Our Products
Insulated Cable
2 Products availableTelecommunication Equipment & System
2 Products availableSubmersible Cables
1 Products availableTelecommunication Cable
1 Products availableWe are leaders in the market for providing best range of FRHR Cables, ZHFR Cables, FR Cables, Fire Retardant Cables and Energy Cables
International National | BS 6004, BS 6500, DIN VDE 0281-3IS 694, IEC 227 |
Conductor | Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking. |
Insulation | Specially formulated grade of PVC compound is capable of withstanding higher conductor temperatures with flame retardant properties. A rating of 105C with FR properties enables the cable to withstand overloads without compromising safety. The insulation is resistant to boiling water, steam and vapours to prevent aging and cracking in practical usage in kitchens, bathrooms, damp walls, chemical industries etc. |
Marking | The Cable are printed with generic marking ELKAY - FRHR |
Color | Skin colouring in various colour like Red, Yellow, Blue, Black, Green |
Packing | 90 mts. length in attractive cartoons. |
Size, Dimensions And Rating
Normal Area of Conductor | Number/ Nom. Dia. | Number/ Nom. Dia. For Unilay | Insulation Thickness (Nom.) | Approx. Overall Diameter | Current Carrying Amps. | Current Carrying Amps. | Resistance (Max.) per km |
---|---|---|---|---|---|---|---|
Sq.mm. | mm. | mm. | mm. | mm. | Concealed | Casing | @ 200C Ohms. |
1.0 | 14/.3 | 19/0.26 | 0.7 | 2.8 | 11 | 12 | 18.10 |
1.5 | 22/.3 | 19/0.32 | 0.7 | 3.1 | 13 | 16 | 12.10 |
2.5 | 36/.3 | 37/0.29 | 0.8 | 3.8 | 18 | 22 | 7.41 |
4.0 | 56/.3 | 37/0.37 | 0.8 | 4.4 | 24 | 29 | 4.61 |
6.0 | 84/.3 | 61/0.35 | 0.8 | 5.0 | 31 | 37 | 3.30 |
International National | BS 4066-1 & 3, BS 6724, VDE 0207IEC 332-1 & 3, IEC 754-1 IEC 227 |
Conductor | Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking. |
Insulation | Specially formulated grade of Halogen Free Flame Retardant compound is used. The performance of the Cable in fire situation is exceptionally good. The insulation does not melt, drip or spread the fire conditions. The smoke is negligible, transparent and non-toxic. |
Marking | The Cable are printed with generic marking ELKAY - ZHFR |
Color | Skin colouring in various colour like Red, Yellow, Blue, Black, Green |
Packing | 90/100 mts. length in attractive cartoons. |
Flame Retardant PVC Insulated Sheathed 3 Core Flat Submersible Cables For Working Voltage up to 1100 Volts Reference Standards | |
International National | BS 6500, BS 6004, DIN VDE 0281 IEC 227, IS 694 |
---|---|
Conductor | Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking. |
Insulation | The insulation with a special grade of PVC and outer sheath consists of a highly abrasion resistant PVC compound. |
Marking | The Cable are printed with generic marking ELKAY - Submersible |
Core Colour | Red, Yellow, Blue |
Packing | 100 mts Coils & 500 mts Drums |
