Our Products
Clean Room Equipment
2 Products availableOil Extraction Machine
2 Products availableAutomotive Cleaners
1 Products availableFilters
1 Products availableIndustrial Scrubbers
1 Products availableSafety System & Equipments
1 Products availableCurtains
1 Products availableAir Purifiers
1 Products availableWe offer a complete product range of Electrostatic Cleaner
Pollutants Like welding fumes, smoke and mist, grinding dust, foundry fumes, solvents, and vapoures.which are present in most industrial environments need to be eliminated by using source extractors, since these pollutants are toxic and hazardous to the workers and also affect the quality of the products. Kirloskar Fume Extractors and Oil Mist Collectors are the only effective solutions to these problems. They improve the working environment and reduce cost of general ventilation by spot exhaustion and cleaning.
These work on the principle of electrostatic precipitation
Model |
Fume Extractor |
Mist |
---|---|---|
Dimensions in mm. |
550x980x1340 |
655x1260x850 |
Air Flow M³/HR |
1700 |
1700 |
Input Voltage |
415v |
415v |
Power Consumption Approx. |
1100 W |
560 W |
Weight (kg) |
130 |
140 |
Cleaning Efficiency |
Better than 90% |
Better than 90% |
The design allows them to be used as individual units, or with side panels removed, which can be joined together for pass through assembly. Noise is minimized by designing a special type of air plenum. Vibrations are reduced to the work surface by mounting motor-blower assembly on springs
CABINET | Cold rolled MS Sheets pre-treated & painted with stoving enamel. |
SIDE PANELS | Removable clear acryclic |
WORK TABLE | Wooden with melamine finish. |
PREFILTERS | HDPE Washable and Reusable. Throw away type also available. |
HEPA FILTERS | Filtration efficiency of 99.97 % for all particles of sizes 0.3 micron and larger. |
MOTOR BLOWER | Dynamically balanced and specially constructed to suit low noise and vibration. |
LIGHTING | Fluorescent tube lights with acrylic diffuser. |
ELECTRIC SUPPLY INPUT | 230 V AC,1 Phase ,50 Hz |
TESTING | Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class 100. |
DIMENSIONS | |||||||
---|---|---|---|---|---|---|---|
Model | Work Space | OVERALL | Weight(Kg) | ||||
Width | Height | Depth | Width | Height | Depth | ||
KCH-A | 600 | 580 | 600 | 730 | 1425 | 1050 | 130 |
KCH-B | 1210 | 580 | 600 | 1340 | 1425 | 1050 | 200 |
KCH-C | 1820 | 580 | 600 | 1950 | 1425 | 1050 | 270 |
Pass Box is installed at the interface of the clean and non-clean zones and is used for material movement.
TYPES:1) Static Pass box. SIZE: - 650(W) X650 (D) X725 (H)2) Dynamics Pass box [with laminar flow air flow]3) SIZE: - 700(W) X700 (D) X1100 (H)
Overall Size (mm) 700(w) x 650(d) x 750(h)
The Pass Box can be provided with the following features:
Fan Filter Unit(FFU) is air cleaning equipment to supply purified air to the clean room for manufacturing electronics components, food products, pharmaceuticals , health care or any precision engineering products .The installation space is the system ceiling grid. For a large clean room, a large number of FFU are required depending upon class of cleanliness.
Envair Fan Filter Units are self-contained, motorized Supply Air Modules equipped with either HEPA or ULPA filters. Envair FFU's can be used in either horizontal or vertical flow positions, wherever clean air is needed.They are designed for easy connection to the building power & Air Handelling system and are equipped with a pre-filter, four clips located at all corners for providing strong suspension points.Housings are fabricated from 18-gauge steel with a white powder coat finish or thermoformed plastic or GI or aluminum or stainless steel. Envair FFU are Tested as per Std. ISO ?14644 & US FED STD.209
Clean Oil is necessary to get good performance from your machines/ equipments. Contaminations in oil are responsible for breakdown, losses and replacement of the oil.
Conventional methods of oil purification, viz: filtration, centrifuge and straining, are incapable of adequately cleaning oil, as they remove particles only above 5 microns in size.
These remaining small size particles cause high contamination and therefore require regular changing of oil.
