Our Products
Air Compressor
2 Products availableFreezers, Refrigerators And Chillers
2 Products availableIndustrial Blowers, Coolers & Fans
2 Products availableAir Compressors, Accessories & Parts
1 Products availableHorticulture & Gardening Tools
1 Products availableWe offer the best product range of Semi Hermetic Chillers and Sprinkler Fan.
Temperature Range:
Door :
Floor Type:-
Insulation material:-
Features:
Applications
Our enterprise has gained immense recognition in manufacturing, exporting and supplying a quality assured array ofAir Washer.Our offered washer is widely used for removing dust particles from the air. The washer provided by us is manufactured by making use of excellent grade components with the aid of advanced techniques in line with international quality standards. Apart from this, clients can avail thisAir Washerfrom us at rock bottom prices.
Features:
Specifications:
Capacity Availiable for Air Washer : 2000 to 40000 CFMwith single Blower &4000 to 80000 CFM withSingle & multiple blowers
Base Frame of Air Washer: The total assembly is mounted on a horizontal member of heavy Mild steel channel.
Air Washer Fan Section : Constructed inGI/SS Sheet with Inspection Doors.
Wet Section : Constructed inGI/SS Sheet.
Water Tank Structure of Air WasherConstructed inGI with Frpcoated/SS
Air Washer Blower : Dynamically Balaced Forward Curved, DIDW Type Make DRYCOOL / Imported.
Cellulose Paper Pad :Imported HUTEK, Munters
Air Washer Electric Motor : Three Phase, TEFC squirrel cage induction motor ofstandard makes (Crompton, ABB and Kirloskar etc.).
Drive Pulley : V-Groove with/without Taper Lock hub.
V-Belts : Fenner make.
Pump: Monoblock make Crompton / Kirloskar.
Filter used in Air Washer: HDPE/Aluminum/GI Mesh Filter, Micro Vee, Hepa as per requirement.
Pipe Fittings in Air washer : PVC piping with all Necessary fittings such asfloatvalve, quick fill, overflow &drain ports.
Specifications
Mode; | CFM | Blower Size in (mm) | QTy. | MOtor HP | Pump HP | Electric KWH | Water LPH | Size WxLxH (Ft.) |
---|---|---|---|---|---|---|---|---|
DECS-5 | 5000 | 450 | 1 | 1.5 | 0.25 | 1.1 | 50 | 3.6x7.0x5.5 |
DECS-6 | 6000 | 500 | 1 | 2.0 | 0.25 | 1.5 | 60 | 3.6x7.0x5.5 |
DECS-8 | 8000 | 560 | 1 | 3.0 | 0.5 | 2.0 | 80 | 4.0x7.0x5.5 |
DECS-10 | 10000 | 610 | 1 | 5.0 | 0.5 | 3.7 | 100 | 5.0x7.0x5.5 |
DECS-12 | 12000 | 610 | 1 | 5.0 | 0.5 | 3.7 | 120 | 6.0x7.0x5.5 |
DECS-16 | 16000 | 630 | 1 | 7.5 | 1.0 | 5.5 | 160 | 7.0x8.0x6.5 |
DECS-20 | 20000 | 710 | 1 | 10.0 | 1.0 | 7.5 | 200 | 8.0x8.0x7.0 |
DECS-25 | 25000 | 800 | 1 | 12.5 | 1.0 | 11.5 | 300 | 10x8.5x7.5 |
DECS-30 | 30000 | 900 | 1 | 15.0 | 1.0 | 11.5 | 300 | 12x8.5x7.5 |
DECS-40 | 40000 | 1000 | 1 | 20.0 | 1.0 | 15.0 | 300 | 13x9.0x8.0 |
DECS-45 | 45000 | 1000 | 1 | 20.0 | 1.0 | 15.0 | 360 | 15x9.0x8.0 |
DECS-50 | 50000 | 1000 | 1 | 25.0 | 1.0 | 18.7 | 380 | 16x9.0x8.0 |
In this write up, an energy-saving device is introduced into the air-handling unit (AHU). Due to increases in energy costs, energy saving devices or systems have become the new preferred trend in tropical countries. A primary cooling coil system is incorporated into the AHU to recycle the condensate water in order to achieve energy savings. The warm outside fresh air is drawn through the primary cooling coil to recover the latent heat of condensate water. The large temperature gradient between the warm fresh air and condensate water enlarges the amount of energy recovered. This system is well applicable to primary AHU which serves primary air to the airconditioning system. The cost of installing the device is negligible but in returning long term saving. Furthermore, the de-cooled condensate water can be drained off through non-insulated drain pipe. The idea generation is discussed in the introduction. Chapters 2 and 3 describe the preliminary calculation of the energy saving percentage. Chapter 4 shows the detailed theoretical study of the development of the energy saving system. This shows the viability of the idea. Chapter 5 will recommend the design of the primary cooling coil configuration to achieve the desired cooling effect and energy saving strategy. Lastly, the conclusion of the whole study is presented.
