Post Buy Requirement

Our Products

  1. Modular Office Workstation 3 Products available
  2. Filters & Filtration Systems 3 Products available
  3. Clean Room Equipment

    2 Products available
  4. Oil Extraction Machine

    2 Products available
  5. Automotive Cleaners

    1 Products available
  6. Filters

    1 Products available
  7. Industrial Scrubbers

    1 Products available
  8. Safety System & Equipments

    1 Products available
  9. Curtains

    1 Products available
  10. Air Purifiers

    1 Products available
  11. Others Products 1 Products available

Other Products / Services

We offer a complete product range of Electrostatic Cleaner

Laminar Flow Workstations

  • Feature Well lit work surface Low vibration and noise Convenient service access Easy to reassemble
The design allows them to be used as individual units, or with side panels removed, which can be joined together for pass through assembly. Noise is minimized by designing a special type of air plenum. Vibrations are reduced to the work surface by mounting motor-blower assembly on springs
View Complete Details

FUME EXTRACTOR AND OIL MIST COLLECTER

Pollutants Like welding fumes, smoke and mist, grinding dust, foundry fumes, solvents, and vapoures.which are present in most industrial environments need to be eliminated by using source extractors, since these pollutants are toxic and hazardous to the workers and also affect the quality of the products. Kirloskar Fume Extractors and Oil Mist Collectors are the only effective solutions to these problems. They improve the working environment and reduce cost of general ventilation by spot exhaustion and cleaning.
These work on the principle of electrostatic precipitation

SPECIFICATION

Model

Fume Extractor

      Mist   
  Collector

Dimensions in mm.

550x980x1340

655x1260x850

Air Flow M³/HR

1700

1700

Input Voltage

415v

415v

Power Consumption Approx.

    1100 W

560 W

Weight (kg)

130

140

Cleaning Efficiency

Better than 90%

Better than 90%


View Complete Details

Laminar Flow Workstation

The design allows them to be used as individual units, or with side panels removed, which can be joined together for pass through assembly. Noise is minimized by designing a special type of air plenum. Vibrations are reduced to the work surface by mounting motor-blower assembly on springs

FEATURES
  • Well lit work surface
  • Low vibration and noise
  • Convenient service access
  • Easy to reassemble

CONSTRUCTION: - CRCA / SS
CABINET Cold rolled MS Sheets pre-treated & painted with stoving enamel.
SIDE PANELS Removable clear acryclic
WORK TABLE Wooden with melamine finish.
PREFILTERS HDPE Washable and Reusable. Throw away type also available.
HEPA FILTERS Filtration efficiency of 99.97 % for all particles of sizes 0.3 micron and larger.
MOTOR BLOWER Dynamically balanced and specially constructed to suit low noise and vibration.
LIGHTING Fluorescent tube lights with acrylic diffuser.
ELECTRIC SUPPLY INPUT 230 V AC,1 Phase ,50 Hz
TESTING Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class 100.

TYPES
DIMENSIONS
Model Work Space OVERALL Weight(Kg)
Width Height Depth Width Height Depth
KCH-A 600 580 600 730 1425 1050 130
KCH-B 1210 580 600 1340 1425 1050 200
KCH-C 1820 580 600 1950 1425 1050 270  
View Complete Details

PASS THROUGH BOX

Pass Box is installed at the interface of the clean and non-clean zones and is used for material movement.

TYPES:

1) Static Pass box. SIZE: - 650(W) X650 (D) X725 (H)2) Dynamics Pass box [with laminar flow air flow]3) SIZE: - 700(W) X700 (D) X1100 (H)
Overall Size (mm) 700(w) x 650(d) x 750(h)

Features
  • Wall Mounting type.
  • Door Interlocking system.
  • Audio-visual indication for door operations
Optional Accessories
  • U. V. Tube light
  • Stainless Steel bottom tray
OPTIONAL ITEM

The Pass Box can be provided with the following features:

  • Floor mounting for trolley movement
  • Custom sizes
  • Filtration system - Dynamic
View Complete Details

Fan Filter Unit

Fan Filter Unit(FFU) is air cleaning equipment to supply purified air to the clean room for manufacturing electronics components, food products, pharmaceuticals , health care or any precision engineering products .The installation space is the system ceiling grid. For a large clean room, a large number of FFU are required depending upon class of cleanliness.
View Complete Details

Fan Filter Units

Fan Filter Unit(FFU) is air cleaning equipment to supply purified air to the clean room for manufacturing electronics components, food products, pharmaceuticals , health care or any precision engineering products .The installation space is the system ceiling grid. For a large clean room, a large number of FFU are required depending upon class of cleanliness.

FEATURES
  • Modular Design to change layouts
  • Low Height & Weight.
  • Air Tight Performance
  • Low Noise & Vibration
  • Ductable Design
  • Cost optimization
  • HEPA and ULPA filters (Mostly minipleat) Choose either a HEPA Filter 99.99% eff. @ 0.3 micron or ULPA Filter 99.9995% eff. @ 0.12 Micron filters
  • Various optional accessories like prefilter Diffusion plate, pressure gauge
  • Group control management system
  • Fixed speed or variable speed control
  • Horizontal flow table unit
CONSTRUCTION:

Envair Fan Filter Units are self-contained, motorized Supply Air Modules equipped with either HEPA or ULPA filters. Envair FFU's can be used in either horizontal or vertical flow positions, wherever clean air is needed.They are designed for easy connection to the building power & Air Handelling system and are equipped with a pre-filter, four clips located at all corners for providing strong suspension points.Housings are fabricated from 18-gauge steel with a white powder coat finish or thermoformed plastic or GI or aluminum or stainless steel. Envair FFU are Tested as per Std. ISO ?14644 & US FED STD.209

View Complete Details

FILTRATION SYSTEMS IN HOSPITAL

  • Sterile Clean Air plays an important role during surgical procedure.
  • Sterile Clean Air has a dramatic effect in deep wounds.
  • In the Operating Room any kind of operation being performed should be under Sterile Air Environment. This sterile air environment protects the surgical open area from any kind of infection and also protect septic patient from effects of septic condition.
  • It reduces healing period hence reduces post operation curing period and dose of antibiotics.Hospital will have positive points for NABL Accredition

