Gas Analyzers #1118256

Fuel Gas Analyzer

  • Long life zirconium sensor
  • Very fast response, no purgetime
  • No reference gas required
  • High accuracy
  • Wide measurement range 1 ppm to 96%
  • Simpletooperate
  • Maintenance free
  • automatic & begins with every start up with fresh air aspirated instead of Gas sample.
  • Automatic self check for efficiency calculation :With aspirated fresh air specific percentage efficiency of the selertpd Fuel is displayed as a cherk nn its calculations.
  • Self Supervisory Diagnosis : Continuously checks the status of: 1) Battery Voltage 2) Sample Flow 3) Oxygen Sensor
  • Sturdy stainless steel sampling probe with extension tubing for ease of measurement.
  • Thermocouple in the tip of probe measures temperature at point of sampling to minimise error.
  • Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure.
  • Inline Filter to Inbuilt Moisture & Dust, Disposable easy to replace filter element. Supervisory Diagnostic circuit continuously checks it against choking.
  • Retains the readings till the next sampling.
  • Compact Aluminum Housing
  • Rechargeable Ni-cad battery pack with charger.
  • Maintenance & Spare Parts : Designed for free maintenance operation. Long Life Sensor.
  • Combustion efficiency is determined by Oxygen content and temperature of Fuel gases. An excess air (Oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (Oxygen) produces an incomplete i combustion with consequent higher costs and increased polluting emissions.

Display A) Oxygen 
B) Different Temp.
C) Efficiency
D)CO
E) C02 (Calculated)
Lambda (Calculated)
0-25% in Stack Gas
25-650 deg.C
0-99.0%
0-2000 PPM
0-25%
Resolution A) Oxygen 
B) Different Temp.
C) Efficiency
D)CO
0.1%
0.1%
0.1%
1PPM
Display Alpha Numeric LCD
Fuels User Selectable Oil, Coal , Gas
Sensors Electrochemical Type K Thermocouple
Calibration Automatic with Fresh Air Sample
Accuracy Oxygen
Temp
Efficiency
+/- 0.25%
+/- 0.25%
+/- 0.25%
Response Time Maximum 30Sec. at 95% Variation
Self Diagnosis Combustion efficiency test with diagnostic indications
Power Supply Internal Ni-cad battery pack with external charger 220V 50Hz Ac (Optional 110V50H2)
Working Temp -5deg X to 55 deg.C
Storage Temp -20 deg.C to 50 deg.C
Replacable Cartridge -20 deg.C to 50 deg.C
Case ABS Plastic
External Dimension 222X105X40mm
Weight 500 gms.
Accessories Leather case with shoulder strap Battery charger, Operational Manual



















View Complete Details

PORTABLE GAS-ANALYZER

Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.

  • Complete Automatic Operation
  • Self Diagnostic Check
  • Applications specific Sensor Technology.
  • Continuous Stable Alphanumeric display
  • Long Life Rechargeable Batteries
  • Data logging and 232 Output Capability
  • On Start up, the intrument goes through complete Self Integrity, Check Calibration Check on Demand.
  • Digitally Displays the result Instantly.

Display AlphanumericLCD 2X16
Sampling Method Direct Plug In, Suction Optional
Calibration Automatic zero & span with Calibration gases
Response Time <10 seconds at 95% variant
Power Supply Internal Ni-cad battery
Working Temperature -5Deg.Cto 55Deg.C
Storage Temperature -20Deg.C to45Deg.C
Case High Impact Plastic
External Dimension 160X95 X 30 mm approximately
Weight 390Gm (with battery)
Output Digital, RS232
Accessories Battery charger,operation manual
View Complete Details

MULTI-DUST-GAS-ANALYZER

Sensor Technologies Analyser is built up using sensors technology to suit specific application. Batteries Long life rechargeable batteries. Diffusion or Suction with Time tested, sturdy, high suction in-built pump supervisory circuit continuously monitors the pump against failure. Disposable Cartridge Line Filter & Moisture Separator Low porosity, disposable cartridge line filter & moisture separator suitably conditions the sample.

Calibration A built-in procedure allows easy and automatic span sensor calibration using stand; 3rd gas cylinder. Periodic zero calibration is automatic on demand. Electronic Flow Meter An automatic built-in system measures a flow of sampling gas to obtain a constant sampling volume. Multi Fuel Selection The fuel efficiency analyser can be programmed for selection upto 10 fuels for calculating combustion values.

