Our Product / Services
Hand Pumps
2 Products availableHydraulic Pumps
2 Products availableRotameters
1 Products availableWe offer the best product range of Oval Gear Meter, 6400 MAG ELECTROMEGNETIC FLOW METER, TEP WATER METER, PORTABLE ULTRA SONIC FLOW METER and Domestic Single Jet Water Meter.
we are pleased to introduce our new torque make positive displacement flow meters for oil, diesel, petrol, kerosene or any slightly viscous non corrosive liquids; this is reset type, mechanical flow meters.
oval gear flow meter is a kind of positive displacement meter to measure the liquid flow or instantaneous flow of the pipe tube. It is a kind of accumulate meter. With characteristics of high accuracy, small change by the fluid viscosity, it is widely used to measure oil kind liquid, but it is forbidden to measure corrosive liquid
the measurement part of oval gear flow meter is posed by two elliptical gears mesh with each other and its shell (measuring room).the figure shows that the flow meter works by two elliptical gears to mesh with each other, its working process are as follows: p1 in the figure shows the pressure of liquid from inlet side, to show the outlet pressure, the bottom rotor has no rotating torque even it effected by the liquid pressure, but the above gears will move by the rotating
torque caused by liquid pressure. As the two gears mesh with each other, they move with o1, o2 axis of rotation direction of the arrow, meanwhile, gear o1 will push the liquid out from half-moon space. In the status of the above gear is driving gear, and the bottom gear is driven gear. Both of these two gears have rotating torque by the liquid pressure, and they move with the direction of the arrow to space the gear space is opposite to, the bottom gear is driving gear, and above gear is driven gear. The bottom gear pushes the liquid out from the half-moon space under the liquid press pushes liquid volume four times of measurement room. So, as long as the rotation of gears, the liquid volume can be counted. Ure. Such continues working, the gears turn a circle, it pushes liquid volume four times of measurement room. So, as long as the rotation of gears, the liquid volume ca n be counted. We are #1 supplier / manufacturer of gear flow meter, gear pump in india. Contact gear pump manufacturer, gear pump supplier in india.
cast iron oval gear meter has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability , applying in the petroleum , chemical , food industry etc.compact sixe ,
easy maintenance
easy to read and operate mechanical display
flexibility of installation options.
low pressure drop
accuracy : + / 0.5 %
flow range : 7-40 lpm
max temp : 70 c
max pressure: 7 bar
5 digital liquid crystal display
lit/gallon options
reset button
correction factor
operated on 2 alkaline battery
MODEL | OGM-25 | OGM-40 | OGM – 50 | OGM – 80 | OGM – 100 |
---|---|---|---|---|---|
SIZE | 1” | 1 1 / 2” | 2” | 3” | 4” |
MIN FLOW (L/min) | 12 | 25 | 30 | 100 | 160 |
MAX FLOW (L/min) | 120 | 250 | 300 | 1000 | 1600 |
ACCURACY (%) | K0.5% | K0.5% | K0.5% | K0.5% | K0.5% |
REPEATABILITY | 0.03% | 0.03% | 0.03% | 0.03% | 0.03% |
MAX VISCOSITY (CPS) | 1000 | 1000 | 1000 | 1000 | 1000 |
MAX PRESSURE (Mpa) | 3.4 | 1.8 | 1.8 | 1.6 | 1.6 |
torque make series 6400 ( full bore type ) are new range of bipolar pulsed dc full bore type electromagnetic flow meters. It is suitable for pipes with nominal diameters of dn 10 to dn 600 . They are based on faradays law of electromagnetic induction. The series 6400 meters features flanged construction and is available with choice of liner and electrode materials. Series 6400 has excellent accuracy and flow range ability. The meter is suitable for use on wide range of corrosive and aggressive range of conductive liquids.
