Our Products
Leading Manufacturer, Supplier & Retailer of Aggregate Crushing Value Apparatus, Benkelman Beam Apparatus, Proctor Compaction Apparatus, Core Cutter Apparatus and Carbon Residue Apparatus.
The aggregate crushing value provides a relative measure of the resistance of an aggregate to crushing under a gradually applied compressive load. The oven dried and accurately weighed aggregates are subjected to crushing test on compression testing machine and weight of the resultant fines passing the specified IS sieve to the total weight of the sample expressed a s a percentage is defined as Aggregate Crushing Value. The apparatus is available in three size 75mm dia for 1/8” to ¼” size aggregate, 150mm dia for 3/8” to ¾” aggregate (standard) and 300mm dia for 1” to 2” aggregate.
General Description & Specification :Consists of Case hardened Mild steel cylindrical container of 150mm dia + 0.5mm x 130mm to 140mm high with base plate 200 to 230mm square x 6mm thick. A plunger of 148mm + 0.5mm dia x 100 to 115mm high. All parts directly coming in to contact with the specimen during the test are made of mild steel duly case hardened. Supplied complete with tamping rod, 16mm dia x 600mm long, one end rounded.
Optional Accessories :The following accessories are not part of the standard supply and are supplied at an extra cost.
The device was developed by U.S. Bureau of Public Roads and is used to determine of the rebound deflection of flexible pavement under static load.
General Descripation & SpecificationBenkelman Beam : Beam Ratio : 2 : 1
The complete instrument is light weight and is supplied in two parts for easy assembling and disassembling on site with help of hand tools and also it becomes easy to carry with the help of handle.
In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the a stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge.
In use one end of the beam rests at a point under investigation while the beam is pivoted at the centre. The free end carries a dial gauge to record the deflections and the other end is kept on the a stable platform. Because of beam ratio small deflection is magnified and recorded on the dial gauge
It will be made of Mild steel having capacity of 1000 cc with an internal diameter of 100 + 0.1 mm and an internal effective height of 127.3 cm + 0.1 mm. The mould will be fitted with a detachable base plate and removable extension collar approximately 60 mm high. The internal surface of the mould will be smooth. It will conform to the requirements given in the IS 2720 (Part VII). Complete with our own test certificate.
Light Rammer2.6 Kg x 310 mm fall. A metal chrome plated rammer having 50 mm dia. Circular and weighing 2.6 kg. The rammer will be equipped with a suitable arrangement for controlling the drop to the specified height of 310 mm. It will conform to the requirement given in the IS 2720 (Part VII), IS 9198.With our own test certificate.
2250 ccIt will be made of Mild steel having capacity of 2250 c.c with an internal diameter of 150 + 0.1 mm and an internal effective height of 127.3 cm + 0.1 mm. The mould will be fitted with a detachable base plate and removable extension collar approximately 60 mm high. The internal surface of the mould will be smooth. It will conform to the requirements given in the IS 2720 (Part VII). Complete with our own test certificate.
Heavy Rammer4.89 Kg x 450 mm fall. A metal chrome plated rammer having 50 mm dia. Circular and weighing 4.89kg. The rammer will be equipped with a suitable arrangement for controlling the drop to the specified height of 450 mm. It will conform to the requirement given in the IS 2720 (Part VII), IS 9198.With our own test certificate.
A concrete structure is considered to be of adequate durability if it performs in accordance with its intended level of functionality and serviceability over an expected or predicted life cycle. Concrete durability depends largely on the ease (or difficulty) with which fluids (water, carbon dioxide, oxygen) in the form of liquid or gas can migrate through the hardened concrete mass. Concrete is a porous material. Therefore, moisture movement can occur by flow, diffusion, or sorption. We are concerned with all three, but generally the overall potential for moisture in concrete by these three modes is referred to as its permeability.
General Description & SpecificationsThe set up consist of permeability cell, water reservoir and pressure lines, with glass bottles.
Permeability CellConsists of a metal cylinder with a ledge at the bottom for retaining the specimen, a flange at the top, removable cover plate and a funnel. A rubber gasket is seated in matching grooves, between the cell and the cover plate, to render the joint water tight. Internal working size of the cell will be 100mm dia X 100mm hight.
Water ReservoirConsists of a length of metal pipe, 50 to 100 mm in diameter and about 500 mm long. The reservoir fitted with a graduated side arm gauge-glass for admitting water and compressed air and a cock for drainage, bleeding and connection to the permeability cell.