Gas Probes & Sampling System Flue gas sampling probes with different lengths, shapes i and max, operating temperatures Upto 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications. Heated Sampling Hose A heated sampling Hose is available for high temperature applications. A heated hose allows flue gas sampling without condensation. Continuous Monitoring The industrial design and the advanced technology applied to the unit, allows it to perform long term gas analysis

PROBES - APPLICATION SPECIFIC AVAILABLE Ambient CO Probe An optional probe to monitor ambient CO concentration to keep the operator in a safe environment. Gas Sniffer Probe To detect and locate the precise position of a gas leak in a pipe network or equipment. Smoke Index Smoke Index measurement can be obtained using a specia 1 heated probe, supplied on request, and through a dedicated internal procedure that computes the required volume of gas sample flowing into the specific filter. The results can be obtained by comparison with the Smoke Index Table.

Gas Velocity An internal procedure allows gas velocity measurements using the differential pressure inlet combined with a pitot tube. Report of Calibration Each instrument is factory calibrated and certified against Endee's Standard Gasses and shipped with a Report of Calibration stating the nominal and actual values and the deviation error. Quality System Research, development, production, inspection and certification activities are defined by methods and procedures of the Endee's System inspected for compliance and certified ISO 9001.

  • Complete Automatic operation Complete Automatic operation includinc Calibration, "ON - OFF" & "SAMPLE" Keys only.
  • Self diagnostic check Self diagnostic check & specific fault indication, Discrete LEDs for Sample Flow, Sensor Efficiency & Battery Condition.
  • Self-integrity Check Continuous on-line full self-integrity check eliminates wrong measurements due to Instrument Faults.
  • USER Friendly Visual Messages on status on functioning.
  • Proven Sensor Technology Special purpose long life Sensors with Cross Interference filters to achieve high accuracy.
  • Oxygen Sensor Guaranteed for 4 years.Display of Concentrations Continuous, Stable & Automation display of concentrations - ensures maximum accuracy & reliability.

Display High quality Alpha Numeric LCD.
Calibration Automatic Zero On Start with fresh air sample.
SPAN Calibration automatic with calibration gas.
Response Time Vlaximum 20 seconds at 95% variation
Power Supply Internal battery pack with external charger 220V/50 Hz
Working Temperature -5Deg.Cto 55Deg.C
Storage Temperature -20Deg.C to45Deg.C
Case Aluminum
External Dimension 170X100X130 mm
Weight 1.5 Kg
Probe(optional) (i) 8mm, Dia SS 600 mm length with 2 meter Hose Probes of other material & length available. 
(ii) Sniffer Probe : To detect & locate the precise position of Gas leak in a pipe network.
Accessories Leather case with shoulder strap, battery charger, operational manual.

View Complete Details

PROCESS-GAS-ANALYZER

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault",

  • Alarms for Low & High and Specific Fault
  • Specific Sensor as Per the Measuring Gas, Range & Application
  • Sample Conditioning System Offered As Per Application
  • Complete Automatic Operation
  • 16 Characters; 2 Line LCD Display Messages
  • Self Diagnostic Check Facility
  • A Mere Six Key to Operate the Complete Instrument

Sensor & sampling Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째 C
Enclosure Aluminium casing (power coated) for indoor application
Mounting Standard: 19" Rackmounted
Optional Flush on Panel/Tabletop
Warm uptime: Analysis Detectordependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired.
Calibration Manual, On command in microprocessor based system.
 
View Complete Details

Portable Flue Gas Analyzer

75,000 - 1.05 Lakh /Piece Get Latest Price
  • Driven Type Battery
  • Automation Grade Manual

We are offering portable flue gas analyzer.

sturdy stainless steel sampling probe with extension tubing for ease of measurement. Thermocouple in the tip of probe measures temperature at point of sampling to minimize error. Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure. Inline filter to inbuilt moisture & dust, disposable easy to replace filter element. Supervisory diagnostic circuit continuously checks it against choking. Retains the readings till the next sampling. Compact aluminum housing rechargeable ni-cad battery pack with charger. Maintenance & spare parts : designed for free maintenance operation. Long life sensor. Combustion efficiency is determined by oxygen content and temperature of fuel gases. An excess air (oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (oxygen) produces an incomplete I combustion with consequent higher costs and increased polluting emissions.