View Complete Details

Hydraulic Oil Cleaner

Clean Oil is necessary to get good performance from your machines/ equipments. Contaminations in oil are responsible for breakdown, losses and replacement of the oil.
Conventional methods of oil purification, viz: filtration, centrifuge and straining, are incapable of adequately cleaning oil, as they remove particles only above 5 microns in size.
These remaining small size particles cause high contamination and therefore require regular changing of oil.
Air breathers and cylinders effectively act as gates of entry to dust particles, which being only 2 microns in size, escape conventional oil purification methods.
The electrostatic cleaning presents a far superior and highly effective method of purifying hydraulic oil. Contaminants caused due to dust, abrasive metallic particles, oxidation, sludge and fine water are removed by this method. Oil cleaned by this method meets NAS class 4/5 requirements. (National Aerospace Standards 1638)
The KEOC 55, KEOC 110, APO-110 machines clean oil by electrostatic process, hence presence of moisture / water content in the oil affects the conductivity of the oil. These machines can clean oil with moisture / water content upto 500 ppm.
However if the moisture / water content in the oil exceeds 500 ppm then our models KEOC-110 DH & FDU 35 are useful. KEOC-110 DH can clean oil with a moisture content upto 1500 ppm.
If the moisture content exceeds 1500 ppm then the moisture has to be removed by FDU-35 (Flash Distillation Unit) then sent for electrostatic cleaning through KEOC-55 / KEOC-110

SOURCES OF CONTAMINATION OF OIL

The Hydraulic Oil in the system may get contaminated from any of the following sources. During manufacturing of components and assembly of systems, burr, chips, weld spatter, casting sand, particles from seals and gaskets, adhesives, paint particles etc. are left in the various components which go into the oil.
Many a times oil is contaminated by the time it arrives at the users end.
Air borne dust, dirt, rust, enter into the system and then into the oil through Air breathers, seals etc.
Metal particles that are produced by abrasive wear, erosion and surface fatigue in the system itself.
Contaminations due to surrounding atmosphere and leakages in the system.

View Complete Details

Laboratory Workstations

ENVAIR LAB WORKSTATIONS PROVIDE THE PERFECT BLEND OF ERGONOMICS, MODULARITY, DURABILITY, STRIKING GOOD LOOKS AND USER FRIENDLINESS.
THE ALUMINIUM EXTRUSION USED IN LAB WORKSTATION IS ROBUST, STABLE AND DISTORTION FREE. TWO MM THICK C FRAME IS PROVIDED BELOW THE TABLE TOP FOR STRAIGHTH AND FLATNESS. THIS STRUCTURE INCREASES THE UNIVERSAL LOAD BEARING CAPACITY UPTO 250-300 KG.COMPARED TO OTHERS PROVIDING UPTO 80-90 KG.
TABLE TOPS ARE AVAILABLE IN MDF, TELEPHONIC BLACK GRANITE , CHEMICAL RESISTANCE LAMINATE, MELAMINE LAMINATE, VETRIFIED TILES, STAINLESS STEEL & IMPORTED SYNTHETIC MARBLE LIKE CORIEN
ALL ADDON ACCESSORIES REQUIRED IN LAB WORKSTATIONS LIKE SINK, SECOND WORK LEVEL (REGENT RACKS) , BIN HOLDER, HOOK ON CONTAINER, EYE WASH SYSTEM ETC ARE AVAILABLE.ENVAIR LAB WORKSTATIONS HAVE CLEAN ROOM COMPATIBILITY DUE TO SELECTION OF PARTICLE NON SHEDDING MATERIALS



TECHNICAL SPECIFICATIONS

 

TABLE TOPS
(SIZES IN MM)

WIDTH 570,800,1140,1200,1600,1710
DEPTH - 670,800,870

DRAWER UNITS
PEDESTALS (1+3+6 OU)
(SIZES IN MM)

WIDTH -485
DEPTH 670,800,870 (LH/RH)

MOBILE DRAWER UNIT

WIDTH 485
DEPTH - 670,800,870

STORAGE CABINETS

WIDTH - 800,1200
DEPTH - 420,850 (TWIN TYPE)
HEIGHT 750,1700

   








SR.NO.

PART OF LAB WORKSTATIONS

ENVAIR MAKE

OTHERS

01

TABLE TOPS

IMPORTED COREAN TOPS
VETRIFIED TILES,
TELEPHONIC BLACK GRANITE
STAINLESS STEEL, 
MELAMINE LAMINATE

HAVE LIMITED CHOICES

02

LEGS

ALLUMINIUM EXTRUDED.
TOTAL UNIVERSAL LOAD BEARING CAPACITY OF ALLUMINIUM EXTRUDED LEGS ARE NEARLY 250-300 KG.
CORROSSION RESISTANT.

MS SQUARE PIPE ULD 80-90 KG.
CHANCES OF CORROSSION

03.

ELECTRICAL/DATA CABLE
BELT LINE

SEPARATE MODULAR ELECTRICAL BELT LINE WITH ALLUMINIUM FRONT PLATES, BEING MODULAR CAN BE FITTED AS PER REQUIREMENT EITHER ABOVE OR BELOW THE TABLE TOP AT THE TIME OF ASSEMBLY.

OTHERS ARE USING ONLY POWER STRIPS

04.

DRAWER UNITS

INDUSTRIAL SLIDES OR HEAVY DUTY INDUSTRIAL CHANNELS FOR DRAWER UNITS. UNIQUE CENTRAL LOCKING SYSTEM.

OTHERS MAY USE NON STANDARD CHANNELS.

05.

2 MM MS FRAME

PROVISION OF 2MM MS FRAME BELOW TABLE TOP FOR STRONG STRUCTURAL SUPPORT.

OTHERS MAY PROVIDE BUT WITH SPOT WELDING .

