Post Buy Requirement

Our Products

  1. Transmitter Device 8 Products available
  2. Industrial Blowers, Coolers & Fans 4 Products available
  3. Pressure Switches 3 Products available
  4. Sensors And Transducers 3 Products available
  5. Measurement Gauges & Fittings 3 Products available
  6. Measuring Instruments & Equipment

    2 Products available
  7. Air Vents

    2 Products available
  8. Analyzers And Analytical Instruments

    2 Products available
  9. Sensors

    2 Products available
  10. Fuses, Circuit Breakers & Components

    2 Products available
  11. Others Products 20 Products available

Other Products / Services

Our offered Product range includes Explosion proof DP Transmitter, Chemical resistant DP Transmitter, Fischer DE28 DP Transmitter, MODULATING Actuators and Heavy duty Tunnel Transit Dampers.

Industrial Flame Detector

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
The RFD2X (Explosion proof) detector discriminates between flames and other light sources by responding only to set optical wavelenghts and flame flicker frequencies. The built-in filters and signal processing techniques help reduce false alarms due to flickering sunlight. Key Features:1.Wide view angle horizontal and vertical2.Built-in Ultra violet and Infrared flame Sensors3.Explosion Proof (ATEX Ex d IIB + H2)4.Range of view up to 100ft. (30m)5.Reduces false alarm by built-in combination filters and signal processing techniques6.IP67 Rated for water and dust tight protection7. 4-20mA Output8. 3 built-in relays (Alarm, Fault & Warning Alarm)9. ATEX, FM approved10.High accuracy and repeatability Technical Specifications:1.Measuring Parameters: flame (general) detection, fire incidence detection2.Technology: UV IR spectrum3.Detection range: 0- 30 meter ( 0 100 ft)4.Field of View : Horizontal: 90 , Vertical: 90 5.Ambient temperature: -40 +75 C6.Storage temperature: -50 +80 C7.Power Supply: 24V DC8.Interface: analog or relay output9.Sensor Housing: SUS 31610.Ingress protection: IP6711.Approval: FM (US) 3260, ATEX Application:-The RFD2X (explosion proof) Ultra Violet Infrared flame detector is suited for installation where open flame fires may be expected. It responds to the light frequencies emitted from flames during combustion. This detector is used to detect flames from burning aviation fuels, butane, grain & feeds, hydrogen, paper, natural gas, and petrol.1.Oil & Gas, Petrochemical, refinery2.Chemicals3.Cold stores4.Pharmaceuticals, medicinal formulation
View Complete Details

Flame Detector

Flame detectorRFD2Xis ATEX, FM approved instrument for general fire detection in hazardous as well as safe areas.

RFD2X is based on UV / IR technology, detecting fire over long distance, with no cross-sensitivity and false alarms. It has wide view angle upto 30 meter detection range. IP67 protected with SUS 316 housing, it can be installed at any location chemical industry, oil & gas refinery, power plants etc

View Complete Details

Roof Exhaust Fans

Greenheck model G and GB offers the industrys best performance and durability for general clean air applications where air is discharged downward, toward the roof surface

View Complete Details

Explosion Proof DP Transmitter

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
Working Principle:-Fischer DE38 DP Transmitter uses a tough yet flexible sensing diaphragm embedded between stiffening plates and balanced by springs on either side.Linear displacement of this LVDT is proportional to the pressure difference across the diaphragm. Thus, this displacement is converted to electrical signal output. An optional output signal can be slew rate limited, spreaded, inverted and transformed non-linearly by means of a table function.Key Features: 1.Explosion proof ATEX certification with CE Ex II 3 G c EEx nA IIC T4 for DE38###R and CE Ex II 3 D c IP65 T125 for DE38###S2.Robust design with high repeatability3.Over pressure protection4.Wear free non-contact LVDT sensing element, thus no maintenance5.Signal output with possibility of various characteristic curve6.Characteristic conversion of output via 3.30 entries table7.Complete set-up of all parameters and print out by using optional PC programming interface EU038.Measuring range: 0-400 mbar to 0-1600 bar9.Operating temperature: Ambient: -10C to +70C; Media:-10C to +70C10.Protection class: IP65 per DIN EN 6052911.Output: 04-20mA, 0-10 VDC12.Display: 3 digit LCDApplications areas:1.Monitoring of compressors, filters and vacuum systems2.Measurement of differential pressure between supply and return fuel lines in heating & cooling systems (Chillers)3.Flow measurement lubricants, oil, hydrocarbons, water, gases4.Control pressure air, gases, oil, water, lubricants5.Level measurement- tank, container of lubricants, oils, water, liquids etcIndustrial areas: 1.Cement plants2.Nuclear plants, coal or gas fired power plants3.hydro power plants4.Manufacturing and chemical plants
View Complete Details

