2-position Manual Valves

Application Single or double-acting cylinders.

Actuation Lever operated, detent positioned.

Functions Pos. 1 Oil is directed to advance side of cylinder, oil from retract side goes to reservoir; cylinder holds with pump shut off. Pos. 2 Oil goes to retract side of cylinder; cylinder holds with pump shut off. When using as a 3-way valve for single-acting cylinders, port A or B is plugged.

Used on these pumps P460, PA6D, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.

NOTE:9504 can be remote mounted with a 9510 Subplates.

NOTE:A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required.
For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.
For valve 9582, order two 12001 and two 10856 cap screws.

NOTE:Valves 9501, 9502, 9504 and 9507 can have a port blocked or have a closed center position. When a port is blocked and the valve is shifted to the blocked port, the pump will generate excessive heat. An electric or rotary air pump can either be turned off manually or with a pressure switch. Reciprocating air pumps may be adjusted to stall out and stop.

NOTE:Gauge ports monitor pump pressure only, not pressure to the hydraulic cylinder(s).

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9504 S.A. & D.A. Manual 3/4-way, 2 Pos. Yes Yes No 4.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders

View Complete Details

Non-Interflow Manual Valves

3-WAY/3-POSITION (CLOSED CENTER) NON-INTERFLOW MANUAL VALVE WITH POSI-CHECK

Application Single-acting cylinders.

Actuation Lever operated, detent positioned.

Functions Pos. 1 Oil is directed from pump to cylinder and holds with pump shut off; line to reservoir is blocked. Pos. 2 All oil is open to reservoir through tank line.

Center pos. Cylinder pressure is held; pump should be shut off.

Used on these pumps P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.

10, 000 PSI., 3/8" PORTS, 5 GPM MAX FLOW RATE.

NOTE:APressure Switchand/or Gauge (AnalogorDigital) may be attachedif desired.

NOTE:Also, valve may be remote mounted with a9510 Subplates.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use aLoad Lowering Valve (No. 9596)orCounter Balance Valve (No. 9720)in conjunction with the directional valve used in your application.

NOTE:Valves 9501, 9502, 9504 and 9507 can have a port blocked or have a closed center position. When a port is blocked and the valve is shifted to the blocked port, the pump will generated excessive heat. An electric or rotary air pump can either be turned off manually or with a pressure switch. Reciprocating air pumps may be adjusted to stall out and stop.

NOTE:Gauge ports monitor pump pressure only, not pressure to the hydraulic cylinder(s).

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required.For valves 9502 and 9520, order four 12001 cap screws.For valve 9576, order four 17428 cap screws.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs)
9502 S.A. Manual 3-way, 3 Pos. Closed Ctr. No Yes Yes 4.2
* “S.A.” represents single-acting cylinders

View Complete Details

Pump Mounted Manual Valve

4-WAY/3-POSITION (CLOSED CENTER) MANUAL VALVEApplication Single or double-acting cylinders.

Actuation Lever operated, detent positioned.

FunctionsAdvance, hold and return. Closed center design makes valve suitable for operating multiple cylinders from a single pump.

Used on these pumps P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and P120 series.

10, 000 PSI., 3/8" PORTS, 5 GPM MAX FLOW RATE.

NOTE:APressure Switchand/or Gauge (AnalogorDigital) may be attached to valves 9500, 9501, 9506, 9511 if desired.

NOTE:Also, valves may be remote mounted with a9510 Subplates.

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9501 S.A & D.A. Manual 4-way, 3 Pos. Closed Center No Yes No 4.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders

View Complete Details

Relief Valve

Application:Provide an economical means of protecting an hydraulic circuit against over pressurization.

Operation:These factory preset valves are designed for maximum flow rate of 5 gpm. Furnished with 1/8" NPTF male port. All valves weigh 0.2 lb. See chart in 'Specifications'for ordering information.

NOTE: Care should be exercised to protect workers from hot, pressurized hydraulic oil. Install these valves only in an enclosed or shielded area.

