Post Buy Requirement

Products / Services

Aerial Bunched Cables

  • Type Bunched
  • Conductor Material Copper
  • Insulation Material Rubber
  • Conductor Type Standard
  • Jacket PVC
  • Voltage 200-400 Volts

In the ABC system, the insulated aluminum conductors (3 or 4 numbers as required) are twisted around a high strength aluminum alloy bearer wire which covers the main weight and also serves as the earth cum neutral wire.
The phase conductor is not under tension. Due to theft prevention, heights of pole elimination of insulator and associated hardware and the possibility of using small sizes of phase conductors like 16 sq. mm in certain location the overall cost of the ABC lines is practically the same as in conventional overhead lines.
Our AB cables are manufactured as per national and international specifications and as per customer requirements. Due to various customers’ requirements the composition and designation of cables are different. Some designations are given on left side of the table mentioned below.
The first part of the designation refers to the numbers and size of the phase conductor, the middle to the street light conductor (where provided) and last to the bare messenger wire. The sizes shown are the nominal cross sectional areas.

Specification

S. No. Nominal Cross Sectional area of phase Conductor mm2 Nominal Cross Sectional area mm2 Maximum dc Resistance at 200C kn Minimum Breaking Load Kn
1 16 25 1.38 7
2 25 25 1.38 7
3 35 25 1.38 7
4 50 35 0.99 9.8
5 70 50 0.69 14
6 95 70 0.49 19.7

Specification

S. No. Designation
1 1 x 16+25
2 2 x 16+25
3 3 x 16+16+25
4 1 x 25+25
5 3 x 25+16+25
6 3 x 35+25
7 3 x 35+16+25
8 3 x 50+16+35
9 3 x 70+16+50
10 3 x 95+16+70
View Complete Details

Aluminium Steel Reinforced Conductor

  • Type Reinforced
  • Conductor Material Aluminium
  • Insulation Material Rubber
  • Jacket PVC
  • Color Silver
  • Voltage 320 Volts

The mixed construction of ACSR makes it a very flexible medium from a design point of view in Electrical Transmission & Distribution.
By varying the relative proportion of aluminum and steel the ideal conductor for any particular application can be produced. Generally, ACSR consists of galvanized steel core 1 wire or 7 wires or 19 wires surrounded by concentric layer of aluminum wires.
Construction ratio of aluminum and steel varies with requirement of current carrying capacity. We manufacture ACSR conductors considering National and International standards.

Specification

Code Word Nominal Aluminium Area Stranding & Wire dia Sectional Area Total Sectional Area Approx. Overall Diameter Approx. Weight Calculated Resistance At 200C Approx. Calculated breaking Load
Sq. mm No./mm Sq. mm Sq. mm mm Kg/km Ohm/km KN
Alum. Steel Total Alum. Steel
Mole 10 06/01/50 01/01/50 10.6 12.37 4.5 43 29 14 2.78 3.97
Spl. Conductor 18 06/01/96 01/01/96 18.1 21.12 5.88 73 50 23 1.62 6.74
Squirrel 20 05/02/11 01/02/11 20.98 24.48 6.33 85 58 27 1.39 7.61
Weasel 30 06/02/59 01/02/59 31.61 36.88 7.77 128 87 41 0.93 11.12
Rabbit 50 06/03/35 01/03/35 52.88 61.7 10.05 214 145 69 0.55 18.25
Raccoon 80 06/04/09 01/04/09 78.83 91.97 12.27 319 217 102 0.37 26.91
Dog 100 06/04/72 07/01/57 105 118.5 14.15 394 288 106 0.28 32.41
Wolf 150 30/2.59 07/02/59 158.1 194.9 18.13 726 438 288 0.19 67.34
Panther 200 30/3.00 07/03/00 212.1 261.5 21 974 587 387 0.14 89.67
Kundah 400 42/3.50 07/01/96 404.1 424.2 26.88 1281 1120 161 0.07 88.79
Zebra 420 03/18/54 07/03/18 428.9 484.5 28.62 1621 1187 434 0.07 130.32
Moose 520 04/13/54 07/03/53 528.5 597 31.77 1998 1465 539 0.06 159.6
Markulla 560 04/13/42 07/02/30 562.7 591.7 31.68 1781 1559 228 0.05 120.16
Bersimis 690 42/4.57 07/02/54 688.9 724.4 35.04 2187 1907 280 0.42 146.87
View Complete Details

Aluminium Alloy Conductor

  • Type Shielded
  • Material Aluminium
  • Number of Conductors 5
  • Jacket PVC
  • Color Silver
  • Voltage 220 V

These Aluminium Alloy Conductors are heat treated magnesium silicon type. The Alloy ref erred to have higher strength but lower conductivity than pure aluminum.
Being lighter, alloy conductors can sometimes be used to advantage in place of the conventional ACSR conductors. Their use becomes favorable when ice and wind loadings are low.
We manufacture Aluminium Alloy Conductors as per National and International standards and also as per specifications and requirements of customers.

