Electronics Timers

Minilec offers timers for various functions and applications, in various enclosures/sizes and with multi voltage options.

FEATURES
  • Single voltage and Multi-voltage
  • Single function and multi-function
  • Wide time range
  • Better repeat Accuracy
  • Models with Micro-Controller based design
  • Use of SMD Technology (S2 Series models)
FUNCTIONS
  • On Delay
  • Interval Delay
  • Cyclic ON/OFF
  • Multi-Attempt (for Engine Starting)
  • Star-Delta changeover
  • True off Delay

View Complete Details

Alarm Annunciators

Minilec Microprocessor Based Alarm Annunciators are designed to keep an alert and watchful eye on your plant and processes. The entire range has been designed with an insight into the modern day manufacturing plant and its future requirements. Minilec Alarm Annunciators are equipped with microprocessor-based design, super bright LED facia windows, site selectable, programmed sequences as per ISA standard and thoughtful provisions for troubleshooting and maintenance. Dynamic, Alert and Responsive These unique advantages have helped the Minilec Annunciators to be an icon in the power T and D industry and engineering establishments in India. The world class Minilec Annunciator has made its presence felt in Overseas markets.

FEATURES
  • 4 windows to 128 windows
  • Integral & Split models
  • Microprocessor based
  • Super bright LEDs for facia
  • Standard operating sequences
  • Any other custom- made sequences
  • NO-NC & Trip Non-Trip site selectable
  • Repeat relays
  • Supply fail annunciation / Indication
  • Choice of 3 window sizes
  • Choice of five colours
  • RS 232 / RS 485 Output Port
View Complete Details

Current Transformers

The basic application of current transformers are:
  • Lowering the very high primary current passing through bus bars, cables, or wires to 5A or 1A, a measurable quantity by measuring instruments.
  • Isolating the measuring instrument and protective devices from mains.
  • Reproducing proportionate primary current on its secondary side, as required for extending the range of the instruments.

Basically CTS are of different types:

BAR PRIMARY CURRENT TRANSFORMER (BPCT)For Currents of 100A and above the bus bars or cables are quite thick and it is easier to measure the currents without breaking the bus bars or cable by means of a Bar Primary current transformer which can be slipped over the bus bar or cable. These CTs are most commonly used as they are sturdy, compact and more economical.


WOUND PRIMARY CURRENT TRANSFORMER (WPCT) For currents below 100A, it is uneconomical to achieve the desired accuracy by employing Bar primary type CTs and the solution is Wound Primary C.T., where both primary and secondary are Wound over the core.


CLAMP ON CT'S NIPPEN clamp-on CT's enable quick and accurate current measurements on live circuits without disconnecting loads. Precision phase shift characteristics ensure accurate power or energy measurements conveniently. These are one of the accessories in our energy audit system.

View Complete Details

Single Phase Stabilizers

Frequent fluctuations or variations of power not only causes financial but manpower loss too! SENTRI SERVO CONTROLLED VOLTAGE STABILIZERS beast these happenings and provides all extra care needed to your valuable equipments.

SPECIFICATION
  • Rating : As Specified
  • Input Voltage Range : As Specified (Eg. 170V-270 V)
  • Input Supply Frequency : 45Hz-55Hz
  • Output Voltage: As specified (Eg. 230V/240V + 1%)
  • Voltage Regulation : + 1%
  • Rate of Correction: Usually 25V/ SEC/Phase but depends on rating
  • Efficiency: Better than 97 %
  • Waveform Distortion : Nil
  • Effect of Load Power Factor : Nil
  • Amibient Tempreture : 0-50C Max.
  • Type : 1 Phase

FEATURES
  • Output voltage sensing for voltage correction & for U/V & O/V trip
  • Overvoltage & undervoltage trip by means of contractor / relay's
  • Voltmeter with selector switch to see input & output voltages
  • Short circuit & overload protection by means of MCB/ FUSE MCCB
  • Adjustment : Output voltages adjustment of + 5V/ Phase will be
  • Adjustment : Output voltages adjustment of + 5V/ Phase will be provided by means of potentio meter on front plate.
  • Controls: Auto/Manual incase of auto mode failure you can set output voltage through manual mode.
View Complete Details

Analog Earth Tester

NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.

They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.

Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.

View Complete Details

Transducers

NIPPEN Power line Transducers give load independent and isolated DC outputs proportional to input parameters like current, voltage, frequency, power factor, active power, reactive power and dc isolation.