based on faradays law of electromagnetic inductionsuitable for pipe sizes of diameters 10 mm to 600mmcoil assembly in hermetically sealed welded constructionchoice of ptfe / neoprene rubber / polyurethane linersintegral or remote transmitterfield interchangeable electronicsoptional led display for flow rate or totaliser indication in engineering units.no pressure lossabsolute zero stability and noise elimination.measurement independent of liquid properties.display of flow rate directly in user specified engineering unitsnegligible pressure lossmaintenance free design due to absence of any moving partshigh linearity due to characteristic magnetic field
an inferential, single jet, super dry straight reading type, hermetically sealed water meter with magnetic drive.
highly sensitive to low flow rates and very accurate over its entire flow range.having low loss of head which allows water to reach upper floors.sealed against tampering.totaliser leakproof, totally dry.long maintenance free life.self lubricating gears and bearings.
Accurac | 15mm | 20mm | |||||||
---|---|---|---|---|---|---|---|---|---|
Description | 15 mm | 20 mm | |||||||
CL-A | CL-B | CL-A | CL-B | ||||||
Meter threads (A) | ¾” BSP | 1” BSP | |||||||
Starts Registration at l/h | – | 16 | 14 | 20 | 18 | ||||
End connectionthreads (B) | ½” BSP | ¾” BSP | |||||||
Lower limit of flow,Qmin l/h | +5% | 60 | 30 | 100 | 50 | ||||
Transitional flow Qt l/h | +2% | 150 | 120 | 250 | 200 | ||||
Length of meter with couplings (L) | 250 mm | 290 mm | |||||||
Nominal flow Qn l/h | +2% | 1500 | 1500 | 2500 | 2500 | ||||
Maximum flow, Qmax l/h | +2% | 3000 | 3000 | 5000 | 5000 | ||||
Length of meter without coupling (D) | 110mm | 165 mm | |||||||
Test Pressure MPa | 2 | ||||||||
Temperature suitability ºC | 60ºC | ||||||||
Height (C) | 76 mm | 78 mm | |||||||
Dial Registration kl | 99999 | ||||||||
Width (E) | 72 mm | 72 mm | |||||||
Smallest reading l | 0.2 | ||||||||
Weight withcouplings | 780 gms | 900 gms |
the tds 100h handled clamp-on ultrasonic flow meter is of the most powerful flow meters available for liquid measurement utilization of our proprietary ultrasonic transit- time measurement and signal quality tracking technologies allow accurate flow measurement of the liquid flow rate from outside of a pipe.
the tds-100 flow meters carefully designed so that it is very compact and easy to use. A user can use one hand to hold as well as operate the flow meter main unit. The user interface is self explanatory and very easy to follow. Besides, the unique clamp on fixture design makes he non-intrusive nature of the clamp on technique, there is no pressure drop no moving parts, no leaks and no contamination.
features and benefitswide flow measurement range, from 0.01 m/s to 32 m/s
bi-directional measurement, totalize for net, positive and negative flow.
high accuracy, better than 1 % of velocity
wide pipe size range, from dn 15 to dn 6000 mm
suitable for all commonly used pipe materials
rechargeable battery with 10 hours of operation
built in data logger
self explanatory user interface.
windows pc software for data down-load and real time data display
single quality tracking and self-adjusting capabilities that automatically match transducer to pipe material
compact light weight enclosure @ 538g for the handset
can also be deployed as a remote rtu for long term flow monitoring application
easy and economical installation
non invasive. No pipe disturbance. No moving parts. No pressure drop.
ideal for both clean and opaque liquid flows.
applicationsthe tds-100h flow meter is ideal for flow surveys and closed pipe applications where non-invasive measurement of liquids is required. Benefited from our advanced digital signal processing technology, the handled flow meter works reliably in both clean and opaque liquid flow. Examples of applications include:
power plants (nuclear power plants, thermal & hydropower plants) heat energy boiler feed water.
energy consumption supervision and water conservation management.