Air Measuring Control Dampers

Greenheck airflow measuring products are available with either differential pressure based technology or thermal dispersion technology. AMS is accurate air flow measuring station with pressure transmitter proportional to air flow, while AMD is control air damper combined with airflow measuring station for monitoring and control of air flow. AMD-TD is control air damper with airflow measuring station based on thermal dispersion technology.

View Complete Details

Underground Ventilation Control

  • Min. Order (MOQ) 1 Piece(s)
  • Fischer Tunnel Dumpers
Key features:1. Airfoil blades with various material options2.robust, performance oriented3.nfpa, ul555 compliant4.various actuators options available key features:1.maximum pressure: 12 24 in wc2.velocity: 20.3 ms3.leakage: 8 cfmsq. Ft. @ 4 in. Wc4.blade deflection: l180 (standard)5.blade profile: fabricated airfoil extruded airfoil fire rated airfoil6.blade material: galvanized steel aluminum ss 304 ss 3167.certifications: nfpa 130, 502; ul 555s; bs476 typical ventilation applications area include:1.subway ventilation system2.tunnel ventilation control system3.underground ventilation system
View Complete Details

Air Measuring Control Damper

Greenhecks IAQ-42 air flow measuring control damper utilizes patented Speciflow Technology built into the controller to measure the pressure, position of the damper blades, and temperature of the air flowing through the damper. The IAQ-42 will control air to prevent over ventilation, under ventilation and provide energy savings during low occupancy periods. The IAQ-42 can help buildings meet the indoor/outdoor air requirements of ASHRAE Standard 62 and California Title 24 by providing accurate monitoring and control of outside air.

View Complete Details

Industrial Flue Gas Analyzer ,Industrial Emission Analyzer

E8500 is portable, hand held, light weighted flue & emission analyser for analysis of gas composition, temperature, pressure, velocity etc parameters of any type of combustion and emission, thus support in combustion & process efficiency and pollution control in industrial and commercial applications eg boiler, furnace, stack, plume, Engine etc installations.

Features

  • Configurable up to 9 Gas Sensors: O2, CO, NO, NO2, SO2, H2S (Electrochemical), CO2, CxHy, High CO (NDIR)
  • Low NOx and True NOx Measurements
  • Builtin Thermoelectric Chiller with Automatic Condensate Removal
  • Wireless Remote Printer
  • Draft & Differential Pressure Measurement
  • Multi-Channel Thermometer
  • Software for RealTime Data Logging, Graphing, and Reporting
  • Bluetooth Wireless Communications
  • CO Dilution AutoRange for Measurements up to 20, 000ppm
  • Automatic LongTerm Monitoring & Data Logging with Internal Memory
  • High Temperature Probes with Sintered Filter
  • Gas Velocity Measurements with Pitot Tube
  • CO2%, Efficiency, & Excess Air Calculations
  • Rotating & Zoom LCD Display
  • High Speed Microprocessor for faster value processing
  • Light Weight, Durable, & Easy to Transport Design
  • Complies with US EPA CTM-030 & CTM-034 test methods
  • Rechargeable Battery
  • PC Software Package

ApplicationsE8500 is a powerful, multi-feature, portable analyser designed for flue gas, plume emissions monitoring, maintenance and datalogging of combustion parameters of flue gas, stack gas, boilers, burners, gas & diesel engines, turbines, furnaces, kilns, heaters, and laboratory analysis.

  • Monitoring of flue gas and stack gas composition
  • Measure and monitor combustion efficiency in any industry chemical, fertilizer, pharma, steel etc
  • Pollution monitoring and control by monitoring exhaust composition
View Complete Details

Portable Emission Analyzer

E8500-MK offer hand-held flue and combustion analysis solution for marine application . Being handy and light weighted, it is easy to carry on-the-go, with multiple options to suit site requirement. With its multi parameter analysis feature, it can help ships achieve and confirm compliance with MARPOL Annex-VI and the NOx Technical Code and obtain IAPP certification.