Pressure LinesHeavy duty armored rubber hose with end fittings. Complete with glass bottles but without compressor. For specimen size 100 X 100 mm
Concrete permeability tester for three specimen of (100mm dia x 100mm height) or (150mm dia x 150mm height) or (150mm cube) is also available.Relavant Standard : IS : 3085
Optional AccessoriesThe fineness of cement has a significant effect in its physical properties when used in concrete. Generally the finer the cement powder, the more rapid the concrete will set, as there is an increase in its surface area. The measure of fineness is usually undertaken by sieving, and the result assessed against the cement standard for compliance.
The Blaine air permeability apparatus is used to determine the fineness of Portland cement in terms of the specific surface expressed as total surface area in square centimeters per gram of cement. The Blaine apparatus draws a defined volume of air through a prepared bed of cement of defined porosity.
The apparatus comprises one each of Brass or stainless steel permeability cell 12.5mm, 'U' tube manometer with stop cock mounted on a laminated wooden stand, perforated metal disc, plunger, Rubber stopper, Rubber tube - 30cm long with rubber bulb.
Optional AccesorriesAt extra cost
Mechanical screw loading jack, 10, 000 Kg. Capacity with U-bracket and swivel head. Penetration piston, 50mm dia threaded at the upper end. Extension rods set consisting of length 50cm, and 1 length 100cm., used as spacers between the proving ring and penetration piston. The lengths are machined from steel tubing.
Connector set, has eight connectors for coupling the penetration piston and proving ring assembly either directly or through extension pieces.
Dial gauge support of seamless pipe construction. It stands 30cm high and 45cm wide at the base. Provided with a quick release screw type clamp capable of sliding and locking anywhere along 2 meter length of the bridge. Supplied with annular metal weight 5Kg. 250mm dia with 53mm dia central hole, slotted metal weight 5 Kg, 215mm to 250mm dia with 53mm dia slot, 3 Nos, Slotted metal weight, 10Kg, 215mm to 250mm dia with 53mm dia slot. 2Nos.
Consist of the following.
DEAN & STARK APPARATUS FOR ESTIMATION OF MOISTURE IN TAR & BITUMENS
The apparatus consist of 500 ml heat resistant glass with neck having ground glass joint, a condenser made of heat resistant glass as per fig. 2 of IS 1211, receiver - also made of heat resistant glass with ground glass joint leading to the flask and graduated tube. Capacity of receiver will be 2 or 10 ml. (please specify while ordering - or else 2 ml receiver shall be supplied)
Similar to Mechanical Model but with Electronic Outfit in place of Proving Ring and Dial Gauge
Outfit consists of
Display | The decimal display point is positioned by the channel selector switch. |
Power | 220 V ± 10% mains, 50 Hz, single Ph. AC supply. |
No. of channels | 3 |
Parameter display | By a selector switch. Load Cell - 1 No. |
Capacity | 2 KN (200 kgf) Universal type, TCPR |
Max. Overload | 110% of the rated capacity |
Sensing Element | Strain Gauges in full bridge configuration. Displacement Sensor - 2 Nos. |
Range | ± 19.99 mm |
Sensing Element : | LVDT Complete as above |
The oldest, most widely used test for determining workability. This test is used to determine the workability of fresh concrete, which would normally be undertaken at the point of delivery to ensure the concrete, is of adequate consistency for placement. The test is applicable to concrete of medium workability.
The device is a hollow cone-shaped mould. The mold is filled in three layers of each volume. Each layer is rodded with a 16mm steel rod 25 times. The mould is then lifted away and the change in the height of the concrete is measured against the mould. The slump test is a measure of the resistance of concrete to flow under it own weight.
General Description and specifications :
The apparatus comprise of a slump cone with handles made of mild steel sheet, a chrome plated steel tamping rod of 16 mm diameter X 600 mm long, rounded off at one end, with a scale marked on it and a steel base plate with a carrying handle.
The mould for the test specimen will be in the form of frustum of a cone having the following internal dimensions as follows
The Cone is constructed of metal of at least 1.6 mm thickness and the top and bottom are open and at right angles to the axis of the cone. The mould have a smooth internal surface and provided with suitable foot pieces to a base plate and also handles to facilitate lifting it from the moulded concrete test specimen in a vertical direction as required by the test. The base plate is provided with cleats & swivel handle.
