Our offered Product range includes RAPUSH BUTTON STATION, Earthing Material and support systems.

Gi Perforated Cable Tray

  • thicknesses 1.2 mm, 1.5 mm, 1.6 mm, 2.0 mm
ELCON is the leading in manufacturing perforated and ladder - type trays with accessories. Cable Trays are available in different sizes as per the customer specifications. We manufacture cable trays in the following thicknesses - 1.2 mm, 1.5 mm, 1.6 mm, 2.0 mm, 2.5 mm, and 3.0 mm. & width - 50 mm to 1000 mm, cable trays are available in different finishes like MS, Hot dip galvanized, powder coated, painted etc. The cable tray accessories for perforated ladder type cable trays are vertical bends, horizontal bends, inside bends, outside bends, reducers with radius 300, 600, 900 are avaialble.
View Complete Details

Junction Box

  • MECHANICAL DATA Material
  • Aluminium LM6 Weight
  • Refer the Dimension Chart IP Protection
  • IP 65 Finish
  • Anti corrosive Epoxy powder coated Cable Entry
  • Refer Chart. Canopy
  • Optional Cover Fixing
  • Threaded, Spigotted Hinge
  • Stainless Steel (Optional) Gasket
  • Neoprene Hardware

DESCRIPTION

Explosion proof junction boxes with threaded or spigotted covers. Available in six sizes, these boxes provide a wide range of terminations and distribution facilities. Integrally cast plates are provided for different combinations and cable entries on any of the four sides. Weatherproof protection is provided by high quality neoprene 'O' ring gaskets.

View Complete Details

RACEWAY DUCTS

  • STRENGTH Light Duty, Medium Duty & Heavy Duty
  • WIDTH (W) 50 mm to 600 mm
  • HEIGHT (H) 25 mm to 150 mm
  • THICKNESS (T) 1.2 mm, 1.6 mm, 2mm2.5 mm & 3 mm
  • FLANG HEIGHT (FH) 10 mm to 25 mm
  • INWARD BLEND (IB) 15 mm to 20 mm
  • LENGTH(L) 2500 mm / 3000 mm & 2444 mm (for Aluminum)
View Complete Details

RAPUSH BUTTON STATION

  • IP Protection IP 65
  • Finish Anti corrosive Epoxy powder coated
  • Cable Entry Depend on specs
  • Gasket Neoprene
  • Hardware Stainless Steel
  • Canopy Stainless Steel
DESCRIPTION
Where several control & indication functions in a hazardous area are required to be operated from one location, they can all be mounted in an Explosion proof Control Station. Control Stations are available with up to three separate enclosures for housing various control units and a separate integral terminal chamber. The clipon type terminals provided in the chamber are pre-wide to the control units through sealed cable bushes. A wide variety of control units can be selected for mounting into the enclosures. The control stations are also fitted with high quality neoprene gaskets to ensure weather proof protection.
View Complete Details

SS TUBE AND FITTING

ELCON TUBE FITTINGScome to you completely assembled, finger-tight. They are ready for immediate use. Dis-assembly before use can result in dirt or foreign material getting into the fitting and causing leaks

ELCON TUBE FITTING are installed in three easy steps.

Insert the tubing into the ELCON TUBE FITTING. Make sure that the tubing rests firmly on the shoulders ofthe fitting and that the nut is snug tight, in this position the tube does not rotate by hand.
Before tightening the ELCON nut, scribe the nut atthe 6.00 o'clock position.
Now while holding the fitting body steady with a backup wrench, tighten the nut one-and-one quarter turns* Watch the scribe mark, make one complete revolution and continue to the 9.00 o'clock position. *For 1/8", 3/16", 3 & 4 mm size tube fittings, only % turns from finger-tight is necessary the joint is now complete.
HIGH PRESSURE APPLICATIONS, HIGH SAFETY FACTOR SYSTEMSDue to the variation of tubing diameters, a common starting point is desirable. Therefore, use a wrench to snug up the nut until the tubing will not turn (by hand) in the fitting. Now tighten the nut one-and-onequarter turns and the fitting is ready to hold pressure well above the working pressure of the tubing.
RE-TIGHTENING INSTRUCTIONSDue to the variation of tubing diameters, a common starting point is desirable. Therefore, use a wrench to snug up the nut until the tubing will not turn (by hand) in the fitting. Now tighten the nut one-and-onequarter turns and the fitting is ready to hold pressure well above the working pressure of the tubing.
THREAD SPECIFICATIONSELCON connectors have one or more tubing end connections and the others with male or female pipe threads there are a variety of pipe threads for which ELCON Double Ferrule Fittings are available. The most popular thread connections are the American National Pipe thread (NPT) British standard pipe threads (BSP) and metric threads. These threads belong to standards of individual countries as well as iso where they have been codified All ELCON Fittings with pipe threads or stud end threads conforming to the specifications as detailed bellow
  • American National Pipe Thread (NPT) : reference specification ASA B2. 1: 1960ISO parallel pipe threao ( British standard pipe thread ) :Reference specifications BS 2779. ISO 228/1 DIN 259.JISB 0202.IS 2643
  • ISO taper pipe thread (British standard pipe taper thread )
  • Unified National pipe threads: Reference specifications ASA B1 1: 1964
View Complete Details