Features

  • Eight (8) Gas Sensors Total: O2, CO, NO, NO2, SO2 (Electrochemical), CO2, CxHy, High CO (NDIR)
  • True NOx Measurements and Low NOx Capable
  • Consumable Spare Parts:(10) Line Filters and (5) Condensation Filters
  • Builtin Thermoelectric Chiller with Automatic Condensate Removal
  • 40 / 1m Sampling Probe (2190F/1200C max)
  • with 10 / 3m hose & Sintered Filter for probe tip
  • Draft & Differential Pressure Measurement
  • Multi-Channel Thermometer
  • Software for RealTime Data Logging, Graphing and Reporting
  • Blue Tooth Wireless Communications
  • Automatic LongTerm Monitoring & Data Logging with Internal Memory
  • Efficiency & Excess Air Calculations
  • Rotating LCD Display
  • Protective Carrying Case
  • Light Weight, Durable, & Easy to Transport Design
  • CO Dilution AutoRange for Measurements up to 20, 000ppm
  • High Temperature Probes with Sintered Filter
  • Gas Velocity Measurements with Pitot Tube
  • High Speed Microprocessor for faster value processing
  • Light Weight, Durable, & Easy to Transport Design
  • Rechargeable Battery
  • PC Software Package

ApplicationsE8500-MK is suitable for marine application to Engine, flue gas, plume emissions, maintenance and datalogging of combustion parameters.

  • Monitoring of flue gas and stack gas composition
  • Measure and monitor Engine & combustion efficiency
  • Pollution monitoring and control by monitoring exhaust composition
View Complete Details

Fischer DE38D410 - Flender Flow Meter

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
  • Model Number DE38D410
Working Principle: -Fischer DE38 DP Transmitter uses a tough yet flexible sensing diaphragm embedded between stiffening plates and balanced by springs on either side.Linear displacement of this LVDT is proportional to the pressure difference across the diaphragm. Thus, this displacement is converted to electrical signal output.An optional output signal can be slew rate limited, spreaded, inverted and transformed non-linearly by means of a table function. Key Features:1.Measurement range 0 1 bar2.Static operating pressure 25 bar3.Diaphragm and sealing of Viton4.Operating voltage 24 V DCAC5.Output signal 4-20 mA square rooted6. 3 -digit LED display7. ECCN: N AL: N8.Robust design with high repeatability9.Over pressure protection10.Wear free non-contact LVDT sensing element, thus no maintenance11.Signal output with possibility of various characteristic curve12.Characteristic conversion of output via 3.30 entries table13.Complete set-up of all parameters and print out by using optional PC programming interface EU03 Applications areas:1.Volume flow monitoring of lubricants oil, mill oil2.Gearbox lubricant flow monitoring3.Flow measurement lubricants, oil, hydrocarbons, water, gases Industrial areas:1.Cement plants2.Nuclear plants, coal or gas fired power plants3.hydro power plants4.Manufacturing and chemical plants
View Complete Details

Chemical Resistant DP Transmitter

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
  • Model Number DE05
Differential pressure DE05 is based on modular design. Measuring cell and pressure caps form differential pressure measuring mechanism. The electronics including power supply, amplifier and control PCB are located in IP65 protected housing.Key Features:1.Rugged, wear & tear resistant sensor design2.High corrosion resistant3.Rinsable pressure chambers4.Suitable for aggressive media5.Unaffected by vibration, radiation, dirt etcKey Specifications: 1.Measuring range: 0 100 mbar to 0 25 bar2.Measuring principle: fluid filled membrance diaphragm system with inductive pickup system3.Maximum static pressure: 100 bar4.Measuring span: can be set steplessly from 20% 100% of the full scale5.Measuring start: can be set steplessly from 0% 100% of the measuring range when the characteristic curve falls (switchable) can be set steplessly from 100% 0% of the full scale6.Temperature or measuring media: -10 C to +70 C7.Ambient temperature: -10 C to +70 C8.Electromagnetic compatibility: DIN EN 61000-6-2 (interference resistance), DIN EN 61000-6-4 (emitted interference)9.Output: analog 04-20mA, with characteristic curve of linear, rising or falling (switchable)10.Measuring membrane: Nickle-Beryllium DurathermFluid Filling: Baysilone oil PD 511.Measuring chamber, separating membrane: Chromium nickel steel 1.4571 (AISI 316Ti)12.Protection: IP as per EN 60529 IEC 52913.Product qualification: in compliance with KTA 3505
View Complete Details