Optional Accessories :Used to determine initial and final set times of Portland cement, masonry cement, hydraulic hydrated lime and certain mortars.
DetailsThe vertical support shaft has a device to maintain the horizontal arms in alignment. The support assembly is adjustable. The two steel needle weights are calibrated to meet specifications. The needle points are manufactured from stainless steel. The initial setting needle is 2.12mm in diameter and weighs 113 grams. The final setting needle is 1.06mm in diameter and weighs 453.6 grams.
ASTM C430
ApplicationsWet Sieving Apparatus is used for determining the fineness of fly ash.
DetailsThe apparatus comprises of following parts and accessories
It is used to determine the amount of carbon deposit when an oil is evaporated under specified condition. The Carbon Residue values of crude oil, residue etc. are useful in the manufacture of various lubricants. The apparatus consists of Spun Sheet Iron Crucible 25 cc capacity, sheet hood and sheet iron block on a stand, gas Burner
As per IS 1210 without thermometer.
This is widely used for determination for closed cup Flash Point of Fuel Oil, cut back asphalts, other viscous material and suspension of solids having a flash point above 490C (1200F).
General Descripation & SpecificationsThis apparatus is made as per IP 34. ASTM D-93 and IS 1209-1978 method B. The apparatus consists of brass test cup with handle, removable cup cover with spring operated rotating shutter having Oil Test Jet/Gas Test Jet Flame Device. Stirrer with flexible shaft. The assembly rests in air bath, which is covered, with dome shape metal top. The cup is fitted with insulated handle and locking arrangement near cup flange. The assembly is kept on round shaped electric heater with Energy regulator temperature control. Suitable for operation on 220 Volts 50 cycles AC .
Optional AccessoriesThe following accessories are not part of the standard supply and supplied at an extra cost.
Used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The time it takes for a cement to stiffen to a standard value after addition of water is commonly known as the set time. The test involves mixing cement with water and then measuring its resistance to penetration of a standard probe at varying intervals of time, until a certain value is reached.
J-ring test the passing ability of the concrete .The equipment consists of rectangular section of 38 mm X 25 mm open steel ring drilled vertically with holes to accept threaded section of reinforcing bars 12 mm diameter 100 mm in length.The bars and sections can beplaced at different distance apart to simulate the congestion of reinforcement of the ring formed by vertical section is 300 mm and height 100 mm .
Equipments :Consists of panel for wall mounting on which are fitted wall mounting on which are fitted 1.0 to 10Kg/cm2 x0.1Kg/cm2 a pressure gauge, Bourdon tube 20cm dia.
ManometerGlass U-tube manometer for measuring low positive pore pressures negative pore pressures and checking zero error of pressure gauge. It is provided with a mercury trap (Mercury supplied at extra cost ) Null indicator made out of clear transport perspex with mercury trap and cursor to indicate the mercury level.
Burette50 ml Burette for measuring the volume change in the soil specimen. Pressure pump fitted with four sleeve packed valve, Operated by means of a hand wheel on the end of the piston rod which is threaded thru the pump cap and gives a smooth, fine adjustment of pressure copper coil and water reservoir.
The unit is tested against leaks upto 10Kg/cm2
Complies with following International Standards
ASTM D1833-99
Salient Features
Supplied Complete with following accessories and parts
Salient Features of Digital Readout Facility
Optional Accessory at Extra Cost
1) With PC/printer interface & software connectivity for direct printout of calculated results
Complete with Load frame, Hand Operated/Electrically Operated 5000 Kg capacity, C.B.R. Mould, Penetration Piston, Perforated Plate, Displacer Block, Anuular/Slotted Metal Weight 2.5 kg, Metal Tripod Stand, Rammer 2.6 kg/4.89 kg., with Calibration Certificate.
Optional Accessories :The equipment comprises a vibratory table 75mm x 75mm motorised 230 Volts, single phase A.C. cylinderical mould 3000 cm3 and 15000 cm3, guide sleve with clamp for moulds, surcharge base plate, surcharge weight for 3000 and 15000 cm3, handle for base plate, dial gauge holder, dial gauge 0.01 mm x 25 mm travel with extension piece calibration bar 75 x 300 x 3mm.
Consists of gunmetal mould 100mm dia X 127.3mm height X 1000ml volume, with collar of 100mm dia X 60mm high and drainage base plate, Drainage cap, Metallic clamping ring, two porous stone for base and cap, Dummy plate, air release valve. With a set of three glass stand pipes approx.6mm, 10mm, and 20mm dia X 1 meter length mounted on a wooden board, the end of the glass tube is serrated to connect rubber tube of 3 meter length with pinch cock.
