Our Products
Conduit Pipe
2 Products availableTesting Equipments
2 Products availableLevel Switches
2 Products availableSafety Switches
2 Products availableFlexible Conduits
2 Products availableSockets
2 Products availableOur Complete range of products are Standard Feed through Terminal Blocks, Micro Terminal Blocks., High Voltage Terminal Blocks, Thermocouple Terminal Blocks and Spring Loaded Feed through Terminal Blocks.
2.5 sq.mm Feed Through Terminal Blocks are the most Versatile terminals for control, Automation, Instrumentation and Power Distribution applications. These Terminal Block are ideal choice for use in High Temperature applications.
These Terminal Blocks can be mounted on standard rail and available for wire sizes 0.25 to 2.5 sq mm.These Terminal Blocks have marker holding recesses to accept marking tags for circuit identification. Cross connection can be achieved with the aid of shorting links / sleeves & screws. The specially designed Knock Out at the centre must be removed to facilitate Permanent shorting.
TECHNICAL DATA | |||
Rated Voltage | 800 V | ||
Rated Current | 24 A | ||
Tightening Torque | 0.4 Nm | ||
Housing Material | Melamine | ||
Product Function | Feed Through | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32 Rail | ||
Screw Size | M2.5 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 2.5 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 12 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 2.5 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 1.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 4 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 1.5 mm² | ||
Stripping Length | 9 mm | ||
Internal Cylindrical Guage | A3 |
DIMENSIONS | |||
Height with DIN 32 rail | 46.5 mm | ||
Length | 36.5 mm | ||
Width (Thickness) | 6 mm |
These Terminal Blocks are extremely compact and are used in applications with space constraints. |
TECHNICAL DATA | |||
Rated Voltage | 500 V | ||
Rated Current | 32 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | Micro/Mini | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 15 Rail | ||
Screw Size | M3 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 4 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 10 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4.0 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6.0 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 8 mm |
DIMENSIONS | |||
Height with DIN 15 x 5 mm rail | 30.4 mm | ||
Length | 27 mm | ||
Width (Thickness) | 6 mm |
The CHV series Terminal Block have been specially designed for extremely high voltage (1000 V) application. A specially designed flexible foot enables easy mounting and dismounting from the mounting rail with the help of a screw driver.These Terminal Blocks have marker holding recesses to accept marking tags for circuit identification. Cross connection can be achieved with the aid of shorting links / sleeves & screws. |
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 32 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | High Voltage | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Screw Size | M3 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 10 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 12 mm |
DIMENSIONS | |||
Height with DIN 32 rail | 68.2 mm | ||
Height with DIN 35 x 15 mm rail | 70.8 mm | ||
Height with DIN 35 x 7.5 mm rail | 63.4 mm | ||
Length | 52 mm | ||
Width (Thickness) | 6 mm |
These Terminal Blocks are used with thermocouple wires in measurement applications. As per DIN 43713 & DIN 43714 the current carrying element of the Terminal Block is made of the same material as the Thermocouple wire. These special current carrying elements ensure that there is no loss of potential at the connecting points. |
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 10 A | ||
Tightening Torque | 0.4 Nm | ||
Housing Material | Polyamide | ||
Product Function | Thermocouple | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Screw Size | M2.5 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 4 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 2.5 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 14 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 2.5 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 1.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 4 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 1.5 mm² | ||
Stripping Length | 8 mm |
DIMENSIONS | |||
Height with DIN 32 rail | 51.1 mm | ||
Height with DIN 35 x 15 mm rail | 53.7 mm | ||
Height with DIN 35 x 7.5 mm rail | 46.2 mm | ||
Length | 43 mm | ||
Width (Thickness) | 10 mm |
These Terminal Block are preferred for connections that involves safety requirements of the electric supply industry (ESI) standards, in addition to the high torque screws, |
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 32 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | Feed Through | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Screw Size | M3 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 10 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 12 mm |