Fischer DE28 DP Transmitter

  • Min. Order (MOQ) 1 Piece(s)
  • Fischer DE28
Working Principle: -DE28 works on principle of movement of pressure diaphragm due to pressure or differential pressure applied on either side.Fischer DE28 has NBR or Viton diaphragm, thus offering continuous, repetitive high performance. The applied pressure create unbalanced force on the springs, which keep moving until new equilibrium reached.The centre mounted tappet transfers the motion of diaphragm system to core of inductive displacement transducer. Therefore, subsequent converter circuit converts this displacement into electrical output signals. Key Features:1.Robust design with high repeatability of switching contacts2.Over pressure protection3.Short circuit protection4.Maintenance free due to inductive circuit movement Key Specifications:1.Measurement range: 0-400 mbar to 0-6 bar2.Operating temperature: Ambient: 0C to +70C3.Protection class: IP54 per DIN EN 605294.Static operating pressure: 16 bar5.Diaphragm: NBR or Viton6.Measuring linearity: < 2.0% Full scale7.Measuring hysteresis: < 1% Full scale8.Operating voltage: 24 V DCAC9.Output signal: (0) 4-20 mA or 0-10 V, linear, proportional10.Zero adjustment with the dial11. 1 or 2 adjustable microswitches12.Pressure chamber: Brass13. Pressure connection: G 18, female thread Applications areas:1.Water pumps, lube pump monitoring2.Pump control3.Pipe water liquid flow monitoring4.Air ducts monitoring Industrial areas:1.HVAC & MEP applications2.Cement plants3.Hydro power plants4.Manufacturing and chemical plants

Additional Information:

Payment Terms : L/C, D/P, T/T

View Complete Details

MODULATING Actuators

  • Storage Temperature -30 to 60 C
  • Supply Voltage AC230v
  • Frequency 50-60 Hz
  • Running Power Consumption 5.5 W
  • Torque 16 Nm
  • Damper Area 3.0 m2
  • Running Time 80-110 s
  • Degree of Protection IP 54
  • Port New Delhi
  • Control Signal DC0-10V
  • Protection Class II
View Complete Details

Dp Transmitter

Fischer DE03 combines electronic measurement with a rugged sensor design, resulting in high accuracy, highdifferential and static rating, and ability to handle difficult media.

It is available with local digital readout and electronic limit detection relays, with measuring range of 0 40 mbar to 0 25 bar, with analog linear / square root output.

Differential pressures are applied on outer flexible stainless steel isolating diaphragms, at opposite ends of the sensing capsule. A third diaphragm in between acts as the sensing element.

The cavity of the capsule is filled with hydraulic fluid, and is divided into two separate parts by the central sensing diaphragm. Pressures acting on the outer diaphragms are transferred to the sensing diaphragm by the fluid, through apertures in the intermediate plates. An axial metal rod joined to the sensing diaphragm forms the core of a precision LVDT displacement sensing element.

When pressures are equal on both sides of the sensing diaphragm, it is at zero position. Pressure difference across the sensing diaphragm causes it to deflect away from the higher pressure side, resulting in linear displacement of the LVDT core. This displacement is sensed by the LVDTs coils, and converted by an electronic module to an output signal proportional to the pressure differential.

Inward deflection of each isolating diaphragm is limited by the intermediate plate behind it. This also limits the pressure that can be transferred to the sensing diaphragm, and through it, to the isolating diaphragm on the other side. Thus, all three diaphragms are fully protected against excess differential pressure in either direction, and also against high static pressures.