 

06.

MODULARITY

THE SYSTEM CAN EXTEND OR REDUCE HEIGHT AND LENGTH AS PER SITE REQUIREMENT.

IN WELDING SYSTEM THIS FACILITY IS NOT POSSIBLE

07

CLEAN ROOM COMPATABILITY

HAVING CLEAN ROOM COMPATIBILITY.

OTHERS DON’T HAVE DUE TO WELDING SYSTEM AND ROUGH SURFACES OF TABLE TOPS









View Complete Details

Air Curtain

Envair Air Curtains form invisible thermal as well as dust barriers between controlled and outside environments. They allow easy through fare of persons & material with minimum effect of outside air on controlled environments. Hence these are most suitable for clean Factories, Hospitals, Operation Theatres & such other applications. These reduce energy bills on air-conditioning, as losses from frequent door openings, are reduced.

CONSTRUCTION: -
CABINET Cold rolled MS Sheet, pretreated & painted with stoving enamel
MOTOR BLOWER Dynamically balanced & specially constructed for low noise & vibrations
LIGHTING Provision only for horizontal type
Electrical supply input 250 V AC, 1 phase, 50 Hz �?For Domestic Type 415 V AC, 3 phase, 50 Hz �?For Industrial & Heavy Duty Industrial Type
TESTING All units are thoroughly tested at works & meet the requirement of ISO 14644 standard generally
FEATURES
  • All steel construction
  • Low noise & vibration
  • Convenient service access
 
Options
  • Curtain operation interlocked with door opening
  • Also available in stainless steel body
  • Available in Bio-free type for high efficiency, Industrial type for higher heights of door.
  • Medium efficiency filteration available in horizontal Configuration
  • Lower Noise Models Available with Accoustic lining.

TYPE
Model KAC-3(D) KAC-4(D) KAC-5(D) KAC-6(D)
WIDTH(W) 900 1200 1500 1800
HEIGHT(H) 325 325 325 325
DEPT(D) 415 415 415 415
WEIGHT(KG) 33 41 52 58

 

View Complete Details

Air Purifier

LONGEVITY ELIMINATES CONTAMINATION
  • Pet Animals, Soft Toys and Human Micro Flora
  • Smoke of Cigarettes
  • Indoor Cleaning Of House
  • Pollen Grains
  • Outdoor Dusty Air from autos & debris
  • Contamination from Cough & Cold
  • Swine flue virus
BENEFITS PATIENTS WHO HAVE
  • Eye Irritation
  • Coughs And Colds
  • Headache And Fatigue
  • Pneumonia
  • Asthma
  • Cross Infection In Patients
  • Infection In Burn Patients

REMOVES ALERGY-AGGREVATING MICRO PARTICLES

Longevity is specialized product that removes Allergens from indoor environments Effectively and economically. Longevity Removes microscopic particles, viruses, Bacteria, smoke, fumes etc. It uses High Efficiency Particulate Air (HEPA) FILTERS and is particularly useful for asthma patients.

LONGEVITY HELPS AT HOME

The reduction of airborne allergens is particularly important for CAT and DOG Allergens. These allergens are extremely small (less than 2.5 (microns) and stay airborne for hours. At the opposite end of the spectrum, dust mite, allergens (5-50 microns) settle much Quicker and are re-launched into the air by various household activitiesLongevity contains a uniquely formulated Gas and Odor Filter media. Odors from pets, cooking, tobacco, even paint fumes, disappear without significantly reducing the airflow rate. The unit has the capability to absorb high molecular weight such as Volatile Organic Compounds (VOCs) like benzene, toluene and xylene AND for low molecular weight such as formaldehyde and hydrogen sulfide. It removes tobacco smoke from the air to improve Indoor Air Quality (IAQ). This is a useful product for

APPLICATION
  • HOMES
  • OFFICES
  • RESTAURANTS
  • BARS
  • DOCTORS
  • CONSULTING ROOMS
  • HOSPITALS
  • SEMICLEAN ROOMS
View Complete Details

HEPA Filter

  • Pressure Drop 25mm WG for 100% rated flow

CONSTRUCTION

Filtering Media

Micro glass fiber filter paper, pleated with Aluminium spacers used for separating consecutive pleats.

Frame

GI Powder Coated / Al. Anodized / Wood.

Adhesive

Epoxy based adhesive is used for leak proof joint Between filter paper & frame

Gaskets

Sponge rubber gaskets are provided for sealing of filter on its mounting frame

PERFORMANCE

Recommended for operating efficiency of 99.97% down to particle size of 0.3 micron by DOP (Di-Octyl-Pthalate) test as per STD ISO 14644.

OPERATING CONDITIONS

Ambient temperature (max. 50 degree C) and Humidity up to 100% RH

View Complete Details

Electrostatic Cleaner

In any working environment, particularly in commercial 7 industrial establishments, computer facilities, telephone exchanges, precision shops, suspended particulate matter like dust, pollen, smoke needs to be eliminated to ensure high quality performance by both men and machines. ENVAIR Electrostatic Air Cleaner is an ultimate effective solution to this problem as it provides clean air for all applications by recycling interior air, while saving energy costs. It purifies air efficiently without exhausting heated or cooled air. In a typical Application like currency chests in banks, no other conventional air cleaner can be effective than envair electrostatic cleaner to remove contamination from superfine dust on hates. Electrostatic Air Cleaner work on the principle of electrostatic precipitation.