DIMENSIONS | |||
Height with DIN 32 rail | 68.2 mm | ||
Height with DIN 35 x 15 mm rail | 70.8 mm | ||
Height with DIN 35 x 7.5 mm rail | 63.4 mm | ||
Length | 52 mm | ||
Width (Thickness) | 6 mm |
These blocks are used to connect multiple wires in single Terminal Block, thereby eliminating reliability problems encountered when connecting multiple wires in a single clamp. |
TECHNICAL DATA | |||
Rated Voltage | 630 V | ||
Rated Current | 32 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | Multiple Connection | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Screw Size | M3 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 mm² | ||
Conductor Cross Section AWG/Kcmil max | 10 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 9 mm | ||
Internal Cylindrical Guage | A4 |
DIMENSIONS | |||
Height with DIN 32 rail | 53.3 mm | ||
Height with DIN 35 x 15 mm rail | 56.5 mm | ||
Height with DIN 35 x 7.5 mm rail | 49.5 mm | ||
Length | 46.5 mm | ||
Width (Thickness) | 6 mm |
2.5 sq.mm Feed Through Terminal Blocks are the most Versatile terminals for control, automation, instrumentation and power distribution applications. A specially designed flexible foot enables easy mounting and dismounting from the Din Rail with the help of a screw driver.
These Terminal Blocks have marker holding recesses to accept marking tags for circuit identification. Cross connection can be achieved with the aid of shorting links / sleeves & screws.
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 24 A | ||
Tightening Torque | 0.4 Nm | ||
Housing Material | Polyamide | ||
Product Function | Feed Through | ||
Wire Entry Orientation | Side Entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Screw Size | M2.5 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 2.5 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 12 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 2.5 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 1.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 4 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 1.5 mm² | ||
Stripping Length | 8 mm | ||
Internal Cylindrical Guage | A3 |
DIMENSIONS | |||
Height with DIN 32 rail | 51.1 mm | ||
Height with DIN 35 x 15 mm rail | 53.7 mm | ||
Height with DIN 35 x 7.5 mm rail | 46.2 mm | ||
Length | 43 mm | ||
Width (Thickness) | 5 mm |
These Terminal Blocks are preferred for applications where the connections are subjected to severe vibrations.The wire is crimped to ring /fork type Lug (Ferrule) and is screwed on to flat current bar on the Terminal Block. The fastening nut always remains captive in the hinged plastic carrier. The Hinged Carrier should be lifted to insert the lugs and then snapped back into position. The nut can then be fastened to complete the connection. By the virtue of the hinged design the Terminal Blocks apart from shrouding the live parts, providing IP20 protection, saves considerable time in wiring. |
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 41 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | Feed Through | ||
Wire Entry Orientation | Side entry | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Stud Size | M3 | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 1.5 mm² | ||
Conductor Cross Section Stranded max. | 6 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 8 AWG | ||
Conductor Cross Section Solid min | 1.5 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 1.5 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 6 mm² |
DIMENSIONS | |||
Height with DIN 32 rail | 52.1 mm | ||
Height with DIN 35 x 15 mm rail | 54.75 mm | ||
Height with DIN 35 x 7.5 mm rail | 47.25 mm | ||
Length | 47 mm | ||
Width (Thickness) | 9 mm | ||
These blocks are used for measuring, control, regulatory circuits and for current transformer connection application. These blocks are component carrier base. Various pluggable component carriers can be installed easily. These component carriers have bulit in protection against incorrect polarity.
CPD1 & CPF component plugs are suitable for these terminal block.
TECHNICAL DATA | |||
Rated Voltage | 1000 V | ||
Rated Current | 10 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Wire Entry Orientation | Side | ||
Mounting Possibility | DIN 32/DIN 35/DIN 35-15 Rail | ||
Operated by | Screw Driver | ||
Rated Surge Voltage | 8 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 24 AWG | ||
Conductor Cross Section AWG/Kcmil max | 10 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 8 mm | ||
Internal Cylindrical Guage | A4 |
DIMENSIONS | |||
Height with DIN 32 rail | 51.5 mm | ||
Height with DIN 35 x 15 mm rail | 53.5 mm | ||
Height with DIN 35 x 7.5 mm rail | 46 mm | ||
Length | 58.5 mm | ||
Width (Thickness) | 6 mm |
1) Wire Protector Type Connection.2) Smallest foot print for 1 sq mm wire termination in 3.5 mm Pitch.