Air breathers and cylinders effectively act as gates of entry to dust particles, which being only 2 microns in size, escape conventional oil purification methods.
The electrostatic cleaning presents a far superior and highly effective method of purifying hydraulic oil. Contaminants caused due to dust, abrasive metallic particles, oxidation, sludge and fine water are removed by this method. Oil cleaned by this method meets NAS class 4/5 requirements. (National Aerospace Standards 1638)
The KEOC 55, KEOC 110, APO-110 machines clean oil by electrostatic process, hence presence of moisture / water content in the oil affects the conductivity of the oil. These machines can clean oil with moisture / water content upto 500 ppm.
However if the moisture / water content in the oil exceeds 500 ppm then our models KEOC-110 DH & FDU 35 are useful. KEOC-110 DH can clean oil with a moisture content upto 1500 ppm.
If the moisture content exceeds 1500 ppm then the moisture has to be removed by FDU-35 (Flash Distillation Unit) then sent for electrostatic cleaning through KEOC-55 / KEOC-110
The Hydraulic Oil in the system may get contaminated from any of the following sources. During manufacturing of components and assembly of systems, burr, chips, weld spatter, casting sand, particles from seals and gaskets, adhesives, paint particles etc. are left in the various components which go into the oil.
Many a times oil is contaminated by the time it arrives at the users end.
Air borne dust, dirt, rust, enter into the system and then into the oil through Air breathers, seals etc.
Metal particles that are produced by abrasive wear, erosion and surface fatigue in the system itself.
Contaminations due to surrounding atmosphere and leakages in the system.
ENVAIR LAB WORKSTATIONS PROVIDE THE PERFECT BLEND OF ERGONOMICS, MODULARITY, DURABILITY, STRIKING GOOD LOOKS AND USER FRIENDLINESS.
THE ALUMINIUM EXTRUSION USED IN LAB WORKSTATION IS ROBUST, STABLE AND DISTORTION FREE. TWO MM THICK C FRAME IS PROVIDED BELOW THE TABLE TOP FOR STRAIGHTH AND FLATNESS. THIS STRUCTURE INCREASES THE UNIVERSAL LOAD BEARING CAPACITY UPTO 250-300 KG.COMPARED TO OTHERS PROVIDING UPTO 80-90 KG.
TABLE TOPS ARE AVAILABLE IN MDF, TELEPHONIC BLACK GRANITE , CHEMICAL RESISTANCE LAMINATE, MELAMINE LAMINATE, VETRIFIED TILES, STAINLESS STEEL & IMPORTED SYNTHETIC MARBLE LIKE CORIEN
ALL ADDON ACCESSORIES REQUIRED IN LAB WORKSTATIONS LIKE SINK, SECOND WORK LEVEL (REGENT RACKS) , BIN HOLDER, HOOK ON CONTAINER, EYE WASH SYSTEM ETC ARE AVAILABLE.ENVAIR LAB WORKSTATIONS HAVE CLEAN ROOM COMPATIBILITY DUE TO SELECTION OF PARTICLE NON SHEDDING MATERIALS
TABLE TOPS |
WIDTH 570,800,1140,1200,1600,1710 |
DRAWER UNITS |
WIDTH -485 |
MOBILE DRAWER UNIT |
WIDTH 485 |
STORAGE CABINETS |
WIDTH - 800,1200 |
SR.NO. |
PART OF LAB WORKSTATIONS |
ENVAIR MAKE |
OTHERS |
---|---|---|---|
01 |
TABLE TOPS |
IMPORTED COREAN TOPS |
HAVE LIMITED CHOICES |
02 |
LEGS |
ALLUMINIUM EXTRUDED. |
MS SQUARE PIPE ULD 80-90 KG. |
03. |
ELECTRICAL/DATA CABLE |
SEPARATE MODULAR ELECTRICAL BELT LINE WITH ALLUMINIUM FRONT PLATES, BEING MODULAR CAN BE FITTED AS PER REQUIREMENT EITHER ABOVE OR BELOW THE TABLE TOP AT THE TIME OF ASSEMBLY. |
OTHERS ARE USING ONLY POWER STRIPS |
04. |
DRAWER UNITS |
