Our Products
Sensors
2 Products availableLamps
2 Products availableWe are leaders in the market for providing best range of VOC-GAS-MONITOR, UNIVERSAL-MULTI-GAS-MONITOR, AREA-GAS-MONITOR, FIXED-GAS-MONITOR and PORTABLE GAS MONITORS
This micro controller based intellegent Detector is highly sensitive to VOC and solvent vapor. The LCD displays the level of gas or the vapors present. An audible alarm alerts you of dangerous levels with response in seconds. On start-up, it goes through self integrity check before getting into measurement mode.
No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4X1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitoring While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling.
Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.
Display | Alphanumeric LCD 2 X 16 |
---|---|
Sampling | Diffusion or Suction |
Calibration | Automatic zero & span with fresh air sample Calibration gases |
Response Time | <10 seconds at 95% variant |
Power Supply | Internal Ni-cad battery |
Working Temperature | -5째Cto 55째 C |
Storage Temperature | -20째C to 45째C |
Case | High Impact Plastic (NEMAIP40) |
External Dimension | 170X100X130mm |
Weight | 750gm (with battery) |
Probe (optional) | 6mm, Dia SS 600 mm length with 1 meter Neoprene Hose standard |
Accessories | Battery charger, operation manual |
Sampling | Diffusion (D),Suction (S) |
Target Gases | VOC & other gases with Ionization Potential < 10.6eV |
---|---|
Case | High Impact PC/ABS |
Dimensions | 170 X 100 X 130 mm approximately |
Detector | Plug-in PID (Photo Ionization Detector) |
Ionization Lamp Energy | 10.6 eV Standard |
Measuring Ranges | i) 0-20 PPM ii) 0 - 2000 PPM |
Resolution | Minimum Detectable Quantity i) 0.1 PPM (Isobutylene) for Range 1 ii) 0.1 PPM for Range 2 |
Power Source | Rechargeable Batteries |
Sample Flow Rate | 0.5 LPM |
Temperature Range | 14째F to 104째F (0째C to 50째C) typical |
Humidity Range | 0 to 90% RH (Non-Condensing) |
Response Time | < 20 seconds |
Model 2620 single channel digital control modules are designed to supervise and display the status of a single integral or remote (2620 R) sensor assembly. Model 2620 is housed in a NEMA AX wall mount enclosure or Ex- proof enclosure.
Model 2620R Single Channel controllers interface with industry standard two or three wire 4-20 mA sensor or other standard voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarm levels. The 3 J4 digit LCD or Alphanumeric LCD display can read the concentration. LEDs on the front panel provide indication of all three alarms.
The alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps, to provide direct alarm action, reducing the need for interposing relays. Local Alarm devices can be connected to the configurable on board alarms. The Fail Safe Supervisory provides a reliable indication that the Monitor is fully operational. I he "hail Safe" design monitors the input power and status of the power supply for the amplifiers. A failure of any one of these functions illuminates a "Fault" Light Emitting Diode.
The HEART of any Analytical system is the SENSOR. It is the most critical component in overall system performance. Because no single sensor technology is ideal for all applications, ENDEE offers TEN different sensor technologies.
This capability is mandatory in today's complex industrial market. Command of each of these technologies enables us to "FITTHE PRODUCTTO THE APPLICATION", and assure long-term service and reliability & optimal performance in every application.
The Monitor is a Single Gas Multi-purpose monitor that combines simplicity and high performance in a low cost low maintenance package.
The rugged NEMA 4X or 7X assembly is suitable for a variety of industrial, commercial and general purpose applications to monitor HAZARDOUS, Toxic gases or Oxygen iri Process Fuel Gas or Ambient Air.
The HEART of any Analytical system is the SENSOR. It is the most critical component in overall system performance. Because no single sensor technology is ideal for all applications, ENDEE offers TEN different sensor technologies.
This capability is mandatory in today's complex industrial market. Command of each of these technologies enables us to "FITTHE PRODUCTTO THE APPLICATION", and assure long-term service and reliability & optimal performance in every application.