SAILENT FEATURES
CONSTRUCTION The unit is sturdy, being made of CRCA sheet metal, welded and finished in stoving enamel paint for long life.
Maintenance Negligible �?The Aluminium stack is simply removed washed and is put back in position as are the fabric filters.
Safe Operation The unit has dual protection system. When dust layers become thicker, the efficiency drops. The protection system operates, preventing damage to power pack and stack. It also gives indication as to when stack should be cleaned. The unit trips when back door is opened for maintenance
Versatile The unit can work independently in a room or along with centralized air conditioning system. Ceiling suspended units are offered for various applications, which include pharmaceutical industries, restaurants and cinema halls.
Low Power consumption Unit draws 230 VAC single phase 50 Hz power, so no special input provision is required.
Silent Operation Dynamically balanced motor and blower assembly reduces both noise and vibration of the unit.
Operating system Airborne particles are filtered off in three stages
  1. In the first stage, particles are drawn in the unit and are passed through a pre-filter made of High Density Poly Ethelene.Large particles of size 15 microns to 20 microns are filtered here.
  2. The particles are given a positive high voltage of 12 kV with the help of an ionizer and in- built power pack. These charged particles are passed through the stack assembly consisting of a series of Aluminium plates fixed at a close distance, alternately carrying positive and ground potential. The positively charged particles while traveling through the stack get repelled by the positively charged plates and are deposited on plates having zero potential and are separated from air.
  3. In the last stage a post filter is used to achieve uniform flow. Thus dust precipitation level up to 0.1 micron particulate size can be achieved and clean air is released for recirculation.
Optional- Cleaning or Washing Arrangement Semi or fully automatic washing arrangement dry or wet can be provided With self contained water tank, detergent, heater, and timer and waste tank. For dry dust, the cleaning is possible by just conventional air blower or rapping.
TESTING Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class �?100.

 

SPECIFICATIONS
Model KEA-15 KEA-30
Overall Dimensions(mm) 550*500*1160 850*500*1160
Weight (Kgs)Approx 90 120
Air Handling Capacity 15 m3/min 30 m3/min
Power Consumption(W)approx =100W =200W
Input Voltage 230VAC,50Hz,1Ph
Filteration efficiency Average efficency 70-85%ASHRAE 52-76 dust spot method
Construction M.S.;CRCA Stove Enameled Painted
Stack Assembly Aluminium treated for better efficiency

 

View Complete Details

Hydraulic Oil Cleaning Machine

Clean Oil is necessary to get good performance from your machines equipments. Contaminations in oil are responsible for breakdown, losses and replacement of the oil. Conventional methods of oil purification, viz: filtration, centrifuge and straining, are incapable of adequately cleaning oil, as they remove particles only above 5 microns in size. These remaining small size particles cause high contamination and therefore require regular changing of oil. The electrostatic cleaning presents a far superior and highly effective method of purifying hydraulic oil. Contaminants caused due to dust, abrasive metallic particles, oxidation, sludge and fine water are removed by this method. Oil cleaned by this method meets NAS class 45 requirements. (National Aerospace Standards 1638)
View Complete Details

Air Shower

ENVAIR Air Showers are fully automatic, electrically operated units, that give personnel a high velocity clean air wash, before they enter controlled clean-air environments. Air interlock system prevents contaminants from entering clean rooms, by containing them in the Air Shower itself.
Versatile ENVAIR Air Showers possess a modular joinable design. This permits single or tunnel constructions, to perfectly meet the needs of small to large users. Different sizes and flexible models of entry and exit, afford both economy of space and compatibility with user environments
Every ENVAIR Air Shower is thoroughly factory tested for high efficiency. Corrosion resistant pre-treated stove enameled, MS Sheets are used to ensure manufacturing quality that is built to last.

View Complete Details

Bio Safety Cabinet

Bio safety cabinate Compact in design

FEATURES
  • Well-lit work surface
  • Low vibration and noise.
  • Convenient service access.
  • Easy to reassemble
  • Adjustable motor blower speed.
  • Gas cock assembly.
  • Stainless Steel work surface
  • Sink
  • Ultra-violet tube light
  • Exhaust duct in PVC.
  • Virus burner
  • Speed Regulator for Blower
ADDITIONAL FEATURES
  • Slant Design for better Aesthetes & Visibility
  • Front Side Maintenance access for Filters, Blower & Electrical Components
  • All Audio Visual Alarm for Excessive Shutter Opening.
  • Interlocking Provision of U/V Tube Light with Fluorescent Tube Light & Shutter.
  • U/V Tube Light Hour Meter.
  • Digital Display for supply Velocity & Exhaust Velocity.
  • Automatic Blower Speed Control w.r.t. Supply Air Velocity.
INBUILT ACCESSARIES
  • Stainless Steel Table Top
  • Sliding Front Shutter
  • Sink and Drainpipe
  • Supply and Exhaust
  • Manometer Damper
  • Air / Gas / Vacuum Cock

CONSTRUCTION: -
CABINET Cold rolled MS sheets pre �Ctreated &painted with stoving enamel. Alternate stainless steel 304 mat finishes.S.S. Table with mat finish.
HEPA FILTERS  Filtration efficiency of 99.99% for particles of sizes up to 0.3 micron
MOTOR BLOWER Dynamically balanced and specially constructed to suit low noise and vibration
LIGHTING Fluorescent tube light with acrylic diffuser
ELECTRIC SUPPLY UNIT 230 AC, 1 Phase, 50 Hz
TESTING Each unit is thoroughly tested at our works and exceeds requirements of NSF-49 Std.

TYPE
DIMENSIONS
Model Overall Dimensions Working Dimension
W*D*Ht(mm) W*D*Ht(mm)
KCV-B-BIO-IIA 1410*900*1990 1210*650*600
KCV-M-BIO-IIA 1025*900*1990 885*650*600
KCV-C-BIO-IIA 2020*900*1990 1820*650*600
KCV-B-BIO-IIB 1400*1250*2075 1220*600*500
KCV-C-BIO-IIB 2050*1250*2075 1830*600*500

 

View Complete Details

Oil Cleaning System

To keep system Hydraulic Oil in superfine condition by removing contamination, like dirt, dust, sludge, and metallic particle. Since conventional system of Purification like centrifuge mechanical filtration has limitations and cannot remove particles below 5 microns, cost effectively.If system hydraulic oil is maintained in super clean condition 80 to 85% problems on hydraulic equipment are prevented. In turn it enhances life of the equipment and its accessories such as pump, valve etc. saves on oil replacement cost etc.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by envair electrodyne ltd. from Pune, Maharashtra.
Post Buy Requirement

