Our Products
We offer the best product range of Auxiliary Relays, Digital Protection Relay, Electrical Control Relay, current relay and Over Voltage Relay.
Csepro series offers a multi functional comprehensive smart protection solution for feeder, generator, motor & transformer segment.csepro family of protective relays are advance numerical relays that provide multi protection and monitoring with reliable and fast protection solutions in a single unit.in this family of csepro series, the cseprotxxx is an advanced transformer protection solution which has fast, sensitive and secure protection fortransformer internal & external faults.cseprotxxx also provides an automation solution of power control. It complies with lec60870-5-103, lec6185o, modbus protocolfor high integration of protection & control.
Application :
cseprot differential relays are used as the main protection and control units for two winding power transformers, for both internal faults and faults in the influence area of current transformers.csepro-t units require no interposing transformers to adjust ct ratio and vector group correction as these adjustments are made by the relay itself in software. For these transformer winding configuration (vector group yd1, - dd10) & ct ratio are selectable though l-lml / usb communication. One has to select correct transformer winding configuration and ct ratio used in the protection scheme.Csepro-t modelcsepro-t is available in following models: cseprot140: for2-winding transformer protection (see table 23, 24)csepro-t170.
Benefits
In the family of protection relay, CSDPR-V2-400 is numeric multi-powered Over-current relay specially designed for ringmain units & feeder protection. It combines the following functions in one unit:
DESIGN :
In the family of protection relay, CSPR is numeric multi powered Overcurrent relay specially designed for ring main units &feeder protection. It combines the tollowingfunctions in one unit:CSPR is a high tech and cost optimized protection relay for MV switchboards. Specifically in compact switchboards, the CSPRcan replace the combination of load break switch.
Design :Relay will get energized from any ofthe following available sources
CSE offers a wide range of CT powered relayswhich provide over current, short circuit, instantaneous phase and earth fault functions.CSPR-V11 is a compact relay specificallydesigned for compact MV switchboards with circuitbreakers. CSPR-V1 uses CTs with secondary ratedfor 1A.
Product Description :
The CSPR-V1 is a CT-powered protection relaywith inverse time and definite time protectioncharacteristics.CSPR-V1 provides following protection functions:
CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 450 is an advanced feeder protection solution which has fast, sensitive andsecure protection for feeder internal & external faults.CSENEX-l offers different model based features to cover the wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.
Benefits
CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive andsecure protection forfeeder internal & external faults.CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.
Benefits
CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive andsecure protection forfeeder internal & external faults.CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.
Benefits
The application of powerful microprocessors with MRand IR-relays of the HIGH TECH RANGE provides alarge variety of advantages over power protectionsystems of the traditional type.The MR-protection relays are based exclusively on themicroprocessor technology. They represent our mostefficient generation of power protection systems.Because of their capabilities to process measuredvalues digitally and to perform arithmetical and logicaloperations, they are superior to the traditional analogsystems.Besides, the digital protection relays offer importantadditional advantages such as very low powerconsumption, adaptability, flexible construction, selection of relay characteristics etc.The IR-protection relays are based on themicroprocessor technology or on the analogtechnology. They represent a more cost savinggeneration of relays of the HIGH TECH RANGE, usedfor basic equipment protection.The IR-protection relays are superior to conventionalprotective devices because of their followingcharacteristics:
MR-protection relays are used for more complexprotective functions, such as earth fault directionaldetection, and also in cases where easy operation, quick fault-analysis and optimal communicationcapabilities are required.All relays of the HIGH TECH RANGE are availablefor flush mounted installation, as well as for rackmounting. Plug-in technology is used. Of course, allrelays comply with the IEC/DIN regulations requiredfor the specific protection application.
Benefits
The application of powerful microprocessors with MRand IR-relays of the HIGH TECH RANGE provides alarge variety of advantages over power protectionsystems of the traditional type.The MR-protection relays are based exclusively on themicroprocessor technology. They represent our mostefficient generation of power protection systems.Because of their capabilities to process measuredvalues digitally and to perform arithmetical and logicaloperations, they are superior to the traditional analogsystems.Besides, the digital protection relays offer importantadditional advantages such as very low powerconsumption, adaptability, flexible construction, selection of relay characteristics etc.The IR-protection relays are based on themicroprocessor technology or on the analogtechnology. They represent a more cost savinggeneration of relays of the HIGH TECH RANGE, usedfor basic equipment protection.The IR-protection relays are superior to conventionalprotective devices because of their followingcharacteristics:
MR-protection relays are used for more complexprotective functions, such as earth fault directionaldetection, and also in cases where easy operation, quick fault-analysis and optimal communicationcapabilities are required.All relays of the HIGH TECH RANGE are availablefor flush mounted installation, as well as for rackmounting. Plug-in technology is used. Of course, allrelays comply with the IEC/DIN regulations requiredfor the specific protection application.