Key Features:
  • Rugged, wear & tear resistant sensor design
  • High corrosion resistant
  • Low hysteresis
  • Unaffected by vibration, radiation, dirt etc
Key Specifications:
  • Measuring range: 0 40 mbar to 0 25 bar
  • Nominal pressure rating: 100 bar
  • Maximum static pressure: 100 bar
  • Maximum differential overpressure: upto max. static pressure; pressure differential in either direction
  • Operating temperature: Ambient: -10 C to +70 C;
  • Permanent media temperature: -15 C to +70 C
  • Protection class: IP54 per DIN EN 40050
  • Output signal: (0) 4 20mA, 0 10 V, square root conversion accuracy
  • Display: 3 1/2 digit LCD
  • Accuracy: +/- 1.6% full scale
  • Diaphragm (isolating / sensing): Stainless steel 1.4571. Optional: Hastelloy-C
  • Seals: Viton (fluorocarbon elastomer). Optional: PTFE coated
Application areas:
  • Water and effluent treatment plants, and other filtration applications
  • Filter condition monitoring
  • Flow monitoring in sprinkler systems
  • Flow measurement of steam and hot water, using differential pressure flow sensors, in remote heating systems
  • Monitoring pressure drop across valves
  • Pump Control dependent on differential pressure in block unit heating power stations
Application areas:
  • Manufacturing and chemical plants
  • Marine, shipping application
  • Onshore and offshore area
  • Petrochemical, solvent industry
  • Sewage, effluent treatment plants
View Complete Details

Ammonia Gas LEL Detector

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name ekeindia
  • Place of Origin India
Key features:1.catalytic bead based pellistor sensor cell with low flash energy2. 10-bit microprocessor control unit3.non-intrusive one man calibration via hall effect switches4.atex certified explosion proof flameproof, suitable for zone 1, 2 gas explosion installation5.linear, proportional analog industry standard current output6.continuous system self-diagnosis with watch dog7.flashback arrestor with sintered filter8.auto zero point tracking to zero point compensation9.sil 2 hw tuv certified10.rs485 serial interface with modbus rtu communication (optional)11. 1 or 3 relay output module (optional)12.system and alarm led indicators (optional)13. Modbus rtu communication over rs485 serial interface
View Complete Details

Fischer NC57 - Capacitive Liquid Level Transmitter - Diesel, Water, Sewage

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name ekeindia
  • Model Number NC57
  • Place of Origin India
  • Fischer NC57
Key Features:1.Rugged design2.IP67 ingress protection3.Built in electronic module4.Easy setup and installation Key Specifications:1.Sensing technology: Capacitance sensor cell2.Level measuring range: 400 2000 mm (other range on special order)3.Operating pressure: 10 bar max.4.Operating ambient and media temperature: max. 80 C5.Number of electrodes: 16.Process connection: threaded G 12, G 17.Ingress protection: IP678.Supply Voltage: 9 32 VDC9.Output Signal: (0) 4 -20mA (0) 1 (5) 10V10.Electrical connection: male M12 type round shell connector11.Housing: stainless steel12.Media contact: blank rod of stainless steel 1.4404, ECTFE coated Application areas:1.Water, DM Water2.Effluent, industrial discharge3.Diesel, lubricants, hydrocarbons
View Complete Details

Fischer DS21 ATEX Industrial DP Switch

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
  • Model Number DS21 ATEX
  • Place of Origin india
  • Fischer MS21
Working principle: the pressure is applied directly to a ceramic diaphragm, causing a deformation. This mechanical deformation is converted to an electric signal by means of dms-bridge located at the rear side.An electronic system is integrated in the set-up of the appliance, converting the dms signals to electric standard signals 420ma 010 vdc. Key features:1.high accuracy2.robust and compact design3.overload protection4.high vibration resistant5.minimum hysteresis key specifications:1.measuring range:-1.0 0.0 bar to -1.0 -24.0 bar (max. Pressure: 3 80 bar)0.0 1.6 bar to 0 60.0 bar (max. Pressure: 5 200 bar)2.linearity: < 1% full scale3.hysteresis: < 0.5% full scale4.permissible ambient temperature: 0 c +60 c5.permissible medium temperature: 0 c +85 c6.protection class: ip65 acc. To din en 605297.materials (media contact): chrome nickel steel 1.4305, ceramics, al2o3, gaskets8.material (housing): chrome nickel steel 1.43059.nominal power supply: 24 vdc ac10. Output: linear, 42-ma 010 v, 23-wire industrial areas:1.nuclear power plants2.thermal gas fired power plants3.chemical & manufacturing industries4.semiconductor plants

Additional Information:

