Our offered Product range includes APM 460 DXNL Respirable Dust Sampler, APM 460BL Respirable Dust Sample, APM 550 MFC Respirable Dust Sampler, APM 550 EL Respirable Dust Sampler and APM 550 Respirable Dust Sampler.

APM 460 DXNL Respirable Dust Sampler

  • Feature Brushless regenerative blower with very little noise., Heavy duty Induction motor fitted in blower requires no maintenance.
APM 460 DXNL is one of the most advanced PM10 samplers being manufactured in India. It is based on CSIR NEERI technology and is the only PM 10 sampler in India that conforms to BIS 5182 (Part 23): 2006Automatic flow controller and auto shut off In all previous models of particulate samplers in use in the country, the sampling rate varies with dust loading on the filter and fluctuates with changes in the mains voltage. The APM 460 DXNL uses an electronic flow controller to automatically maintain constant sampling rate through the filtercyclone assembly. The size fractionating cyclone of the APM 460 DXNL thus operates close to its designed separation velocity resulting in a sharper cut-off for particulates larger than 10 microns. When the dust load on filter becomes excessive and exceeds the capacity of the blower the electronic circuits provided in the flow controller automatically shut down the machine.
View Complete Details

APM 460BL Respirable Dust Sample

  • Flow Rate: 0.9 – 1.4 m3 /min free flow
  • Size & Weight: 430 x 320 x 930mm, 45 Kg
  • Sampling Time: 28 hours (maximum)
The APM 460 sampler uses an improved cyclone with sharper cutoff (D50 at 10 microns) to separate the coarser particulates from the air stream before filtering it on the glass microfibre filter. By using the APM 460, measurement of Respirable Particulate Matter can be done accurately and TSPM can also be assessed by collection of dust retained in the cyclone cup.APM 460 BL comes with an in-built voltage stabilizer to compensate for voltage fluctuations. This model has been made more user-friendly by providing a lighting arrangement for night operation, tool box within the instrument, softer handles, lockable top-cover and wheels for easy transportation. The cabinet design has also been improved to prevent entry of rain water and dust into the machine.
View Complete Details

APM 550 MFC Respirable Dust Sampler

  • Flow Rate: 1 m3/hr controlled by mass flow controller
  • Vacuum Pump: Oil Free, non-pulsating pump driven by induction motor for stable flow rate
  • Calibration unit: Leak Check & Flow rate measurement adaptor
Ambient air enters the APM 550 MFC sampler through an omnidirectional inlet designed to provide a clear aerodynamic cut-point for particles larger than 10 microns. The air stream then passes through a WINS Impactor that retains the fraction between PM10 and PM2.5. The PM10 and PM2.5 impactors used in the APM 550 MFC are based on designs standardized by USEPA and as such the system complies with international norms for PM2.5 Samplers. The sampling rate is held constant at 1 m3hr by a mass flow controller. An ambient air temperature sensor and barometric pressure sensor have been provided to automatically compensate for temperature and pressure while reporting flow rate in volumetric flow units. The APM 550MFC has an in-built data logger that records air temperature, filter temperature, flow rate and also totalizes and records the volume of air sampled. A PC based software is provided to download the data for audit.features: PM 10 and PM 2.5 Impactors of sampler based on designs standardized by US EPA.Flow Control based on Mass Flow measurements to remove errors due to pressure, temperature changes (of both ambient air and filter).Auto shut off if flow rate drops significantly below 1 m3hr.Microcontroller based datalogger records Air Temp., Filter Temp. and Flow rate.
View Complete Details