metallurgy and mining application (e.g. Acid recovery)
marine operation and maintenance.
pulp and paper.
pipeline leak detection, inspection, tracking and collection.
energy measurement and balancing.
network monitoring.
water, including hot water, chilled water, city water, sea water etc.
sewage and drainage water with small particle quantity.
oil, including crude oil, lubricating oil, diesel oil, fuel oil, etc
chemicals, including alcohol, acids, etc
solvents.
beverage and food processes.
hvac hot and cool water, water / glycol solutions
water and waste treatment
orifice plate is used for flow rate measuring in pipe systems. With orifice plate, pressure drop is created. Based on the magnitude of pressure drop, flow rate can be calculated. Orifice plate calculator can be used for both liquids and gases. Fluid is considered as in- compressible, so density (rho) and temperature (t) are constant through tube. Also, gas is considered as ideal.
suitable for liquids, gases and steam applications in line sizes from dn15 to dn200 and at pressures up to 100 bar, it combines all the major components needed for an orifice plate installation in one assembly. This eliminates the need for users to design, source and in- stall a separate manifold, transmitter and impulse piping, typically cutting the cost of installation and commissioning.
the all-in-one design also offers enhanced accuracy and a faster speed of response, with no problems caused by issues such as long or blocked impulse lines, or impaired signals due to condensation in gas system impulse lines or gas bubbles in liquid lines.
the compact orifice flow meter series is designed for closed loop control and general purpose monitoring applications. This design lowers the total installed cost of dp flow measurement points eliminating the need for fittings, impulse tubing, valves, adapters and manifolds by providing a single device packaged together for simplified installation. By integrating pressure transmitters with the compact orifice primary element, we deliver the highest performing flow meters which arrive assembled, calibrated, pressure tested, and ready to install.
the conditioning compact orifice is ideal for applications with limited pipe run. Only requiring 2 pipe diameters from an upstream disturbance (double elbows, valves, reducers), the conditioning compact orifice delivers + 0.5% accuracy.
savings in excess of 50% can be realized when compared to a traditional orifice plate installation.reduced straight pipe runless expensive than an orifice plate installationaccurate and repeatablecentering mechanismbased on asme / iso corner tap design
in addition to the conditioning compact orifice, an orifice plate offering is available with the conditioning orifice plate technology and provides the same accuracy and performance you achieve with the compact design.throttling device is a differential pressure flow meter sensors, with the differential pressure transmitter and display devices (or computer) supporting the use, enabling the measurement of fluid flow and achieve the accumulation, display and control. Because of its simple structure, easy installation, the use of reliable and suitable for a wide range of (standard throttling device diameter measurements available from 50mm-12mm, a special application of throttle device can also be as small as 20mm diameter as large as 3000mm; measuring temperatures of up to 550c pressure up to 40mpa: measured the types of media is greater) and standard throttling device also has no separate calibration of the advantages of industrial automation control flow measurements during the course of one of the main instruments.
our company not only the production of conventional structure, throttling device, but also produce changes in the scope to meet the on-site a large number of process flow throttling device may change orifice throttling device.
Type |
Orifice Flow meter |
---|---|
Accuracy | +_0.5% |
Body material | 316L |
Wetted material | 316L |
Seal material | PTFE |
Structure | Orifice plate , valves ,diff-pressure |
Output | 4-20mA with HART |
Display | LCD flow rate, total flow |
Power supply | 24VDC |
Pressure | Max 16BAR |
Temperture | 10—300 centigrade |
Connection | G-standard Flange |
FEATURES:
ITEM |
FLOW RATE |
INLET X OUTLET |
ADBLUE METER |
100 LPM |
1” X 1” |
Single Jet Class A & B, 15mm -20mm ( - )
An inferential, single jet, super dry straight reading type, hermetically sealed water meter with magnetic drive.
STANDARDS:-
Complies with class A & B of IS-779/94 also ISO & EEC.