In tropical countries such as the United Arabia Emirates (UAE) and Malaysia, the climate is always hot and highly humid throughout the year. Lots of energy is consumed for Air-Conditioning and Mechanical Ventilation (ACMV) systems.
For buildings such as hotels and hospitals, energy is used to cool down the fresh air in the primary AHU and pumped into the building to achieve the internal air quality required. Due to the high humid climate, lots of condensed water is drained away as a by-product. However, the cooled condensate water actually consumes 2% of the total cooling load of the system on average. Here, we are studying the recovery of the condensed water in which the 2% energy can be saved. 2% of energy for a system running 24 hours a day can make a significant reduction for the operating cost.
The condensed water is first collected by the condensate drain pan below the main secondary cooling coil. Then, the collected condensed water is pumped into the primary cooling coil for the de-cooling process.
In order to maximize the energy recovery, a primary cooling coil is recommended to be installed at the fresh air intake opening of the AHU where the temperature gradient between the air outside and condensate water is greater, rather than at the side in which air returns or at the mixing plenum.
Specifications
Model | CFM | Fan Model | Coil Area (Sq Mtr.) | Height (mm) | Weight (mm) | Depth (mm) |
---|---|---|---|---|---|---|
DDSH-018 | 1100 | 180 | 0.20 | 750 | 900 | 1150 |
DDSH-028 | 1400 | 200 | 0.26 | 800 | 900 | 1200 |
DDSH-029 | 1800 | 225 | 0.33 | 800 | 1000 | 1300 |
DDSH-037 | 2200 | 250 | 0.41 | 900 | 1100 | 1400 |
DDSH-046 | 2800 | 280 | 0.51 | 1000 | 1375 | 1450 |
DDSH-059 | 3500 | 315 | 0.65 | 1000 | 1375 | 1450 |
DDSH-068 | 4000 | 355 | 0.74 | 1100 | 1375 | 1600 |
DDSH-074 | 4400 | 355 | 0.82 | 1100 | 1425 | 1600 |
DDSH-085 | 5000 | 400 | 0.94 | 1200 | 1425 | 1700 |
DDSH-093 | 5500 | 400 | 1.02 | 1200 | 1550 | 1700 |
DDSH-102 | 6000 | 450 | 1.12 | 1300 | 1550 | 1800 |
DDSH-115 | 6800 | 450 | 1.26 | 1300 | 1650 | 1800 |
DDSH-130 | 7700 | 500 | 1.43 | 1400 | 1900 | 2000 |
DDSH-144 | 8500 | 500 | 1.58 | 1400 | 1900 | 2000 |
DDSH-161 | 9500 | 560 | 1.77 | 1500 | 1900 | 2200 |
DDSH-183 | 10800 | 560 | 2.01 | 1500 | 2050 | 2200 |
DDSH-204 | 12000 | 630 | 2.23 | 1600 | 2050 | 2300 |
DDSH-229 | 13500 | 630 | 2.51 | 1600 | 2350 | 2300 |
DDSH-255 | 15000 | 710 | 2.79 | 1750 | 2350 | 2550 |
DDSH-289 | 17000 | 710 | 3.16 | 1750 | 2650 | 2550 |
DDSH-340 | 20000 | 800 | 3.72 | 2000 | 2650 | 2700 |
DDSH-365 | 21500 | 800 | 4.00 | 2000 | 2800 | 2700 |
DDSH-425 | 25000 | 900 | 4.65 | 2250 | 2800 | 2900 |
DDSH-459 | 27000 | 900 | 5.02 | 2250 | 3000 | 2900 |
DDSH-570 | 30000 | 1000 | 5.58 | 2500 | 3000 | 3000 |
DDSH-578 | 34000 | 1000 | 6.32 | 2500 | 3000 | 3000 |