Copper Tube Fitting

We give below the specification to be followed for the various tunings for use with ELCON Double Ferrule Compression Fitting.Soft , annealed carbon steel hydraulic tubing to ASTM A 179, Din 2391 or equivalent based on ultimate tensile strength of 47000 psi and for metal temperatures not to exceed 20 deg C to 100 deg C. For higher temperature service, reducing factors for elevated temperature operation as specified in table 302.3 1A and 304.1.2 of the code for pressure piping in ANSI B 31.3 should be applied. The hardness of the tube is recommended to RB 7xThe hardness of the tube is recommended to RB 72 OR less. The Tubes should be suitable for bending and flaring and free of surface defects and imperfections

Annealed 304 or 316 Stainless Steel tubing to ASTM A 269 or A 213 or equivalent based on ultimate tensile strength of 75, 000 psi and suitable for temperatures 20deg C to 100 deg C.The hardness of these tubes is not to exceed RB 80 and is preferred in the range RB 70 74.Tubes to be suitable for bending and flaring and should be free o0f surface defact and imperfections.
Annealed 304 or 316 Stainless copper tubing to ASTM B 75 or ASTM B 88 based on an ultimate tensile strength of 30, 000 psi and for a temperature in the range of 20 deg C to 80 deg C Maximum hardness of the tube not to exceed RB 50. Tubes preferred in the range RB 40-45
Fully annealed Monel 400 seamless tubing conforming ASTM B165 or equvaient and based on dftimata tensile strength of 70.000 psi and for use with temperatures 20 deg C to 90 deg C.Hardness of the tube must be RB 75 maximum and is preferred in the range RB 68 72These tubes should be suitable for blending and flaring and free from all surface defects and imperfections
View Complete Details

Cable Tray System

  • STRENGTH Light Duty, Medium Duty & Heavy Duty
  • WIDTH (W) 50 mm to 1200 mm
  • HEIGHT (H) 25 mm to 100 mm
  • THICKNESS (T) 1.2 mm, 1.6 mm, 2mm2.5 mm & 3 mm
  • INWARD BEND (IB) 10 mm to 25 mm
  • LENGTH (L) 2500 mm / 3000 mm & 2444 mm (for Aluminum)

ELCON is the leading in manufacturing perforated and ladder type cable trays with accessories. Cable Trays are available in different sizes as per the customer specification. we manufactures cable trays in the following thicknesses - 1.2mm, 1.5mm, 1.6mm, 2mm, 2.5mm and 3mm, length- 2.5m, 3m and width - 50mm to 1000mmcable trays are available in different finishes like MS, Hot dip galvanized, pre-galvanized, powder coated, painted etc. The cable tray accessories for perforated ladder type cable trays are vertical bends, horizontal bends, inside bends, outside bends, reducers and tees with radians 300, 600, 900 are available.

ADVANTAGES OF ELCON CABLE TRAY

  • Cost Saving
  • Design Cost Savings
  • Dependability
  • Installation Cost & Time Saving
  • Material Savings
  • Maintenance Savings
  • Space Savings

STRENGTH Light Duty, Medium Duty & Heavy Duty
WIDTH (W) 50 mm to 1200 mm
SIDE CHANNEL HEIGHT (H) 50 mm to 150 mm
RUN WIDTH 30 mm to 50 mm
RUN HEIGHT 10 mm to 20 mm
RUN C TO C 25 mm to 100 mm
THICKNESS (T) 1.2 mm, 1.6 mm,2mm2.5 mm & 3 mm
BEND (TB) 10 mm to 25 mm
LENGTH (L) 2500 mm / 3000 mm & 2444 mm

