Our Products
Inverters
2 Products availableHeaters, Thermostats & Heating Devices
2 Products availableRoom Heater
1 Products availableIndustrial Blowers, Coolers & Fans
1 Products availableDATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip incU.S.A. The Digital Technology used in the product offers HighReliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.
SAFETY INSTRUCTIONS
SALIENT FEATURES
DATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip inc U.S.A. The Digital Technology used in the product offers High Reliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.
SAFETY INSTRUCTIONS
OPERATING MODES OF THE INVERTER
Mains/charging of the mode
The inverter function on Mains Mode when the input AC mains is within the stipulated range from 90V AC to 280 V AC. The charger section starts functioning and continues to boost charge the batteries till the top-up voltage is reached . Thereafter the batteries are pulse charged to maintain optimum battery condition for an extended period of time.The connected loads are fed from input Mains Power. LED status indicator is GREEN. In the LCD models, mains Mode , Charging Mode, Mains input voltage, Battery level percentage etc are sequentially displayed on (16×2) backlit LCD.
Inverter / Backup mode
In the event of brownouts (<90V AC) on High Voltage (>280V AC) or Total Mains Failure(blackouts), the Inverter switches to loads derived from the Batteries. The Inverter keeps on supplying power till the time the battery gets depleted, in which case the inverter put out an alarm and thereafter shuts off. During invertor Mode, if for any reason the inverter gets overloaded , it trips and then restart after a while. The inverter makes a total of 5 restart attempts. Front panel LED status indicator is RED. In the LCD models, Inverter mode, Battery level percentage, Load level percentage, Input voltage level etc are sequentially displayed on (16×2) backlit LCD.
REAR PANEL DESCRIPTION
Technical Specification
Input Voltage Range : | 90-280 V AC |
Low voltage Cut-Off : | 90 V AC+ 10 V |
High Voltage Cut-Off : | 280 V AC + 10 V |
Output Voltage (on Mains) : | Same as input |
Output Voltage (on Batt) : | 195-245 V AC |
Transfer Time : | Within 20 ms |
Frequency (on Batt) : | 50 HZ + 1% |
Charging Current : | 10% of Battery Content |
Pulse Charging Mode : | Auto Top-up Pulse Mode |
Mains Mode Overload : | Circuit Breaker Trip |
Inverter Mode Overload : | Electronic Shut Down |
Auto Restart Feature : | Yes |
Inverter short circuit : | Electronic Shut Down |
SALIENT FEATURES
DATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip inc U.S.A. The Digital Technology used in the product offers High Reliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.
SAFETY INSTRUCTIONS
OPERATING MODES OF THE INVERTER
Mains/charging of the mode
The inverter function on Mains Mode when the input AC mains is within the stipulated range from 90V AC to 280 V AC. The charger section starts functioning and continues to boost charge the batteries till the top-up voltage is reached . Thereafter the batteries are pulse charged to maintain optimum battery condition for an extended period of time.The connected loads are fed from input Mains Power. LED status indicator is GREEN. In the LCD models, mains Mode , Charging Mode, Mains input voltage, Battery level percentage etc are sequentially displayed on (16×2) backlit LCD.
Inverter / Backup mode
In the event of brownouts (<90V AC) on High Voltage (>280V AC) or Total Mains Failure(blackouts), the Inverter switches to loads derived from the Batteries. The Inverter keeps on supplying power till the time the battery gets depleted, in which case the inverter put out an alarm and thereafter shuts off. During invertor Mode, if for any reason the inverter gets overloaded , it trips and then restart after a while. The inverter makes a total of 5 restart attempts. Front panel LED status indicator is RED. In the LCD models, Inverter mode, Battery level percentage, Load level percentage, Input voltage level etc are sequentially displayed on (16×2) backlit LCD.
REAR PANEL DESCRIPTION
Technical Specification
Input Voltage Range : | 90-280 V AC |
Low voltage Cut-Off : | 90 V AC+ 10 V |
High Voltage Cut-Off : | 280 V AC + 10 V |
Output Voltage (on Mains) : | Same as input |
Output Voltage (on Batt) : | 195-245 V AC |
Transfer Time : | Within 20 ms |
Frequency (on Batt) : | 50 HZ + 1% |
Charging Current : | 10% of Battery Content |
Pulse Charging Mode : | Auto Top-up Pulse Mode |
Mains Mode Overload : | Circuit Breaker Trip |
Inverter Mode Overload : | Electronic Shut Down |
Auto Restart Feature : | Yes |
Inverter short circuit : | Electronic Shut Down |
Uninterrupted PowerAutomatic emergency backup power available in the event of power failure.