Owing to our years of industry experience, we are engaged in providing our clients a wide range of high quality PVC Fill. Offered product is widely used in various places as per their precise needs of applications. Manufactured by skillful professionals using finest quality raw materials and most recent technology in order to meet the set industry quality standards, we offer this product at the most affordable rate to the clients. Honeycomb type PVC fills are used for extended contact area having a high heat transfer efficiency. The crossing of air and water stream in close proximity. Which creates a diffused turbulence conducive to evaporation and efficient heat transfer, all PVC fills are double folded with an automatic drainage system, producing a favorable pressure drop and a good protection against erosion. They are glued by automatic process and manufactured with German design ensuring a maximum drift of 0.001% under standard design conditions. The sub distribution pipes are made of rigid PVC with a testing pressure of 6 Kg/cm2.
Features:
Drycool with its exceptional thermal performance and fatigue resistance, the compact-sized DRYCOOL Shell & Tube heat exchanger opens up a whole new world of possibilities. Designed for use with liquids, gases and two-phase mixtures at pressures up to 100 bar (1450 psi), in both PED and ASME, and at temperatures up to 450C (842F), DRYCOOL Shell & Tube is suitable for a wide range of aggressive media.
The DRYCOOL DM model is a dry-expansion shell-and-tube evaporator developed for medium temperature refrigeration applications.The DM design is optimized for R407F and R134a refrigerants, but can also be utilized with R404A and R507.
Our precision range of Water Cooled Screw Chiller Multiple Compressors is of world class quality and is fabricated in our state-of-the-art manufacturing unit having an option of using CFC free refrigerants r-407c & r-134a complete with in-built process pump and stainless steel chilled water expansion tank. These chillers are rated for an ambient of up to (+) 50c and cooling tower water temperature up to (+) 37c at the inlet of the condenser. Our range is manufactured using reputed screw compressors from bitzer (Germany) and frascold (Italy). Fully microprocessor based, these chillers are suitable for process cooling applications from (+) 20c upto (-) 40c. We offer these multiple screw compressors in one machine but having separate and individual refrigeration circuits.
The Air Cooled Chillers are suitable for working in extreme tropical weather conditions with maintaining energy and operational efficiency. The equipment is designed and manufactured in compliance with superior designing and manufacturing standards. The environmental friendly chillers are easy to install and are tested on all the required international parameters to be at par with the best.
Drycool with its exceptional thermal performance and fatigue resistance, the compact-sized DRYCOOL Shell & Tube heat exchanger opens up a whole new world of possibilities. Designed for use with liquids, gases and two-phase mixtures at pressures up to 100 bar (1450 psi), in both PED and ASME, and at temperatures up to 450°C (842°F), DRYCOOL Shell & Tube is suitable for a wide range of aggressive media.