Benefits
CSENEX-U Series relays provide reliable and high performance protection. TheCSENEXU 200 is a relay for AC voltage supervision with universal application; it protects the three phase network against over, under voltage, unbalance or earth faults in isolated networks. Beside the pure RMS value measurement ofline voltage the CSENEX-U 200 can detect the phase sequence, voltage unbalance and earth faults. TheCSENEX-U relay has been designed for controlling, protecting and monitoring industrial, utility distribution networks andstations. They can also be used as part of a protection scheme forfeeders, transformers and generators
Benefits
EC-RXA-V2 is a AUTOMATIC/MANUAL Generator controller module including protection for (STAND BY) GENSElS. It uses single advanced micro controller chip for an easy and trouble free GENSET control. it is cost ef fective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EC-RXA-V2 initiates an automatic GEN-SET start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from GEN-SET and transferred to mains.GEN-SET will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN-SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated.
Benefits
The Trip circuit of circuit breaker is normally wired through CB auxillary contacts and other interlocks (like spring charging full etc) and then connected to Trip solenoid coil of circuit breaker and control voltage source through fuse links.MRA- Pro-V2 continuously monitors these junction points. In the event of fault (like TC coil is open or short, TC coil supply is less than 40% or CB contact failure) in the trip circuit it immediately triggers the internal timer. After expiration of supervision time delay if the faulty condition persists then it is reported as fault by two output relay operation and CB failed LED indication. This scheme ensures that all trip circuit wiring (tripping route) from trip contact to the trip coil is supervised in either the breaker closed or open condition.
There are two modes of operation as under
a) Auto Mode: In this mode Trip circuit faulty status indication automatically gets reset once Trip circuit becomes healthy.
b) Manual Mode: In this mode Trip circuit faulty status indication will not be reset unless user reset it through a front RESET key through a single press.
To facilitate routine checkup there is a provision for TEST function inMRA- Pro-V2. User can enter into this mode by keeping the RESET key in pressed condition and then providing the auxiliary supply. To bring back to normal operation from this mode user has to switch off and then switch on the auxillary supply ofMRA- Pro-V2.
Benefits
The CAR type auxiliary are voltage operated relays mainly used in control and alarm units.They are available in two basic models CAR-H and CAR-S. These relays are available in 2 element and 3 elements model also. Each element can be energized separately also. The CAR series of relays are used in various applications such as:
It has been ensured to have consistent electrical and magnetic qualities while designing in armature, yoke and core materials. The coil is wound with high thermal rating to withstand the problems of overheating due to continuous rating.Similarly the contacts have been designed with silver / cadmium oxide alloy to have superior contact rating with minimum wear and tear. It is also ensured in the design construction that the contact pressure is maximum to ensure superior contact rating.
Benefits
The lockout relay CLR series are voltage operated single element electro-mechanical, hinged armature type relay mainly used in protection, control & alarm circuits. CLR relays are available in two basic model CLR-H and CLR-S. Lockout relay CLR-H is provided with hand reset contacts. CLR-S is self reset type.The CLR series of relays are used in various application such as:
The design of lockout relays is electro-mechanical, hinged armature type. It has been ensured to have consistent electrical and magnetic qualities while designing the armature, yoke and core materials. The coil is wound with wires of high thermal rating to withstand the problems of overheating due to continuous rating. It is also ensured that the coil though rated for the very short time will tolerated the high burden to ensure faster operation.
Benefits
The lockout relay CLR series are voltage operated single element electro-mechanical, hinged armature type relay mainly used in protection, control & alarm circuits. CLR relays are available in two basic model CLR-H and CLR-S. Lockout relay CLR-H is provided with hand reset contacts. CLR-S is self reset type.The CLR series of relays are used in various application such as:
The design of lockout relays is electro-mechanical, hinged armature type. It has been ensured to have consistent electrical and magnetic qualities while designing the armature, yoke and core materials. The coil is wound with wires of high thermal rating to withstand the problems of overheating due to continuous rating. It is also ensured that the coil though rated for the very short time will tolerated the high burden to ensure faster operation.
Benefits
In mPRO-200the protection feature is based on mathematical model ofmotor thermal image. The motor thermal overload protectionfunction calculates the heat accumulated in the rotor andstator based on the effective heating current , integrated overa time. The relay appropriately takes in to accountcooling of the winding by gradually emptying the accumulatedcurrent bucket. The relay displays the status of thermalcondition of motor windings as a % of maximum permissibleThermal capacity.If inverse overload characteristic (lN/) is selected then only theeffect of thermal memory phenomenon is enabled. If current inany of the three phases exceeds over-current setting l> as wellas accumulated thermal capacity (Thermal MEM) is >=100%then mPRO will trip the motor. If thermal memory isaccumulated then Relay Contact Reset depends on RelayReset selection (AUTO/MANUAL) and Thermal Reset selection(Disable/Enable).
Mechanical equipments such as pumps orfans can be quicklydamaged if it jams, resulting in a locked rotor stall. The MProwill trip when the running current exceeds the set value (Stall)value after the Stalled Rotor Time (tStall). Set this value toOFF, if stall protection of driven equipment is not requiredsince the thermal overload protection will protect the motor.This feature is blocked during the inrush of motor starting.mPRO provides protection against over temperature bymonitoring the temperature in the motor winding. Highwinding temperature is caused by phase unbalance, phasefail, high torque starting, insufficient cooling etc. mPRO willtrip the motor in running condition after PTC trip time (tPtc)expires. once temperature monitored via external PTCthermistor exceeds the PTC Trip value (PtcTrp).
Benefits