Our Products

  1. Modular Office Workstation 3 Products available
  2. Filters & Filtration Systems 3 Products available
  3. Oil Extraction Machine

    2 Products available
  4. Clean Room Equipment

    2 Products available
  5. Automotive Cleaners

    1 Products available
  6. Filters

    1 Products available
  7. Industrial Scrubbers

    1 Products available
  8. Safety System & Equipments

    1 Products available
  9. Curtains

    1 Products available
  10. Air Purifiers

    1 Products available
  11. Others Products 1 Products available

Our Products

We offer a complete product range of Electrostatic Cleaner

Laminar Flow Workstations

  • Feature Well lit work surface Low vibration and noise Convenient service access Easy to reassemble
The design allows them to be used as individual units, or with side panels removed, which can be joined together for pass through assembly. Noise is minimized by designing a special type of air plenum. Vibrations are reduced to the work surface by mounting motor-blower assembly on springs
View Complete Details

FUME EXTRACTOR AND OIL MIST COLLECTER

Pollutants Like welding fumes, smoke and mist, grinding dust, foundry fumes, solvents, and vapoures.which are present in most industrial environments need to be eliminated by using source extractors, since these pollutants are toxic and hazardous to the workers and also affect the quality of the products. Kirloskar Fume Extractors and Oil Mist Collectors are the only effective solutions to these problems. They improve the working environment and reduce cost of general ventilation by spot exhaustion and cleaning.
These work on the principle of electrostatic precipitation

SPECIFICATION

Model

Fume Extractor

      Mist   
  Collector

Dimensions in mm.

550x980x1340

655x1260x850

Air Flow M³/HR

1700

1700

Input Voltage

415v

415v

Power Consumption Approx.

    1100 W

560 W

Weight (kg)

130

140

Cleaning Efficiency

Better than 90%

Better than 90%


View Complete Details

Laminar Flow Workstation

The design allows them to be used as individual units, or with side panels removed, which can be joined together for pass through assembly. Noise is minimized by designing a special type of air plenum. Vibrations are reduced to the work surface by mounting motor-blower assembly on springs

FEATURES
  • Well lit work surface
  • Low vibration and noise
  • Convenient service access
  • Easy to reassemble

CONSTRUCTION: - CRCA / SS
CABINET Cold rolled MS Sheets pre-treated & painted with stoving enamel.
SIDE PANELS Removable clear acryclic
WORK TABLE Wooden with melamine finish.
PREFILTERS HDPE Washable and Reusable. Throw away type also available.
HEPA FILTERS Filtration efficiency of 99.97 % for all particles of sizes 0.3 micron and larger.
MOTOR BLOWER Dynamically balanced and specially constructed to suit low noise and vibration.
LIGHTING Fluorescent tube lights with acrylic diffuser.
ELECTRIC SUPPLY INPUT 230 V AC,1 Phase ,50 Hz
TESTING Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class 100.

TYPES
DIMENSIONS
Model Work Space OVERALL Weight(Kg)
Width Height Depth Width Height Depth
KCH-A 600 580 600 730 1425 1050 130
KCH-B 1210 580 600 1340 1425 1050 200
KCH-C 1820 580 600 1950 1425 1050 270  
View Complete Details

PASS THROUGH BOX

Pass Box is installed at the interface of the clean and non-clean zones and is used for material movement.

TYPES:

1) Static Pass box. SIZE: - 650(W) X650 (D) X725 (H)2) Dynamics Pass box [with laminar flow air flow]3) SIZE: - 700(W) X700 (D) X1100 (H)
Overall Size (mm) 700(w) x 650(d) x 750(h)

Features
  • Wall Mounting type.
  • Door Interlocking system.
  • Audio-visual indication for door operations
Optional Accessories
  • U. V. Tube light
  • Stainless Steel bottom tray
OPTIONAL ITEM

The Pass Box can be provided with the following features:

  • Floor mounting for trolley movement
  • Custom sizes
  • Filtration system - Dynamic
View Complete Details

Fan Filter Unit

Fan Filter Unit(FFU) is air cleaning equipment to supply purified air to the clean room for manufacturing electronics components, food products, pharmaceuticals , health care or any precision engineering products .The installation space is the system ceiling grid. For a large clean room, a large number of FFU are required depending upon class of cleanliness.
View Complete Details

Fan Filter Units

Fan Filter Unit(FFU) is air cleaning equipment to supply purified air to the clean room for manufacturing electronics components, food products, pharmaceuticals , health care or any precision engineering products .The installation space is the system ceiling grid. For a large clean room, a large number of FFU are required depending upon class of cleanliness.

FEATURES
  • Modular Design to change layouts
  • Low Height & Weight.
  • Air Tight Performance
  • Low Noise & Vibration
  • Ductable Design
  • Cost optimization
  • HEPA and ULPA filters (Mostly minipleat) Choose either a HEPA Filter 99.99% eff. @ 0.3 micron or ULPA Filter 99.9995% eff. @ 0.12 Micron filters
  • Various optional accessories like prefilter Diffusion plate, pressure gauge
  • Group control management system
  • Fixed speed or variable speed control
  • Horizontal flow table unit
CONSTRUCTION:

Envair Fan Filter Units are self-contained, motorized Supply Air Modules equipped with either HEPA or ULPA filters. Envair FFU's can be used in either horizontal or vertical flow positions, wherever clean air is needed.They are designed for easy connection to the building power & Air Handelling system and are equipped with a pre-filter, four clips located at all corners for providing strong suspension points.Housings are fabricated from 18-gauge steel with a white powder coat finish or thermoformed plastic or GI or aluminum or stainless steel. Envair FFU are Tested as per Std. ISO ?14644 & US FED STD.209