View Complete Details

FILED-MOUNTED-GAS-ANALYZER

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser.

The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications changing the Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific Needs of Customer in Selection of Gases to Be Measured.

Optionally Lndee Ca 2000 Is Available With 1 lighly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault".

  • Alarms for Low & High and Specific Fault
  • Specific Sensor as Per the Measuring Gas, Range & Application
  • Sample Conditioning System Offered As Per Application
  • Complete Automatic Operation
  • 16 Charachters 2 line LCD Display messages
  • A Mere Six Key to Operate the Complete Instrument

Measuring Gas & Range Click Here
Sensor & sampling Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째C
Enclosure High Impact Plastic
Mounting FieldMounted
Optional Flushon Panel/Table top
Warm uptime Analysis Detector-dependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. 
Other than this suitable sample, Conditioning system is required
Calibration Manual, On command in microprocessor based system.

View Complete Details

FLUE-GAS-ANALYZER

he Model 7001 is a Rugged, Portable, Easy-to-use Gas Analyser that monitors purge gases and the cooling gas in hydrogen-cooled turbine generators. It measures hydrogen in air & hydrogen in C02 as well as C02 in air during maintenance purging of hydrogen rooted turbine generators. Switch selectable ranges on the instrument make it easytochoosethe measurement required.

  • Fully integrated system Up to 7 gases in a single compact analyser
  • Wide measurement range
  • From 0 -100 PPM up to 0 -10, 000 PPM
  • Widely accepted, certified performance
  • Complies with the latest monitoring standards
  • Simple installation & maintenance
  • Requires no specialist skills or training,
  • all maintenance carried out on-site
  • Highest measurement perlumidnce
  • Ultra - low drift measurement technology
  • Measured Total NOx (NO+N02) Separate sensors for Lrue NOx monitoring,
  • Record and store vital emission data
  • Internal data logging function
  • Combustion efficiency measurement option
  • For a Optimization process efficiency where condition are changing

Technique Advanced Dual Sensor Technology
Optional Single Sensor Technology 
IR/UV Sensor Technology
Resolution 0-1 ppm (CO, NO, No2, & S02); 0.1% (Co2)
Linearity <2% of range
Zero drift <2% of range per month
Span drift <2% of range per month
02 Ranges 0-5 Vol% to 0-25 Vol%
Resolution 0.01 Vol%
Linearity <0.2 Vol%
Zero drift *0.2 Vol% per month
Span drift <0.2 Vol% per month
Calibration method Manual or Automatic 2-Point calibration span and zero automatic gas selection (option)
Display Type Alpha numeric LCD back light
Analogue outputs Isolated current loops One per gas 4-20 mA
Relays outputs One per gas
Relay rating Isolated changeover contacts rated 0.5A @ 125V a.c; V d.c
Communications RS 232 or R5 485 Modbus serial digital data bus (2 or 4 wire)
Enclosure 19" Rack
Operating Temp 40deg C to + 50deg C
Power consumption 400 w
Instrument air (0 calibration) 4 bar/ 60 psi min. clean dry & solvent free; 10 1/min
Calibration gas (recommended) 1 bar/15 psi; 2L/min approx
Calibration gas type Specific to each gas type & measurement span
Dimensions (H x W x D) < 20 seconds
Response Time 1570x600x370 mm
Options 24x24x12 mm

View Complete Details

Portable Gas Analyzer

  • Weight 390Gm (with battery)
Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Gas Analyzers from Mumbai, Maharashtra by Endee Engineers Pvt. Ltd.
Post Buy Requirement
Endee Engineers Pvt. Ltd.

Endee Engineers Pvt. Ltd. Mumbai, Maharashtra

Mumbai, Maharashtra, India
Verified Add Review

Our Products

  1. Computer Monitor 13 Products available
  2. Gas Analyzers 8 Products available
  3. Measuring Instruments & Equipment 7 Products available
  4. Laboratory Equipments 5 Products available
  5. Leak Detectors 5 Products available
  6. Fire Alarm System 3 Products available
  7. Transmitter Device 3 Products available
  8. Sensors

    2 Products available
  9. Lamps

    2 Products available
  10. Others Products 25 Products available

Gas Analyzers #1118256

We offer the best product range of fuel gas analyzer, PORTABLE GAS-ANALYZER, MULTI-DUST-GAS-ANALYZER, PROCESS-GAS-ANALYZER and Portable Flue Gas Analyzer.