Minimum Resolution | 0.1 or 1 unit of the range. |
---|---|
Indication | Digital Continuous |
Mounting | Wall |
Sensor Technology | Appropriate to Application |
Detection Method | Diffusion / Sample Draw Pump. |
Accuracy | ±2% |
Linearity | ±2% |
Relative Humidity | 0 - 99% Non-condensing |
Response Time | (90% in 10 seconds) |
Signal Output Recorder | 0-IV, 4-20 mA (Optional) |
Alarm Setting | High and Very High Adjustable over full range |
Alarm Circuits | SPDT 5 AMP 220V Contacts |
Controls | Zero, Span, Alarm Setting |
Power Source | 110V or 220V 50 Hz. 24 VD C (Optional) |
Dimensions | Model 2620 - 250 X 200 X 100mm |
Gases | Ranges | Gases | Ranges |
---|---|---|---|
Hydrogen | 0- -100 to 2000 PPM | Hydrogen Sulphide | 0-5 to 2000 PPM |
Chlorine | 0- • 3 to 2000 PPM | Nitric Oxide | 0-100 1000 PPM< |
Bromine | 0- • 3 to 2000 PPM | Nitrogen Dioxide | 0-30 to 100 PPM |
Fluorine | 0- •1 to 10 PPM | Ammonia | 0-300 PPM |
Hydrogen Chloride | 0- •5 to 15 PPM | Org. Solvents/Vapours | Depending on Solvents |
Hydrogen Fluoride | 0- • 5 to 15 PPM | Oxygen | 0 - 30% to 100% |
Hydrogen Cyanide | 0 •10 to 100 PPM | LPG/CNG/H2 | 0-100%LEL |
Carbon Dioxide | 0- • 05% to 20% | Combustible Gases | 0 -100% V/V |
Compact, Light Weight Intelligent Unit with Application Specific Sensors Sensitive to PPB / PPM Or %V/V levels of Gases & Vapors.The advanced Micro controller technology employed makes these ALERT METERS highly dependable, reliable and accurate. The complete automatic operation and calibration feature leaves no
No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4 X 1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitori ng While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling.
Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.
Overall Ranges | PPB / PPM / %V/V / %LEL |
---|---|
Sampling Method | Diffusion (D) or Suction (S) |
Principle | Specific to Application |
Sensor Life | 2-5 years |
Measurement | Continuous |
Readout | 0.1 or 1 PPM / % as applicable |
Accuracy | ± 2% & 0.5% for oxygen |
Repeatability | ± 1% |
Response Time | < 10 seconds at 95% variation |
Alarms | Low & HI Visual and Audible (Different Tones) |
Low Battery Alarms | Audio & Visual |
Power Supply | Standard 6VDc Battery |
Battery Life | 6 to 8 hours |
Housing | High Impact Plastic (ABS) |
Size & Weight | 119(H) X 80(L) X 25(D); 135 gm |
Temperature Range | 0-55 °C |
Warranty | One year |
Compact, Light Weight Intelligent Unit with Application Specific Sensors Sensitive to PPB / PPM Or % i age levels of Gases & Vapors.The advanced Micro controller technology employed makes these ALERT METERS highly dependable, reliable and accurate. The complete automatic operation and calibration feature leaves no
compact, portable construction and simplicity of operation makes hnl portable gas analyser a valuable aid for insitute use in constantly changing measurement sites. Its versatile modular design permits configuration and upgradation to suit specific needs. You determine the number of sensors for your instrument from (1 to 8) or should your analyzer have a built-in printer or rs 232 output or a smoke test probe so you pay only for what you need. The highly upgradable a - 116 model can be ac powered andor battery operated. It may include a chargeable battery, battery charger, sampling probe with condensate trap and an inline micro filter and an inbuilt sampling pump. It can be built to include upto 8 nos. Of gas sensors and temperature sensor, draft pressure besides the calculated parameters and have options of : 1. Data logger 2. Integral printer 3. Rs 232 output 4. Date & time 5. Facility for automatic analysis for specified periods at preset intervals. Self check of components and functions by special software ensures perfect functioning of the unit, thereby accurate analysis data. Any unacceptable deviation from the standard stored values is displayed as an indication fault. Instant printout (with time and date) confirms the displayed readings that have been measured and calculated at the point of test. The instrument may also be instructed to sample and analyze for specified periods at preset intervals completely unattended. Software package to store and analyze the data in various manners with pc xt, at, 386, 486.
the stack guard series operate on the principle of tribo - electric charge transfer. The electrical charge carried by dust particles is captured by a highly sensitive tribo - electric probe, amplified and then transmitted to the control unit. As the current generated by the charge is proportional to the concentration of particles present, an indicative signal of dust presence results. Stack guard is most suitable for use in low humidity gas streams with reasonably constant flows. The control unit is mains powered, & incorporates alphanumeric display with adjustable alarm levels. 1. Dust levels at which the red led light, alarm is triggered 2. The emissions level at which the audible and visual alarm is triggered