Features
  • A C VOLTAGE.
  • FREQUENCY
  • PF
  • ACTIVE POWER
  • REACTIVE POWER
  • D C ISOLATION
Features
  • Linear aux. power supply of 230V AC.
  • Conforms to IEC 60688 and IS 12784.
  • Short circuit protected and open circuit proof.
  • High input/output isolation 3kV/ 4kV.
  • DIN RAIL/ Back panel mounting arrangement.
  • Wide choice of outputs and suppressed ranges.
  • Current or voltage output.
  • Single or dual ISOLATION.
View Complete Details

Constant Voltage Transformer

In an Elent CVT, the AC mains powers the input winding which is widely separated physically from the isolated output winding. The input winding normally runs at very moderate Flux linkage levels. The output winding exhibits an intrinsic energy characteristic and this energy storage operates in conjunction with mains capacitor to produce self-generated AC flux field which is indirectly excited from the input winding. The result is instantaneous voltage regulation. No transient and spikes. Sinewave output. A perfect answer and remedy for every electronic equipment.

SALIENT FEATURES
  • No semiconductors or moving parts used, hence very high reliability
  • No feedback control used
  • Intrinsic current limiting and short circuit protection
  • Output voltage correction within Cycle ( 10 ms) from no load to full load for specified load and line variation
  • Short term over load capability
  • Energy storage for line loss up to 3 ms at typical loads
  • Higher input voltage control range, for loads less than rated load
  • Very high line transient/spike rejection capability and excellent input to output isolation characteristics
  • Output floating (optional)

RangeElent CVT is available in a wide range. from 50 VA to 10, 000 VA with load test conducted at unity power factor for all ratings. For configurations other than those mentioned above, please contact our office.

Model No. Capacity in VA Capacity at Unity Power Factory
CVT050 50 50 Watts
CVT100 100 100 Watts
CVT150 150 150 Watts
CVT250 250 250 Watts
CVT500 500 500 Watts
CVM1000 1000 1000 Watts
CVM1500 1500 1500 Watts
CVM2000 2000 2000 Watts
CVM2500 2500 2500 Watts
CVM3000 3000 3000 Watts
CVM4000 4000 4000 Watts
CVM5000 5000 5000 Watts
CVM10000 10000 10000 Watts
View Complete Details

Micro Switches

Features
  • 10 Amps
  • Single pole, 2, 3 & 4 Poles
  • Terminal - Screw / Solder / Push-On
View Complete Details

Toggle Switches

Features
  • 10 - 15 - 35 Amps
  • 1, 2, 3 & 4 Poles = 2 / 3 Positions
  • Stay put / Spring Return Combination
  • Terminal - Screw / Solder / Push-On
View Complete Details

Breaker Control Switches

Features
  • Lost Motion (Bell Alarm) Contacts
  • Sequence Locking Device
  • Lockable Handles
  • Pistol Grip & Lever Handles
  • Push-Pull Interlock System
  • Discrepancy Switch
  • Tee & Lever Lock Handles
  • Toggle Knob & Ball Handle
  • 30, 45, 60 & 90 Throw
View Complete Details

Motor Control Switches

Features
  • For Directly Switching On Reversing
  • Star-Delta
  • 2-Speed
  • 2-Speed Reversing
  • Inching of MOTORS of 1, 3, 5, 7.5, 10, 12.5 & 15 H.P . & Switching On of Motor of 18, 22, 30, 37 & 45 KW
View Complete Details

Proximity Switch

Features
  • Optimum tensile strength
  • Easy installation
  • Precise dimensions

Type

01-4

03-4

05-8

06-4

07-8

08-8

 

3 wire DC

3 wire DC

3 wire DC

3 wire DC

3 wire DC

3 wire DC

Dimensions Sensing Distance

11x28x16 4mm

10x20x25 8mm

17x28x17 8mm

12x24x12 4mm

20x36x20 8

10x36x18 8

Logic

PNP/NPN

PNP/NPN

PNP/NPN

PNP/NPN

PNP/NPN

PNP/NPN

Object

18x18x1

18x18x1

18x18x1

18x18x1

18x18x1

18x18x1

Frequency

Contact

NO/NC

NO/NC

NO/NC

NO/NC

NO/NC

NO/NC

Supply

10-30 VDC

10-30 VDC

10-30 VDC

10-30 VDC

10-30 VDC

10-30 VDC

Voltage

Load Current

200mA

200mA

200mA

200mA

200mA

200mA

Display

LED

LED

LED

LED

LED

LED

Circuit

Reverse

Reverse

Reverse

Reverse

Reverse

Reverse

Protection

Polarity

Polarity

Polarity

Polarity

Polarity

Polarity

Protection

IP 67

IP 67

IP 67

IP 67

IP 67

IP 67

Housing

 