Fuel Gas Analyzer

  • Long life zirconium sensor
  • Very fast response, no purgetime
  • No reference gas required
  • High accuracy
  • Wide measurement range 1 ppm to 96%
  • Simpletooperate
  • Maintenance free
  • automatic & begins with every start up with fresh air aspirated instead of Gas sample.
  • Automatic self check for efficiency calculation :With aspirated fresh air specific percentage efficiency of the selertpd Fuel is displayed as a cherk nn its calculations.
  • Self Supervisory Diagnosis : Continuously checks the status of: 1) Battery Voltage 2) Sample Flow 3) Oxygen Sensor
  • Sturdy stainless steel sampling probe with extension tubing for ease of measurement.
  • Thermocouple in the tip of probe measures temperature at point of sampling to minimise error.
  • Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure.
  • Inline Filter to Inbuilt Moisture & Dust, Disposable easy to replace filter element. Supervisory Diagnostic circuit continuously checks it against choking.
  • Retains the readings till the next sampling.
  • Compact Aluminum Housing
  • Rechargeable Ni-cad battery pack with charger.
  • Maintenance & Spare Parts : Designed for free maintenance operation. Long Life Sensor.
  • Combustion efficiency is determined by Oxygen content and temperature of Fuel gases. An excess air (Oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (Oxygen) produces an incomplete i combustion with consequent higher costs and increased polluting emissions.

Display A) Oxygen 
B) Different Temp.
C) Efficiency
D)CO
E) C02 (Calculated)
Lambda (Calculated)
0-25% in Stack Gas
25-650 deg.C
0-99.0%
0-2000 PPM
0-25%
Resolution A) Oxygen 
B) Different Temp.
C) Efficiency
D)CO
0.1%
0.1%
0.1%
1PPM
Display Alpha Numeric LCD
Fuels User Selectable Oil, Coal , Gas
Sensors Electrochemical Type K Thermocouple
Calibration Automatic with Fresh Air Sample
Accuracy Oxygen
Temp
Efficiency
+/- 0.25%
+/- 0.25%
+/- 0.25%
Response Time Maximum 30Sec. at 95% Variation
Self Diagnosis Combustion efficiency test with diagnostic indications
Power Supply Internal Ni-cad battery pack with external charger 220V 50Hz Ac (Optional 110V50H2)
Working Temp -5deg X to 55 deg.C
Storage Temp -20 deg.C to 50 deg.C
Replacable Cartridge -20 deg.C to 50 deg.C
Case ABS Plastic
External Dimension 222X105X40mm
Weight 500 gms.
Accessories Leather case with shoulder strap Battery charger, Operational Manual



















View Complete Details

PORTABLE GAS-ANALYZER

Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.

  • Complete Automatic Operation
  • Self Diagnostic Check
  • Applications specific Sensor Technology.
  • Continuous Stable Alphanumeric display
  • Long Life Rechargeable Batteries
  • Data logging and 232 Output Capability
  • On Start up, the intrument goes through complete Self Integrity, Check Calibration Check on Demand.
  • Digitally Displays the result Instantly.

Display AlphanumericLCD 2X16
Sampling Method Direct Plug In, Suction Optional
Calibration Automatic zero & span with Calibration gases
Response Time <10 seconds at 95% variant
Power Supply Internal Ni-cad battery
Working Temperature -5Deg.Cto 55Deg.C
Storage Temperature -20Deg.C to45Deg.C
Case High Impact Plastic
External Dimension 160X95 X 30 mm approximately
Weight 390Gm (with battery)
Output Digital, RS232
Accessories Battery charger,operation manual
View Complete Details

MULTI-DUST-GAS-ANALYZER

Sensor Technologies Analyser is built up using sensors technology to suit specific application. Batteries Long life rechargeable batteries. Diffusion or Suction with Time tested, sturdy, high suction in-built pump supervisory circuit continuously monitors the pump against failure. Disposable Cartridge Line Filter & Moisture Separator Low porosity, disposable cartridge line filter & moisture separator suitably conditions the sample.