View Complete Details

FILTRATION SYSTEMS IN HOSPITAL

  • Sterile Clean Air plays an important role during surgical procedure.
  • Sterile Clean Air has a dramatic effect in deep wounds.
  • In the Operating Room any kind of operation being performed should be under Sterile Air Environment. This sterile air environment protects the surgical open area from any kind of infection and also protect septic patient from effects of septic condition.
  • It reduces healing period hence reduces post operation curing period and dose of antibiotics.Hospital will have positive points for NABL Accredition

View Complete Details

Hydraulic Oil Cleaner

Clean Oil is necessary to get good performance from your machines/ equipments. Contaminations in oil are responsible for breakdown, losses and replacement of the oil.
Conventional methods of oil purification, viz: filtration, centrifuge and straining, are incapable of adequately cleaning oil, as they remove particles only above 5 microns in size.
These remaining small size particles cause high contamination and therefore require regular changing of oil.
Air breathers and cylinders effectively act as gates of entry to dust particles, which being only 2 microns in size, escape conventional oil purification methods.
The electrostatic cleaning presents a far superior and highly effective method of purifying hydraulic oil. Contaminants caused due to dust, abrasive metallic particles, oxidation, sludge and fine water are removed by this method. Oil cleaned by this method meets NAS class 4/5 requirements. (National Aerospace Standards 1638)
The KEOC 55, KEOC 110, APO-110 machines clean oil by electrostatic process, hence presence of moisture / water content in the oil affects the conductivity of the oil. These machines can clean oil with moisture / water content upto 500 ppm.
However if the moisture / water content in the oil exceeds 500 ppm then our models KEOC-110 DH & FDU 35 are useful. KEOC-110 DH can clean oil with a moisture content upto 1500 ppm.
If the moisture content exceeds 1500 ppm then the moisture has to be removed by FDU-35 (Flash Distillation Unit) then sent for electrostatic cleaning through KEOC-55 / KEOC-110

SOURCES OF CONTAMINATION OF OIL

The Hydraulic Oil in the system may get contaminated from any of the following sources. During manufacturing of components and assembly of systems, burr, chips, weld spatter, casting sand, particles from seals and gaskets, adhesives, paint particles etc. are left in the various components which go into the oil.
Many a times oil is contaminated by the time it arrives at the users end.
Air borne dust, dirt, rust, enter into the system and then into the oil through Air breathers, seals etc.
Metal particles that are produced by abrasive wear, erosion and surface fatigue in the system itself.
Contaminations due to surrounding atmosphere and leakages in the system.

View Complete Details

Laboratory Workstations

ENVAIR LAB WORKSTATIONS PROVIDE THE PERFECT BLEND OF ERGONOMICS, MODULARITY, DURABILITY, STRIKING GOOD LOOKS AND USER FRIENDLINESS.
THE ALUMINIUM EXTRUSION USED IN LAB WORKSTATION IS ROBUST, STABLE AND DISTORTION FREE. TWO MM THICK C FRAME IS PROVIDED BELOW THE TABLE TOP FOR STRAIGHTH AND FLATNESS. THIS STRUCTURE INCREASES THE UNIVERSAL LOAD BEARING CAPACITY UPTO 250-300 KG.COMPARED TO OTHERS PROVIDING UPTO 80-90 KG.
TABLE TOPS ARE AVAILABLE IN MDF, TELEPHONIC BLACK GRANITE , CHEMICAL RESISTANCE LAMINATE, MELAMINE LAMINATE, VETRIFIED TILES, STAINLESS STEEL & IMPORTED SYNTHETIC MARBLE LIKE CORIEN
ALL ADDON ACCESSORIES REQUIRED IN LAB WORKSTATIONS LIKE SINK, SECOND WORK LEVEL (REGENT RACKS) , BIN HOLDER, HOOK ON CONTAINER, EYE WASH SYSTEM ETC ARE AVAILABLE.ENVAIR LAB WORKSTATIONS HAVE CLEAN ROOM COMPATIBILITY DUE TO SELECTION OF PARTICLE NON SHEDDING MATERIALS



TECHNICAL SPECIFICATIONS

 

TABLE TOPS
(SIZES IN MM)

WIDTH 570,800,1140,1200,1600,1710
DEPTH - 670,800,870

DRAWER UNITS
PEDESTALS (1+3+6 OU)
(SIZES IN MM)

WIDTH -485
DEPTH 670,800,870 (LH/RH)

MOBILE DRAWER UNIT

WIDTH 485
DEPTH - 670,800,870

STORAGE CABINETS

WIDTH - 800,1200
DEPTH - 420,850 (TWIN TYPE)
HEIGHT 750,1700

   








SR.NO.

PART OF LAB WORKSTATIONS

ENVAIR MAKE

OTHERS

01

TABLE TOPS

IMPORTED COREAN TOPS
VETRIFIED TILES,
TELEPHONIC BLACK GRANITE
STAINLESS STEEL, 
MELAMINE LAMINATE

HAVE LIMITED CHOICES

02

LEGS

ALLUMINIUM EXTRUDED.
TOTAL UNIVERSAL LOAD BEARING CAPACITY OF ALLUMINIUM EXTRUDED LEGS ARE NEARLY 250-300 KG.
CORROSSION RESISTANT.

MS SQUARE PIPE ULD 80-90 KG.
CHANCES OF CORROSSION

03.

ELECTRICAL/DATA CABLE
BELT LINE

SEPARATE MODULAR ELECTRICAL BELT LINE WITH ALLUMINIUM FRONT PLATES, BEING MODULAR CAN BE FITTED AS PER REQUIREMENT EITHER ABOVE OR BELOW THE TABLE TOP AT THE TIME OF ASSEMBLY.

OTHERS ARE USING ONLY POWER STRIPS

04.

DRAWER UNITS

INDUSTRIAL SLIDES OR HEAVY DUTY INDUSTRIAL CHANNELS FOR DRAWER UNITS. UNIQUE CENTRAL LOCKING SYSTEM.

OTHERS MAY USE NON STANDARD CHANNELS.

05.

2 MM MS FRAME

PROVISION OF 2MM MS FRAME BELOW TABLE TOP FOR STRONG STRUCTURAL SUPPORT.