INDUSTRIAL SLIDES OR HEAVY DUTY INDUSTRIAL CHANNELS FOR DRAWER UNITS. UNIQUE CENTRAL LOCKING SYSTEM. |
OTHERS MAY USE NON STANDARD CHANNELS. |
05. |
2 MM MS FRAME |
PROVISION OF 2MM MS FRAME BELOW TABLE TOP FOR STRONG STRUCTURAL SUPPORT. |
OTHERS MAY PROVIDE BUT WITH SPOT WELDING . |
06. |
MODULARITY |
THE SYSTEM CAN EXTEND OR REDUCE HEIGHT AND LENGTH AS PER SITE REQUIREMENT. |
IN WELDING SYSTEM THIS FACILITY IS NOT POSSIBLE |
07 |
CLEAN ROOM COMPATABILITY |
HAVING CLEAN ROOM COMPATIBILITY. |
OTHERS DON’T HAVE DUE TO WELDING SYSTEM AND ROUGH SURFACES OF TABLE TOPS |
Envair Air Curtains form invisible thermal as well as dust barriers between controlled and outside environments. They allow easy through fare of persons & material with minimum effect of outside air on controlled environments. Hence these are most suitable for clean Factories, Hospitals, Operation Theatres & such other applications. These reduce energy bills on air-conditioning, as losses from frequent door openings, are reduced.
CABINET | Cold rolled MS Sheet, pretreated & painted with stoving enamel |
MOTOR BLOWER | Dynamically balanced & specially constructed for low noise & vibrations |
LIGHTING | Provision only for horizontal type |
Electrical supply input | 250 V AC, 1 phase, 50 Hz �?For Domestic Type 415 V AC, 3 phase, 50 Hz �?For Industrial & Heavy Duty Industrial Type |
TESTING | All units are thoroughly tested at works & meet the requirement of ISO 14644 standard generally |
FEATURES |
|
Options |
|
Model | KAC-3(D) | KAC-4(D) | KAC-5(D) | KAC-6(D) |
---|---|---|---|---|
WIDTH(W) | 900 | 1200 | 1500 | 1800 |
HEIGHT(H) | 325 | 325 | 325 | 325 |
DEPT(D) | 415 | 415 | 415 | 415 |
WEIGHT(KG) | 33 | 41 | 52 | 58 |
Longevity is specialized product that removes Allergens from indoor environments Effectively and economically. Longevity Removes microscopic particles, viruses, Bacteria, smoke, fumes etc. It uses High Efficiency Particulate Air (HEPA) FILTERS and is particularly useful for asthma patients.
The reduction of airborne allergens is particularly important for CAT and DOG Allergens. These allergens are extremely small (less than 2.5 (microns) and stay airborne for hours. At the opposite end of the spectrum, dust mite, allergens (5-50 microns) settle much Quicker and are re-launched into the air by various household activitiesLongevity contains a uniquely formulated Gas and Odor Filter media. Odors from pets, cooking, tobacco, even paint fumes, disappear without significantly reducing the airflow rate. The unit has the capability to absorb high molecular weight such as Volatile Organic Compounds (VOCs) like benzene, toluene and xylene AND for low molecular weight such as formaldehyde and hydrogen sulfide. It removes tobacco smoke from the air to improve Indoor Air Quality (IAQ). This is a useful product for
CONSTRUCTION
Filtering Media
Micro glass fiber filter paper, pleated with Aluminium spacers used for separating consecutive pleats.
Frame
GI Powder Coated / Al. Anodized / Wood.
Adhesive
Epoxy based adhesive is used for leak proof joint Between filter paper & frame
Gaskets
Sponge rubber gaskets are provided for sealing of filter on its mounting frame
PERFORMANCE
Recommended for operating efficiency of 99.97% down to particle size of 0.3 micron by DOP (Di-Octyl-Pthalate) test as per STD ISO 14644.
