Our Product / Services
Our product range contains a wide range of Dry Air Desiccant System, Air Conduction System, Kit MC OEM, Sensible Heat Exchanger Rotor and Corrugation selection
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden Box
Delivery Time : 1-Month
Additional Information:
Payment Terms : L/C, T/T
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : wooden box
Delivery Time : 8-10 Week
Additional Information:
Payment Terms : L/C, T/T
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden Box
Delivery Time : 1-Month
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden Box
Delivery Time : 1-Month
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden Box
Delivery Time : 1-Month
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden Box
Delivery Time : 1-Week
most suppliers not providing this process because of the costing issue but this most imporatnt part of production.
this conveyer provding strength to corrugated sheet and remove the rest of moisture of corrugated sheet.
this process will increased the cooling pad durability and life outo 5-6years
We are providing three hundred litters capacity stainless steel fabricated motorised with gear box.
Suspended air handling units in heat- and sound-insulated casing with horizontal spigot orientation. Air capacity up to 220 m3/h, heat recovery efficiency up to 89 %.
The suspended air handling units VUT2, VUE2 and VUTE2 200 P are the fully-featured ventilation units that ensure air filtration, fresh air supply and stale air extract.
The model VUT2 ensures sensible heat recovery and the models VUE2 and VUTE2 ensure sensible heat and moisture recovery in two plate heat exchangers. The units are applied as components of ventilation and air conditioning networks for various premises. The units are featured with extremely low noise level due to the fans located between two heat exchangers.
High heat recovery efficiency of the units meets the strict energy saving market demands. Compatible with round 125 mm air ducts.
Modifications :
VENTS VUT2 200 Punit with two aluminium cross-flow heat exchangers.
VENTS VUE2 200 Punit with two cross-flow heat exchangers of polymerized cellulose.
VENTS VUTE2 200 Punit with two cross-flow heat exchangers (one made of polymerized cellulose and another made of aluminium).
Casing :
Made of aluzinc, internally filled with 10 mm cellular polypropylene heat- and sound-insulating layer.
Filter :
Supply and extract air flows are purified through two bag filters with filtering class G4.
Fans :
The unit is equipped with a supply and exhaust centrifugal fan with backward curved blades and integrated overheating protection thermostat with automatic restart. The motors and the impellers are dynamically balanced in two planes.
Heat exchangers :
The units incorporate two heat exchangers types:
The aluminium heat exchangersare designed to ensure sensible heat energy transfer from extract to supply air flow. The heat exchangers are distinguished by long service life in a cold climate.
The enthalpy polymerized cellulose heat exchangerare designed to recuperate sensible heat and latent energy contained in the extract air to warm up supply air flow. The heat exchangers are frostproof and produce no condensate. The units with such heat exchangers are recommended for use in air conditioned premises.
The unit VUT2 200 P is equipped with two aluminium cross-flow heat exchangers with drain pans and heat exchanger freezing protection.
The VUE2 200 P unit is equipped with two enthalpy polymerized cellulose counter-flow heat exchangers. The unit VUTE2 200 P is equipped with two cross-flow heat exchangers, one made of aluminium and another of polymerized cellulose. The unit has a drain pan to remove condensate from the aluminium heat exchanger.
The unit is equipped with a switch that enables selection of one of three unit operation modes: standby mode, low speed (LOW) and medium speed (MED).
The unit may be equipped with P3-1-300 switch that enables switching the unit on/off and setting one of three unit operation modes: low speed (LOW), medium speed (MED) and high speed (HIGH). The unit may be equipped with a CO2 sensor (not included into the delivery set). In case of high CO2 concentration it switches the unit to maximum (HIGH) speed.
The unit may be equipped with A13 LCD control panel (not included into the delivery set) for turning the unit on/off, switching to low, medium and high speed as well as room temperature displaying.
The integrated freezing protection system is designed to prevent the heat exchanger freezing at low temperatures. In case of freezing danger indication by the temperature sensor the supply fan is turned off to let warm extract air flow pass by the heat exchangers and warm them up. After freezing danger is no longer actual, the supply fan is turned on and the unit reverts to the standard operation mode.
Mounting :
The unit is designed for suspended ceiling mounting in balcony, storeroom, basement, attic and other auxiliary premises. The unit is also suitable for installation in major premises directly to the ceiling, behind the false ceiling or in the ceiling recess. Acess for servicing and cleaning through the bottom panel. The unit is suitable for wall mounting as well.