Payment Terms : L/C, D/P, T/T

View Complete Details

Fischer NS01 Level Switch

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name ekeindia
  • Model Number NS01
  • Place of Origin India
  • Fischer NS01
Key Features:1.Socket welding system with modular process adaption2.Measuring point free of dead space3.Adjustable for various media4.Material contact to media from PEEK5.FDA compliant Key Specifications:1.Maximum operating pressure: 10 bar2.Permissible media temperature: 0 C to +100 C (permanent)3.Permissible ambient temperature: -10 C to +70 C4.Ingress protection: IP69K5.Response time < 0.2 sec6.Cleaning sterilisation: +150 C (max. 30 mins)7.Operating voltage: 18 32 V DC8.Output signal: max. 50 mA (active)9.Output: reversible (inverting)10.Pressure connection: G 12 thread11.Connection housing: stainless steel 1.430512.Tip of the sensor: PEEK13.Gasket: free from elastomer Application areas:1.Monitoring of minimum or maximum filling levels of vessels2.Protection of pumps against dry running3.Detection of liquid level in vessels and pipes
View Complete Details

Temperature Switch

emperature monitor with limit switch contacts, high switching capacity, stainless steel media contact material, UL, VDE approvedMake: Fischer Messtechnik (Germany)Model: TS61

Fischer TS61 temperature switches are used for monitoring and controlling out-of-limit temperature conditions in heating and cooling systems, pipes, process vessels, process engineering and storage vessels. TS61 is ideally suitable for monitoring, control and protection of compressors, motors, pumps, hydraulic power systems, plastic processing machines, chillers etc.

Operation Principle:

Fischer TS61 is housed in stainless steel casing and is highly vibration proof. When the process temperature exceeds the set-point value, the switch contacts open to break the electrical load circuit. The switch contact close automatically when the temperature drops below set-point value.

Key Features:
  • Failsafe, high current switching capacity (resistive and inductive loads)
  • Fast response time
  • Easy installation
  • Instantaneous snap action switching
  • Self-resetting
  • Set point range: 70C 180C in 5K steps
  • Switch point accuracy: 5K
  • Vibration resistant per Germanischer Lloyd (GL) specifications, characteristics curve 2
Key Specifications:
  • Temperature set-point range: 70C +180C in 5K steps
  • Set-point tolerance: 5K
  • Material, media contact: Stainless steel 1.4571
  • Process connection: threaded stem G 1/2 (M)
  • Switching action: normally closed contacts, open above set-point, self-reset
  • Re-set temperature: 40 15K below set-point temperature (other values on special order)
  • Max. media temperature: 80C
  • Contact rating: 250V AC, 2.5A (resistive load), 1.6 A(inductive load)
  • Switch life expectancy: 10, 000 operations at maximum load
  • Switch action: instantaneous, snap action switching. response time varies slightly with load current and operating temperature
  • Maximum load current: 6.3 A
  • Electrical connection: DIN EN 175301-803 plug-connector
  • Protection class: IP54 per DIN EN 60529
  • Temperature sensing element: UL And VDE approved bimetal thermostat element
Application / Industry:
  • Food processing
  • HVAC & R
  • Chemical process industries
  • Petrochemicals
  • Marine, shipping, ship building
  • Water, effluent treatment system
View Complete Details

Fischer DE58 DP Transmitter Switch

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
  • Model Number DE58
Working Principle: DE58 is based on a robust and durable diaphragm measuring unit that is suitable for measuring over pressure, under pressure and differential pressure. The pressure to be compared have an effect on spring mounted measuring diaphragm. Key Features:1.Robust Design, over pressure protected2.Maintenance free through wear-free inductive pickup mechanism3.Switchable pressure units4.Optional signal output with possibility of characteristic curve spread and reversal with any offset5.Characteristic curve implementation via table with max. 30 measuring points6.Complete adjustment of all parameters and measuring point protocol possible through optional PC adaptor EU037.Large LED Display Key Specifications:1.Measuring range: 0 160 mbar to 0 600 mbar2.Maximum static operating pressure: 40 bar3.Overload capacity: single sided overpressure proof upto the rating of measuring system, (+) and (-) side, vacuum proof4.Straight line error (max): 2.5% full scale5.Temperature drift: 0.8% full scale 10k6.Pressure connection: female thread G 14 without optional cutting ring fitting for 6 or 8 mm tube7.Operating ambient & media temperature: -20 C to +70 C8.Protection class: IP65 per DIN EN 605299.Electrical output: (0) 4-20mA, 0-10V, 3 wire10.Power supply: 24 V DC AC11.Switching contacts: 2 sets of programmable voltage free contacts: NO or NC12.Display: 3 12 digit LED display13.Electrical connections: two round shell multi-pin connector sockets (M12, male)14.Material, housing: polyamide PA 6.615.Measuring element: brass, VITON, EPDM
View Complete Details

Heavy Duty Tunnel Transit Dampers

Greenheck offers heavy duty tunnel transit dampers, Model: HTD, with automated operation by pneumatic or electrical actuators (modulating or on / off). Based on unique airfoil blades, rugged bearing and mechnical parts, these dampers offer uninterrupted, reliable and fail-proof performance in one of most difficult working environment like tunnels, subways, coal mines, conveyors area etc.