The outfit comprises the following.
High sensitivity Proving Ring, 250 kg or 500 kg fitted with 0.002 mm dial gauge with certificate in a nice wooden carrying case.Dial Gauge 0.01mm x 25mm travel.
Proving ring type. Comprises of a hand operated load frame, cap. 30KN (3000 kgf.) screw jack for loading, handle and strain dial gauge bracket, adaptor for proving ring, conical seats and male/female coning tools for 38 mm dial samples. Supplied without proving ring and dial gauge.
Motorised Cum Hand OperatedComprises a screw operated load frame capacity 50 KN (5000 kgf.) with a gear box and motor drive giving 1.25, 1.5 and 2.5mm/min, rates of strain, pair of cone seating, adaptor for proving ring and strain dial gauge bracket. Supplied with one pair of male/female coning tools for 38 mm dia samples but without proving ring and dial gauge. Suitable for operating on 230 volts, single phase AC Supply.
It is a motor driven mechanical compactor useful for soil compaction into 100mm or 150mm dia moulds. Two sets of rammers are provided, one of 2.6kg. And the other of 4.89 kg arranged for 310mm and 450mm fall respectively. For compaction soil into 150mm dia moulds, 100mm face dia rammers having weight of 4.89Kg is used. Where as for 100mm dia moulds, they are of 50mm dia. The rammer assembly is provided with a ratchet and pawl arrangement to lift it from the top of the soil layer. When the rammer reaches the required height the pawl release the rammer, which falls freely on soil surface. The release mechanism is connected by an arm moving up and down which is connected to a reduction gear coupled to the motor through another arm. An automatic blow counter fitted to the compactor is used to set the number of blows. The base plate of the specimen mould is to be fitted to the rotating base plate of the instrument which makes 1/5th revolution per operation. Operation on 230 volts, 50 cycles, single phase, A.C. supply, Moulds are to be ordered separately.
Moulds for aboveProctor mould, 150 mm dia X 127.3 mm high X 2250cc volume with collar & base plate. Mild Steel.
Complete aluminium die cast model. Attractively painted. Aluminium block accepts 3 capillaries and a mercury thermometer, Max. temperature about 300 deg. C. Fitted with energy regulator. The samples are illuminated by and viewed through a magnifying lens.
An analytic apparatus that employs a manometer to determine changes in the amount of gas produced or absorbed by a test sample kept at constant temperature in a flask of constant gas volume and is used especially in the study of cellular respiration and metabolism and of some enzymatic reactions (as fermentation)
Polished Stainless Steel tank, with capacity of 7 manometers a side. Digital temperature display with resolution of 0.1 deg. C. Temperature control to within +/-0.5 deg. C. Stainless Steel immersion heater. Stirrer for uniform temperature. Manometers mounted on graduated scale for reading pressure changes. Flask with center well & side flask attached to manometer. Oscillation of manometer approximately 90 rpm. Powder coated exterior, with wheels for easy mobility. Capacity 7 manometers, temperature range of 5 deg. C above ambient to 60 deg. C.
The equipment is assembled in a mild steel cabinet attractively painted. A central shaft carries a platform with the glass cylinders of 50 ml. each. The platform with the glass cylinders moves up and down at 30 strokes per minutes through a distance of 5 cm and strikes on rubber cushioned bed. Electrically operated, supplied with time switch 0-15 minutes.
Used for tablets to determine the durability at the time of production. A transparent plastic persperx drum with cover also a shaped radial fixed blade which carries the tablets alongwith it upto the central height and lets them off while the drum is rotating, thus the tablet rub against each other without any hard impact. The drum rotates at a fix speed of 30 RPM by a geared motor. The rotation period is determined by a Electric Timer. Tablets are weighed before and after the test and the difference in weight for a perticular time period indicating the rate of abrasion. Complete with Electric Timer with neon indicators fitted on a panel.
Used to check and maintain the slope of the road as per design.