Calibration A built-in procedure allows easy and automatic span sensor calibration using stand; 3rd gas cylinder. Periodic zero calibration is automatic on demand. Electronic Flow Meter An automatic built-in system measures a flow of sampling gas to obtain a constant sampling volume. Multi Fuel Selection The fuel efficiency analyser can be programmed for selection upto 10 fuels for calculating combustion values.

Gas Probes & Sampling System Flue gas sampling probes with different lengths, shapes i and max, operating temperatures Upto 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications. Heated Sampling Hose A heated sampling Hose is available for high temperature applications. A heated hose allows flue gas sampling without condensation. Continuous Monitoring The industrial design and the advanced technology applied to the unit, allows it to perform long term gas analysis

PROBES - APPLICATION SPECIFIC AVAILABLE Ambient CO Probe An optional probe to monitor ambient CO concentration to keep the operator in a safe environment. Gas Sniffer Probe To detect and locate the precise position of a gas leak in a pipe network or equipment. Smoke Index Smoke Index measurement can be obtained using a specia 1 heated probe, supplied on request, and through a dedicated internal procedure that computes the required volume of gas sample flowing into the specific filter. The results can be obtained by comparison with the Smoke Index Table.

Gas Velocity An internal procedure allows gas velocity measurements using the differential pressure inlet combined with a pitot tube. Report of Calibration Each instrument is factory calibrated and certified against Endee's Standard Gasses and shipped with a Report of Calibration stating the nominal and actual values and the deviation error. Quality System Research, development, production, inspection and certification activities are defined by methods and procedures of the Endee's System inspected for compliance and certified ISO 9001.

  • Complete Automatic operation Complete Automatic operation includinc Calibration, "ON - OFF" & "SAMPLE" Keys only.
  • Self diagnostic check Self diagnostic check & specific fault indication, Discrete LEDs for Sample Flow, Sensor Efficiency & Battery Condition.
  • Self-integrity Check Continuous on-line full self-integrity check eliminates wrong measurements due to Instrument Faults.
  • USER Friendly Visual Messages on status on functioning.
  • Proven Sensor Technology Special purpose long life Sensors with Cross Interference filters to achieve high accuracy.
  • Oxygen Sensor Guaranteed for 4 years.Display of Concentrations Continuous, Stable & Automation display of concentrations - ensures maximum accuracy & reliability.

Display High quality Alpha Numeric LCD.
Calibration Automatic Zero On Start with fresh air sample.
SPAN Calibration automatic with calibration gas.
Response Time Vlaximum 20 seconds at 95% variation
Power Supply Internal battery pack with external charger 220V/50 Hz
Working Temperature -5Deg.Cto 55Deg.C
Storage Temperature -20Deg.C to45Deg.C
Case Aluminum
External Dimension 170X100X130 mm
Weight 1.5 Kg
Probe(optional) (i) 8mm, Dia SS 600 mm length with 2 meter Hose Probes of other material & length available. 
(ii) Sniffer Probe : To detect & locate the precise position of Gas leak in a pipe network.
Accessories Leather case with shoulder strap, battery charger, operational manual.

View Complete Details

PROCESS-GAS-ANALYZER

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault",

  • Alarms for Low & High and Specific Fault
  • Specific Sensor as Per the Measuring Gas, Range & Application
  • Sample Conditioning System Offered As Per Application
  • Complete Automatic Operation
  • 16 Characters; 2 Line LCD Display Messages
  • Self Diagnostic Check Facility
  • A Mere Six Key to Operate the Complete Instrument

Sensor & sampling Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째 C
Enclosure Aluminium casing (power coated) for indoor application
Mounting Standard: 19" Rackmounted
Optional Flush on Panel/Tabletop
Warm uptime: Analysis Detectordependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, Conditioning system isrequired.
Calibration Manual, On command in microprocessor based system.
 
View Complete Details

Portable Flue Gas Analyzer

75,000 - 1.05 Lakh /Piece Get Latest Price
  • Driven Type Battery
  • Automation Grade Manual

We are offering portable flue gas analyzer.

sturdy stainless steel sampling probe with extension tubing for ease of measurement. Thermocouple in the tip of probe measures temperature at point of sampling to minimize error. Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure. Inline filter to inbuilt moisture & dust, disposable easy to replace filter element. Supervisory diagnostic circuit continuously checks it against choking. Retains the readings till the next sampling. Compact aluminum housing rechargeable ni-cad battery pack with charger. Maintenance & spare parts : designed for free maintenance operation. Long life sensor. Combustion efficiency is determined by oxygen content and temperature of fuel gases. An excess air (oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (oxygen) produces an incomplete I combustion with consequent higher costs and increased polluting emissions.