 

FINISH SPECIFICATION RECOMMENDED USE
Painted As per Specification Indoor
Powder Coated As per Specification Indoor
Pre Galvanized As per Specification Indoor
Hot Dip Galvanized As per is 4759, 2629, 2633 Indoor / Outdoor

   

View Complete Details

CABLE TERMINAL AND LUGS

Entire ranges of copper tubular terminals are made from ETP grade & EC grade aluminum tubes. Terminals are exclusively designed for study performance even on adverse conditions. Unique type test are conducted as per IS: 8909 & IS: 8337. The range of the terminals & connectors starts from 0.5mm 2 to 1000mm 2 with many variations suiting to many industries.
HAZARDOUS AREA GLANDSQuality is extremely important in an electrical system. It is maintained by undertaking stage wise inspection, which is always mandatory. Full fledge in house lab. Inspects raw material & out going finished products as per defined rejection / acceptance methods. Relevant Indian & International standards are maintained by concurrent inspections & close monitoring of quality standards. This will enable the customers to select the terminals as per the specification required.

 
TYPE OF TERMINALS APPLICATION
Tubular type terminals ends Widely used series for soldering or solder less crimping application made from Cu & Al. Standards followed are IS, BS & DIN
Ring tongue terminals ends Generally used along with control cables. Various shapes can be made & stud holes as per requirement can be made.
Reducer type terminals ends This series is recommended for usage in fuse gears, ICTP switches, watt meters etc.
Pin type terminals ends Termination in terminal blocks is being done with pin type terminal ends. Widely used in control panel wiring. Non-insulated, insulated & pre-insulated versions are available.
Fork Type terminal ends Fixing arrangement of LV / MV switch gears of different varies & hence to suit those application forks type terminal ends are designed.
In Line Connectors For enabling straight through joints of aluminum or copper cables in line connectors are widely used.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Elcon Cable Trays from Pune, Maharashtra.
Post Buy Requirement

Our Products

  1. Tube Fittings 3 Products available
  2. Adaptors, Plugs And Sockets

    1 Products available
  3. Kitchenware And Cookware

    1 Products available
  4. Electric Cable Making Machine

    1 Products available
  5. Electrical Cables & Wires

    1 Products available
  6. Storage Drums, Tanks & Containers

    1 Products available
  7. Cables And Wire Accessories

    1 Products available
  8. Others Products 1 Products available

Our Products

Our Complete range of products are RAPUSH BUTTON STATION, Earthing Material and support systems.

Gi Perforated Cable Tray

  • thicknesses 1.2 mm, 1.5 mm, 1.6 mm, 2.0 mm
ELCON is the leading in manufacturing perforated and ladder - type trays with accessories. Cable Trays are available in different sizes as per the customer specifications. We manufacture cable trays in the following thicknesses - 1.2 mm, 1.5 mm, 1.6 mm, 2.0 mm, 2.5 mm, and 3.0 mm. & width - 50 mm to 1000 mm, cable trays are available in different finishes like MS, Hot dip galvanized, powder coated, painted etc. The cable tray accessories for perforated ladder type cable trays are vertical bends, horizontal bends, inside bends, outside bends, reducers with radius 300, 600, 900 are avaialble.
View Complete Details

Junction Box

  • MECHANICAL DATA Material
  • Aluminium LM6 Weight
  • Refer the Dimension Chart IP Protection
  • IP 65 Finish
  • Anti corrosive Epoxy powder coated Cable Entry
  • Refer Chart. Canopy
  • Optional Cover Fixing
  • Threaded, Spigotted Hinge
  • Stainless Steel (Optional) Gasket
  • Neoprene Hardware

DESCRIPTION

Explosion proof junction boxes with threaded or spigotted covers. Available in six sizes, these boxes provide a wide range of terminations and distribution facilities. Integrally cast plates are provided for different combinations and cable entries on any of the four sides. Weatherproof protection is provided by high quality neoprene 'O' ring gaskets.

