Post Buy Requirement
CI
Thane, Maharashtra, India
Verified Add Review

Measuring Instruments & Equipment #5248681

Oval Gear Flow Meter

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Crude Oil Positive Displacement Flow Meter

  • Output PULSE (from Sensor ) / 4-20mA / RS 485 Modbus (Optional )
  • Display 5 Digit LCD Flow Rate Indicator / 8 Digit Totaliser
  • Enclosure Flameproof IIA IIB CMRI certified
  • Mounting Integral
View Complete Details

Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY Size 220 X 120 X 85 mm with glass window.
  • FLOW UNIT PG-9 / PG-11
  • EMPTY PIPEDETECTION Selectable.
  • LOW CUTTOFF   
  • Output Available
  • COMMUNICATION 4 – 20 Ma
  • DIRECTION RS 485 MODBUS
  • PROGRAMMING Suitable for Bi- Directional
  • TERMINALS Through Key/ Keypad on front facia.
  • SIGNAL CONVERTOR Shock – Hazard – Protected screwless terminals.
  • INTERCHANGE ABILITY :Fully interchangeable with all sizes of flow sensors. Integral / Remote (with 3 meterCable)
  • POWERFAILURE MODE  Provision of RAM/PROM to store parameter entered and measured flow dataduring power failure
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
View Complete Details

Diesel Oil Flow Meter

  • Body Aluminum anodize/S.S-304/S.S-316
  • Enclosure Explosionproof
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Diesel Flow Meter

  • Accuracy +/-1%
  • Weight 3 kg
  • End Connections 1-1.5 inch
  • Max Flow Rate 40 GPM
  • Temperature 80 deg C
View Complete Details

ELECTROMAGNETIC FLOW METER FOR DAIRY

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Sanitary Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION UNION TRICLOVER TYPE FITTING
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring power failure
View Complete Details

VORTEX FLOW METER FOR STEAM

  • Medium gas, liquid, vapor
  • .Accuracy Liquid Gas 1% Steam 1.5%
  • Temperature -20oC to +350oC
  • Measure Liquid Gas Steam
  • inside nominal diameter (mm) 25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, (300~1000 plug-in)
  • nominal pressure (MPa) DN25-DN200 4.0(>4.0 order by agreement), DN250-DN300 1.6(>1.6 order by agreement)
  • medium temperature (°C) piezoelectric type:-40~260, -40~320;capacitance: -40~300,  -40~400, -40~450(order by agreement)
  • noumenon 1Cr18Ni9Ti, (order by agreement if need other material)
  • vibrating acceleration piezoelectric type:0.2g     capacitance:1.0~2.0g
  • range ±1%R, ±1.5%R, ±1FS;plug-in:±2.5%R, ±2.5%FS
  • Range degree 1:6~1:30
  • service voltage sensor:+12V DC, +24V DC;transmitter:+12V DC , +24V DC;battery supply feed:3.6V battery
  • output signal square wave pulse (non- battery supply feed):high level≥5V, low level≤1V;current:4~20mA
  • loss coefficient JB/T9249 Cd≤2.4
  • anti-explosion sign Ben-an type:ExdⅡia CT2-T5 anti-explosion type:ExdⅡCT2-T5      
  • Protection grade ordinary type IP65     dive type IP68
  • environment condition Tem-20°C~55°C, relative humidity 5%~90%, atm press 86~106kPa
  • transmission range three-wire system flow sensor:≤300m, electric sign of two-wire system transmitter (4~20mA):load resistance≤750Ω
View Complete Details

Water Flow Meter

  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • ACCURACY +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • REPEATABILITY +/- 0.2% F.S
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • OUTPUT 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Low Cost Battery Operated Electromagnetic Flow Meter

Specifications

Low Cost Battery Operated Electromagnetic Flow Meter (ISO 9001)1. Battery powered2. High Accuracy3. RS 485 / GPRS System

Low Cost Battery Operated Electromagnetic Flow Meter (ISO 9001)

Applications :
1. Effluent Treatement Plants.
2. Sewage Treatement Plants.
3. Water Supply Schemes.
4. Steel & Aluminium.
5. Pulp & Paper.
6. Chemical & Fertilizers.
7. Food & Drug.
8. Pumps & Valve Calibration Lab.
9. Dairy Industry.
10. Corrosive Liquids.
11. Sugar Industry.

Features:

  1. No pressure loss. No moving parts.
  2. High accuracy of 0.2%.
  3. Wide size range of 103000mm, adapt to different size of pipeline.
  4. Two-line LCD, able to displaypositive and negative instantaneous flow and accumulative flow.
  5. Measurement is not affected by the density, viscosity, temperature, pressure and electroconductibility of fluid;
  6. Multiple choices are available for the liner of converter and the material of electrode;
  7. Pulse and 4-20mAstandard current output. Multiple choices of communications:RS232, RS485, HART, Modbus, Profibus, etc.
  8. Explosion-proof type can be used at relevant explosion-proof sites. IP68 remote type can be used underwater.
  9. Variable forms for different kinds of working conditions.Compact and remote form; flanged, flanged wafer, clamped, threaded, insertion end connection; DC/AC, battery power supply.