CONSTRUCTION:-
OPTIONS:-
TEP Water meters with EEC Mark
MODEL FM-120:-
DESCRIPTION |
SPECIFICATIONS |
|
MODEL |
FM-120-1 |
FM-120-2 |
MEASUREMENT |
Liters / us Gallon |
Liters / us Gallon |
MAX PRESSURE |
3 Bar |
3 Bar |
FLOW RATE |
150 LPM |
120 LPM |
INLET X OUTLET |
BSPF / NPT 1.5” |
BSPF / NPT 1” |
PRECISION |
+1% |
+1% |
NET WT |
15 kg |
12 kg |
GROSS WT |
16 kg |
13 kg |
DIMENSION |
520 x 260 x 350 mm |
520 x 260 x 350 mm |
TORQUE make Series 6500 is a new range of Bipolar Pulsed DC Insertion Type Electromagnetic Flow meter. It is suitable for pipes with nominal diameters of 100 mm & above. The Flow meter Is based on Faradays law of Electromagnetic Induction.Series 6500 has excellent accuracy and flow range ability within its class. The meter is suitable for use on wide range of corrosive and aggressive range of conductive liquids.
Based on Faradays law of electromagnetic induction.Suitable for pipe sizes of diameters 100 mm & aboveWith or without Integral Transmitter.Use of Isolating Ball Valve and Pressure Seal arrangement permits ease of mechanical Insertion and removal without disturbing the flowAbsolute zero stability and noise elimination due to pulse D.C. excitationMeasurement independent of liquid propertiesOptional inbuilt potentiometer provides full scale flow rate adjustments.Negligible pressure loss.Maintenance free design due to absence of any moving parts.Display of flow rate directly in user specified engineering units
Water Supply NetworksChemical and Process IndustriesPharmaceutical IndustryWaste- Water ManagementSugar, Food and Beverages industriesEffluent Treatment Plants
Applications:-
Turbine flow meter transducer adapts to measure the liquid rate and total flow rate of low viscosity and for clear liquid.
It can be widely used in the fields of petrol, chemical Industry , Metallurgy , Scientific research for measuring or control.
Several output display methods can be selected.
Technical specification:-
High-accuracy: 0.2%, 0.5% , 1%
Erode-resistant applicable for sea water, ammonia , etc.
Bi-Direction measuring bi-direction flow (optional)
Multi-output pulse , 4-20mA DC, total and rate display in the field.
Power-supply 5-24 V DC,
Explosion-proof Ex d II BT4/Ex ib I
Pipeline range 6, 10, 15, 25, 40, 50, 80, 100, 150, 200, 250, 300 mm.
Turbine Flow meter |
Description |
|||||
Type |
A |
Flow sensor pulse output three-wire system, +12V power supply |
||||
B |
Local display , powered by 3.6V battery |
|||||
C |
Local display with 4~20mA ou pulse output,powered by24v. |
|||||
D |
Flow transmitter 4~20mA output,powered by 24V: |
Nominal drift diameter |
4 |
Normal flow range m3/hr |
0.04~0.25 |
Extended flow range m3/hr |
0.04~0.4 |
|||
6 |
0.1~0.6 |
0.06~0.6 |
||||||
10 |
0.2~1.2 |
0.15~1.5 |
||||||
15 |
0.6~6 |
0.4~8 |
||||||
20 |
0.8~8 |
0.45~9 |
||||||
25 |
1~10 |
0.5~10 |
||||||
32 |
1.5~15 |
0.75~15 |
||||||
40 |
2~20 |
1~20 |
||||||
50 |
4~40 |
2~40 |
||||||
65 |
7~70 |
3.5~70 |
||||||
80 |
10~100 |
5~100 |
||||||
100 |
20~200 |
10~200 |
||||||
125 |
25~250 |
12.5~250 |
||||||
150 |
30~300 |
15~300 |
||||||
200 |
80~800 |
40~800 |
||||||
Explosion protection |
Not marked, without explosion protection |
|||||||
B |
Explosion protection type |
|||||||
Precision class |
A |
Precision : Class 0.5 |
||||||
B |
Precision : Class 1.0 |
|||||||
NOTE:- Sensors with pipe diameter of DN4~DN40 are of thread connections with maximum operating pressure of 6.3 Mpa. Sensors with pipe diameter of DN50~DN200 are of flange connections with maximum operating pressure of 2.5 Mpa. Sensors with pipe diameter of DN4~DN10 are provided with front and rear straight pipe sections and filters. Please specify whcn placing an order if flange connections are required for pipe diameter of DN15~DN40 Please specify when placing an order for high pressure type and special requirements. |
Applications:-
Turbine flow meter transducer adapts to measure the liquid rate and total flow rate of low viscosity and for clear liquid.
