My ExportersIndia

For Buyer

For Seller

For Help

Our Products

TOP MOUNTED FLOAT OPERATED LEVEL TRANSMITTER

  • Suitable Down to 0.7 (Upto 0.5 optional) 0-150 mm upto 0-3000 mm.
  • Betterthan ±10 mm. Max. 25% of Span
  • Max. 25% of Span 12 - 36 V DC
PRINCIPLE OF OPERATION :

Level transmitter works on the principle of reed resistance/permanent magnet basis. Reedswitches function like the center arm (as shown in fig. 1) of a potentiometer. As per liquid level float moves up or down, magnet inside the float operates the reedswitches thereby causing a change in resistance value. Change in the resistance is measured by the electronics unit and conditioned as a current output of 4 to 20 mA. Signal conditioner is head mounted and of 2-wire loop powered suitable for 12 to 24 VDC giving output of 4 to 20 mA.

TECHNICAL SPECIFICATION : OUR STANDARD PRODUCT

Model (VMT-04-F65-AW) , (VMT-04-F92-AW)top mounted magnetic reed/resistance cascade type loop powered 2 wire level transmitter. Process Connection flange 78 or 120 mm diameter with 4 bolt holes of 6mm or 14 mm dia on 65 or 92 mm PCD respectively. Wetted parts flange & float stopper in SS 304. Float material SS 316L and diameter 41, 53 or 68 mm. Operating pressure 10kg/sq.cm and Temperature 125 deg.C. maximum.

SALIENT FEATURES :
    • Reedswitches are hermetically sealed-in glass under an inert gas and therefore protected from contamination.
    • Reedswitches used by us are suitable for maximum working voltage of 150 VDC and current 1 Ampere. But in our circuitry they are subjected to maximum of 3 VDC and current 1 mA in case of resistance output and maximum of 24 VDC and 20 mA when used in conjunction with a signal conditioner for current output. This ensures long life of the product.
    • Reedswitches are UL approved and ISO certified for quality management.
    • Operating temperature range of reedswitches are -40 deg. C. to 125 deg. C.
    • Reed Switches are enclosed in a moulded glass filled nylon capsule and therefore protected from mechanical shocks or damage. Moreover the stainless steel float-guide pipe, containing the PCB of reedswitches and resistances, is solidly filled with MgO Powder. Hence this is suitable for sub zero temperatures.
    • Reedswitches are protected against mechanical damage and contact corrosion & vibration.
    • Since an outer protection tube is provided (for applications like LPG, where external cage is not possible) the reedswitch sensor assembly can be replaced without disturbing the process.
    • Since the float is of 200mm dia with specific gravity -0.4 (for LPG) it will have higher buoyant force. For standard applications float shall be of 48 mm Or 68 mm in diameter.
    • Above all float is the only moving part. No wear and tear.
    APPLICATION :
        • Applicable in environment with high temp., high pressure, strong acid, strong alkaline and hazardous locations.
        • Multiple applications for textile dyeing, sewage water processing, power generating, boiler and petrochemical industries.
    View Complete Details

    Tubular Level Gauges

    Utilising the basic principle of - liquids find their level - tubular level gauges have been the most preferred and economical means of direct liquid level indication since time immemorial. Various means of glass tube protections- 3 plate glass protection, 3 guard rods, pipe guard or C-channel protections are in popular use. Our level gauges have C-channel protection of 2 mm thick sheet metal, making it robust and sturdy.

    A black powder coated aluminium engraved scale with white numerals & markings is provided for indication of the level of liquid in millimeter or Litres as required. Scale shall have minimum graduation of 5 mm.

    Process connections can be threaded or flanged to customer specifications. Isolating cock valves/needle valves or isolating needle valves with safety ball-check protection to prevent spilling/leakage by automatic shut-off in the event of glass tube breakage- are optional features

    OPTIONAL ACCEESSORIES :
    • Vent Cock Valve/Drain Cock/Vent & Drain Needle/Ball Valves
    • Gauge Isolating Needle Valves.
    • Gauge isolator valve: SS 304/316 solid barstock needle valve, offset type with safety ball-check protection and process connection as above (please specify).