OTHERS MAY PROVIDE BUT WITH SPOT WELDING .

 

06.

MODULARITY

THE SYSTEM CAN EXTEND OR REDUCE HEIGHT AND LENGTH AS PER SITE REQUIREMENT.

IN WELDING SYSTEM THIS FACILITY IS NOT POSSIBLE

07

CLEAN ROOM COMPATABILITY

HAVING CLEAN ROOM COMPATIBILITY.

OTHERS DON’T HAVE DUE TO WELDING SYSTEM AND ROUGH SURFACES OF TABLE TOPS









View Complete Details

Air Curtain

Envair Air Curtains form invisible thermal as well as dust barriers between controlled and outside environments. They allow easy through fare of persons & material with minimum effect of outside air on controlled environments. Hence these are most suitable for clean Factories, Hospitals, Operation Theatres & such other applications. These reduce energy bills on air-conditioning, as losses from frequent door openings, are reduced.

CONSTRUCTION: -
CABINET Cold rolled MS Sheet, pretreated & painted with stoving enamel
MOTOR BLOWER Dynamically balanced & specially constructed for low noise & vibrations
LIGHTING Provision only for horizontal type
Electrical supply input 250 V AC, 1 phase, 50 Hz �?For Domestic Type 415 V AC, 3 phase, 50 Hz �?For Industrial & Heavy Duty Industrial Type
TESTING All units are thoroughly tested at works & meet the requirement of ISO 14644 standard generally
FEATURES
  • All steel construction
  • Low noise & vibration
  • Convenient service access
 
Options
  • Curtain operation interlocked with door opening
  • Also available in stainless steel body
  • Available in Bio-free type for high efficiency, Industrial type for higher heights of door.
  • Medium efficiency filteration available in horizontal Configuration
  • Lower Noise Models Available with Accoustic lining.

TYPE
Model KAC-3(D) KAC-4(D) KAC-5(D) KAC-6(D)
WIDTH(W) 900 1200 1500 1800
HEIGHT(H) 325 325 325 325
DEPT(D) 415 415 415 415
WEIGHT(KG) 33 41 52 58

 

View Complete Details

Air Purifier

LONGEVITY ELIMINATES CONTAMINATION
  • Pet Animals, Soft Toys and Human Micro Flora
  • Smoke of Cigarettes
  • Indoor Cleaning Of House
  • Pollen Grains
  • Outdoor Dusty Air from autos & debris
  • Contamination from Cough & Cold
  • Swine flue virus
BENEFITS PATIENTS WHO HAVE
  • Eye Irritation
  • Coughs And Colds
  • Headache And Fatigue
  • Pneumonia
  • Asthma
  • Cross Infection In Patients
  • Infection In Burn Patients

REMOVES ALERGY-AGGREVATING MICRO PARTICLES

Longevity is specialized product that removes Allergens from indoor environments Effectively and economically. Longevity Removes microscopic particles, viruses, Bacteria, smoke, fumes etc. It uses High Efficiency Particulate Air (HEPA) FILTERS and is particularly useful for asthma patients.

LONGEVITY HELPS AT HOME

The reduction of airborne allergens is particularly important for CAT and DOG Allergens. These allergens are extremely small (less than 2.5 (microns) and stay airborne for hours. At the opposite end of the spectrum, dust mite, allergens (5-50 microns) settle much Quicker and are re-launched into the air by various household activitiesLongevity contains a uniquely formulated Gas and Odor Filter media. Odors from pets, cooking, tobacco, even paint fumes, disappear without significantly reducing the airflow rate. The unit has the capability to absorb high molecular weight such as Volatile Organic Compounds (VOCs) like benzene, toluene and xylene AND for low molecular weight such as formaldehyde and hydrogen sulfide. It removes tobacco smoke from the air to improve Indoor Air Quality (IAQ). This is a useful product for

APPLICATION
  • HOMES
  • OFFICES
  • RESTAURANTS
  • BARS
  • DOCTORS
  • CONSULTING ROOMS
  • HOSPITALS
  • SEMICLEAN ROOMS
View Complete Details

HEPA Filter

  • Pressure Drop 25mm WG for 100% rated flow

CONSTRUCTION

Filtering Media

Micro glass fiber filter paper, pleated with Aluminium spacers used for separating consecutive pleats.

Frame

GI Powder Coated / Al. Anodized / Wood.

Adhesive

Epoxy based adhesive is used for leak proof joint Between filter paper & frame

Gaskets

Sponge rubber gaskets are provided for sealing of filter on its mounting frame

PERFORMANCE

Recommended for operating efficiency of 99.97% down to particle size of 0.3 micron by DOP (Di-Octyl-Pthalate) test as per STD ISO 14644.

OPERATING CONDITIONS

Ambient temperature (max. 50 degree C) and Humidity up to 100% RH

View Complete Details

Electrostatic Cleaner

In any working environment, particularly in commercial 7 industrial establishments, computer facilities, telephone exchanges, precision shops, suspended particulate matter like dust, pollen, smoke needs to be eliminated to ensure high quality performance by both men and machines. ENVAIR Electrostatic Air Cleaner is an ultimate effective solution to this problem as it provides clean air for all applications by recycling interior air, while saving energy costs. It purifies air efficiently without exhausting heated or cooled air. In a typical Application like currency chests in banks, no other conventional air cleaner can be effective than envair electrostatic cleaner to remove contamination from superfine dust on hates. Electrostatic Air Cleaner work on the principle of electrostatic precipitation.