Desiccant Rotors are developed thru complete understanding with analytical study and development on multiple processes. Keeping in mind the application purposes all the research activities were performed.
Beyond performance is the word of today and innovation is understood as Initial action with Goal deliverance makes Devdry Desiccant rotors durable for your Utility.
DevDry - SG:
DevDry-MS:Desiccant rotor has large adsorption capacity of synthesized hydrophilic zeolite for ultra low dew point application as plastic drying. The Molecular sieve adds multiplying value reducing the Moisture and getting very-dry Air
DevDry-VOC Adsorbent:It is unique honeycomb medium containing a high performance adsorption agent suitable for various VOC(Volatile Organic Compound) discharged from photochemical oxidants & noxious odours.
Devdry Desiccant Rotor have the below Features.
Drying is a mass transfer process consisting of the removal of water or another solvent by evaporation from a solid, semi-solid or liquid. This process is often used as a final production step before selling or packaging products. To be considered "dried", the final product must be solid, in the form of a continuous sheet (e.g., paper), long pieces (e.g., wood), particles (e.g., cereal grains or corn flakes) or powder (e.g., sand, salt, washing powder, milk powder). A source of heat and an agent to remove the vapor produced by the process are often involved. In bioproducts like food, grains, and pharmaceuticals like vaccines, the solvent to be removed is almost invariably water.
In some products having a relatively high initial moisture content, an initial linear reduction of the average product moisture content as a function of time may be observed for a limited time, often known as a "constant drying rate period". Usually, in this period, it is surface moisture outside individual particles that is being removed. The drying rate during this period is mostly dependent on the rate of heat transfer to the material being dried. Therefore, the maximum achievable drying rate is considered to be heat-transfer limited. If drying is continued, the slope of the curve, the drying rate, becomes less steep (falling rate period) and eventually tends to nearly horizontal at very long times. The product moisture content is then constant at the "equilibrium moisture content", where it is, in practice, in equilibrium with the dehydrating medium. In the falling-rate period, water migration from the product interior to the surface is mostly by molecular diffusion, i, e. the water flux is proportional to the moisture content gradient.
DRYING EQUIPMENT :
Tray Dryers :In tray dryers, the food is spread out, generally quite thinly, on trays in which the drying takes place. Heating may be by an air current sweeping across the trays, by conduction from heated trays or heated shelves on which the trays lie, or by radiation from heated surfaces. Most tray dryers are heated by air, which also removes the moist vapours.
Tunnel Dryers :These may be regarded as developments of the tray dryer, in which the trays on trolleys move through a tunnel where the heat is applied and the vapours removed. In most cases, air is used in tunnel drying and the material can move through the dryer either parallel or counter current to the air flow. Sometimes the dryers are compartmented, and cross-flow may also be used.
Roller or Drum Dryers :In these the food is spread over the surface of a heated drum. The drum rotates, with the food being applied to the drum at one part of the cycle. The food remains on the drum surface for the greater part of the rotation, during which time the drying takes place, and is then scraped off. Drum drying may be regarded as conduction drying.
Fluidized Bed Dryers :In a fluidized bed dryer, the food material is maintained suspended against gravity in an upward-flowing air stream. There may also be a horizontal air flow helping to convey the food through the dryer. Heat is transferred from the air to the food material, mostly by convection.
Spray Dryers :In a spray dryer, liquid or fine solid material in a slurry is sprayed in the form of a fine droplet dispersion into a current of heated air. Air and solids may move in parallel or counterflow. Drying occurs very rapidly, so that this process is very useful for materials that are damaged by exposure to heat for any appreciable length of time. The dryer body is large so that the particles can settle, as they dry, without touching the walls on which they might otherwise stick. Commercial dryers can be very large of the order of 10 m diameter and 20 m high.
Pneumatic Dryers :In a pneumatic dryer, the solid food particles are conveyed rapidly in an air stream, the velocity and turbulence of the stream maintaining the particles in suspension. Heated air accomplishes the drying and often some form of classifying device is included in the equipment. In the classifier, the dried material is separated, the dry material passes out as product and the moist remainder is recirculated for further drying.
Rotary Dryers :The foodstuff is contained in a horizontal inclined cylinder through which it travels, being heated either by air flow through the cylinder, or by conduction of heat from the cylinder walls. In some cases, the cylinder rotates and in others the cylinder is stationary and a paddle or screw rotates within the cylinder conveying the material through.