View Complete Details

FILED-MOUNTED-GAS-ANALYZER

The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser.

The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications changing the Measuring Parameters.

It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific Needs of Customer in Selection of Gases to Be Measured.

Optionally Lndee Ca 2000 Is Available With 1 lighly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault".

  • Alarms for Low & High and Specific Fault
  • Specific Sensor as Per the Measuring Gas, Range & Application
  • Sample Conditioning System Offered As Per Application
  • Complete Automatic Operation
  • 16 Charachters 2 line LCD Display messages
  • A Mere Six Key to Operate the Complete Instrument

Measuring Gas & Range Click Here
Sensor & sampling Gas Ranges & Application dependent.
Display Digital Standard LED optional alphanumeric display
Power Supply 100-290VAC/47-63HZ
Ambient Temp 0-50째C
Enclosure High Impact Plastic
Mounting FieldMounted
Optional Flushon Panel/Table top
Warm uptime Analysis Detector-dependent
Output(Optional) 4-20mA
Alarms Two Level (selectable range)
Sample Gas condition Temp:0-50째C, Pressure: Lessthan 1.5Kg/cm, The gas should be dry& clean. 
Other than this suitable sample, Conditioning system is required
Calibration Manual, On command in microprocessor based system.

View Complete Details

FLUE-GAS-ANALYZER

he Model 7001 is a Rugged, Portable, Easy-to-use Gas Analyser that monitors purge gases and the cooling gas in hydrogen-cooled turbine generators. It measures hydrogen in air & hydrogen in C02 as well as C02 in air during maintenance purging of hydrogen rooted turbine generators. Switch selectable ranges on the instrument make it easytochoosethe measurement required.

  • Fully integrated system Up to 7 gases in a single compact analyser
  • Wide measurement range
  • From 0 -100 PPM up to 0 -10, 000 PPM
  • Widely accepted, certified performance
  • Complies with the latest monitoring standards
  • Simple installation & maintenance
  • Requires no specialist skills or training,
  • all maintenance carried out on-site
  • Highest measurement perlumidnce
  • Ultra - low drift measurement technology
  • Measured Total NOx (NO+N02) Separate sensors for Lrue NOx monitoring,
  • Record and store vital emission data
  • Internal data logging function
  • Combustion efficiency measurement option
  • For a Optimization process efficiency where condition are changing

Technique Advanced Dual Sensor Technology
Optional Single Sensor Technology 
IR/UV Sensor Technology
Resolution 0-1 ppm (CO, NO, No2, & S02); 0.1% (Co2)
Linearity <2% of range
Zero drift <2% of range per month
Span drift <2% of range per month
02 Ranges 0-5 Vol% to 0-25 Vol%
Resolution 0.01 Vol%
Linearity <0.2 Vol%
Zero drift *0.2 Vol% per month
Span drift <0.2 Vol% per month
Calibration method Manual or Automatic 2-Point calibration span and zero automatic gas selection (option)
Display Type Alpha numeric LCD back light
Analogue outputs Isolated current loops One per gas 4-20 mA
Relays outputs One per gas
Relay rating Isolated changeover contacts rated 0.5A @ 125V a.c; V d.c
Communications RS 232 or R5 485 Modbus serial digital data bus (2 or 4 wire)
Enclosure 19" Rack
Operating Temp 40deg C to + 50deg C
Power consumption 400 w
Instrument air (0 calibration) 4 bar/ 60 psi min. clean dry & solvent free; 10 1/min
Calibration gas (recommended) 1 bar/15 psi; 2L/min approx
Calibration gas type Specific to each gas type & measurement span
Dimensions (H x W x D) < 20 seconds
Response Time 1570x600x370 mm
Options 24x24x12 mm

View Complete Details

Portable Gas Analyzer

  • Weight 390Gm (with battery)
Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.
View Complete Details
Tell Us What are you looking for? Will call you back