View Complete Details

RACEWAY DUCTS

  • STRENGTH Light Duty, Medium Duty & Heavy Duty
  • WIDTH (W) 50 mm to 600 mm
  • HEIGHT (H) 25 mm to 150 mm
  • THICKNESS (T) 1.2 mm, 1.6 mm, 2mm2.5 mm & 3 mm
  • FLANG HEIGHT (FH) 10 mm to 25 mm
  • INWARD BLEND (IB) 15 mm to 20 mm
  • LENGTH(L) 2500 mm / 3000 mm & 2444 mm (for Aluminum)
View Complete Details

RAPUSH BUTTON STATION

  • IP Protection IP 65
  • Finish Anti corrosive Epoxy powder coated
  • Cable Entry Depend on specs
  • Gasket Neoprene
  • Hardware Stainless Steel
  • Canopy Stainless Steel
DESCRIPTION
Where several control & indication functions in a hazardous area are required to be operated from one location, they can all be mounted in an Explosion proof Control Station. Control Stations are available with up to three separate enclosures for housing various control units and a separate integral terminal chamber. The clipon type terminals provided in the chamber are pre-wide to the control units through sealed cable bushes. A wide variety of control units can be selected for mounting into the enclosures. The control stations are also fitted with high quality neoprene gaskets to ensure weather proof protection.
View Complete Details

SS TUBE AND FITTING

ELCON TUBE FITTINGScome to you completely assembled, finger-tight. They are ready for immediate use. Dis-assembly before use can result in dirt or foreign material getting into the fitting and causing leaks

ELCON TUBE FITTING are installed in three easy steps.

Insert the tubing into the ELCON TUBE FITTING. Make sure that the tubing rests firmly on the shoulders ofthe fitting and that the nut is snug tight, in this position the tube does not rotate by hand.
Before tightening the ELCON nut, scribe the nut atthe 6.00 o'clock position.
Now while holding the fitting body steady with a backup wrench, tighten the nut one-and-one quarter turns* Watch the scribe mark, make one complete revolution and continue to the 9.00 o'clock position. *For 1/8", 3/16", 3 & 4 mm size tube fittings, only % turns from finger-tight is necessary the joint is now complete.
HIGH PRESSURE APPLICATIONS, HIGH SAFETY FACTOR SYSTEMSDue to the variation of tubing diameters, a common starting point is desirable. Therefore, use a wrench to snug up the nut until the tubing will not turn (by hand) in the fitting. Now tighten the nut one-and-onequarter turns and the fitting is ready to hold pressure well above the working pressure of the tubing.
RE-TIGHTENING INSTRUCTIONSDue to the variation of tubing diameters, a common starting point is desirable. Therefore, use a wrench to snug up the nut until the tubing will not turn (by hand) in the fitting. Now tighten the nut one-and-onequarter turns and the fitting is ready to hold pressure well above the working pressure of the tubing.
THREAD SPECIFICATIONSELCON connectors have one or more tubing end connections and the others with male or female pipe threads there are a variety of pipe threads for which ELCON Double Ferrule Fittings are available. The most popular thread connections are the American National Pipe thread (NPT) British standard pipe threads (BSP) and metric threads. These threads belong to standards of individual countries as well as iso where they have been codified All ELCON Fittings with pipe threads or stud end threads conforming to the specifications as detailed bellow
  • American National Pipe Thread (NPT) : reference specification ASA B2. 1: 1960ISO parallel pipe threao ( British standard pipe thread ) :Reference specifications BS 2779. ISO 228/1 DIN 259.JISB 0202.IS 2643
  • ISO taper pipe thread (British standard pipe taper thread )
  • Unified National pipe threads: Reference specifications ASA B1 1: 1964
View Complete Details

Copper Tube Fitting

We give below the specification to be followed for the various tunings for use with ELCON Double Ferrule Compression Fitting.Soft , annealed carbon steel hydraulic tubing to ASTM A 179, Din 2391 or equivalent based on ultimate tensile strength of 47000 psi and for metal temperatures not to exceed 20 deg C to 100 deg C. For higher temperature service, reducing factors for elevated temperature operation as specified in table 302.3 1A and 304.1.2 of the code for pressure piping in ANSI B 31.3 should be applied. The hardness of the tube is recommended to RB 7xThe hardness of the tube is recommended to RB 72 OR less. The Tubes should be suitable for bending and flaring and free of surface defects and imperfections

