Our Products
Valves & Valve Fittings
2 Products availableLaboratory Equipments
2 Products availablePVC, PP & Plastic Products
2 Products availableWe offer a complete product range of Digital Gas Flow Meter, Nitrogen Gas Generator and Liquid Flow Meters
Specification | Mass Meter | Description |
Accuracy | ± (0.8% of Reading + 0.2% of Full Scale) |
At calibration conditions after tare |
High Accuracy Option | ± (0.4% of Reading + 0.2% of Full Scale) | At calibration conditions after tare |
Accuracy: Bi-directional Meters Only |
± (0.8% of reading + 0.2% of total span positive full scale to negative full scale) |
At calibration conditions after tare |
Repeatability | ± 0.2% | Full Scale |
Operating Range | 1/2% to 100% | Full Scale |
Turndown Ratio | 200: 1 | |
Typical Response Time | 10 | Milliseconds (Adjustable) |
Standard Conditions (STP) | 25°C & 14.696P5IA | Mass Reference Conditions |
Operating Temperature | -10 to +50 | °Celsius |
Zero Shift | 0.0002 | Full Scale / °Celsius /Atm |
Span Shift | 0.0002 | Full Scale / °Celsius /Atm |
Humidity Range | 0 to 100% | Non-Condensing |
Measurable Flow Rate | 1.28 | Full Scale |
Maximum Pressure | 145 | PSIG |
Output Signal Digital | Mass, Volume, Pressure & Temperature |
RS-232 Serial or RS-485 Serial or PROFIBUS or DeviceNet I |
Output Signal Analog | Mass Flow | 0-5Vdc |
Optional Output Signal Secondary Analog |
Mass, Volumetric Pressure or Temperature |
0-5 Vdc or 0-10Vdc or 4-20mA |
Electrical Connections | 8 Pin Mini-DIN, DB9 or DB15 | |
Supply Voltage | 7 to 30 Vdc (15-30Vdc for 4-20mA outputs) | |
Supply Current | 0.040 Amp (+ output current on 4-20mA) | |
Mounting Attitude Sensitivity | 0 | Tare after installation |
Warm-up Time | <1 | Second |
Wetted Materials- |
303 & 302 Stainless Steel, Viton®, Silicone RTV (Rubber), Glass Reinforced Nylon,Aluminum. |
Principle Specifications |
LC-MS |
LC-MS-MS (for sciex model) |
Turbo Evaporator |
Moisture |
5 ppm |
5 ppm |
|
Total Hydro Carbon |
< 1 ppm |
< 1 ppm |
|
Co & Co2 |
< 2 ppm |
< 2 ppm |
|
Purity |
99.9% |
99.99% |
|
Micro Particulates |
< 1.10µ |
< 1.10µ |
< 1.10µ |
Capacity of N2 |
6 to 30 LPM at 100 psig |
12 LPM at 100 psig |
50 to 700 LPM |
Generator |
(as per selection of model) |
8 LPM at 60 psig (purified dry air) |
At 60 psig (as per selection of model) |
Method of purification |
Pressure Swing Adsortion (PSA) |
Pressure Swing Adsortion (PSA) |
Pressure Swing Adsortion (PSA) |
Room temperature |
5°C to 25°C |
5°C to 25°C |
5°C to 25°C |
Start Up time |
1 hrs/ programmable timer |
1 hrs/ programmable timer |
1 hrs |
Electrical requirements without compressors |
230 V AC , 50 Hz, 1ph, 2 Amps |
230 V AC , 50 Hz, 1ph, 2 Amps |
230 V AC , 50 Hz, 1ph, 2 Amps |
Dimensions of N2 Generators in mtr. (without compressor) |
1.5 H x 0.8W x 0.8 D (approx) |
2 H x 1W x 1 D (approx) |
2 H x 1W x 1 D |