Our product range contains a wide range of Corsair 135 Micro Catheter, Corsair 150 Micro Catheter, Fielder Xt Guide Wire, Miracle Guide Wire and Fielder Guide Wire
Corsair 135 Micro Catheter
Brand NameAsahi
Crossing tortuous lesions Saving contrast media with super-selective tip injection Providing support for guide wire crossing Maintaining the channel for guide wire exchange 135cm length for antegrade approachor reshaping
Crossing tortuous lesions Saving contrast media with super-selective tip injection Providing support for guide wire crossing Maintaining the channel for guide wire exchange 150cm length for antegrade approachor reshaping
Guide wire with a higher tip load than Fielder XT-R, facilitating entry into the chronic occluded lesion. Is a polymer sleeve covered wire providing excellent lubricity and trackability in tortuous vessels. The tapered tip provides extreme precision for the treatment of complex lesions such as sub-total occlusions and long diffused lesions.
Spaecial Guidewire - distal coil coated with polymer sleeve & further coated with a hydrofilic coating, provide advanced slip performance & tackability for highly stenosed lesion & tortuous vessels, very good tourque performance, Combines both slide and torque performance, Primary wire used in the retrograde technique of recanalisation of CTO.
The ASAHI Gaia has the same intended use and similar technological characteristics such as components, design, materials, sterilization method, shelf life and operating principles as the predicate devices. Performance data demonstrates that the device functions as intended, and is as safe and effective as its predicates.
Contributes to stable device delivery Well balanced reinforced shaft enhances guiding catheter Minimal loss of steerability on tortous vessels Useable as a frontline guide wire with easy control for branch selection Superior torque response
Stiff wire shaft provides extra support for delivery of interventional devices in extreme cases.Features0.014" Guide wire0.7gf Tip loadCore-to-tip designHydrophobic coating on spring coil4cm Spring coil length4cm Radiopaque segmentAvailable in 180cm and 300cm lengths
Spaecial Guidewire - distal coil coated with polymer sleeve & further coated with a hydrofilic coating, provide advanced slip performance & tackability for highly stenosed lesion & tortuous vessels, very good tourque performance, Combines both slide and torque performance, Primary wire used in the retrograde technique of recanalisation of CTO.
PTCA Rinato GuidewireNot simply Hydrophilic over-coated, but this Guidewire was designed anew from core wire in order for exceeding performance of Hydrophilic coating. Improved torqueability, Improved support performance, while excellent trackability of ASAHI NEOS kept unchanged. Improved support performance at the range of 50mm-100mm from tip, which is most often used with/for mounting intervention device(s).