Post Buy Requirement

Electrical Cables & Wires

Our offered Product range includes Thermocouple Extension Cables, Flexible Cables, Fire Resistant Cables, Aerial Cables and flat flexible cables.

Thermocouple Extension Cables

We are listed at the apex in the list of the most dependable Thermocouple Extension Cables Exporters from India. The use of optimum quality materials in the manufacturing of the Multipair Thermocouple Extension Cable ensures notable features like high durability and resistance to weathering conditions. Customers from every nook and corner of the world are placing bulk orders for the Thermocouple Extension Grade Cable due to the unmatched quality and inexplicable performance in respective applications. Customers are also eased with the availability of the Thermocouple Extension Cables in varied dimensions as per the specifications provided.

International
National
BS 5308, ANSI MC 96 1
IS 8784, IS 6720, IS 2054, IS 2055, IS 2056, IS 5831, IS 1554
ConductorSpecial Alloys.
InsulationA. Pvc Suitable for 700C/850C Operation
B. Medium/ High Density Polyethylene
FormationMultipair (upto 24 Pair)
ScreeningIndividual and Overall
A. Aluminium Mylar with 100% Coverage & 20% Overlap
B. Braiding with 0.15/0.2/0.3mm Atc Electrolytic Tinned Copper
Drain WireAtc of Suitable Dia Alongwith Metallic Side of Screen.
ArmourG.I. Wire/strip as per Is: 3975 (optional)
Inner/outer SheathPVC/FRLS, PVC/Low Halogen Very Low Smoke Polymer
Special TestsL/R Ratio, Thermo Emf Character, Loop Resistance, Capacitance.





View Complete Details

Flexible Cables

We are reckoned as one of the most dependable Highly Flexible Cables Exporters from India. The unmatched quality and inexplicable performance has attracted various national as well as international clients to place bulk orders for the Flexible Cables. The use of optimum quality materials in the manufacturing of the Flexible Power Cables ensures notable features like high durability and flexibility. Additionally, customers are eased with the availability of the Flat Flexible Cables in varied dimensions as per the specifications provided. Technical Data
  • Single Core Conduit Cables: Solid or stranded plain copper conductor, PVC insulated Single Core Double Insulated Cables/Twin and Earthed Cables/Three Core and Earthed Cables: Solid and Stranded, plain copper conductor.
  • Normal Duty Flexible Cords: Flat twin, Circular twin, Circular 3 core, Circular 4 core.
  • Light Flexible Core: Flat twin, Circular twin, Circular 3 core, Circular 4 core, plain copper flexible conductor, PVC insulated, PVC sheathed.
  • Reference Standards : BS 6500, IS 694

Nominal Cross (sq.mm.)Min. Dia. of wires Radial Thickness
Insulation (mm)
Radial Thickness
Sheath (mm)
Overall Diameter
0.5 x 2C0.210.60.87.0
0.75 x 2C0.210.60.87.6
1.0 x 2C0.210.60.88.0
1.5 x 2C0.260.70.89.0
2.5 x 2C0.260.81.011.0
0.75 x 3C0.210.60.88.0
1.0 x 3C0.210.60.88.4
1.5 x 3C0.260.70.99.8
2.5 x 3C0.260.81.112.0
0.75 x 4C0.210.60.88.6
1.0 x 4C0.210.60.99.4
1.5 x 4C0.260.71.011.0
2.5 x 4C0.260.81.113.0


View Complete Details

Fire Resistant Cables

We are listed at the apex in the list of the most dependable Fire Resistant Cables Exporters from India. Various national as well as international clients are placing bulk orders for the Fire Resistant Power Cables due to the unmatched quality and unsurpassable performance in respective applications. Additionally, customers are eased with the availability of the Fire Resistant Data Cables in varied sizes and dimensions as per the specifications provided. The Insulated Fire Resistant Cables that comply with the international standards. Suitable for petrochemical industry, this cable is designed to connect electrical insruments circuits and provide communication services in and around process plants. These cables are essential to maintain circuit integrity when exposed to fire and where life may be endangered by smoke & noxious fumes and where sensitive equipment may be damaged by acid forming gases. Generally in accordance with BS 5308, but with the addition of fire properties relevant to IEC 60331.
  • Conductor: Stranded (class2) copper conductors to BS 6360.
  • Insulation: Mica/glass tape, XPLE, FRZN
  • Pairs/Triplets Identification: These cables are colours coded in accordance with BS 5308 part 2. Tape: Mylar tape with overlap
  • Collective Screen: Tinned copper drain wire(s) under and in contact with Aluminium Mylar tape applied metallic side down.
  • Inner Sheath: FRZH
  • Armour: Mild galvanised steel wires/Flat strip
  • Outer Sheath: FRZH
  • Fire Characteristics: Fire resistant to IEC 60331 (750C for 3 hours)
  • Temperature Rating: 80C maximum conductor operating temperature.
  • Voltage Rating: 300/500 volts.

BS 5308 Part 1 Type2 - FRZH And Fire Resistant

Number of Pairs/ TriplesNominal Conductor Area sq.mm.Nominal Conductor Stranding #/mmInsulation Thickness mmNominal Diameter Under Armour mmArmour Wire Diameter mmOverall Nominal Diameter mm
1P1.57/0.530.608.70.913.3
2P(Q)1.57/0.530.6010.10.914.7
6P1.57/0.530.6017.71.620.9
12P1.57/0.530.6024.01.631.0
1T1.57/0.530.609.20.913.8
1P2.57/0.670.7010.00.914.6
2 (Q)2.57/0.670.7011.80.91.6
6P2.57/0.670.7020.91.627.7
Q-Quad These cables are also available in individually and collectively screened versions upto 7 quad of 1.0/1.5 sq. mm, of which details can be supplied upon request.
View Complete Details

Aerial Cables

We are listed at the top in the list of the trusted Aerial Cables Manufacturers in India. The materials used in the manufacturing of the Aerial Bunched Cables are of optimum quality that ensures excellent performance in respective applications. The Telecom Aerial Cables are also available in varied specifications that comply with the international norms. Customers are also eased with the availability of the Insulated Aerial Cables packed in reliable packs. Reference Standards - CW 1252 & 52-23 / 85 - TRC

Sizes Covered

0.5 mmUpto 100 pair
0.63 mmUpto 50 pair
0.9 mmUpto 20 pair
Cable Construction
Aerial Cables
Conductor Solid Annealed Bare Copper
Insulation Solid Polyethylene, coloured as per specification
Units 10/20 Pairs shall be laid up to form a unit
Super Unit 5 units of 10p/20p laid up to form a super unit of 50p/l00p
Cable Core Laying 10p/20p units/50p/100p super units laid up to form a Cable Core
Jelly Filling Not Applicable
Polyester Taping Polyester tape applied longitudinally/helically over the laid up core/cable
Screening PolyAl. tape applied longitudinally over polyester tape with overlap
Self Suspension wires/strand Galvanized steel wires as per specification
Sheathing Not Applicable
Bedding Not Applicable
Armouring Not Applicable
Jacketing Polyethylene applies over cable core & suspension strand in the form of 8

CW1252 These cables are self-supporting for aerial installations. Construction as per CW 1128 with the inclusion of an integral steel support strands or caternary. The cross section of these cables resembles a figure of eight.
No.of PairsConductor Size (mm)No. & Normal Dia. of Strands (mm)Max. Overall Dia.(mm)Nominal Weight (kg/km)
50.51/2.658.1125
100.51/2.659.0150
200.57/1.611.1210
300.57/1.613.0350
500.57/1.615.6470
1000.57/1.620.4740
View Complete Details