Relay contacts could be typically used to actuate remote alarms, increase ventilation, shut off gas supply, or shut down a process. Should it not be feasible to install the sensor at the desired location because of maintenance, or operational consideration, a suction based sampling system can be employed. The Sensors Detectors are of very sturdy construction, with weather proof or ex-proof housings and are designed to serve for several years under normal Operating Conditions.
Detection Principle | Application Based Electrochemical , Semiconductor or PID |
---|---|
Response Time | <5seconds |
Zero drift | 0.2% Fs |
Accuracy | 2%Fs |
Operating Voltage | 22-30 Volt DC |
Operating Temperature | 0-50 C |
Terminations | PCB mounted terminal blocks toaccept 1.5mm wires |
Display | lnbuilt 0.5n LCD |
Output | 4- 20 mA Linear/0 - lVolts DC (V)/RS232/RS485 2 wire (Electrochernical sensor based, Dew point, Humidity, Temp, Moisture, Vapour Pressure) 3 Wire (Cumbustible, Toxic Gas) |
Power Consumption | 2 wire: 0.5 W max./ 3 wire: 3.6 W max. |
Max. Load | 600Ohms |
Mounting | 2" Pipe (U clamps will be provided) |
Endee Model RHT 98 Relative Humidity Transmitter are Precision instrument designed for monitoring Relative Humidity or Moisture in rugged industrial application and environment.
Endee Relative Humidity Controllers are designed for monitoring Relative Humidity in rugged industrial use. They employ advanced digital technology to provide reliable and highly accurate Relative Humidity Measurement with excellent repeatability & linearity range of 0-100% Humidity is optimised over the temperature range of -40deg.C to +80deg.C as such seperate temperature measurement is not required.
The well proven Capacitive CMOS IC Sensor offer exceptional resistance to common contaminants like organic vapours. They are washable, dont require clean environment or a constant supply of moisture or frequent servicing.
Incorporating the state of the art design and latest sensing principle these transmitters provide a quick payback through significant reduction in maintenance costs and providing accuracies that direct contribute to the quality of the product.
Range | 0-100% RH. |
---|---|
Minimum Resolution | 0.1% |
Indication . | Digital |
Sensor | CO MOS IC Capacitive Sensor |
Sensor Protection | Teflon Filter or Sintered Metallic Filter optional |
Calibration | Single Point Field Calibration |
Accuracy | <±0.2% of range span |
Operating Temp. (Optimised ) | -40deg.C to +85deg.C |
Storage Temp. | 0-50 deg.C |
Temp. Compesation | Optimised for operating temp. measurement |
Repeatability . | ±0.5% |
Hystersis | ±1% |
Power | 2-Wire, 24V Loop Powered (DC) |
Housing | High Impact Plastic |
Dimension | 120 X 120 X 100 X (D) in mm |
Response Time | Less than 10Sec. for 70% step Change |
Output | 4-20mA linear (max load 600 ohms) |
Calibration Adjustment | Zero & Span |
Power Consumption | 0.5 W |
Ordering Information | Model : I - Integral Sensor R- Remote Sensor |
Relay contacts could be typically used to actuate remote alarms, increase ventilation, shut off gas supply, or shut down a process. Should it not be feasible to install the sensor at the desired location because of maintenance, or operational consideration, a suction based sampling system can be employed. The Sensors Detectors are of very sturdy construction, with weather proof or ex-proof housings and are designed to serve for several years under normal Operating Conditions.
Detection Principle | Application Based Electrochemical , Semiconductor or PID |
---|---|
Response Time | <5seconds |
Zero drift | 0.2% Fs |
Accuracy | 2%Fs |
Operating Voltage | 22-30 Volt DC |
Operating Temperature | 0-50 C |
Terminations | PCB mounted terminal blocks toaccept 1.5mm wires |
Display | lnbuilt 0.5n LCD |
Output | 4- 20 mA Linear/0 - lVolts DC (V)/RS232/RS485 2 wire (Electrochernical sensor based, Dew point, Humidity, Temp, Moisture, Vapour Pressure) 3 Wire (Cumbustible, Toxic Gas) |
Power Consumption | 2 wire: 0.5 W max./ 3 wire: 3.6 W max. |
Max. Load | 600Ohms |