    TECHNICAL SPECIFICATION
    PROCESS CONNECTION Threaded or Flanged
    CONNECTION SIZE 1/2" or 3/4" BSP(M) or Flanged to 3/4" or 1" ASA 150 Lbs as standard (Please specify other connections ,if required)
    END CONNECTION MOC (WETTED PARTS) Mild Steel Grey powder coated / Chromium plated MS / SS 304 / SS316 / PVC/ FRP
    GAUGE GLASS 19 mm H/W borosilicate glass tube.
    GLASS TUBE PROTECTION C-Channel of Grey powder coated or Chromium plated MS / SS304 / FRP Or SS316. (Size: 45x65x2mm)
    FLANGE GASKETS CAF-Acid alkali style 60
    SCALE Black powder coated aluminium with white numerals & markings.
    VENT& DRAIN PLUGS 1/2"BSP(M)
    BOLTS & NUTS HT bolts & nuts/SS 304
    MAXIMUM WORKING PRESSURE-10 KG/SQ.CM (DEPENDS ON LENGTH)
    MAXIMUM WORKING TEMPERATURE-100 DEG C (MAXIMUM LENGTH IN SINGLE PIECE-2500 MM
    View Complete Details

    Capacitance Type Level Transmitter

    A capacitance is formed between the probe and the vessel wall .As the level of the measuring medium rises or falls capacitance between the probe and vessel wall changes proportionately. A high frequency sine wave is applied between the probe and tank wall. A change of medium level will induce a change in the current of the applied sine wave. From when the capacitance in the vessel increase, impedance will decrease and current will increase and vice-versa. (Z=Resistance, C=Capacitance, F= Frequency)

    Head mounted electronics converts the capacitance variation to 4-20mA signal for long distance transmission. It is provided with trimpots for SPAN and ZERO adjustments. With no moving parts it is free from wear and tear, rugged and robust in construction. No dead zone like float based instruments.

    It must be ensured that the probe is parallel to the tank wall throughout it's length.

    TECHNICAL SPECIFICATION

    Capacitance type 3 wire Level transmitter Model (CLT-1) with non insulated probes for non-conductive liquids or PTFE Teflon insulated probes for conductive liquids.

    SALIENT FEATURES :
    1. Two parts isolated design-Electronic Module can be easily separated without removing the probe and without necessity of process shut down. So module replacement is easy.
    2. No moving parts, it is rugged and robust instrument.
    3. No dead band or dead zone like float based/ultrasonic instruments
    4. Suitable for operation from 12 to 32 VDC, with reverse polarity protection.
    5. Standard output 4-20mA.Voltage output of 0-10 optional. (For 12 V input supply output 0-5V and with 24 V supply output 0-10V)
    6. Plug and play with reference probe and rod.
    7. Remote electronics as option with 2 Metre long coaxial cable.
    8. Standard enclosure weather proof-cast Aluminium or Nylon 66. Flame proof as optional.
    9. Trim-Pots for span and zero adjustment.
    10. Kitchen & Hospital Equipments, etc.

     
    FREQUECY OF OPERATION 5 to15kHz.
    PROBE MATERIAL Stainless Steel / Teflon insulated 10/12/16 mm rod upto Max 3 Metre length
    PROCESS CONNECTION 3/4",1",1.1/2" BSP(M) or 1 "ASA 150 lbs flanged but thickness 12mm (or as per customer specification)
    POWER SUPPLY 24VDC
    OUTPUT 4 to 20 mA.(non-isolated)
    SPAN & ZERO ADJUSTMENT Trim pots
    MAX.WORKING PRESSURE 10kg/sq.cm
    MAX.WORKING TEMP. 150deg.C
    ACCURACY ±0.5%, ±1% or ±2%
    ENCLOSURE Cast aluminium weather proof with PG9 cable gland or Flame proof (IS2148-2004,Gr II A and B gases)
    CABLE SIZE 3 core, 0.75 sq.mm screened PVC cable.
    View Complete Details