Sizes, Dimensions And Rating
Normal Area of Conductor | Construction Size & Item | Insulation Thickness (Nom.) | PVC Outer Sheath (Nom) | Approx. Overall Dimension (WXT) | Current Carrying Capacity @ 400C | Resistance (Max.) per km |
---|---|---|---|---|---|---|
Sq.mm. | mm. | mm. | mm. | mm. | Amp. | @ 200C Ohms. |
1.5 | 22/.3 | 0.8 | 1.2 | 11.9 x 5.5 | 14 | 12.10 |
2.5 | 36/.3 | 0.9 | 1.2 | 13.85 x 6.15 | 18 | 7.41 |
4.0 | 56/.3 | 1.0 | 1.2 | 18.8 x 6.8 | 26 | 4.95 |
6.0 | 84/.3 | 1.0 | 1.2 | 17.3 x 7.3 | 31 | 3.30 |
10.0 | 140/.3 | 1.0 | 1.4 | 20.5 x 8.7 | 42 | 1.91 |
16.0 | 226/.3 | 1.0 | 1.4 | 23.65 x 9.75 | 57 | 1.21 |
25.0 | 354/.3 | 1.2 | 2.0 | 30 x 12.65 | 72 | 0.78 |
35.0 | 495/.3 | 1.2 | 2.0 | 33.7 x 13.9 | 90 | 0.554 |
50.0 | 703/.3 | 1.4 | 2.0 | 40.7 x 16.5 | 105 | 0.386 |
Typical Applications 3 Core flat cable are suitable for submerible pumps. |
International National | BS 6004, BS 6500, DIN VDE 0281-3 IS 694, IEC 227 |
Conductor | Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking. |
Insulation | Specially formulated grade of PVC compound is capable of withstanding higher conductor temperatures with flame retardant properties. A rating of 105C with FR properties enables the cable to withstand overloads without compromising safety. The insulation is resistant to boiling water, steam and vapours to prevent aging and cracking in practical usage in kitchens, bathrooms, damp walls, chemical industries etc. |
Marking | The Cable are printed with generic marking ELKAY - FRHR |
Color | Skin colouring in various colour like Red, Yellow, Blue, Black, Green |
Packing | 90 mts. length in attractive cartoons. |
Size, Dimensions And Rating
Normal Area of Conductor | Number/ Nom. Dia. | Number/ Nom. Dia. For Unilay | Insulation Thickness (Nom.) | Approx. Overall Diameter | Current Carrying Amps. | Current Carrying Amps. | Resistance (Max.) per km |
---|---|---|---|---|---|---|---|
Sq.mm. | mm. | mm. | mm. | mm. | Concealed | Casing | @ 20C Ohms. |
1.0 | 14/.3 | 19/0.26 | 0.7 | 2.8 | 11 | 12 | 18.10 |
1.5 | 22/.3 | 19/0.32 | 0.7 | 3.1 | 13 | 16 | 12.10 |
2.5 | 36/.3 | 37/0.29 | 0.8 | 3.8 | 18 | 22 | 7.41 |
4.0 | 56/.3 | 37/0.37 | 0.8 | 4.4 | 24 | 29 | 4.61 |
6.0 | 84/.3 | 61/0.35 | 0.8 | 5.0 | 31 | 37 | 3.30 |
Additional Properties
Test | Specification | FRPVC Typical Value | Ordinary PVC |
---|---|---|---|
Critical Oxygen Index | ASTM-D 2863 | >29 | >22 |
Temperature Index | ASTM-D 2863 & BICC Hand Book Chapter No. 6 | >2500C | >2000C |
Smoke Density | ASTM-D 2843 | <80% | <90% |
Acid Gas Generation | IEC 754-1 | <20% | <40% |
Flammability | IEC 332-1 | Flame to extinguish with in 30 sec. | Flame to extinguish with in 60 sec. |
Telephone Cables - Indoor/outdoor
Reference Standards | |
International National | CW 1044, CW 1109, CW1293, CW 1308, CW 1311, CW 1316, CW 1600, Elaky, IEC 189 IS 13176, S/WS 1130, S/WS 1148, G/WIR - 06/02 |
---|---|
Conductor | Electrolytic Copper Bare/tinned. |