Order No. Pressure Setting 
(psi)
Weight (lbs)   Order No. Pressure Setting 
(psi)
Weight (lbs)
RV21278 10,100 / 10,700 0.2 RV21278-50 5,100 / 5,700 0.2
RV21278-6 600 /640 0.2 RV21278-52 5,300 / 5,900 0.2
RV21278-10 900 / 1,000 0.2 RV21278-55 5,600 / 6,200 0.2
RV21278-15 1,500 / 1,700 0.2 RV21278-57 5,800 / 6,400 0.2
RV21278-17 1,600 / 1,800 0.2 RV21278-60 6,100 / 6,700 0.2
RV21278-20 1,900 / 2,200 0.2 RV21278-65 6,600 / 7,200 0.2
RV21278-25 2,300 / 2,700 0.2 RV21278-70 7,100 / 7,700 0.2
RV21278-27 2,600 / 2,800 0.2 RV21278-75 7,600 / 8,200 0.2
RV21278-28 2,700 / 3,000 0.2 RV21278-80 8,100 / 8,700 0.2
RV21278-30 3,000 / 3,400 0.2 RV21278-83 8,400 / 9,000 0.2
RV21278-32 3,100 / 3,300 0.2 RV21278-86 8,700 / 9,300 0.2
RV21278-35 3,500 / 3,800 0.2 RV21278-88 8,900 / 9,600 0.2
RV21278-38 3,750 / 3,950 0.2 RV21278-90 9,100 / 9,700 0.2
RV21278-40 4,100 / 4,500 0.2 RV21278-114 11,500 / 12,100 0.2
RV21278-43 4,400 / 4,800 0.2 RV21278-6280 6,380 / 6,900 0.2
RV21278-48 4,900 / 5,300 0.2 Preset — Non-Serviceable


View Complete Details

Auto-Pilot Operated Valves

Application Single-acting cylinders.

Actuation- Pilot oil.

Functions When pump is started, pilot oil automatically closes valve and directs oil to cylinder; when pump is stopped, valve automatically opens and oil returns to reservoir.

Used on these pumps Furnished with pilot lines and adapters for PA55, PA90, PE30, PE55, PE90, and PE120 series.

NOTE:A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required. For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.For valve 9582, order two 12001 and two 10856 cap screws.


Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9610 S.A. Auto Pilot Operated 3-way, 2 Pos. Yes No No 4.2
* “S.A.” represents single-acting cylinders

View Complete Details

Metering Valve

Application:For systems using large cylinders or extended lengths of hydraulic hose.

Operation:Controls surges by restricting flow if it exceeds 7 gpm. When flow subsides, valve reopens automatically. Has 3/8" NPTF male end to thread into return port of system control valve, and a 3/8" NPTF female end, permitting return hose to be directly connected.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9631 S.A. & D.A. Automatic Metering Valve 0.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders
 


View Complete Details

Sequence Valve

Application:Used when one cylinder in a multi-cylinder application must advance before any other.

Operation:Pump is connected to port P and separate cylinders to ports A and B. When pressure is applied to port P, cylinder A advances. Cylinder B will not advance until a predetermined pressure setting is reached in cylinder A. Pressure setting is adjustable from 500 to 8, 000 psi with adjustment screw; factory preset at 1, 000 psi. Has 3/8" NPTF ports.

 

 

 
Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs)
9597 S.A. & D.A. Automatic Sequence Valve 5.6
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders
 
 

 

   
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Rounak Chindalia (Chindalia Industrial Products Limited)
  • C-23, Punit Industrial Premises Co-op Society Limited Plot 11a-11d, Midc, Ttc Area, Thane Belapur Road, Turbhe, Navi Mumbai - 400 705., Maharashtra - 400053
  • Share us via
  • Call 08068051324 Ext. 065
Retailer of Valves & Valve Fittings from Mumbai, Maharashtra by Chindalia Industrial Products Limited
Post Buy Requirement
CI

Chindalia Industrial Products Limited Mumbai, Maharashtra

Mumbai, Maharashtra, India
Verified Add Review

Our Product / Services

  1. Industrial Jacks, Lifts & Winches 9 Products available
  2. Industrial Valves 9 Products available
  3. Pumps, Pumping Machines & Parts 8 Products / Services available
  4. Valves & Valve Fittings 8 Products available
  5. Hand Tool 5 Products available
  6. Boom Lifts 3 Products available
  7. Adapter 3 Products available
  8. Hydraulic Press 3 Products available
  9. Industrial Pump 3 Products available
  10. Hydraulic And Pneumatic Machines 3 Products available
  11. Others Products / Services 109 Products / Services available

Valves & Valve Fittings #1259138

We offer a complete product range of 2-position Manual Valves, Non-Interflow Manual valves, Pump Mounted Manual Valve, Relief Valve and Auto-Pilot Operated valves

2-position Manual Valves

Application Single or double-acting cylinders.

Actuation Lever operated, detent positioned.

Functions Pos. 1 Oil is directed to advance side of cylinder, oil from retract side goes to reservoir; cylinder holds with pump shut off. Pos. 2 Oil goes to retract side of cylinder; cylinder holds with pump shut off. When using as a 3-way valve for single-acting cylinders, port A or B is plugged.

Used on these pumps P460, PA6D, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.

NOTE:9504 can be remote mounted with a 9510 Subplates.

NOTE:A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required.
For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.
For valve 9582, order two 12001 and two 10856 cap screws.

NOTE:Valves 9501, 9502, 9504 and 9507 can have a port blocked or have a closed center position. When a port is blocked and the valve is shifted to the blocked port, the pump will generate excessive heat. An electric or rotary air pump can either be turned off manually or with a pressure switch. Reciprocating air pumps may be adjusted to stall out and stop.

NOTE:Gauge ports monitor pump pressure only, not pressure to the hydraulic cylinder(s).

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9504 S.A. & D.A. Manual 3/4-way, 2 Pos. Yes Yes No 4.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders

View Complete Details

Non-Interflow Manual Valves

3-WAY/3-POSITION (CLOSED CENTER) NON-INTERFLOW MANUAL VALVE WITH POSI-CHECK

Application Single-acting cylinders.

Actuation Lever operated, detent positioned.

Functions Pos. 1 Oil is directed from pump to cylinder and holds with pump shut off; line to reservoir is blocked. Pos. 2 All oil is open to reservoir through tank line.

Center pos. Cylinder pressure is held; pump should be shut off.

Used on these pumps P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.

10, 000 PSI., 3/8" PORTS, 5 GPM MAX FLOW RATE.

NOTE:APressure Switchand/or Gauge (AnalogorDigital) may be attachedif desired.

NOTE:Also, valve may be remote mounted with a9510 Subplates.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use aLoad Lowering Valve (No. 9596)orCounter Balance Valve (No. 9720)in conjunction with the directional valve used in your application.

NOTE:Valves 9501, 9502, 9504 and 9507 can have a port blocked or have a closed center position. When a port is blocked and the valve is shifted to the blocked port, the pump will generated excessive heat. An electric or rotary air pump can either be turned off manually or with a pressure switch. Reciprocating air pumps may be adjusted to stall out and stop.

NOTE:Gauge ports monitor pump pressure only, not pressure to the hydraulic cylinder(s).

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required.For valves 9502 and 9520, order four 12001 cap screws.For valve 9576, order four 17428 cap screws.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs)
9502 S.A. Manual 3-way, 3 Pos. Closed Ctr. No Yes Yes 4.2
* “S.A.” represents single-acting cylinders

View Complete Details

Pump Mounted Manual Valve

4-WAY/3-POSITION (CLOSED CENTER) MANUAL VALVEApplication Single or double-acting cylinders.

Actuation Lever operated, detent positioned.

FunctionsAdvance, hold and return. Closed center design makes valve suitable for operating multiple cylinders from a single pump.

Used on these pumps P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and P120 series.

10, 000 PSI., 3/8" PORTS, 5 GPM MAX FLOW RATE.

NOTE:APressure Switchand/or Gauge (AnalogorDigital) may be attached to valves 9500, 9501, 9506, 9511 if desired.

NOTE:Also, valves may be remote mounted with a9510 Subplates.

IMPORTANT:Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9501 S.A & D.A. Manual 4-way, 3 Pos. Closed Center No Yes No 4.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders

View Complete Details

Relief Valve

Application:Provide an economical means of protecting an hydraulic circuit against over pressurization.

Operation:These factory preset valves are designed for maximum flow rate of 5 gpm. Furnished with 1/8" NPTF male port. All valves weigh 0.2 lb. See chart in 'Specifications'for ordering information.

NOTE: Care should be exercised to protect workers from hot, pressurized hydraulic oil. Install these valves only in an enclosed or shielded area.

Order No. Pressure Setting 
(psi)
Weight (lbs)   Order No. Pressure Setting 
(psi)
Weight (lbs)
RV21278 10,100 / 10,700 0.2 RV21278-50 5,100 / 5,700 0.2
RV21278-6 600 /640 0.2 RV21278-52 5,300 / 5,900 0.2
RV21278-10 900 / 1,000 0.2 RV21278-55 5,600 / 6,200 0.2
RV21278-15 1,500 / 1,700 0.2 RV21278-57 5,800 / 6,400 0.2
RV21278-17 1,600 / 1,800 0.2 RV21278-60 6,100 / 6,700 0.2
RV21278-20 1,900 / 2,200 0.2 RV21278-65 6,600 / 7,200 0.2
RV21278-25 2,300 / 2,700 0.2 RV21278-70 7,100 / 7,700 0.2
RV21278-27 2,600 / 2,800 0.2 RV21278-75 7,600 / 8,200 0.2
RV21278-28 2,700 / 3,000 0.2 RV21278-80 8,100 / 8,700 0.2
RV21278-30 3,000 / 3,400 0.2 RV21278-83 8,400 / 9,000 0.2
RV21278-32 3,100 / 3,300 0.2 RV21278-86 8,700 / 9,300 0.2
RV21278-35 3,500 / 3,800 0.2 RV21278-88 8,900 / 9,600 0.2
RV21278-38 3,750 / 3,950 0.2 RV21278-90 9,100 / 9,700 0.2
RV21278-40 4,100 / 4,500 0.2 RV21278-114 11,500 / 12,100 0.2
RV21278-43 4,400 / 4,800 0.2 RV21278-6280 6,380 / 6,900 0.2
RV21278-48 4,900 / 5,300 0.2 Preset — Non-Serviceable


View Complete Details

Auto-Pilot Operated Valves

Application Single-acting cylinders.

Actuation- Pilot oil.

Functions When pump is started, pilot oil automatically closes valve and directs oil to cylinder; when pump is stopped, valve automatically opens and oil returns to reservoir.

Used on these pumps Furnished with pilot lines and adapters for PA55, PA90, PE30, PE55, PE90, and PE120 series.

NOTE:A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.

CAUTION:To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.

IMPORTANT:When ordering any valve for a PE30 or PG30 series pump, longer mounting screws are required. For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.For valve 9582, order two 12001 and two 10856 cap screws.


Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9610 S.A. Auto Pilot Operated 3-way, 2 Pos. Yes No No 4.2
* “S.A.” represents single-acting cylinders

View Complete Details

Metering Valve

Application:For systems using large cylinders or extended lengths of hydraulic hose.

Operation:Controls surges by restricting flow if it exceeds 7 gpm. When flow subsides, valve reopens automatically. Has 3/8" NPTF male end to thread into return port of system control valve, and a 3/8" NPTF female end, permitting return hose to be directly connected.

Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs.)
9631 S.A. & D.A. Automatic Metering Valve 0.2
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders
 


View Complete Details

Sequence Valve

Application:Used when one cylinder in a multi-cylinder application must advance before any other.

Operation:Pump is connected to port P and separate cylinders to ports A and B. When pressure is applied to port P, cylinder A advances. Cylinder B will not advance until a predetermined pressure setting is reached in cylinder A. Pressure setting is adjustable from 500 to 8, 000 psi with adjustment screw; factory preset at 1, 000 psi. Has 3/8" NPTF ports.

 

 

 
Order No. Cylinder 
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs)
9597 S.A. & D.A. Automatic Sequence Valve 5.6
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders
 
 

 

   
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Rounak Chindalia (Chindalia Industrial Products Limited)
  • C-23, Punit Industrial Premises Co-op Society Limited Plot 11a-11d, Midc, Ttc Area, Thane Belapur Road, Turbhe, Navi Mumbai - 400 705., Maharashtra - 400053
  • Share us via
  • Call 08068051324 Ext. 065