Our Products
Our Complete range of products are Model 670 Fume Hood Monitor, Model 660 Air Velocity Monitor and Particulate Monitor (Series DPM).
model 670 fume hood monitor
ensures proper fume hood performance
the model 670 fume hood monitor continuously senses air flow through the face of the fume hood, ensuring safe levels of fresh air are exhausting. The 670 provides a highly accurate hot wire sensor to detect very low flows common on fume hoods. The model 670 comes with everything required to quickly install the unit including a mounting bracket, 24" of tubing for connecting to the inside of the hood wall and a 120 volt ac power adapter.
product applications
fume hood ventilation monitoring
modeldescription
670fume hood monitor.
specifications
service:fume hood face velocity air flow.
alarm range:30-400 fpm (0.15-2.0 m/s).
alarm indication:red led & audible alarm.
low air velocity alarm delay:fixed 5 secs.
visual led display:red: alarm; green: normal.
horn silence:yes, temporary and permanent.
accuracy:face velocity 10%.
temperature limits:operating temperature: 55 to 86f (13 to 30c). Storage temperature: -40 to 150f (-40 to 65c).
power requirement:15 vdc 500 ma; 120 vac, 60 hz power transformer included.
relay output low air flow alarm:5 a @ 250 vac.
relay input for night setback:2 wire rated for 24 vdc usage.
sash high indication:using a two wire micro switch or 3 wire proximity switch input, rated for 24 vdc usage.
mounting:semi flush, flush or surface mounted when using included bracket.
weight:5.0 oz (141 g).
agency approval:ce.
features
flexible surface or flush mounting
led safe and alarm status indicators
audible alarm
sash alarm input
night set-back input
related products
model 480 vaneometer swing vane anemometer
model 480 vaneometer swing vane anemometer
series 641 air velocity transmitter
series 641 air velocity transmitter
series adps/edps differential pressure switch
series adps/edps differential pressure switch
Condition : New
Brand Name : DWYER USA
Voltage : 60 Hz Power Transformer Included.
Features : High Speed, Low Consumption
Type : Model 670 Fume Hood Monitor
Warranty : 1year
Color : Cream
Application : Fume Hood Face Velocity Air Flow.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Model 660 Air Velocity Monitor
continuously measures fume hood airflow
model 660 air velocity monitors are a practical, affordable way to continuously monitor for safe air flows through laboratory fume hoods. They are typically installed in the fume hood side fascia and connected to the interior sidewall via 1-18" flexible tubing. As the exhaust fan draws air through the device, a sensitive constant temperature thermistor measures flow and lights a green (normal), yellow (high) or red (low) led. An audible alarm also warns of low flow and requires manual resetting. Mounting holes fit standard single gang electrical box.
product applications : warns user if insufficient fume hood face velocity is encountered.
specifications
service:air and non-combustible, non-corrosive gases.
high setpoint range:0-275 fpm (0-1.397 m/s).
low setpoint range:0-150 fpm (0-.792 m/s).
repeatability:7% of full span, 0-50 and 150-275 fpm; 5% of full span, 50-150 fpm.
compensated temperature range:50 to 90f (10 to 32.2c).
operating temperature range:32 to 120f (0 to 48.9c).
power supply:24 vac, 3 watts maximum.
response time:6-10 seconds.
warm-up time:3-5 minutes (no flow).
audible alarm:75 db between 3-10 feet.
weight:3 oz (85 g).
mounting hardware:(2) #6 x 1" sheet metal screws, (2) 6-32 x 7/8" machine screws.
related products
model vt120 integral vane thermo-anemometer
model vt120 integral vane thermo-anemometer
model 480 vaneometer swing vane anemometer
model 480 vaneometer swing vane anemometer
model vt-200 vane thermo-anemometer
model vt-200 vane thermo-anemometer
Warrenty : 1 Year
Type : Air Velocity Meter
Color : Grey
Brand Name : DWYER USA
Certificate : YES
Usage : Industrial, Non-corrosive Gases.
Size : Standard
Power : 24 VAC, 3 Watts Maximum.
Voltage : 3 Watts Maximum.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Particulate Monitor (Series DPM)
series dpm particulate monitor
real-time leak gauge, adjustable alarm points
the dpm particulate monitor and pms particulate sensor combine to provide a basic baghouse and cartridge filter leak detector designed for general maintenance planning and process protection. It is easy to use and reliable. Leakage is gaged in real-time, on-the-spot, without prior baseline data and without signal tuning. Simply apply power and the general condition of the filter is quickly determined. An alarm point is set by simply moving an indicator up and down the gage with the convenient, lockable key pad. For more precise alarm setup the large display provides both a logarithmic analog bar graph and an absolute digital readout. The log scale enables the user to observe both the baseline bleed through and the high peaks that are caused by filter cleaning cycles and developing leaks. Observation of both baseline and peaks is essential to setting proper alarms. The digital readout in absolute units ensures correct interpretation of the readings and provides accurate historical comparisons.
the dpm particulate monitor is housed in a rugged cast aluminum enclosure. An lcd displays particulate levels in bar-graph and digital forms. A lockable membrane keypad is provided for setup and adjustment.
product applications
baghouses
cartridge filters
bin vents
specifications
inputs:from pms sensor.
output ratings:alarm relays: 2 form a (spst) rated 5a @ 240v res. (must provide an 8a [maximum] fuse in series with relay load); analog: 4 to 20 ma (option rc).
power requirements:115 vac 50/60 hz, 230 vac 50/60 hz, or 24 vdc.
power consumption:6 watts max.
accuracy:standard: 5% of range; optional: 1% of range.
display:lcd.display resolution:standard: 5 pa; optional: 0.5 pa.
memory backup:for set point storage only.
temperature limits:-13 to 160f (-25 to 70c).
weight:4.5 lbs (2.0 kg).
enclosure:cast aluminum, weatherproof, nema 4x.
loop power supply (isolated):17 vdc loop supply provided by dpm control unit for pms sensor.
agency approvals:ce, csa.*
*dpm models listed intrinsically safe are to be used with corresponding intrinsically safe pms models making an intrinsically safe control loop. The pms model can then be installed in a hazardous location according to approval ratings listed. The dpm itself is not intrinsically safe and must be installed outside the hazardous location.
features
rugged cast aluminum housing with lockable membrane keypad
programmable alarm points
large lcd to display readouts digitally
options
-rc analog output (4-20 ma)
related products
series tfls tuning fork level switch
series tfls tuning fork level switch
series dct1000 dust collector timer controller
series dct1000 dust collector timer controller
series dct500a low cost timer controller
series dct500a low cost timer controller
series cls2 capacitive level switch
series cls2 capacitive level switch
series pls paddle level switch
series pls paddle level switch
series pms particulate sensor
series pms particulate sensor
series dct600 timer controller
series dct600 timer controller
Power : Or 24 VDC.
Color : Grey
Condition : New
Display Type : Digital, LCD-Standard: 5 PA; Optional: 0.5 PA.
Weight : 4.5 Lbs (2.0 Kg).
Operating Temperature : -13 To 160F (-25 To 70C).
Power Source : Or 24 VDC.
Application : Bin Vents
Warranty : 1 Yr
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T