Our Products
Display | A) Oxygen B) Different Temp. C) Efficiency D)CO E) C02 (Calculated) Lambda (Calculated) |
0-25% in Stack Gas 25-650 deg.C 0-99.0% 0-2000 PPM 0-25% |
---|---|---|
Resolution | A) Oxygen B) Different Temp. C) Efficiency D)CO |
0.1% 0.1% 0.1% 1PPM |
Display | Alpha Numeric LCD | |
Fuels | User Selectable Oil, Coal , Gas | |
Sensors | Electrochemical Type K Thermocouple | |
Calibration | Automatic with Fresh Air Sample | |
Accuracy | Oxygen Temp Efficiency |
+/- 0.25% +/- 0.25% +/- 0.25% |
Response Time | Maximum 30Sec. at 95% Variation | |
Self Diagnosis | Combustion efficiency test with diagnostic indications | |
Power Supply | Internal Ni-cad battery pack with external charger 220V 50Hz Ac (Optional 110V50H2) | |
Working Temp | -5deg X to 55 deg.C | |
Storage Temp | -20 deg.C to 50 deg.C | |
Replacable Cartridge | -20 deg.C to 50 deg.C | |
Case | ABS Plastic | |
External Dimension | 222X105X40mm | |
Weight | 500 gms. | |
Accessories | Leather case with shoulder strap Battery charger, Operational Manual |
Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.
Display | AlphanumericLCD 2X16 |
---|---|
Sampling Method | Direct Plug In, Suction Optional |
Calibration | Automatic zero & span with Calibration gases |
Response Time | <10 seconds at 95% variant |
Power Supply | Internal Ni-cad battery |
Working Temperature | -5Deg.Cto 55Deg.C |
Storage Temperature | -20Deg.C to45Deg.C |
Case | High Impact Plastic |
External Dimension | 160X95 X 30 mm approximately |
Weight | 390Gm (with battery) |
Output | Digital, RS232 |
Accessories | Battery charger,operation manual |
Sensor Technologies Analyser is built up using sensors technology to suit specific application. Batteries Long life rechargeable batteries. Diffusion or Suction with Time tested, sturdy, high suction in-built pump supervisory circuit continuously monitors the pump against failure. Disposable Cartridge Line Filter & Moisture Separator Low porosity, disposable cartridge line filter & moisture separator suitably conditions the sample.
Calibration A built-in procedure allows easy and automatic span sensor calibration using stand; 3rd gas cylinder. Periodic zero calibration is automatic on demand. Electronic Flow Meter An automatic built-in system measures a flow of sampling gas to obtain a constant sampling volume. Multi Fuel Selection The fuel efficiency analyser can be programmed for selection upto 10 fuels for calculating combustion values.
Gas Probes & Sampling System Flue gas sampling probes with different lengths, shapes i and max, operating temperatures Upto 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications. Heated Sampling Hose A heated sampling Hose is available for high temperature applications. A heated hose allows flue gas sampling without condensation. Continuous Monitoring The industrial design and the advanced technology applied to the unit, allows it to perform long term gas analysis
PROBES - APPLICATION SPECIFIC AVAILABLE Ambient CO Probe An optional probe to monitor ambient CO concentration to keep the operator in a safe environment. Gas Sniffer Probe To detect and locate the precise position of a gas leak in a pipe network or equipment. Smoke Index Smoke Index measurement can be obtained using a specia 1 heated probe, supplied on request, and through a dedicated internal procedure that computes the required volume of gas sample flowing into the specific filter. The results can be obtained by comparison with the Smoke Index Table.
Gas Velocity An internal procedure allows gas velocity measurements using the differential pressure inlet combined with a pitot tube. Report of Calibration Each instrument is factory calibrated and certified against Endee's Standard Gasses and shipped with a Report of Calibration stating the nominal and actual values and the deviation error. Quality System Research, development, production, inspection and certification activities are defined by methods and procedures of the Endee's System inspected for compliance and certified ISO 9001.
Display | High quality Alpha Numeric LCD. |
---|---|
Calibration | Automatic Zero On Start with fresh air sample. |
SPAN Calibration | automatic with calibration gas. |
Response Time | Vlaximum 20 seconds at 95% variation |
Power Supply | Internal battery pack with external charger 220V/50 Hz |
Working Temperature | -5Deg.Cto 55Deg.C |
Storage Temperature | -20Deg.C to45Deg.C |
Case | Aluminum |
External Dimension | 170X100X130 mm |
Weight | 1.5 Kg |
Probe(optional) | (i) 8mm, Dia SS 600 mm length with 2 meter Hose Probes of other material & length available. (ii) Sniffer Probe : To detect & locate the precise position of Gas leak in a pipe network. |
Accessories | Leather case with shoulder strap, battery charger, operational manual. |
The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters.