Voltage RegulationProvide regulated output for wide range of input voltage variations.
Surge ProtectionFull time protection against AC line surge, Spike, Noise and interference.
Modem ProtectionProvides protection against lightning strike entering the system through modem lines.
ProtectsYour precious software, PC and peripherals.
Model | U.P.S. 600 | U.P.S. 700 | U.P.S. 1250 | U.P.S. 2000 |
Capacity | 600 VA | 700 VA | 1250 VA | 2 KVA |
Input | |
Input Voltage Range | 145V – 265 V AC |
Frequency Range | 50 HZ + 5% |
Phase | Single Phase |
Regulation of Mains | Automatic Voltage Regulation |
Output | |
Output Voltage | 220 V AC + 10% |
Regulation Voltage on Battery | Pulse Width Modulation |
Transfer Time | 3 – 7 ms (typical) |
Waveform | Stepped approximation of Sine wave |
Efficiency | > 83% |
Power Factor | 0.7 lag to unity |
Protection | |
Surge | E . M . I. , R . F. I., Spike and Surge Protection Provided |
Input Fuse | Fuse Protection Provided |
Short Circuit Protection | Pulse to Pulse Electronic Shutdown Provided |
Modem / Network | RJ – 11 or RJ – 45 Jack optional |
Noise Level | |
Audible Noise | < 40 dBA or one meter |
RFI Noise | < 10dB at 0.15 MHZ, < 50 dB at 50 MHZ |
Crest Ratio | |
Crest Ratio at Output | 3:1 |
Annunciations & Alarms | |
Charging / Mains Mode | Green LED On |
Battery Low / Overload | Red LED With buzzer |
Battery | |
Built in Models | Sealed Lead Acid Maintenance Free Batteries built- in |
Charger | Fully Optimized CC – CV Charger |
Protection | Overcharge , Deep Discharge Protection Provided |
Extended Backup Models | Sealed or Stationary Lead Acid or Tubular Plate Batteries upto 100 Ah Connected externally |
Physical | ||||
Dimensions H X W X D (inches) | 6.5 X 4 X 12 | 7 X 4.5 X 13 | 8 X 6 X 14 | 8 X 6 X 14 |
Weight (Kgs) | 6.5 | 10.5 | 16.0 | 18.0 |
Ambient Conditions
Temperature 0oC ~ 48o C; 32oF ~ 120o F
Humidity <95% R . H. (non condensing)
Ideal for embroidery, knitting, quilting, sortex, flex & digital printing, medical, server, networking & computer application. |
Ideal for home, shops, party , picnic and camping etc.
Material : High quality ABS plastic bodyHolder: CFL or Bulb holderStrong LED torchUSB Port : Pen drive for music & Mobile Charging through USBDigital FM RadioSMPS Charger of 8 Amp (switch mode power supply)12V 7.2Ah maintenance free dry batteryBattery Charging- 100 Volt To 280 Volt3 Inch High Quality SpeakerLoad: Upto 45 wattsCharging Cut: 14.2 VoltOverload: 60WLow Battery Cut: 9.5 VoltDigital controller base designHigh frequency PWM (pulse-width modulation)Indication: Overload, Charging On , Mains On, UPS On, Low battery, Over load.Supports 4 10W CFL (Not included), Only one CFL is connected, rest three needs to be connected with wires/holdersPlugs : 3 x 2 pin plugsSolar panel input port, you can directly connect external solar panel (not included)Fuse : over load protection fuse (10 Amp)Digital panel buttonsYou can run DC voltage operated mini fanFull function Remote Control2 Pin power cord : 1.5 MeterMinimum 5 hours continues charging required
Note : Specifications are subject to change without notice.
Ideal for medical, printing, server, networking & computerapplication, weighing scales & weigh bridge panels. |
Model -DV 15/25 Ltr.(Gold)STAINLESSSTEEL TANK
Top & Bottom-ABS
Inbuilt Temperature Meter
Glass Insulation
Magnesium Anode
SS Tank
SALIENT FEATURES
Model DV15/25 (PLATINUM)
Full ABS Body
Capillary Thermostat
Magnesium Anode
SS Tank
Model DV15/25 (CRYSTAL) (S.S. Tank/Glass Line Tank)
Full ABS Body
Glass Insulation
Capillary Thermostat
Pressure Release Valve
Magnesium Anode
Glass Line Tank