APM 550 EL Respirable Dust Sampler

  • Size Selective inlets: PM 10 Impactor and WINS Impactor for PM 2.5 conform to USEPA design
  • Vacuum Oil Free, non-pulsating pump driven by induction motor for stable flow rate
  • Display: Large 40 Ch. X 4 line back lit LCD provides all system parameters at a glance
he APM 550 system is a manual method for sampling fine particles (PM2.5 fraction). Ambient air enters the APM 550 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM2.5 impactor are passed through a 47mm diameter Teflon filter membrane that retains the fine particulate matter APM 550 EL keeps the sampling rate constant at 1m3hr by a microprocessor based electronic flow controller that automatically compensates for increasing pressure drop due to dust deposit on the filter. An ambient air temperature sensor and barometric pressure sensor have been provided to automatically provide temperature and pressure correction while reporting flow rate in volumetric flow units. An additional filter pressure sensor is also provided to continuously monitor and record the filter pressure and the system terminates the sample collection if the pressure drop across the filter exceeds a safe limit. The APM 550 EL has an in-built USB Flash memory based data logger that records Filter ID, air temperature, filter temperature, barometric pressure, flow rate, Coefficient of Variation (CV) and also totalizes and records the volume of air sampled. A PC based software is provided to download the data for audit and prepare an intelligent report highlighting all important information in a convenient graphical format.
View Complete Details

APM 550 Respirable Dust Sampler

  • Filter Filter holder designed to accept any standard 47 mm diameter filter media
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Vacuum Pump: Oil Free, non-pulsating pump driven by induction motor for stable flow rate
The APM 550 system is a manual method for sampling fine particles (PM2.5 fraction) and is based on impactor designs standardized by USEPA for ambient air quality monitoring. Ambient air enters the APM 550 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM 2.5 impactor are passed through a 47 mm diameter Teflon filter membrane that retains the fine particulate matter. The sampling rate of the system is held constant at 1 m3hr by a suitable critical orifice. The standard system is supplied with a Dry Gas Meter to provide a direct measure of the total air volume sampled. Special features: PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPATwo part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperatureImported brush-less pump with a low noiseLower sampling rate of 1m3hr reduces filter choking even in areas having high FPM levelsCritical Orifice maintains constant sampling rate of 1 m3hourCompact and portable
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Pollution Control Machines & Devices from Delhi, Delhi by Envirotech Instruments Private Limited
Post Buy Requirement

Pollution Control Machines & Devices

We offer the best product range of APM 460 DXNL Respirable Dust Sampler, APM 460BL Respirable Dust Sample, APM 550 MFC Respirable Dust Sampler, APM 550 EL Respirable Dust Sampler and APM 550 Respirable Dust Sampler.

APM 460 DXNL Respirable Dust Sampler

  • Feature Brushless regenerative blower with very little noise., Heavy duty Induction motor fitted in blower requires no maintenance.
APM 460 DXNL is one of the most advanced PM10 samplers being manufactured in India. It is based on CSIR NEERI technology and is the only PM 10 sampler in India that conforms to BIS 5182 (Part 23): 2006Automatic flow controller and auto shut off In all previous models of particulate samplers in use in the country, the sampling rate varies with dust loading on the filter and fluctuates with changes in the mains voltage. The APM 460 DXNL uses an electronic flow controller to automatically maintain constant sampling rate through the filtercyclone assembly. The size fractionating cyclone of the APM 460 DXNL thus operates close to its designed separation velocity resulting in a sharper cut-off for particulates larger than 10 microns. When the dust load on filter becomes excessive and exceeds the capacity of the blower the electronic circuits provided in the flow controller automatically shut down the machine.
View Complete Details

APM 460BL Respirable Dust Sample

  • Flow Rate: 0.9 – 1.4 m3 /min free flow
  • Size & Weight: 430 x 320 x 930mm, 45 Kg
  • Sampling Time: 28 hours (maximum)
The APM 460 sampler uses an improved cyclone with sharper cutoff (D50 at 10 microns) to separate the coarser particulates from the air stream before filtering it on the glass microfibre filter. By using the APM 460, measurement of Respirable Particulate Matter can be done accurately and TSPM can also be assessed by collection of dust retained in the cyclone cup.APM 460 BL comes with an in-built voltage stabilizer to compensate for voltage fluctuations. This model has been made more user-friendly by providing a lighting arrangement for night operation, tool box within the instrument, softer handles, lockable top-cover and wheels for easy transportation. The cabinet design has also been improved to prevent entry of rain water and dust into the machine.
View Complete Details