It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault",
Sensor & sampling | Gas Ranges & Application dependent. |
---|---|
Display | Digital Standard LED optional alphanumeric display |
Power Supply | 100-290VAC/47-63HZ |
Ambient Temp | 0-50째 C |
Enclosure | Aluminium casing (power coated) for indoor application |
Mounting | Standard: 19" Rackmounted |
Optional | Flush on Panel/Tabletop |
Warm uptime: | Analysis Detectordependent |
Output(Optional) | 4-20mA |
Alarms | Two Level (selectable range) |
Sample Gas condition | Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired. |
Calibration | Manual, On command in microprocessor based system. |
We are offering portable flue gas analyzer.
sturdy stainless steel sampling probe with extension tubing for ease of measurement. Thermocouple in the tip of probe measures temperature at point of sampling to minimize error. Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure. Inline filter to inbuilt moisture & dust, disposable easy to replace filter element. Supervisory diagnostic circuit continuously checks it against choking. Retains the readings till the next sampling. Compact aluminum housing rechargeable ni-cad battery pack with charger. Maintenance & spare parts : designed for free maintenance operation. Long life sensor. Combustion efficiency is determined by oxygen content and temperature of fuel gases. An excess air (oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (oxygen) produces an incomplete I combustion with consequent higher costs and increased polluting emissions.
The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser.
The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications changing the Measuring Parameters.
It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific Needs of Customer in Selection of Gases to Be Measured.
Optionally Lndee Ca 2000 Is Available With 1 lighly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault".
Measuring Gas & Range | Click Here |
---|---|
Sensor & sampling | Gas Ranges & Application dependent. |
Display | Digital Standard LED optional alphanumeric display |
Power Supply | 100-290VAC/47-63HZ |
Ambient Temp | 0-50째C |
Enclosure | High Impact Plastic |
Mounting | FieldMounted |
Optional | Flushon Panel/Table top |
Warm uptime | Analysis Detector-dependent |
Output(Optional) | 4-20mA |
Alarms | Two Level (selectable range) |
Sample Gas condition | Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system is required |
Calibration | Manual, On command in microprocessor based system. |
he Model 7001 is a Rugged, Portable, Easy-to-use Gas Analyser that monitors purge gases and the cooling gas in hydrogen-cooled turbine generators. It measures hydrogen in air & hydrogen in C02 as well as C02 in air during maintenance purging of hydrogen rooted turbine generators. Switch selectable ranges on the instrument make it easytochoosethe measurement required.
Technique | Advanced Dual Sensor Technology |
---|---|
Optional | Single Sensor Technology IR/UV Sensor Technology |
Resolution | 0-1 ppm (CO, NO, No2, & S02); 0.1% (Co2) |
Linearity | <2% of range |
Zero drift | <2% of range per month |
Span drift | <2% of range per month |
02 Ranges | 0-5 Vol% to 0-25 Vol% |
Resolution | 0.01 Vol% |
Linearity | <0.2 Vol% |
Zero drift | *0.2 Vol% per month |
Span drift | <0.2 Vol% per month |
Calibration method | Manual or Automatic 2-Point calibration span and zero automatic gas selection (option) |
Display Type | Alpha numeric LCD back light |
Analogue outputs | Isolated current loops One per gas 4-20 mA |
Relays outputs | One per gas |
Relay rating | Isolated changeover contacts rated 0.5A @ 125V a.c; V d.c |
Communications | RS 232 or R5 485 Modbus serial digital data bus (2 or 4 wire) |
Enclosure | 19" Rack |
Operating Temp | 40deg C to + 50deg C |
Power consumption | 400 w |
Instrument air (0 calibration) | 4 bar/ 60 psi min. clean dry & solvent free; 10 1/min |
Calibration gas (recommended) | 1 bar/15 psi; 2L/min approx |
Calibration gas type | Specific to each gas type & measurement span |
Dimensions (H x W x D) | < 20 seconds |
Response Time | 1570x600x370 mm |
Options | 24x24x12 mm |