The benefits of DRYCOOL Shell & Tube:
The features of DRYCOOL Shell & Tube:
We are offering Water Cooled Scroll Chiller which are fabricated with globally renowned scroll compressors from danfoss-maneurop and Copeland. Our range of chillers is fully microprocessor based and suitable for process cooling applications from (+) 20c up to (-) 15c and for lower temperatures of up to (-) 50c please refer brine chillers. Offered with multiple scroll compressors in one machine but having separate and individual refrigeration circuits, these chillers are also rated for an ambient of up to (+) 480c and cooling tower water temperature up to (+) 37c at the inlet of the condenser. We manufacture our range in an ISO 9001 certified unit, with an option of using CFC free refrigerant r-407c & r-134a complete with in-built process pump and stainless steel chilled water expansion tank.
The Air-cooled Scroll Chillers are highly energy efficient and are perfectly designed to work within extreme tropical weather conditions. Supported with European origin compressors, these chillers are designed, manufactured and tested in conformation with international industrial standards. The chillers are operation friendly, easy to install and backed by competent engineering team to realize the advantage while being in operation.
Within a multiple compressor configuration, each compressor is supported by an individual and separate refrigeration circuit. The separate refrigeration circuit makes the servicing of under-maintenance modules easy, simultaneous to working module being on duty. The equipment is compact and contains fluid pump as well as storage tank on skid.
Cold Room Panels :
Performance Data :
General :
With our rich industry experience and knowledge, we are engaged in offering high quality Sprinkler Fan. Precisely manufactured by our experienced professionals using quality accepted raw material in conformity with industry standards, we offer this fan in various specifications as per the precise needs of clients. Also, this fan is checked on numerous quality parameters to ensure its durability and reliability. Fan is not aerodynamic design, axial flow type to achieve better efficiency. MK's Fan is made of adjustable FRP/Aluminum alloy blades that ensure large airflow at low static pressure, thus fan blades can change fan power consumption.
Features:
Drycool is a world class producer of air filtration products. With a wide variety of product offerings, air filters provide superior air quality to almost every compressed air application in the industry.
F-Series advanced compressed air filters are rigorously tested and engineered with superior components to provide years of reliable performance for high quality air.
Specifications
With our rich industry experience and knowledge, we are engaged in offering high quality Flange Motor. Precisely designed and manufactured by knowledgeable professionals using quality accepted components and latest techniques in conformity with industry standards, we offer this motor in different stipulation and can also be custom designed as per the precise needs of clients. Also, offered motor is meticulously tested on different quality parameters to ensure its high problem free performance at client end. Special low RPM totally enclosed motors of vertical, flange type with enlarged and threaded shaft and sealed top supplied with the cooling tower, the motor is totally weather proof in IP 55 construction suitable for heated and humid atmosphere.
Features:
Technical Specificatioons
Air -Cooled Scroll Chiller | |||||
---|---|---|---|---|---|
model | compressor model | chilled water temperature 10'c | dimension lxwxh in mm (appx) | weight kg (appx) | |
capacity | connected load (compr. only) | ||||
dc-asc-3 | cr-42 | 3 tr | 3.5 kw | 900 x 800 x 1200 | 310 |
dc-asc-5 | zr-72 | 5 tr | 5.3 kw | 1200 x 800 x 1600 | 410 |
dc-asc-8 | sm-120 ( mt-100) | 8 tr | 9.1 kw | 1800 x 1200 x 1800 | 640 |
dc-asc-10 | zr-144 | 10 tr | 10.6 kw | 1800 x 1200 x 1800 | 760 |
dc-asc-10 | zr-72 x 2 nos | 10 tr | 10.6 kw | 1800 x 1200 x 1800 | 790 |
dc-asc-16 | sy-240 | 16 tr | 18.3 kw | 1700 x 1900 x 2100 | 860 |