Underground road and metro tunnels are some of the most difficult environments in the world. High humidity, dust-laden air, and limited access can make the installation and operation of ventilation systems problematic. Greenhecks tunnel dampers, HTD series, is designed to meet these challenges.

HTD dampers uses airfoil blade design with various material like galvanized steel, 304, 316 etc to meet application requirements. These are tested and compliant to NFPA 130 and 502. These are designed to keep maintenanceprocedures simple and low in frequency.HTD dampers comes with various options for actuator for automated operations. Pneumatic actuators, electrical, spring return, modulating or power on / off are some of the available actuators type.

Key Features:
  • Airfoil blades with various material options
  • Robust, performance oriented
  • NFPA, UL555 compliant
  • Various actuators options available
View Complete Details

Oxytrans M - Dissolved Oxygen Monitor

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name ekeindia
  • Model Number Oxytrans M
  • Place of Origin India
Key features:1.optical technology; no need for electrolyte and membrane changes2.short response time and excellent long-term stability3.applicable for a wide range of concentrations and temperatures4.highly accurate and virtually maintenance-free5.sturdy aluminum housing (ip 65) key specifications:1.liquid phase measuring range: i) 1 ppb 2 ppm or ii) 30 ppb 35 ppm2.liquid phase accuracy : i) 1 ppb or ii) 30 ppb3.gas phase measuring range: i) 0 4.2 % o2 or ii) 0 50 % o24.gas phase accuracy: i) 0.002 % o2 or ii) 0.03 % o25.response time: t90 10 s6.material: 1.4404aisi 316l, silicone (fda), ptfe (fda)7.datalogging: manual and automatic with a logging time of 5 to 600 seconds; approx. 5, 000 measurement values; pc software and usb-interface8.power supply: battery operated
View Complete Details

Industrial Combustion Gas Analyzer

E4400 offer perfect solution for combustion and emission parameter analysis and efficiency measurement for any industrial and commercial application in boiler, furnace, stack, plume, Engine etc installations. Being handy and light weighted, it is easy to carry on-the-go, with multiple options to suit site requirement.

Features

  • Configurable and compatible upto 4 gas sensors
  • True NOx Capable
  • Carbon monoxide sensor with NOx filter
  • Built-in local non-thermal printer, for onsite & lasting reports
  • Draft & Differential pressure meter
  • 2 channel thermometer
  • Rechargeable Lion Battery for longer working hours
  • Bigger LCD display with Zoom in/out function for better visualisation
  • External water condensation trap
  • PC software with USB communication cable
  • Unbreakable metal probe & hose connections
  • Optional: Dilution pump for CO auto-range measurement upto 50, 000ppm
  • Easy Field replaceable pre -calibrated sensor cell

ApplicationsE4400 is a valuable tool designed for emissions monitoring and maintenance & tuning of combustion processes including boilers, burners, gas & diesel engines, turbines, furnaces, kilns, heaters, and laboratory analysis.

  • Monitoring of exhaust gas composition
  • Measure and monitor combustion efficiency of boilers, kiln, furnace, engines etc
  • Pollution monitoring and control by monitoring exhaust composition
View Complete Details

Probe Cable

  • Operating Voltage 24 VDC
  • Protection class IP68
  • Output Signal 0 - 20 mA
  • Port New Delhi
  • Measuring Range 0 - 1 to 0 - 250 m Cable Length
View Complete Details