Material | Aluminum section of size 24 mm x 45 mm of thick gauge. |
Size | 3 meter, 3.5 meter, 3. 75 meter or as per requirement. |
Ratio | 2.0%, 2.5%, 3.0% or as per requirement. |
Accessories | Highly sensitive magnetic spirit level and seat for it at centre. |
Used for the measurement of resistance to plastic flow of cylindrical specimens of bituminous paving mixtures when tested in a marshal load frame. Test specimens are produced and tested at a speed of 50.8mm/min.The maximum load(stability) and deformation(flow) of the specimen are recorded. Generally the test is applicable to hot mix designs using bitumen and aggregate of maximum size of 25mm. Widely used for designing and evaluating bituminous paving mixes.
General Descripation & SpecificationsThe apparatus consist of the following
Load FrameA floor standing compression loading frame of 50 KN capacity with motor and worm gear housed within the base unit, producing a platen speed of 50.8mm/min. Limit switches are provided to cut out the platen over run on the downward travel. A handle is provided for manual operation during calibration etc. The load frame is fitted with ON/OFF/Reversing switch and power indicator lamp in front. Suitable to work on 230V, 50 Hz, AC single phase. .
Marshal Moulds (3 Nos.)4dia X 3 height specimen moulds, base plates and Extension collar. Manufactured from steel.(6 dia mould can be supplied at extra cost)
Compaction PedestalComprising of a hard wood block with a steel plate, complete with specimen holder, semi circular base and a circular top to hold 4 dia specimen mould in place during compaction of the specimen. (Pedestal to accommodate 6 dia specimen can be supplied at extra cost)
Compaction Hammer (2 Nos.)Designed for use with the compaction pedestal and mould. The hammer has a falling weight of 4.535 kg and free fall of 457 mm.
Breaking Head AssemblyConsisting of upper and lower cylindrical segments with provision for fixing flow meter. Suitable to take 4 dia specimens. ( Assembly to accommodate 6 dia specimen can be supplied at extra cost)
Specimen ExtractorConsisting of a load transfer bar, pressure plate and steel ball
Optional AccessoriesThe following accessories and consumables are not part of the standard supply and are mandatory for the testing work
The following additional Instruments will speed up the testing process with ease and accuracy
Sample Extractorallows the marshal sample to be easily removed from the mould. Can also be used for Proctor Moulds and Core cutters.
Optional AccessoriesThe following accessories and consumables are not part of the standard supply and are mandatory for the testing work
Distillation apparatus as per method D as per IS 1213 for creosote oil and anthracenet oil (without thermometer). Complete with one 150 ml. flask, one 100 ml. crow receiver.
This apparatus is meant for determination of softening point of bituminous materials according to IP 58 and IS 1205. Softening point is that temp. at which the specimen under test becomes soft enough to allow a steel ball of specific dimension to fall a required distance under test condition.
General Descripation & SpecificationsThe apparatus consist of Glass beaker of heat resistant glass of internal dia 8.5 cm X 12 cm depth (approx.), Two steel balls each of 9.5mm dia. (Weighing 3.50 + 0.05gm). Two tapered brass moulds, Two ball guides, ring stand. Supplied with a heating unit designed to give temp. rise at 50C per minute as required under standard. The temperature is controlled with an energy regulator. In addition, there is an electrically operated stirrer mounted on a stand with chuck and glass rod or aluminum rod and for stirring the water in the water bath. Operation on 230 Volts. single phase, 50 Cycles, AC.
Optional AccessoriesThe following accessories are not part of the standard supply and supplied at an extra cost.
Consists of one cone, plain 50 mm base dia and cone angle 60, one cone adaptor, guide pipe assembly with one end cap and one driving head with threads for 'A' rod coupling. Tripod stand 6 meter height with built in ladder with pulley arrangements. Drive weight 65 kg fitted with chain. As per IS : 4968 (Part I)
Optional Accessories :'A' drill rod, 1.5 meter long, one side male thread and the other side female.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Packaging Details : Plywood packing with robust foundation at base
Delivery Time : 3-4 weeks after receipt of firm order
Also called Softening Point Apparatus. This apparatus is meant for determination of softening point of bituminous materials according to IP 58 and IS 1205. Softening point is that temperature at which the specimen under test becomes soft enough to allow a steel ball of specific dimension to fall a required distance under test condition. The apparatus consists of Glass beaker of heat resistant glass having internal diameter of 8.5 cm X 12 cm depth (approximately), two steel balls each of 9.5mm diameter, two tapered brass rings, two ball guides, ring stand and a hand stirrer.
Electrically OpertaedSame as above but Electrically Operated.
(without thermometer) complete with one 1000 mililiter flask and one 100 mililiter crow receiver.
This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.