dc-asc-20 | sy-300 | 20 tr | 22.8 kw | 2200 x 1300 x 1600 | 940 |
dc-asc-20 | zr-144 x 2nos. | 20 tr | 21.2 kw | 1700 x 1900 x 2100 | 1360 |
dc-asc-32 | sy-240 x 2nos. | 32 tr | 36.6 kw | 1700 x 1900 x 2100 | 1510 |
dc-asc-40 | sy-300 x 2nos. | 40 tr | 45.6 kw | 2800 x 1900 x 2100 | 1990 |
dc-asc-64 | sy-240 x 4 nos. | 64 tr | 73.2 kw | 3200 x 1900 x 2300 | 2490 |
dc-asc-80 | sy-300 x 4 nos. | 80 tr | 91.2 kw | 3200 x 1900 x 2300 | 3060 |
dc-asc-6 | sm-084 (cfc free) | 6 tr | 6.2 kw | 1200 x 800 x 1600 | 410 |
dc-asc-12 | sm-084 x 2 nos.( cfc free) | 12 tr | 12.4 kw | 1800 x 1200 x 1800 | 790 |
dc-asc-18 | sm-084 x 3 nos.( cfc free ) | 18 tr | 18.6 kw | 2200 x 1300 x 1600 | 1190 |
Air receivers are tanks used for compressed air storage and are recommended to be in all compressed air systems. Using air receivers of unsound or questionable construction can be very dangerous. Therefore, the American Society of Mechanical Engineers (ASME) has developed a code regarding the construction of unfired pressure vessels, which has been incorporated into many federal, state, and local laws. This particular code is ASME Code Section VIII Division 1. Air receivers should always meet or exceed this code in addition to any other state, municipal, or insurance codes that may apply.
Browse our selection of Air Receiver Tanks or call us toll-free: 866-650-1937 if you have any questions. Learn more with this helpful article about.
The ASME also approves the receiver accessories. They are equipped with a safety valve, which is set at a pressure lower than the working pressure for which the air receiver was stamped and at a higher pressure than the operating pressure, to safeguard against excessive pressure. In addition, receivers have a drain valve to eliminate accumulated moisture. They also have pressure gauges, handholes or manholes, and a base for vertical air receivers. Standard receivers are designed for horizontal or vertical mounting.
We are a remarkable entity, engaged in offering a high quality range of Rotary Sprinkler. Designed and developed in observance with industry standards using ultimate quality raw material, this sprinkler is stringently tested on various quality parameters by our professionals to avoid any kind of production defects. We offer this sprinkler in diverse stipulation at industry leading rates to the clients. Drycool specially designed rotary sprinklers head is made of aluminum alloy to avoid corrosion, also fitted with sealed ball bearing to take care of thrust and radial loads. It rotates at 1- RPM by the reaction force from the circulating water that is discharged at low pressure out of holes along PVC/HDPE pipes screwed into a rotating head.
Features:
We are an eminent entity engaged in offering an extensive range of Plate Heat Exchanger. The offered exchanger is precisely manufactured by our skilled professionals following high definition engineeringprinciples and utilizing premium quality components. This exchanger is tested properly against numerous parameters in order to deliver defect free range. Client can purchase the offered exchanger from us at economical prices.
Features:
When sudden large air demands occur, dry air receivers should have adequate capacity to minimize a drop in system air pressure. If these pressure drops were not minimized here, the performance of air dryers and filters would be reduced because they would no longer be operating within their original design parameters.The term "dry receiver" refers to the receiver placed after the air dryer and other air preparation equipment.
Air receiver sizing:
The size of the air receiver is dependent upon air usage and the compressor style. The general rule to size a air receiver is:
Wet receivers provide additional storage capacity and reduce moisture. The large surface area of the air receiver acts as a free cooler, which is what removes the moisture. Because the moisture is being reduced at this point in the system, the load on filters and dryers will be reduced. The term "wet receiver" refers to the storage vessel or tank placed immediately after thecompressor. This device helps with contaminant removal, pressure stabilization and pulsation reduction.