Pressure Sensor

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
  • Place of Origin India
  • Fscher Wind Sensor
-hd52 comes with standard configuration with wind direction, wind speed and compass and offer two analogical output, both for wind speed and for direction, factory configurable among 4-20ma (standard) or voltage (optional). Optionally available, (accredia) ilac-mra traceable factory calibration. Key features:1.ultrasonic detection technology2.multi-parameter monitoring3.no effects of humidity, moisture, temperature, radiation, vibrations etc5.bms, plc integration key specifications:1.measuring parameters: wind direction, speed and compass (standard), optional: relative humidity, temperature, barometric pressure, solar radiation2.measuring range:-wind direction: ultrasonic sensor, 0 360, 0.1 resolution-wind speed: ultrasonic sensor, 0 60 ms, 0.01 ms resolution-compass: magnetic, 0 360, 0.1 resolution-air temperature: pt100, -40c to +60c, 0.1 c resolution-relative humidity: capacitive sensor, 0100 % rh, 0.1% rh resolution-barometric pressure: piezoresistive sensor, 6001100 hpa, 0.1 hpa resolution-solar radiation: thermopile, 02000 wm2, 1 wm2 resolution8.output: 2 x linear, proportional analog (4-20ma) standard9.communication protocol: nmea, modbus rtu serial interface rs485, rs23210. Ip66 ingress protection applications areas:1.environment monitoring2.weather stations tunnel, industries, chemical plants, petrochemicals3.agriculture4.marine and harbour application5.airports, defense facilities6.hvac, construction

Additional Information:

Payment Terms : L/C, D/P, T/T

View Complete Details

Jola Liquid Electrode

  • Length approx. 22mm
  • Port New Delhi
  • Insulators PP and cast resin
  • Electrode Rods stainless steel 316Ti
View Complete Details

Portable Detector

PGD-H2S is portable, handheld battery operated gas detector for toxic limit detection and alarm for h2s gas in ambient air etc. It is equipped with large LCD display, internal alarm, flashing LED, datalogger facility, suction pump etc and safe for working in hazardous areas

PGD-H2S is portable, handheld gas detector powered by 6V battery for toxic limit detection of hydrogen sulphide in air, confined space, pipeline, sewage lines, manholes etc.

It works on electro-chemical sensor technology, with either diffusion based sampling or active suction pump sampling. It is equipped with large LCD Display for alarm, measuring value readout, battery status etc.

It has inbuilt alarm with LED flasher, vibration with optional data-logging facility, and RS232 output for data transfer.

Key Features:
  • Accurate detection
  • Battery operated, portable
  • Light weight
  • Large LCD display
  • Inbuilt vibration, alarm with flasher
  • Data-logging facility
  • Optional: sample suction facility
  • configurable alarm limit
  • High resolution and accuracy
View Complete Details

Carbon Dioxide Sensor

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Fischer
GST-CO2 is high accuracy, industrial grade transmitter with gold-plated, dual beam non-dispersive infra-red (NDIR) CO2 sensor cell. It is designed for continuous monitoring of CO2 concentration in ambient air, gas in closed rooms, ducts or open air. GST-CO2 offers industry standard analog (voltage or current) output, suitable for integration with any process signal controller PLC system or SCADA. GST-CO2 is housed in polycarbonate UL-V0 certified flame retardant enclosure with IP65 ingress protection. This enable only gas sample to pass through to sensor cell, but no dust and moisture, hence offering long sensor life and high accuracy.Key Features: Continuous, online monitoringNo cross-sensitivity due to background gasesNo effects of humidity, moisture, temperature, radiation, vibrations etcBMS, PLC integrateableSuitable for any applicationLong expected life Key Specifications: Measuring range: 020, 000 ppm or 02% Vol volSensor technology: non-dispersive infra-red sensor cell, Gold plated, dual beamOutput: linear, proportional analog (4-20mA, 0-10V) standardOptional: RS485 Modbus RTU serial interfaceOperating temperature: 0C to +50CLow voltage operation 24V DCIP65 ingress protection with hydrophobic and oleophobic filterWall, ceiling and duct mountablePolycarbonate housing with UL-V0 certified Applications areas: Cold storage potatoes, apple, mango, kiwi, banana, etcControlled atmosphere chamber kiwi, applesFurnace, heated conveyor beltsIncinerators, manufacturing unitsMushroom spawning chambers
View Complete Details

Pitot Tube

  • Length 300 mm
  • Port New Delhi
  • Diameter 3 mm
  • Reference TPL-03-300
View Complete Details

Airflow Measuring Station

The AMS is an accurate airflow measuring station and is furnished with a properly sized pressure transducer that outputs a signal proportional to cfm. The AMS is compatible with a field supplied controller or a factory supplied LON controller that uses a signal to position a damper (sold separately) to the airflow required.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us