General Descripation & Specifications :The apparatus consists of a cup, heating plate, thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner, heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase.
Optional Accesories :Used for the measurement of resistance to plastic flow of cylindrical specimens of bituminous paving mixtures when tested in a marshal load frame. Test specimens are produced and tested at a speed of 50.8mm/min.The maximum load(stability) and deformation(flow) of the specimen are recorded. Generally the test is applicable to hot mix designs using bitumen and aggregate of maximum size of 25mm. Widely used for designing and evaluating bituminous paving mixes.
General Descripation & SpecificationsThe apparatus consist of the following
Load FrameA floor standing compression loading frame of 50 KN capacity with motor and worm gear housed within the base unit, producing a platen speed of 50.8mm/min. Limit switches are provided to cut out the platen over run on the downward travel. A handle is provided for manual operation during calibration etc. The load frame is fitted with ON/OFF/Reversing switch and power indicator lamp in front. Suitable to work on 230V, 50 Hz, AC single phase. .
Marshal Moulds (3 Nos.)4dia X 3 height specimen moulds, base plates and Extension collar. Manufactured from steel.(6 dia mould can be supplied at extra cost)
Compaction PedestalComprising of a hard wood block with a steel plate, complete with specimen holder, semi circular base and a circular top to hold 4 dia specimen mould in place during compaction of the specimen. (Pedestal to accommodate 6 dia specimen can be supplied at extra cost)
Compaction Hammer (2 Nos.)Designed for use with the compaction pedestal and mould. The hammer has a falling weight of 4.535 kg and free fall of 457 mm.
Breaking Head AssemblyConsisting of upper and lower cylindrical segments with provision for fixing flow meter. Suitable to take 4 dia specimens. ( Assembly to accommodate 6 dia specimen can be supplied at extra cost)
Specimen ExtractorConsisting of a load transfer bar, pressure plate and steel ball,
Optional AccessoriesThe following accessories and consumables are not part of the standard supply and are mandatory for the testing work
The following additional Instruments will speed up the testing process with ease and accuracy
Sample Extractorallows the marshal sample to be easily removed from the mould. Can also be used for Proctor Moulds and Core cutters.
Optional AccessoriesThe following accessories and consumables are not part of the standard supply and are mandatory for the testing work
Automatic Compactor to simulate hand compaction
Motorised Planetary mixer
Comprises of a frame designed for screw jack operation, one each of the adaptor plates and plunger adaptors for 38mm, 75mm, diameter, 100mm diameter, 150mm diameter, specimens and a stand to obtain simultaneously three 38mm diameter samples from one 100mm diameter sample. The adaptor plate which slides a long the slotted supports can be clamped at any desired position by means of locking nuts. Beside this, the tube or mould can be held in position by raising the tube guides and held in position with locking screws. the lead screw movement can be stopped at any predetermined position by tightening the lead screw locking collar. Plunger adaptor for 200mm dia samples. Adaptor plate with 200mm dia hole and device to extract 3 number 38mm dia samples.
With Individual Energy Regulator
One single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
EIE-5101 (G) For 6 Test UnitsWith Individual Energy Regulator
One single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
The compaction factor is defined as the ratio of the mass of the concrete compacted in the compaction factor apparatus to the mass of the fully compacted concrete. It involves dropping a volume of concrete from one hopper to another and measuring the volume of concrete in the final hopper to that of a fully compacted volume. The results of the compaction factor test can be correlated to slump, although the relationship is not linear. This test is difficult to run in the field and is not practical for large aggregates (over 1 inch) Compared to the slump test, the apparatus is bulky and a balance is required to perform measurements.
General Descripation & SpecificationsTThe apparatus, consist of a rigid frame that supports two conical hoppers vertically aligned above each other and mounted above a cylinder. The top hopper is slightly larger than the bottom hopper, while the cylinder is smaller in volume than both hoppers. To perform the test, the top hopper is filled with concrete but not compacted. The door on the bottom of the top hopper is opened and the concrete is allowed to drop into the lower hopper. Once all of the concrete has fallen from the top hopper, the door on the lower hopper is opened to allow the concrete to fall to the bottom cylinder. The excess concrete is carefully struck off the top of the cylinder and the mass of the concrete in the cylinder is recorded. This mass is compared to the mass of fully compacted concrete in the same cylinder achieved with hand rodding or vibration. Complete with trowel and tamping bar 0-60 cms long X 16mm dia.
Optional Accessories: