1 Products availableWe offer the best product range of Single Tube Flowmeter, Table Model VA Flowmeter, Variable Area Flowmeter, Four Tube Flowmeter and Five Tube Flowmeter.
Anaesthetic flowmeters are available in single tubes versions. Available in various model.
Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen and Air.
Features:-
1) 1 - 20 LPM O2 or Air for BPC Flow meter testing
2) 10 - 70 LPM O2 or Air for anesthesia machine outlet flow testing
3) 50 - 500 LPM O2 or Air for Regulator flow testing
4) 100 - 1000 LPM O2 or Air for Regulator flow testing
5) 300 - 3000 LPM O2 or Air for Regulator flow testing
6) 5 - 60 LPM Air for vacuum application
DESCRIPTIONThe CM flowmeters provide an economical means of flow rate indication and control for general use, and laboratory applications. The instruments are ideal for common applications like purging services, cooling water flow indication, bearing lubrication, carrier gas flow rate indication, fuel flow indication, in chromatography, atomic absorption, and indication and control of doping gas in electronic crystal growing furnaces. The table models are generally used for laboratory applications and also for calibration/verification of line instruments.
DESIGN FEATURES :
Flowmeter are used for measuring flow in Anesthesia Machine
Featurs:
Download 01
Download 02
Download 03
Download 04
FUNCTION
GENERAL OPERATION
The Flow Head integrates 02 and N20 (the N20 is optional).
The O2 Air and N20 needle valves gas supply pressure is externally regulated to 400Kpa¢10Kpa as per standard.
The N20 channel incorporates a pressure cut-off valve. The O2 supply pressure in the circuit controls the output pressure of the pressure out-oft valve. Under all conditions of operation, the N20 flow shall reach zero before the O2 flow. ln this flow head the N20 pressure switch shall cut oft the ow of N20 before the O2 pressure drops below 50115Kpa.
Anaesthetic flowmeters are available in 2 – 5 tubes versions. The flowmeters (2-5 tube versions) can be supplied with or without Anti Hypoxia Device.
The housings are made from Aluminum and fitted with fine adjustment valves for easy control of the anaesthetic gases. The front cover is made from moulded acrylic. The devices have a phosphorescent “glow in the dark” (normally white) background for easy reading even in case of sudden darkness.
The knobs are made from finest quality ABS. The Oxygen knob has a touch coded profile and all the knobs are colour coded as per ISO 5358 requirements.
Internal gas connections are made using polyurethane tubes and Festo type connections. A non return valve in the downstream of the AHD ensures no flow of N2O in the respiratory circuit in the event of single fault condition when Oxygen line gets blocked.
Various options of inlet and outlet connections are available
Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen, Nitrous oxide, Carbon dioxide, Xenon, and Air.
Anaesthetic Rotameters units with control valve system can be of 1 tube, 2 tubes, 3 tubes and so on as per user requirement. It comes as a complete unit for fitting on the Anaesthesia machine.
Flow Range
Connections
Function
The Flow Head incorporates the following Functions
GENERAL OPERATION
The Flow Head integrates O2 and N20.
The 02 Air and N20 needle valves gas supply pressure is externally regulated to 400Kpai10Kpa as per standard.
The N20 channel incorporates a pressure cut-oft valve. The 02 supply pressure in the circuit controls the output pressure of the pressure cut-off valve. Under all conditions of operation, the N20 ow shall reach zero before the 02 flow. In this ow head the N20 pressure switch shall cut off the flow of N20 before the 02 pressure drops below 50:15Kpa.
PERFORMANCE STANDARDS
Standard ow conditions defined at 20°C, 101 .3Kpa, (760mmHg) Conforms to ISO 5358 requirements.
Flow Tubes
Flow Control Valves
PRESSURE CUT-OFF VALVE
ASSEMBLY
Leakage from atmosphere shall not exceed 108ml/min. when a vacuum of 80cm H20 is applied to all internal.
MATERIALS
Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen and Air.
Anaesthetic Rotameters units with single control valve system of 2 tubes as per user requirement. It comes as a complete unit for fitting on the Anaesthesia machine for veterinary used .
DESIGN FEATURES :
DESCRIPTIONThe CM series 8000 & 9000 flowmeters provide an economical means of on-line flow rate indication of various fluids. The instruments are ideal for process industry and also extensively used as master instrument for calibration of other flowmeters.
DESCRIPTIONThe CM series of flowmeters provide an economical means of flow rate indication and control for general use, and laboratory applications. The instruments are ideal for common applications like purging services, cooling water flow indication, bearing lubrication, carrier gas flow rate indication, fuel flow indication, in chromatography and atomic absorption and indication and control of doping gas in electronic crystal growing furnaces.