Sizes | 0.4 MM/ 0.5 MM/ 0.6 MM/0.63 MM/ 0.71 MM/ 0.8 MM/ 0.9 MM SOLID. |
Insulation | A. Pvc Suitable for 700C/850C Operation. B. Medium/high Density Polyethylene. |
Formation | Multipair. |
Binder Tape | Polyster/PVC. |
Screening | Aluminium Mylar Tape with 100% Coverage (optional). |
Armour | G.I. Wire/strip as per Is: 3975 (optional) Alongwith Drain Wire. |
Inner/outer Sheath | PVC/Polyethylene/FRLS PVC. |
Instrumentation Cables-225/600/1100 V Grade
| |||||||||||||||||||||||||
Description | Cond. Size mm | Ins. Thickness mm | Alum. Mylar mm | Thickness of Sheath mm | External Diameter mm | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 0.80 | 7.10 | ||||||||||||||||||||
4Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 0.90 | 8.40 | ||||||||||||||||||||
7Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 1.10 | 10.20 | ||||||||||||||||||||
10Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 1.20 | 12.90 | ||||||||||||||||||||
16Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 1.20 | 14.60 | ||||||||||||||||||||
19Cx1.0 SQ.MM | 7/0.42 | 0.60 | 0.062 | 1.20 | 15.40 |
Multipair Screened Instrumentation Cable - Unarmoured
Description | Cond. Size mm | Ins. Thickness mm | Alum. Mylar mm | Thickness of Sheath mm | External Diameter mm |
---|---|---|---|---|---|
1P x 1.5 SQ.MM | 7/0.52 | 0.60 | 0.062 | 0.80 | 10.50 |
2P x 1.5 SQ.MM | 7/0.52 | 0.60 | 0.062 | 0.90 | 14.80 |
6P x 1.5 SQ.MM | 7/0.52 | 0.60 | 0.062 | 1.20 | 17.50 |
12Px1.5 SQ.MM | 7/0.52 | 0.60 | 0.062 | 1.3 | 22.00 |
Copper/aluminium Cables - 1100 V Grade | |
Reference Standards | IS 694, IS 7098, BS 6004, BS 6500 |
---|---|
Conductor | Electrolytic Copper Bare/tinned |
Sizes | 1.0 SQ.MM UPTO 630 SQ.MM |
Formation | Multistranded Conductor - Class 2, Class 5 |
Inulation | A. P.V.C Suitable for 700C/850C/1250C Operation. B. XLPE Insulation for 900/1250 Operation C. Low Halogen Low Smoke Specially Formulated Polymer. |
S.NO. | CROSS SECTIONAL AREA OF COND. | NOMIANL INS. THICKNESS | OVERALL DIA | MAXIMUM RESISTANCE CONDUCTOR AT 200C OHMS/KM | MAXIMUM RESISTANCE CONDUCTOR AT 200C OHMS/KM |
---|---|---|---|---|---|
SQ.MM | MM | MAX.MM | ABC | ATC | |
1 | 1 | 0.7 | 3.2 | 19.5 | 20.0 |
2 | 1.5 | 0.7 | 3.4 | 13.3 | 13.7 |
3 | 2.5 | 0.8 | 4.2 | 7.98 | 8.21 |
4 | 4 | 0.8 | 4.8 | 4.95 | 5.09 |
5 | 6 | 0.8 | 5.6 | 3.30 | 3.39 |
6 | 10 | 1.0 | 7.0 | 1.91 | 1.95 |
7 | 16 | 1.0 | 8.2 | 1.21 | 1.24 |
8 | 25 | 1.2 | 10.0 | 0.780 | 0.795 |
9 | 35 | 1.2 | 11.5 | 0.554 | 0.565 |
10 | 50 | 1.4 | 13.0 | 0.386 | 0.393 |
11 | 70 | 1.6 | 15.0 | 0.272 | 0.277 |
12 | 95 | 1.6 | 17.5 | 0.206 | 0.210 |
13 | 120 | 1.8 | 19.0 | 0.161 | 0.164 |
14 | 150 | 2.0 | 21.0 | 0.129 | 0.132 |
15 | 185 | 2.2 | 23.5 | 0.106 | 0.108 |
16 | 240 | 2.4 | 26.5 | 0.0801 | 0.0817 |
17 | 300 | 2.6 | 29.5 | 0.0641 | 0.0654 |
18 | 400 | 2.8 | 33.5 | 0.0486 | 0.0495 |
19 | 500 | 2.8 | 37.5 | 0.0384 | 0.0391 |
20 | 630 | 2.8 | 42.0 | 0.0287 | 0.0292 |