It can be widely used in the fields of petrol, chemical Industry , Metallurgy , Scientific research for measuring or control.
Several output display methods can be selected.
Technical specification:-
High-accuracy: 0.2%, 0.5% , 1%
Erode-resistant applicable for sea water, ammonia , etc.
Bi-Direction measuring bi-direction flow (optional)
Multi-output pulse , 4-20mA DC, total and rate display in the field.
Power-supply 5-24 V DC,
Explosion-proof Ex d II BT4/Ex ib I
Pipeline range 6, 10, 15, 25, 40, 50, 80, 100, 150, 200, 250, 300 mm.
Turbine Flow meter |
Description |
|||||
Type |
A |
Flow sensor pulse output three-wire system, +12V power supply |
||||
B |
Local display , powered by 3.6V battery |
|||||
C |
Local display with 4~20mA ou pulse output,powered by24v. |
|||||
D |
Flow transmitter 4~20mA output,powered by 24V: |
Nominal drift diameter |
4 |
Normal flow range m3/hr |
0.04~0.25 |
Extended flow range m3/hr |
0.04~0.4 |
|||
6 |
0.1~0.6 |
0.06~0.6 |
||||||
10 |
0.2~1.2 |
0.15~1.5 |
||||||
15 |
0.6~6 |
0.4~8 |
||||||
20 |
0.8~8 |
0.45~9 |
||||||
25 |
1~10 |
0.5~10 |
||||||
32 |
1.5~15 |
0.75~15 |
||||||
40 |
2~20 |
1~20 |
||||||
50 |
4~40 |
2~40 |
||||||
65 |
7~70 |
3.5~70 |
||||||
80 |
10~100 |
5~100 |
||||||
100 |
20~200 |
10~200 |
||||||
125 |
25~250 |
12.5~250 |
||||||
150 |
30~300 |
15~300 |
||||||
200 |
80~800 |
40~800 |
||||||
Explosion protection |
Not marked, without explosion protection |
|||||||
B |
Explosion protection type |
|||||||
Precision class |
A |
Precision : Class 0.5 |
||||||
B |
Precision : Class 1.0 |
50mm -500mm (2 - 20 )
A removable mechanism type Woltmann water meter with magnetic drive and vacuum sealed register.
STANDARDS:-
Conforms to ISO 4064 , Class-B
APPLICATION:-
Water Distribution Network industrial / Commercial water supply
FEATURES:-
OPTIONS:-
salient features:-
applications:-
| ||
last updated on tuesday, 17 february 2015 09:15 |
.
mass flow meter is working on the based of carioles force principle basically used for all the
liquid gas, steam, solid liquid mixture.
measuring range : 0-150 t/ h , accuracy :k0.20 %.
overview:-
we can provide wide flow measurement products. For almost all industries, we can offer complete measurement programs and perfect services.
we provide the flow meters as below.
mass flow meter, electromagnetic flow meter vortex flow meter , metal tube rotameter and ultrasonic flow meter.