    Ultra Sonic Level Transmitter

    SALIENT FEATURES :
    • SensComp, Inc. sensor module from U.S.A
    • Over Voltage Protection
    • Reverse Polarity Protection.
    • Direct or Reverse Action Adjustable at site.
    • Output : 0-5 Volts, 0-10 Volts - 3 Wire System.
    • Optional : 4 to 20 mA Output ( as a separate unit).
    • Teach-in Push Button Facility for Minimum & Maximum Value Settings.
    • Stainless Steel AISI 304 Housing Suitable for Outdoor Application.
    • Narrow Beam (15 deg) Angle.
    • 50 Khz Electronic Transducer with Integrated SMT Electronic Circuitry.
    • Range from 1-inch to 12-inch, 6-inch to 20 feet or 12 inch to 40-feet.
    • Power Requirements : 8 to 24 VDC for 5V Output / 12 to 24 VDC for 10 V Output (Maximum Current = 30 mA)
    • Operating Temperature -4 to +85 C (-40 to 185 F)
    View Complete Details

    Cable Suspended Float Switch

    • micro switch 1 Lac Operations
    • 250 VAC 10 Amp at 230 VAC Res
    • 15 Amp at 230 VAC 2 Bar
    • 70 degrees C. 5 Mtrs (Max. 20 Mtrs)
    • Polypropylene (PP) PVC

    Cable float switch is a control device for filling and discharging pumps, motor and magnetic valves. It is also an alarm device at certain pre-determined surface levels. It is suitable for use in non-flammable liquids at 250 volts. In dangerous enviroments (e.g. wells and pumping stations) we recommend 24 V voltage. In potentially explosive atmospheres (e.g. oil tanks) the Switch can be used in conjunction with (Ex) i-isolator switch units. Due to its large float casing the float

    Switch has a buoyancy which guarantees smooth, trouble-free operation under all conditions. The switch has double chamber and a final remoulding finish to make it absolutely hermetic.

    INSTALLATION :

    Cable Float Switch is simply placed in the liquid so that the float follows the movement of the surface. The switching height differential is adjusted by moving the weight along the cable. The differential is minimum, when weight is nearest to the float. If the viscosity of the liquid is high, we recommend an extra weight on the cable.

    View Complete Details

    Two Wire Head Mount Transmitters

    Since the signals generated by thermocouples or resistance sensors are low on emf and resistance, they can be transmitted over a short distance using compensating and three wire cables, without the loss of signal strength and accuracy. However, to transmit signals over very long distance without loss of accuracy, Two Wire loop transmitters are widely used. The low level signal converted to 4-20mA current output can be transmitted over long distance using a pair of normal copperwire. Accuracy of output current shall be independent of the lead resistance and length of the cable. The transmitter, fits directly into standard terminal head both weather proof or Ex-proof.

    APPLICATION :

    For converting thermocouple or Pt-100 or resistance signal to equivalent 4-20mA signal for long distance transmission.

    TECHNICAL SPECIFICATION
    INPUT Thermocouple, mV, Pt-100 or resistance signal from displacement, position or level sensor.
    OUTPUT (4-20)mA, two wire and loop powered (calibrated linearly to the input signal)
    CALIBRATION On site using ZERO / SPAN presents
    LOOP SUPPLY 12 to 36 VDC
    LOOP RESISTANCE 600 Ohms @ 24 VDC (Loop supply dependent)
    LOOP CONTINUITY Using built-in red LED Indication
    MOUNTING Standard weather proof or Flame proof head.
    OPERATING / STORAGE TEMPERATURE 0-70 degree C. Max. /0-50 Degree C. Max. @ 10-85 % Rh (Non-Condensing)
    SIZE 44 dia x 26 ht. 
    View Complete Details

    Electronic Control Units

    Electronic control unit in conjunction with level switches can be used for pump control, opening and closing of electrically operated valves, heaters and or high and low level indication.

    The electronic unit Model LC1 FL reduces the voltage and converts it to 5 VDC for operation of reedswitches enhancing their life, above all ensuring operational safety. The LED's in the front panel indicates Main Power Supply On, Pump Start and Stop conditions. The start/stop push buttons in the front panel enables testing of the control unit and also manual start and stop. The control unit has a Change over potential free relay output contact-hold on type. Contact change over takes place between High and Low level only. Relay contacts are rated 5 Amps at 230 VAC. Control action can be reversed at site by changing connections from NC to NO.

    For certain applications where high and low level indications are required, 2 separate relay output contacts are provided in the control unit-with LED indications for High, Low and Mains on

    Model LC2FL are used in boilers where High and Low Level Contacts are used for Pump start & stop while Very Low Level Contact is used for heater cut off.

    View Complete Details
    Tell Us What are you looking for? Will call you back

    Contact Us