SAILENT FEATURES
CONSTRUCTION The unit is sturdy, being made of CRCA sheet metal, welded and finished in stoving enamel paint for long life.
Maintenance Negligible �?The Aluminium stack is simply removed washed and is put back in position as are the fabric filters.
Safe Operation The unit has dual protection system. When dust layers become thicker, the efficiency drops. The protection system operates, preventing damage to power pack and stack. It also gives indication as to when stack should be cleaned. The unit trips when back door is opened for maintenance
Versatile The unit can work independently in a room or along with centralized air conditioning system. Ceiling suspended units are offered for various applications, which include pharmaceutical industries, restaurants and cinema halls.
Low Power consumption Unit draws 230 VAC single phase 50 Hz power, so no special input provision is required.
Silent Operation Dynamically balanced motor and blower assembly reduces both noise and vibration of the unit.
Operating system Airborne particles are filtered off in three stages
  1. In the first stage, particles are drawn in the unit and are passed through a pre-filter made of High Density Poly Ethelene.Large particles of size 15 microns to 20 microns are filtered here.
  2. The particles are given a positive high voltage of 12 kV with the help of an ionizer and in- built power pack. These charged particles are passed through the stack assembly consisting of a series of Aluminium plates fixed at a close distance, alternately carrying positive and ground potential. The positively charged particles while traveling through the stack get repelled by the positively charged plates and are deposited on plates having zero potential and are separated from air.
  3. In the last stage a post filter is used to achieve uniform flow. Thus dust precipitation level up to 0.1 micron particulate size can be achieved and clean air is released for recirculation.
Optional- Cleaning or Washing Arrangement Semi or fully automatic washing arrangement dry or wet can be provided With self contained water tank, detergent, heater, and timer and waste tank. For dry dust, the cleaning is possible by just conventional air blower or rapping.
TESTING Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class �?100.

 

SPECIFICATIONS
Model KEA-15 KEA-30
Overall Dimensions(mm) 550*500*1160 850*500*1160
Weight (Kgs)Approx 90 120
Air Handling Capacity 15 m3/min 30 m3/min
Power Consumption(W)approx =100W =200W
Input Voltage 230VAC,50Hz,1Ph
Filteration efficiency Average efficency 70-85%ASHRAE 52-76 dust spot method
Construction M.S.;CRCA Stove Enameled Painted
Stack Assembly Aluminium treated for better efficiency

 

View Complete Details

Hydraulic Oil Cleaning Machine

Clean Oil is necessary to get good performance from your machines equipments. Contaminations in oil are responsible for breakdown, losses and replacement of the oil. Conventional methods of oil purification, viz: filtration, centrifuge and straining, are incapable of adequately cleaning oil, as they remove particles only above 5 microns in size. These remaining small size particles cause high contamination and therefore require regular changing of oil. The electrostatic cleaning presents a far superior and highly effective method of purifying hydraulic oil. Contaminants caused due to dust, abrasive metallic particles, oxidation, sludge and fine water are removed by this method. Oil cleaned by this method meets NAS class 45 requirements. (National Aerospace Standards 1638)
View Complete Details

Air Shower

ENVAIR Air Showers are fully automatic, electrically operated units, that give personnel a high velocity clean air wash, before they enter controlled clean-air environments. Air interlock system prevents contaminants from entering clean rooms, by containing them in the Air Shower itself.
Versatile ENVAIR Air Showers possess a modular joinable design. This permits single or tunnel constructions, to perfectly meet the needs of small to large users. Different sizes and flexible models of entry and exit, afford both economy of space and compatibility with user environments
Every ENVAIR Air Shower is thoroughly factory tested for high efficiency. Corrosion resistant pre-treated stove enameled, MS Sheets are used to ensure manufacturing quality that is built to last.

View Complete Details

Bio Safety Cabinet

Bio safety cabinate Compact in design

FEATURES
  • Well-lit work surface
  • Low vibration and noise.
  • Convenient service access.
  • Easy to reassemble
  • Adjustable motor blower speed.
  • Gas cock assembly.
  • Stainless Steel work surface
  • Sink
  • Ultra-violet tube light
  • Exhaust duct in PVC.
  • Virus burner
  • Speed Regulator for Blower
ADDITIONAL FEATURES
  • Slant Design for better Aesthetes & Visibility
  • Front Side Maintenance access for Filters, Blower & Electrical Components
  • All Audio Visual Alarm for Excessive Shutter Opening.
  • Interlocking Provision of U/V Tube Light with Fluorescent Tube Light & Shutter.
  • U/V Tube Light Hour Meter.
  • Digital Display for supply Velocity & Exhaust Velocity.
  • Automatic Blower Speed Control w.r.t. Supply Air Velocity.
INBUILT ACCESSARIES
  • Stainless Steel Table Top
  • Sliding Front Shutter
  • Sink and Drainpipe
  • Supply and Exhaust
  • Manometer Damper
  • Air / Gas / Vacuum Cock

CONSTRUCTION: -
CABINET Cold rolled MS sheets pre �Ctreated &painted with stoving enamel. Alternate stainless steel 304 mat finishes.S.S. Table with mat finish.
HEPA FILTERS  Filtration efficiency of 99.99% for particles of sizes up to 0.3 micron
MOTOR BLOWER Dynamically balanced and specially constructed to suit low noise and vibration
LIGHTING Fluorescent tube light with acrylic diffuser
ELECTRIC SUPPLY UNIT 230 AC, 1 Phase, 50 Hz
TESTING Each unit is thoroughly tested at our works and exceeds requirements of NSF-49 Std.

TYPE
DIMENSIONS
Model Overall Dimensions Working Dimension
W*D*Ht(mm) W*D*Ht(mm)
KCV-B-BIO-IIA 1410*900*1990 1210*650*600
KCV-M-BIO-IIA 1025*900*1990 885*650*600
KCV-C-BIO-IIA 2020*900*1990 1820*650*600
KCV-B-BIO-IIB 1400*1250*2075 1220*600*500
KCV-C-BIO-IIB 2050*1250*2075 1830*600*500

 

View Complete Details

Oil Cleaning System

To keep system Hydraulic Oil in superfine condition by removing contamination, like dirt, dust, sludge, and metallic particle. Since conventional system of Purification like centrifuge mechanical filtration has limitations and cannot remove particles below 5 microns, cost effectively.If system hydraulic oil is maintained in super clean condition 80 to 85% problems on hydraulic equipment are prevented. In turn it enhances life of the equipment and its accessories such as pump, valve etc. saves on oil replacement cost etc.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us