OPERATING CONDITIONS
Ambient temperature (max. 50 degree C) and Humidity up to 100% RH
In any working environment, particularly in commercial 7 industrial establishments, computer facilities, telephone exchanges, precision shops, suspended particulate matter like dust, pollen, smoke needs to be eliminated to ensure high quality performance by both men and machines. ENVAIR Electrostatic Air Cleaner is an ultimate effective solution to this problem as it provides clean air for all applications by recycling interior air, while saving energy costs. It purifies air efficiently without exhausting heated or cooled air. In a typical Application like currency chests in banks, no other conventional air cleaner can be effective than envair electrostatic cleaner to remove contamination from superfine dust on hates. Electrostatic Air Cleaner work on the principle of electrostatic precipitation.
CONSTRUCTION | The unit is sturdy, being made of CRCA sheet metal, welded and finished in stoving enamel paint for long life. |
Maintenance | Negligible �?The Aluminium stack is simply removed washed and is put back in position as are the fabric filters. |
Safe Operation | The unit has dual protection system. When dust layers become thicker, the efficiency drops. The protection system operates, preventing damage to power pack and stack. It also gives indication as to when stack should be cleaned. The unit trips when back door is opened for maintenance |
Versatile | The unit can work independently in a room or along with centralized air conditioning system. Ceiling suspended units are offered for various applications, which include pharmaceutical industries, restaurants and cinema halls. |
Low Power consumption | Unit draws 230 VAC single phase 50 Hz power, so no special input provision is required. |
Silent Operation | Dynamically balanced motor and blower assembly reduces both noise and vibration of the unit. |
Operating system | Airborne particles are filtered off in three stages
|
Optional- Cleaning or Washing Arrangement | Semi or fully automatic washing arrangement dry or wet can be provided With self contained water tank, detergent, heater, and timer and waste tank. For dry dust, the cleaning is possible by just conventional air blower or rapping. |
TESTING | Each unit is thoroughly tested at our works and exceeds requirements of ISO STD 14644 Class �?100. |
Model | KEA-15 | KEA-30 | ||
Overall Dimensions(mm) | 550*500*1160 | 850*500*1160 | ||
Weight (Kgs)Approx | 90 | 120 | ||
Air Handling Capacity | 15 m3/min | 30 m3/min | ||
Power Consumption(W)approx | =100W | =200W | ||
Input Voltage | 230VAC,50Hz,1Ph | |||
Filteration efficiency | Average efficency 70-85%ASHRAE 52-76 dust spot method | |||
Construction | M.S.;CRCA Stove Enameled Painted | |||
Stack Assembly | Aluminium treated for better efficiency |
ENVAIR Air Showers are fully automatic, electrically operated units, that give personnel a high velocity clean air wash, before they enter controlled clean-air environments. Air interlock system prevents contaminants from entering clean rooms, by containing them in the Air Shower itself.
Versatile ENVAIR Air Showers possess a modular joinable design. This permits single or tunnel constructions, to perfectly meet the needs of small to large users. Different sizes and flexible models of entry and exit, afford both economy of space and compatibility with user environments
Every ENVAIR Air Shower is thoroughly factory tested for high efficiency. Corrosion resistant pre-treated stove enameled, MS Sheets are used to ensure manufacturing quality that is built to last.
Bio safety cabinate Compact in design
FEATURES
CABINET | Cold rolled MS sheets pre �Ctreated &painted with stoving enamel. Alternate stainless steel 304 mat finishes.S.S. Table with mat finish. |
HEPA FILTERS | Filtration efficiency of 99.99% for particles of sizes up to 0.3 micron |
MOTOR BLOWER | Dynamically balanced and specially constructed to suit low noise and vibration |
LIGHTING | Fluorescent tube light with acrylic diffuser |
ELECTRIC SUPPLY UNIT | 230 AC, 1 Phase, 50 Hz |
TESTING | Each unit is thoroughly tested at our works and exceeds requirements of NSF-49 Std. |
DIMENSIONS | |||
---|---|---|---|
Model | Overall Dimensions | Working Dimension | |
W*D*Ht(mm) | W*D*Ht(mm) | ||
KCV-B-BIO-IIA | 1410*900*1990 | 1210*650*600 | |
KCV-M-BIO-IIA | 1025*900*1990 | 885*650*600 | |
KCV-C-BIO-IIA | 2020*900*1990 | 1820*650*600 | |
KCV-B-BIO-IIB | 1400*1250*2075 | 1220*600*500 | |
KCV-C-BIO-IIB | 2050*1250*2075 | 1830*600*500 |