Annealed 304 or 316 Stainless Steel tubing to ASTM A 269 or A 213 or equivalent based on ultimate tensile strength of 75, 000 psi and suitable for temperatures 20deg C to 100 deg C.The hardness of these tubes is not to exceed RB 80 and is preferred in the range RB 70 74.Tubes to be suitable for bending and flaring and should be free o0f surface defact and imperfections.
Annealed 304 or 316 Stainless copper tubing to ASTM B 75 or ASTM B 88 based on an ultimate tensile strength of 30, 000 psi and for a temperature in the range of 20 deg C to 80 deg C Maximum hardness of the tube not to exceed RB 50. Tubes preferred in the range RB 40-45
Fully annealed Monel 400 seamless tubing conforming ASTM B165 or equvaient and based on dftimata tensile strength of 70.000 psi and for use with temperatures 20 deg C to 90 deg C.Hardness of the tube must be RB 75 maximum and is preferred in the range RB 68 72These tubes should be suitable for blending and flaring and free from all surface defects and imperfections
View Complete Details

Cable Tray System

  • STRENGTH Light Duty, Medium Duty & Heavy Duty
  • WIDTH (W) 50 mm to 1200 mm
  • HEIGHT (H) 25 mm to 100 mm
  • THICKNESS (T) 1.2 mm, 1.6 mm, 2mm2.5 mm & 3 mm
  • INWARD BEND (IB) 10 mm to 25 mm
  • LENGTH (L) 2500 mm / 3000 mm & 2444 mm (for Aluminum)

ELCON is the leading in manufacturing perforated and ladder type cable trays with accessories. Cable Trays are available in different sizes as per the customer specification. we manufactures cable trays in the following thicknesses - 1.2mm, 1.5mm, 1.6mm, 2mm, 2.5mm and 3mm, length- 2.5m, 3m and width - 50mm to 1000mmcable trays are available in different finishes like MS, Hot dip galvanized, pre-galvanized, powder coated, painted etc. The cable tray accessories for perforated ladder type cable trays are vertical bends, horizontal bends, inside bends, outside bends, reducers and tees with radians 300, 600, 900 are available.

ADVANTAGES OF ELCON CABLE TRAY

  • Cost Saving
  • Design Cost Savings
  • Dependability
  • Installation Cost & Time Saving
  • Material Savings
  • Maintenance Savings
  • Space Savings

STRENGTH Light Duty, Medium Duty & Heavy Duty
WIDTH (W) 50 mm to 1200 mm
SIDE CHANNEL HEIGHT (H) 50 mm to 150 mm
RUN WIDTH 30 mm to 50 mm
RUN HEIGHT 10 mm to 20 mm
RUN C TO C 25 mm to 100 mm
THICKNESS (T) 1.2 mm, 1.6 mm,2mm2.5 mm & 3 mm
BEND (TB) 10 mm to 25 mm
LENGTH (L) 2500 mm / 3000 mm & 2444 mm

 

FINISH SPECIFICATION RECOMMENDED USE
Painted As per Specification Indoor
Powder Coated As per Specification Indoor
Pre Galvanized As per Specification Indoor
Hot Dip Galvanized As per is 4759, 2629, 2633 Indoor / Outdoor

   

View Complete Details

CABLE TERMINAL AND LUGS

Entire ranges of copper tubular terminals are made from ETP grade & EC grade aluminum tubes. Terminals are exclusively designed for study performance even on adverse conditions. Unique type test are conducted as per IS: 8909 & IS: 8337. The range of the terminals & connectors starts from 0.5mm 2 to 1000mm 2 with many variations suiting to many industries.
HAZARDOUS AREA GLANDSQuality is extremely important in an electrical system. It is maintained by undertaking stage wise inspection, which is always mandatory. Full fledge in house lab. Inspects raw material & out going finished products as per defined rejection / acceptance methods. Relevant Indian & International standards are maintained by concurrent inspections & close monitoring of quality standards. This will enable the customers to select the terminals as per the specification required.

 
TYPE OF TERMINALS APPLICATION
Tubular type terminals ends Widely used series for soldering or solder less crimping application made from Cu & Al. Standards followed are IS, BS & DIN
Ring tongue terminals ends Generally used along with control cables. Various shapes can be made & stud holes as per requirement can be made.
Reducer type terminals ends This series is recommended for usage in fuse gears, ICTP switches, watt meters etc.
Pin type terminals ends Termination in terminal blocks is being done with pin type terminal ends. Widely used in control panel wiring. Non-insulated, insulated & pre-insulated versions are available.
Fork Type terminal ends Fixing arrangement of LV / MV switch gears of different varies & hence to suit those application forks type terminal ends are designed.
In Line Connectors For enabling straight through joints of aluminum or copper cables in line connectors are widely used.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us