Fitted with D.C. MOTOR but to work on 220 Volts AC with Variable Speed from 20R.P.M. to 120R.P.M. Approx. SECORE Jar Test Apparatus allows efficient and economical flocculation matter and collides in general and also has been specially designed for use in water treatment to corremore...
Specification Loading jack screw type capacity 10, 000kg (100KN) with U bracket Penetration piston assembly 50m dia. Set of 7 extension spacers of assorted length with connectors. Dial gauge support (Datum Bar) of welded steel, complete with adjustable bracket for diamore...
We are one of the leading Manufacturers and Suppliers of Aggregate Impact Testing Apparatus developed as per IS: 2386 (Part IV) fabricated. The Aggregate Impact Testing Apparatus, we design, is of the best quality and has been manufactured keeping in mind the different customer smore...
Bulk density test apparatus as per I.S. 2386 Part IV. Determines bulk density or unit weight of aggregates. Â Specifications: Calibrated cylindrical measures of sheet iron with handles. Consists of 3 measures one each 3 litres capacity, 15 litres capacity and 30 litres capacity.more...
Slump cone test apparatus conforming to specifications and tolerance in accordance to I.S. 1199 and latest I.S.7320. Consists of a slump cone frustum in shape 10cm dia at top, 20cm at bottom and 30cm hight fitted with foot piece and handle, one portable base plate having cleats tmore...
U box test Apparatus U Box test is used to measure the filing ability of self compacting concrete. The apparatus consists of a vessel that is divided by a middle wall into two compartments; an opening with a sliding gate is fitted between the two sections. Reinforcing bar with nomore...
This standard covers the procedure for determination of content of diffusible hydrogen in deposited weld metal arising from the use of Shielded Metal Arc Electrodes, Gas Metal Arc, Flux cored Arc , Submerged Arc and MIG wire Welding Process bmore...
This standard covers the procedure for determination of content of diffusible hydrogen in deposited weld metal arising from the use of Shielded Metal Arc Electrodes, Gas Metal Arc, Flux cored Arc , Submerged Arc and MIG wire Welding Process bmore...
MOISTURE TESTING APPARATUS : The moisture content of the covering on the Low Hydrogen electrodes shall be determined as per the procedure laid down in SFA-5.1. The apparatus consist of the following : Combustion Tube Furnace with heating element to 2000*F (1093*C.) An Oxygen purimore...