APM 550 MFC Respirable Dust Sampler

  • Flow Rate: 1 m3/hr controlled by mass flow controller
  • Vacuum Pump: Oil Free, non-pulsating pump driven by induction motor for stable flow rate
  • Calibration unit: Leak Check & Flow rate measurement adaptor
Ambient air enters the APM 550 MFC sampler through an omnidirectional inlet designed to provide a clear aerodynamic cut-point for particles larger than 10 microns. The air stream then passes through a WINS Impactor that retains the fraction between PM10 and PM2.5. The PM10 and PM2.5 impactors used in the APM 550 MFC are based on designs standardized by USEPA and as such the system complies with international norms for PM2.5 Samplers. The sampling rate is held constant at 1 m3hr by a mass flow controller. An ambient air temperature sensor and barometric pressure sensor have been provided to automatically compensate for temperature and pressure while reporting flow rate in volumetric flow units. The APM 550MFC has an in-built data logger that records air temperature, filter temperature, flow rate and also totalizes and records the volume of air sampled. A PC based software is provided to download the data for audit.features: PM 10 and PM 2.5 Impactors of sampler based on designs standardized by US EPA.Flow Control based on Mass Flow measurements to remove errors due to pressure, temperature changes (of both ambient air and filter).Auto shut off if flow rate drops significantly below 1 m3hr.Microcontroller based datalogger records Air Temp., Filter Temp. and Flow rate.
View Complete Details

APM 550 EL Respirable Dust Sampler

  • Size Selective inlets: PM 10 Impactor and WINS Impactor for PM 2.5 conform to USEPA design
  • Vacuum Oil Free, non-pulsating pump driven by induction motor for stable flow rate
  • Display: Large 40 Ch. X 4 line back lit LCD provides all system parameters at a glance
he APM 550 system is a manual method for sampling fine particles (PM2.5 fraction). Ambient air enters the APM 550 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM2.5 impactor are passed through a 47mm diameter Teflon filter membrane that retains the fine particulate matter APM 550 EL keeps the sampling rate constant at 1m3hr by a microprocessor based electronic flow controller that automatically compensates for increasing pressure drop due to dust deposit on the filter. An ambient air temperature sensor and barometric pressure sensor have been provided to automatically provide temperature and pressure correction while reporting flow rate in volumetric flow units. An additional filter pressure sensor is also provided to continuously monitor and record the filter pressure and the system terminates the sample collection if the pressure drop across the filter exceeds a safe limit. The APM 550 EL has an in-built USB Flash memory based data logger that records Filter ID, air temperature, filter temperature, barometric pressure, flow rate, Coefficient of Variation (CV) and also totalizes and records the volume of air sampled. A PC based software is provided to download the data for audit and prepare an intelligent report highlighting all important information in a convenient graphical format.
View Complete Details

APM 550 Respirable Dust Sampler

  • Filter Filter holder designed to accept any standard 47 mm diameter filter media
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Vacuum Pump: Oil Free, non-pulsating pump driven by induction motor for stable flow rate
The APM 550 system is a manual method for sampling fine particles (PM2.5 fraction) and is based on impactor designs standardized by USEPA for ambient air quality monitoring. Ambient air enters the APM 550 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM 2.5 impactor are passed through a 47 mm diameter Teflon filter membrane that retains the fine particulate matter. The sampling rate of the system is held constant at 1 m3hr by a suitable critical orifice. The standard system is supplied with a Dry Gas Meter to provide a direct measure of the total air volume sampled. Special features: PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPATwo part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperatureImported brush-less pump with a low noiseLower sampling rate of 1m3hr reduces filter choking even in areas having high FPM levelsCritical Orifice maintains constant sampling rate of 1 m3hourCompact and portable