Specification

Actual Area Stranding & Wire Dia Approx. Overall Dia Approx. Mass Calculated Resistance at 200C (Max.) Approx. Calculated Breaking Load
Sq. mm Nos./mm mm Kg/km Ohm/km KN
15 03/02/50 5.39 40.15 2.3 4.33
22 07/02/00 6 60.15 1.54 6.45
34 07/02/50 7.5 94 0.99 10.11
55 07/03/15 9.45 149.2 0.62 15.03
80 07/03/81 11.43 218.26 0.43 23.41
100 07/04/26 12.78 272.86 0.34 29.26
125 19/2.89 14.45 342.51 0.27 36.34
148 19/3.15 15.75 406.91 0.23 43.5
173 19/3.40 17 474.02 0.2 50.54
200 19/3.66 18.3 549.4 0.17 5866
232 19/3.94 19.7 636.67 0.15 68.05
288 03/15/37 22.05 794.05 0.12 64.71
346 37/3.45 24.15 952.56 0.1 101.58
400 37/3.71 25.97 1101.63 0.08 117.4
465 37/4.00 28 1280.5 0.07 136.38
525 03/31/61 29.79 1448.39 0.07 146.03
570 61/3.45 31.05 1573.71 0.06 158.66
604 61/3.55 31.95 1666 0.06 167.99
642 61/3.66 32.94 1771.36 0.05 178.43
695 61/3.81 34.29 1919.13 0.05 193.25
767 61/4.00 36 2115.54 0.04 213.01
View Complete Details

Multi Core Flexible Cable

  • Type Flexible
  • Material Copper, PVC
  • Thickness 0.5-1mm, 1.5-2mm
  • Voltage 110V
  • Application Home, Industrial
  • Feature Crack Free, High Ductility, High Tensile Strength
View Complete Details

LT XLPE Control Cable

  • Product Type XLPE Cables
  • Conductor Solid or stranded copper
  • Insulation Cross-linked polyethylene( XLPE or PVC)
  • Inner Sheath Polyvinyl chloride (Black)
  • Armor Galvanized steel wire
  • Core-covering Binding tape
  • Outer Sheath Polyvinyl chloride (Black)
  • Voltage: 1.8/3KV
View Complete Details

HT XLPE Control Cable

  • Voltage 220-400 Volts
  • conductor Annealed Bare Electrolytic Copper / Aluminum Conductor conforming to IS:8130:1984
  • Insulation Conductor are insulated with PVC Compound as per IS:5831:1984
  • Material PVC
  • Type Flexible
  • Cable Length 1.5 meter
  • Size 1 sq.mm to 16 sq.mm
View Complete Details

LT PVC Power Cable

  • Type Power Cable
  • Application Underground Applications & Over Head
  • Conductor Material Copper
  • Insulation Material PVC
  • Rated Voltage 220V - 250V
  • Cable Size 90 meter
  • Use Domestic and Commercial
View Complete Details

Single Core Switchgear Wire

  • Type Housing Wires
  • Jacket PVC/EPR
  • Application For House Wiring & Panel Wiring
  • Voltage 650/1100V
  • Conductor Type Flexible Copper
View Complete Details

Substation Erection Services

Between the generating station and consumer, electric power travels through several substations at different voltage levels. These substations are used for stepping up & stepping down the voltage and perform several other important functions. If you are looking for a dependable entity that can undertake your substation erection requirements, then you have landed on the right webpage. We, NIIL based in Indore (Madhya Pradesh, India), have been providing substation erection services since 2009. The company has all the modern resources and techniques to design, plan, estimate and develop the undertaken substation erection work.

View Complete Details

Substation Augmentation Services

The main purpose of a substation is to step down the high voltage electricity so it can be easily supplied to homes and businesses through the distribution lines. And, we are providing substation augmentation services from Indore (Madhya Pradesh, India). Active since 2009, we have been providing effective solutions to meet the client’s requirements. Whether you want to augment the substation in a hilly terrain or in a plain area, we have enough resources to fulfil your requirements with utmost precision. So, contact us anytime.

View Complete Details

Aluminium Conductor

  • Type Shielded
  • Conductor Material Aluminium
  • Insulation Material Rubber
  • Color Silver
  • Voltage 220 V
  • Conductor Type High Voltage

Owing to our rich experience and vast knowledge of this domain, we have been able to offer premium quality AAC Conductor to our valuable customers.
These AAC are offered by us at industry set norms. AAC has been in extensive use in urban areas where spaces are usually short but high conductivity is required.
Due to our rich distribution network, we have been able to deliver these conductors within the assured time frame at the customers’ end.

Specification

Code Word Nominal Aluminium Area Standing & Wire dia Sectional Area Approx. Overall Diameter Approx. Weight Approx. Calculated Breaking load Calculated Resistance at 200C (max)
Sq. mm No./mm Sq. mm mm Kg/mm Kn Ohm/km
Gnat 25 07/02/21 26.85 6.63 74 4.52 1.1
Ant 50 07/03/10 52.83 9.3 145 8.25 0.55
Wasp 100 07/04/39 106 13.17 290 15.96 0.28
Spl. Conductor 150 19/3.18 150.9 15.9 415 23.28 0.19
Spider 240 19/3.99 237.6 19.95 654 35.74 0.12
Butterfly 300 19/4.65 322.7 23.25 888 48.74 0.09
View Complete Details

Building PVC Wire

  • Type Wires
  • Application Industrial Realted
  • Material PVC
  • Wire Gauge 13 NO
  • Colors Available in different colors
  • Flame Retardant Yes
  • Voltage 1100V
View Complete Details

Submersible Flat Cable

  • Voltage 1000 V
  • Conductor Material Copper
  • Insulation Material Pvc
  • Conductor Type Solid and stranded
  • AC Voltage Rating: 0.6/1kv
  • Size 4 mm
View Complete Details
Tell Us What are you looking for? Will call you back