TECHNICAL DATA | |||
Pin Spacing | 3.5 mm | ||
Rated Voltage | 300 V | ||
Rated Current | 6 A | ||
Tightening Torque | 0.2 Nm | ||
Housing Material | Polyamide | ||
Product Function | Single Level for PCB | ||
Wire Entry Orientation | Perpendicular to PCB | ||
Number of Poles | 2 and 3 | ||
PCB Hole Size Diameter | 1.1 mm | ||
Mounting Possibility | PCB | ||
Screw Size | M2 | ||
Operated by | Screwdriver |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.5 mm² | ||
Conductor Cross Section Stranded max. | 1 mm² | ||
Conductor Cross Section AWG/Kcmil min | 24 AWG | ||
Conductor Cross Section AWG/Kcmil max | 18 AWG | ||
Stripping Length | 5 mm |
DIMENSIONS | |||
Height | 6.8 mm | ||
Width (Thickness) | 8.3 mm |
1)Quick connecting Spring Clamp type connection.
2)Suitable for wire size upto 2.5 sq mm.
3)Available in Single Pole stackable Version
TECHNICAL DATA | |||
Pin Spacing | 5.08 mm | ||
Rated Voltage | 300 V | ||
Rated Current | 15 A | ||
Housing Material | Polyamide | ||
Product Function | Single Level for PCB | ||
Wire Entry Orientation | 45 Deg To PCB | ||
PCB Hole Size Diameter | 1.2 mm | ||
Mounting Possibility | PCB | ||
Operated by | Screwdriver |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.5 mm² | ||
Conductor Cross Section Stranded max. | 2.5 mm² | ||
Conductor Cross Section AWG/Kcmil min | 28 AWG | ||
Conductor Cross Section AWG/Kcmil max | 12 AWG | ||
Stripping Length | 8 mm |
DIMENSIONS | |||
Height | 13 mm | ||
Width (Thickness) | 14.3 mm |
A perfect solution for extremely compact wiring applications, these terminal block are modular and can be stacked to form multi-pole terminal block assemblies. |
ECHNICAL DATA | |||
Rated Voltage | 500 V | ||
Rated Current | 32 A | ||
Tightening Torque | 0.5 Nm | ||
Housing Material | Polyamide | ||
Product Function | Feed Through | ||
Wire Entry Orientation | Side | ||
Mounting Possibility | Panel/Surface | ||
Screw Size | M3 | ||
Operated by | Screwdriver | ||
Rated Surge Voltage | 4 KV | ||
Pollution Degree | 3 |
CONNECTION DATA | |||
Conductor Cross Section Stranded min. | 0.2 mm² | ||
Conductor Cross Section Stranded max. | 4 mm² | ||
Conductor Cross Section AWG/Kcmil min | 22 AWG | ||
Conductor Cross Section AWG/Kcmil max | 10 AWG | ||
Conductor Cross Section Stranded with Ferrule/Lug min | 0.2 mm² | ||
Conductor Cross Section Stranded with Ferrule/Lug max | 4 mm² | ||
2 Conductors with same Cross Section Stranded min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded max | 2.5 mm² | ||
Conductor Cross Section Solid min | 0.2 mm² | ||
Conductor Cross Section Solid max | 6 mm² | ||
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min | 0.2 mm² | ||
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max | 2.5 mm² | ||
Stripping Length | 9 mm | ||
Internal Cylindrical Guage | A4 |
DIMENSIONS | |||
Height | 28.5 mm | ||
Length | 27 mm | ||
Width (Thickness) | 6 mm |