Our Products
Freezers, Refrigerators And Chillers
2 Products availableIndustrial Blowers, Coolers & Fans
2 Products availableAir Compressor
2 Products availableHorticulture & Gardening Tools
1 Products availableReciprocating Compressors
1 Products availableOur offered Product range includes Bottle Type Cooling Tower, Forced Draft Cooling Tower, Forced Draft Cooling Towers, Rectangular Cooling Tower and Square Type Cooling Tower.
Our Bottle Type cooling towers are of induced draft design, which is why these are more efficient than forced draft counter flow design. Using less power per cooling ton, our towers represent the latest development in the use of plastic technology. Using superior quality FRP materials in fabrication, we offer towers which have resistant to damages and also prevent corrosive effect of weather and chemicals. Our induced draft design consumes 50% less energy and it can easily cut city water and sewer bills by up to 97%, as water is re-circulated instead of being wasted. One can rely on our towers because our cooling tower provide dependable, trouble-free and satisfactory long-term service. Our cooling towers in fiber glass reinforced plastics provide economic outdoor dissipation of heat picked up by water in air conditioning & refrigeration, co
Technical Parmameters For Drycool Bottle Type Cooling Tower
Model |
Capacity TR |
Heat Rejection Kcal/Hrx 1000 |
Over all Dimensions |
Fan Dia (mm) |
Motor HP |
Operating weight Kg. |
Pump Head (mm) WC |
|
Height (mm) |
Diametert (mm) |
|||||||
DC- FRP-01 |
7.5 |
28 | 2000 | 900 | 600 | 1/2 | 210 | 1800 |
DC -FRP-02 |
15 | 56 | 2000 | 100 | 700 | 1 | 350 | 2000 |
DC -FRP-03 |
25 | 98 | 2300 | 1900 | 900 | 2 | 520 | 2500 |
DC FRP-04 |
30 | 115 | 2300 | 2200 | 900 | 2 | 600 | 2500 |
DC- FRP-05 |
40 | 160 | 2900 | 2200 | 1200 | 2 | 800 | 3000 |
DC- FRP-06 |
50 | 190 | 2900 | 2200 | 1200 | 2 | 900 | 3000 |
DCS FRP-07 |
60 | 225 | 2900 | 2900 | 1200 | 3 | 1200 | 3000 |
DC- FRP-08 |
80 | 320 | 3100 | 2900 | 1450 | 3 | 1500 | 3000 |
DCS FRP-09 |
100 | 380 | 3100 | 3250 | 1450 | 5 | 1650 | 3200 |
DC- FRP-10 |
125 | 470 | 3100 | 3250 | 1500 | 5 | 1850 | 3200 |
DCS FRP-11 |
150 | 568 | 3100 | 3400 | 1500 | 7.5 | 1950 | 3400 |
DC- FRP-12 |
175 | 658 | 3300 | 3400 | 1800 | 7.5 | 2200 | 3400 |
DC- FRP-13 |
200 | 755 | 3300 | 3800 | 1800 | 10 | 2300 | 3500 |
DCS FRP-14 |
250 | 940 | 3600 | 3800 | 1800 | 10 | 3400 | 3800 |
DC- FRP-15 |
300 | 1128 | 3600 | 4200 | 1800 | 10 | 3700 | 3800 |
DC- FRP-16 |
400 | 1550 | 3800 | 4200 | 3000 | 15 | 6000 | 4200 |
DC- FRP-17 |
500 | 1890 | 4100 | 6000 | 3000 | 15 | 6500 | 4500 |
A mechanical draft tower with a blower type fan at the intake. The fanforcesair into the tower, creating high entering and low exiting air velocities. The low exiting velocity is much more susceptible to recirculation. With the fan on the air intake, the fan is more susceptible to complications due to freezing conditions. Another disadvantage is that a forced draft design typically requires more motor horsepower than an equivalent induced draft design. The benefit of the forced draft design is its ability to work with highstatic pressure. Such setups can be installed in more-confined spaces and even in some indoor situations.
Backed by rich industry experience, we are offering an extensive range of Rectangular Type Cooling Tower. Precisely manufactured by our adroit professionals using premium quality raw material and most recent technology, this cooling tower is available in different technical specifications as per the precise requirements of clients. Also, offered cooling tower is tested on numerous quality parameters to ensure its flawless finish.
Our company is engaged in manufacturing a qualitative range of
FRP square type cooling towers
Which are offered to industry for process cooling . These are demanded by the users of process coolers, diesel engine, machine and air-conditioning plants.
Benefits:
Capacity: 5 Tones to 600 Tones in Single Cell/Multiple cell.
Technical Parmameters For Drycool Square Type Cooling Tower
We are offering following types of cooling towers:
Model |
Capacity TR |
Over all Dimensions |
Fan Dia (mm) |
Operating weight Kg. |
Pump Head (mm) |
Motor/Rpm HP |
||
Length (mm) |
Width (mm) |
Height (mm) |
||||||
DCS FRP-01 |
7.5 TR |
600 | 600 | 1950 | 450 | 150 | 1800 |
0.5/960 |
DCS FRP-02 |
10 TR |
750 | 750 | 2050 | 450 | 200 | 1800 | 1/960 |
DCS FRP-03 |
15 TR |
900 | 900 | 2100 | 700 | 275 | 2000 | 1/960 |
DCS FRP-04 |
20 TR |
1050 | 1050 | 2200 | 750 | 360 | 2000 | 2/1400 |
DCS FRP-05 |
30 TR |
1200 | 1200 | 2300 | 900 | 650 | 2400 | 2/960 |
DCS FRP-06 |
40 TR |
1200 | 1200 | 2300 | 900 | 650 | 2400 | 2/960 |
DCS FRP-07 |
50 TR |
1500 | 1500 | 2550 | 1200 | 850 | 2900 | 2/960 |
DCS FRP-08 |
50 TR |
1500 | 1500 | 2550 | 1200 | 850 | 2900 | 3/960 |
DCS FRP-09 |
60 TR |
1800 | 1800 | 2600 | 1350 | 1000 | 3100 | 3/960 |
DCS FRP-10 |
80 TR |
1800 | 1800 | 2600 | 1350 | 1200 | 3100 | 5/960 |
DCS FRP-11 |
100 TR |
2100 | 2100 | 2650 | 1450 | 1600 | 3300 | 5/960 |
DCS FRP-12 |
125 TR |
2400 | 2400 | 2650 | 1500 | 2050 | 3300 | 5/960 |
DCS FRP-13 |
150 TR |
2400 | 2400 | 2650 | 1500 | 2150 | 3300 | 7.5/960 |
DCS FRP-14 |
175 TR |
2700 | 2700 | 2850 | 1500 | 2300 | 3400 | 10/960 |
DCS FRP-15 |
200 TR |
3000 | 3000 | 2850 | 1800 | 3000 | 3500 | 10/960 |
DCS FRP-16 |
250 TR |
3000 | 3600 | 2850 | 1500x2 | 4000 | 3500 | 5/960x2 |
DCS FRP-17 |
300 TR |
3600 | 3600 | 2900 | 1800 | 4400 | 4300 | 10/960 |
DCS FRP-18 |
400 TR |
3000 | 6000 | 2900 | 1800x2 | 5000 | 4500 | 10/960x2 |
Backed by rich industry experience, we are offering an extensive range of Rectangular Type Cooling Tower. Precisely manufactured by our adroit professionals using premium quality raw material and most recent technology, this cooling tower is available in different technical specifications as per the precise requirements of clients. Also, offered cooling tower is tested on numerous quality parameters to ensure its flawless finish.
Features: