Leading Manufacturer, Supplier & Retailer of 11 KV Three Phase Isolation Transformer, 15 KVA Three Phase Isolation Transformer, 20 KVA Three Phase Isolation Transformer and 25 KVA Three Phase Isolation Transformer.

11 KV Three Phase Isolation Transformer

2 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Power 315
  • Cooling Type Oil Cooled
  • Phase Three Phase
  • Primary Connection Type Delta
  • Secondary Connection Type Star or Wye
  • Secondary Voltage 0.433 KV
  • Primary Voltage 11 KV
  • Reference Standard IEC/BS/ANSI/IS/NEEMA
  • Copper Electrolyte grade, 99.9% pure
  • Core The core is constructed from low loss, cold – rolled, grain oriented, annealed lamination.
  • Standard Fitting As per IS 2026/IEC76
  • Vector Group DYN 11
  • Duty Cycle Continuous
  • Cooling ONAN
  • Frequency 50 Hz

Tapping

  • Off circuit tap changer to provide +5 to -10% taps in step of 2.5%
  • On Load tap changer to provide +7 to -20% taps in step of 1.75%

Additional Information:

Delivery Time : 15 Days

View Complete Details

15 KVA Three Phase Isolation Transformer

15,000 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Power 15 kVA
  • Brand Name DESTA
  • Cooling Type Air Cooled
  • Voltage 415 Volts
  • Phase Three Phase
  • Frequency 50 Hz
  • Input Voltage 415 Volts
  • Output Voltage 210 Volts
  • Production Capacity 100 Pcs. / Month

Additional Information:

Delivery Time : 5 to 10 Days

Technical Specification

Parameter Single Phase Unit Three Phase Unit
Input Voltage Range 230V / 240V 400V / 415V
Nominal Output Voltage 230V / 240V 400V / 415V
System Construction Delta / Star
Ratio 01:01:00 AM
Vector Group DYN 1:1
Common mode noise rejection 25 db
Transient, Spikes, Surges, Coupling Capacitance .012PF
DG Galvanic Isolation 1000M-Ohm
Break Down Strength 2500VAC for 2 minutes
Frequency 50±3%
Load Regulation 3-5%
Cooling ONAN or Air
Class Insulation F
Lamination CRGO
Copper Electrolytic grade 99.9% PURE
Sanders IS : 2026
View Complete Details

20 KVA Three Phase Isolation Transformer

50,000 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Power 20 KVA
  • Cooling Type Air Cooled
  • Mounting Type Indoor Floor Mount
  • Phase Three Phase
  • Frequency 50 Hz
  • Secondary Voltage 415 Volts
  • Primary Voltage 415 Volts
  • Production Capacity 50 Pcs. / Month
  • Input Voltage 415 Volts
  • Output Voltage 415 Volts

Additional Information:

Delivery Time : 5 to 10 Days

Technical Specification

Parameter Single Phase Unit Three Phase Unit
Input Voltage Range 230V / 240V 400V / 415V
Nominal Output Voltage 230V / 240V 400V / 415V
System Construction Delta / Star
Ratio 01:01:00 AM
Vector Group DYN 1:1
Common mode noise rejection 25 db
Transient, Spikes, Surges, Coupling Capacitance .012PF
DG Galvanic Isolation 1000M-Ohm
Break Down Strength 2500VAC for 2 minutes
Frequency 50±3%
Load Regulation 3-5%
Cooling ONAN or Air
Class Insulation F
Lamination CRGO
Copper Electrolytic grade 99.9% PURE
Sanders IS : 2026
View Complete Details

25 KVA Three Phase Isolation Transformer

30,000 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Phase 3 Phase
  • Brand Name DESTA
  • Cooling Type Air
  • Mounting Type Indoor Floor Mounting
  • Frequency 50 Hz
  • Production Capacity 60 Pcs./ Month
  • Input Voltage 400 Volts
  • Output Voltage 415 Volts

The modern machines and system need a truly isolated clean power in which any electrical disturbance in the primary side is effectively not passed on to secondary side. Therefore an Isolation / Ultra Isolation transformer ensures total electrical and electro static isolation with most effective screening of spikes, surge and transients. Further, it gives a true isolated local neutral and dedicated earth which is essential for modern machines. It provides noise or interference free power and prevents transfer, RF and HF disturbances with extensive isolation between primary and secondary. The isolation level with stand HV break down strength of 2.5KV and give DC galvanic isolation of more than 1000M Ohms.
There is common problem at same sites that power neutral is missing / weak or not available. At this site A/C does not start as voltage does not develop between phase and weak or missing neutral. These Three phases Isolation transformer are designed to get rid of these problems. In the Isolation transformer a new neutral is generated, which is healthy, perfect and has no connection with the neutral of electricity supply and hence unbalancing does not occur resulting in the A/C compressor and machine working perfectly fine.

Additional Information:

Delivery Time : 10 Days

Technical Specification

Parameter Three Phase Unit
Input Voltage Range 400V
Nominal Output Voltage 400V
System Construction Delta / Star
Ratio 01:01:00 AM
Vector Group DYN 1:1
Common mode noise rejection 25 db
Transient, Spikes, Surges, Coupling Capacitance .012PF
DG Galvanic Isolation 1000M-Ohm
Break Down Strength 2500VAC for 2 minutes
Frequency 50±3%
Load Regulation 3-5%
Cooling ONAN or Air
Class Insulation F
Lamination CRGO
Copper Electrolytic grade 99.9% PURE
Sanders IS : 2026
View Complete Details