach at -13. It can extremely increase the comfort of treatment and deliver more energy without pain.
  • 1.5 Kg Net Weight, 40% Lighter Than The Normal - Small and light design of handpiecemakes it feel much more comfortable and relaxed during treatment.
  • 10 Million Shots Warranty for Handpiece - The cutting edge Micro channel technology integrating with the latest version AuSnAuSn solder bonded lasers ensure a high efficiency of cooling and a long lifespan for laser module.

Details


Download Detail File : Click Here
View Complete Details

Manual Dental Laser System

  • Length 1 .5m
  • Wavelength 810 nm +/- 10nm
  • Beam Divergence 25 (NA = 0, 22)
  • Pulse Mode Power 1 – 4 W, Dependent On the Operation Mode
  • Continuous Power 1 – 4 W (CW)
  • Frequency 0.2-200Hz
  • Aiming Laser Laser Diode
  • Output Performance < 1 mW
  • Wave Length 635 nm
  • Transmitting System Hpcs Glass Fibre, Na = 0.37
  • Voltage Supply 110 V AC, 50/60 Hz
  • Current Consumption 0.9 A
  • Protection Class 1 B, Not Waterproof, Flammable
  • Laser Cooling Unit Tec and Air-cool

Documents provided for device operator

  • Operating instructions
  • Inspection report
  • Warranty card


Manufacturer's liability

  • Setup and start up of the device is carried out by company staff or persons entitled by manufacturer to do so (obligatory subsequent to course).
  • Installation and safety measures comply with national standards and regulations.
  • The device is operated in accordance with the operating instructions.
  • No changes are made in the device or its accessories unless approved by the manufacturer.


WarrantyA 12-month warranty is provided for the Dental laser system. If a deficiency is manifested within 12 months that is not the result of improper handling or operation, the right of the purchaser to subsequent repair and restitution shall be valid instead of the purchaser's right to price reduction or contract annulment

Accessories
The following accessories are available for the laser system:

  • Instruction Manual
  • Fibre 400 μm
  • Footswitch
  • Interlock
  • Fibre holder
  • Power cable
  • Hand piece
  • Protective goggles

Details


Download Detail File : Click Here
View Complete Details

Diode Laser Hair Removal System

  • Light Source Diode (continuous Wave)
  • Laser Wavelength 808nm
  • Modes Fhr Mode, Hr Mode
  • Light Spot Size 12mm×12mm
  • Energy Density Up to 120j/cm2(hr Mode), Up to 20j/cm2 (fhr Mode)
  • Pulse Width 10~400ms
  • Repetition Rate 10hz At Maximum
  • Input Power Supply AC230V±10%, 15A, 60/50Hz and AC110V± 10%, 60Hz (optional), 110/220V 15A, 50/60Hz at maximum
  • Output Direct Coupling Through Sapphire Tips
  • Duachill Skin Protection Cooling 4ºC (Contact cooling)
  • Dimension 380mm×540mm×1250mm

Advantages

  • This product offers comfortable and safe hair removal through the sapphire contact cooling at 0ºC to protect the skin so that users almost may not feel pain.
  • The optimum 400w diode laser system keeps stable laser output and extra long pulse.
  • Our product is compatible with double hair removal modes, namely traditional (HR) mode and on-motion (FHR) mode. In the latter mode, it scans by huge light spot in size of 12×12mm2 and the repetition rate can be maximized to10Hz.
  • The particular light emission technology with double pulse maximizes the comfort and efficiency of treatment.

Case Studies Garph


Download Detail File : Click Here
View Complete Details

Fractional CO2 Laser Machine

  • Condition New
  • Automatic Grade Automatic
  • Driven Type Electric

Application

  • Skin renewing and resurfacing
  • Wrinkle removal, skin tightening
  • Acne and acne scar removal
  • Smooth burnt scars and surgery scars, etc
  • Remove intractable chloasmas and pigmentation
  • Sun damage recovery
  • Particular designed intelligent laser control system ensures a precise treatment
  • RF-exited CO2 laser energy shooting is an even steady and safe treatment process.
  • Wide range application, effective treatment
  • Easy and fast treatment.
  • Large-sized colorful touch screen, with maniable handpiece

Comparison Of CO2(RF) & CO2

Comparison CO2(RF) Co2
Laser Source RF CO2 Tube (from U.S.A) Co2 Tube
Life Time 20,000 h 10,000 h
Dot Size 0.1mm(Diameter) 0.2-0.3mm(Diameter)
Cooling System Fan cooling Fwater cooling

Specification

General Specification Wavelength 10.6μm, far-infrared laser
Aiming Beam Less than 2mW, red semiconductor laser
Scan Mode Laser Energy 5-45mj, step value 5mj
Figure Option 1. Square or rectangle, min 3×3mm; max 20×20mm, step value 1mm., 2. Round, min 3mm (diameter), max 20mm (diameter), step value 1mm., 3. Ellipse, min 3×8mm, max, 15×20mm, step value 3mm.
Energy Repeat 1-5 (When increasing energy repeat, laser energy is increased synchronously, max total energy 225mj.)
Dot Density 36/49/64/100/144/225 dots in 1cm2
Mode Normal, scan sequentially line by line.Random, scan randomly, to decrease thermal accumulation. This function is not available for rectangle.
Normal Mode Laser Energy 1-30W, step value 1W
Ultra Pulse(Super) 1. Average power: 1w~30w; 2. Pulse frequency: 300Hz~950Hz optional
Pulse 1. Average power: 1w~30w; 2. Pulse duration: 0.1s~1s optional
Continuous Wave 1w~30w
Repeat 1. Average power: 1w~30w; 2. Pulse duration: 0.1s~1s optional,off time : 1ms
Dimension 50cm×60cm×100cm
Weight 50Kg