 

 

 

 

 

Material

ABS Plastic

ABS Plastic

ABS Plastic

ABS Plastic

ABS Plastic

ABS Plastic

Wire sq mm

3C x 0.20

3C x 0.20

3C x 0.20

3C x 0.20

3C x 0.20

3C x 0.20

View Complete Details

CABLE TESTER/CABLE IDENTIFIER

  • Transmitter & receiver Included.
  • To identify & trace up to 16 cables.It can also be connected to heat and water supplying installation system.
  • Digital display on the receiver indicates the relative cable.
View Complete Details

Anemometer

CUP ANEMOMETER/BAROMETER/HUMIDITY/TEMP.

  • Air velocity : 0.9 to 35.0 m/s, ft/min., km/h, mile/h, knots.
  • Barometer : 10 to 1100 hPa, mmHg, inHg.
  • Humidity : 10% to 95% RH, Dew.
  • Temperature : 0 to 50 oC, oC/ oF.
  • All in one, hand held type.
  • Cup type probe, no wind direction.
  • Hold, Record (max., min.).
  • DC 1.5V battery (UM-4, AAA) x 4.
View Complete Details

SMD TEST CLIPS

  • The test clips used for measuring the SMD components(resistor, capacitor, inductor, diode.)
  • Cable length : appro x 90 cm.
View Complete Details

Contact Tachometer

  • Photo Tach. : 5 to 100, 000 RPM
  • Contact Tach. : 0.5 to 19, 999 RPM. Surface speed : m/min, ft/min.
  • Size : 215 x 65 x 38 mm.
  • Patented.
View Complete Details

Frequency Counter

  • 3 ranges, 2500 MHz, 100 MHz, 10 MHz.
  • Frequency, Period, Hold, Relative, Max., Min., Average, 8 digits LCD.
  • High sensitivity for VHF & UHF frequency.
  • Size : 173 x 80 x 35 mm, Portable type.
View Complete Details

Infrared Thermometer

  • 1, 000 oC no contact infrared Temp. measurement.
  • 1400 oC type K thermometer.
  • Dual laser for better targeting.
  • Large LCD display with back light.
  • D/S ratio value : 50/1.
  • Min., Max., Differential, Average, Lock mode.
  • Last measurement memory.
  • Hi/Lo Temperature Audio Alarm.
  • Adjustable emissivity value from 0.1 to 1.00.
  • Power supply : DC 1.5V battery (UM 4/AAA) x 2 PCs .
  • Dimension : 203 x 197 x 47 mm
View Complete Details

Manometer

  • Dual & differential input, 200 mbar x 0.1 mbar.
  • Unit : mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H2O, meter/H2O, Atmosphere.
  • Data hold, Memory (Max., Min.).
  • RS232/USB computer interface.
  • Application : Industrial, laboratory, schools, heating, ventilation, hospital, medical.
  • Size : 180 x 72 x 32 mm.
View Complete Details

Pressure Transducer

PRESSURE TRANSDUCER, 0 to DC 100mV

  • 6 models : 2/5/10/20/50/100/400 bar.
  • Zero pressure - 0 DCV, Full scale - 100 mV.
  • Power supply : DC 9V to 30V.
  • 4 wires : 2 wires for power, two wires for signal.
View Complete Details

Pressure Transmitter

2 WIRES PRESSURE TRANSMITTER

  • Range : 2, 5, 10, 20, 50, 100, 400 BAR.
  • Output : 4 to 20 mA DC. 4 mA = 0 pressure 20 mA = full scale pressure
  • 2 wires, both for signal and power supply.
  • Precision ceramic type pressure sensor.
  • External zero and span adjustment.
  • Output with socket, easy replacement.
  • Allow high cable load resistance, transmittercan install far away from the controller/incator.
  • Protection for the reverse wires connecting.
  • TR-PS2W can cooperate the " 4-20 mAController/Alarm/Indicator " CT-2012, then become a pressure controller and theindicating system. The user can control andmonitor the pressure value from far away.