Trough Dryers :The materials to be dried are contained in a trough-shaped conveyor belt, made from mesh, and air is blown through the bed of material. The movement of the conveyor continually turns over the material, exposing fresh surfaces to the hot air.
Bin Dryers :In bin dryers, the foodstuff is contained in a bin with a perforated bottom through which warm air is blown vertically upwards, passing through the material and so drying it.
Belt Dryers :The food is spread as a thin layer on a horizontal mesh or solid belt and air passes through or over the material. In most cases the belt is moving, though in some designs the belt is stationary and the material is transported by scrapers.
Vacuum Dryers :Batch vacuum dryers are substantially the same as tray dryers, except that they operate under a vacuum, and heat transfer is largely by conduction or by radiation. The trays are enclosed in a large cabinet, which is evacuated. The water vapour produced is generally condensed, so that the vacuum pumps have only to deal with non-condensible gases. Another type consists of an evacuated chamber containing a roller dryer.
Freeze Dryers :The material is held on shelves or belts in a chamber that is under high vacuum. In most cases, the food is frozen before being loaded into the dryer. Heat is transferred to the food by conduction or radiation and the vapour is removed by vacuum pump and then condensed. In one process, given the name accelerated freeze drying, heat transfer is by conduction; sheets of expanded metal are inserted between the foodstuffs and heated plates to improve heat transfer to the uneven surfaces, and moisture removal. The pieces of food are shaped so as to present the largest possible flat surface to the expanded metal and the plates to obtain good heat transfer. A refrigerated condenser may be used to condense the water vapour.
We are the prominent manufacturer, supplier and service provider of Electric Panels for our precious clients. We have specialized in production of high quality PLC Panels and all types of electric panels for industrial purpose. we offer wide ranges of panels & Our offered range is appreciated among clients due to their excellent performance, high durability and longer service life. Further, we offer automation & controls panels for process controls, conveyors panels for water & waste water, textile, paper, plastic, pharmaceutical, chemical & various other industries.
PLC Control Panels are used in process plants for plant automation purpose. We design, select and supply complete instrumentation required for such Instrumentation panels with instruments like indicators, controllers, recorders, annunciators and many process instruments. PLC Control Panels we manufacture are highly capable of giving higher output at less power consumption. Integrated with solid PLC logic and flawless PLC hardware programming.
Greenhouse Control Panel can aid the home gardener or professional horticulturists by automatically adjusting temperature, humidity, and light intensity from within the greenhouse or from a remote location. Greenhouse Control Panel will improve plant life within greenhouse by providing a constantly monitored atmosphere, producing a more uniform product.
Specific Application Areas
Air handling units with heat recovery in the compact sound- and heat-insulated casing. Air capacity up to 106 m3/h. Heat recovery efficiency from 64 up to 76%.
Compact air supply and exhaust ventilation unit VUE 100 P mini is a simple and effective energy-saving solution ventilation of apartments, cottages, single-family houses, workshops and trade premises.
The unit is a fully-featured ventilation unit that provides air cleaning, fresh air supply to the premise and removal of extract air from the premise. Extract air thermal energy is transferred to the cross-flow heat exchanger and is used to warm up the supply air flow. Built-in heat exchanger prevents heat losses and saves operating costs for heating in winter and air conditioning in summer.
Due to the compact casing and silent operation the VUE 100 P mini unit can be installed behind suspended ceiling. The unit is designed for connection to 125 mm round air ducts. Several rooms may be ventilated if they are connected with air distribution network. Air flow regulation with A3 (P3-1-300) speed switch.
Casing :
The casing is made of corrosion-resistant alumozink and sound-insulated with 15 mm ellular polyethylene layer. For easy mounting the casing is fitted with mounting brackets.
The detachable panel is swivel connected to the unit to provide fast and easy access to the casing internal components for servicing and maintenance. The unit is equipped with two backdraft dampers, one in the supply and the other in the exhaust air duct.
Filter :
Supply and extract air flows are purified through two filters with filtering class G4. The filters prevent dirt and dust ingress into the room and protect the unit components against contaminations.
Fans :
The unit is equipped with reliable supply and exhaust fans with forward curved blades that are powered by motors with low energy demand. The motor has maintenance-free ball bearings that ensure long service life about 40 000 hrs and are greased for the operation period.
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Cardboard
Delivery Time : 1-Week