Item

Compact type

Remote type

 

Flange connection

Inserted type

Threaded connection

Flange connection

Inserted type

Threaded connection

Caliber(mm)

15~3000

125~3000

10~25

15~3000

125~3000

10~25

Pressure(MPa)

0.6,1.0,1.6,4.0

Accuracy

±0.5%, ±0.3%(±0.2% available for special order)

Applicable medium

Conductive liquid and slurry

Medium Temperature

≤150°C

Medium Conductivity

≥5μS/cm

Medium Velocity

≤15 m/s

Ambient

Temperature:-25°C~+60°C, Humidity: 5%~90%

Liner Material

DN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane;
DN40mm~1000mm: F4, Polyurethane, Polychloropree rubber;
DN1000mm~3000mm: Polychloropree rubber;
Others: Polyvinyl fluoride, Fluorinated ethylene-propylene(FEP), etc.

Electrode Material

Mo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide

Electrode Type

Fixed type(DN150~DN2600); Blade type(DN300~DN1600)

Flange Material

SS, CS

Communication

RS485, RS232, HART, Modbus, Profibus-DP

Signal Output

Analog 4-20mA, pulse, isolated, load resistor≤750Ω

Power Supply

AC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V; lithium battery(3.6V)

AC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V

Display

LCD display with back light.

Intelligent flow totalizer display.

Protection Grade

IP65

IP65, IP67, IP68

Explosion-
proof Grade

ExdmⅡCT4, mdⅡBT4

non







View Complete Details

Furnace Oil Flow Meter

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Gas Flow Meter

  • 1. Service Bio-Gas, Compressed Air, Compressed Gas, LPG, Steam.
  • 2. Size ½” to 14”
  • 3. Type of Flow meter Differential Pressure Type.
  • 4. Flow Element Orifice / Integral Orifice / Nozzle
  • 5. MOC of Flow Element SS 316
  • 6. Density Compensation Can be provided.
  • 7. Type of Flanges WNRF (Weld Neck Raised Face)
  • 8. MOC of Flange C.S / S.S / P.P.
  • 9. Flange Rating ANSI 150 / ANSI 300 / ANSI 600
  • 10. Type Of Taps Flanged Tapping / Corner Tapping / D & D/2
  • 11. No. Of DP Tappings 1 Pair
  • 12. No. Of Drain Tappings 1 Pair
  • 13. Design Standard BS - 1042 / ISO
  • 14. Accuracy ± 1% of actual reading (Flowmeter)
View Complete Details

Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Insertion Type Electromagnetic Flow Meter

  • Accuracy +/-0.03 m/Sec +/- 1% of velocity
  • Medium Conductivity >5 uS/cm
  • Pipe Sizes >200 mm < 3 mtrs
  • Probe material SS 304
  • Electrodes SS 316L
  • Sensor Material Epoxy
  • Flow Velocity Ranges 0.1 to 10 m/s in two ranges ( 0 to 5 m/sec & 0 to 10 m/sec)
  • Pressure Rating 10 bar Standard , Higher pressure ratings on request
  • Operating Temperature Medium 0 to 60 Deg.C
  • Pressure Rating………………… 10 Bar at 55ºC (20 Bar optional)
  • Operating Temperature Ambient 0 to 55 Deg. C for Converter
View Complete Details

Oval Gear Flow Sensor

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Measuring Instruments & Equipment from Thane, Maharashtra by Cbro Incorporation
Post Buy Requirement
CI

Cbro Incorporation Thane, Maharashtra

Thane, Maharashtra, India
Verified Add Review

Measuring Instruments & Equipment #5248681

Our Complete range of products are Oval Gear Flow Meter, crude oil positive displacement flow meter, Electromagnetic Flow Meter, Diesel Oil Flow Meter and Diesel Flow Meter.

Oval Gear Flow Meter

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Crude Oil Positive Displacement Flow Meter

  • Output PULSE (from Sensor ) / 4-20mA / RS 485 Modbus (Optional )
  • Display 5 Digit LCD Flow Rate Indicator / 8 Digit Totaliser
  • Enclosure Flameproof IIA IIB CMRI certified
  • Mounting Integral
View Complete Details

Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY Size 220 X 120 X 85 mm with glass window.
  • FLOW UNIT PG-9 / PG-11
  • EMPTY PIPEDETECTION Selectable.
  • LOW CUTTOFF   
  • Output Available
  • COMMUNICATION 4 – 20 Ma
  • DIRECTION RS 485 MODBUS
  • PROGRAMMING Suitable for Bi- Directional
  • TERMINALS Through Key/ Keypad on front facia.
  • SIGNAL CONVERTOR Shock – Hazard – Protected screwless terminals.
  • INTERCHANGE ABILITY :Fully interchangeable with all sizes of flow sensors. Integral / Remote (with 3 meterCable)
  • POWERFAILURE MODE  Provision of RAM/PROM to store parameter entered and measured flow dataduring power failure
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
View Complete Details

Diesel Oil Flow Meter

  • Body Aluminum anodize/S.S-304/S.S-316
  • Enclosure Explosionproof
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Diesel Flow Meter

  • Accuracy +/-1%
  • Weight 3 kg
  • End Connections 1-1.5 inch
  • Max Flow Rate 40 GPM
  • Temperature 80 deg C
View Complete Details

ELECTROMAGNETIC FLOW METER FOR DAIRY

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Sanitary Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION UNION TRICLOVER TYPE FITTING
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring power failure
View Complete Details

VORTEX FLOW METER FOR STEAM

  • Medium gas, liquid, vapor
  • .Accuracy Liquid Gas 1% Steam 1.5%
  • Temperature -20oC to +350oC
  • Measure Liquid Gas Steam
  • inside nominal diameter (mm) 25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, (300~1000 plug-in)
  • nominal pressure (MPa) DN25-DN200 4.0(>4.0 order by agreement), DN250-DN300 1.6(>1.6 order by agreement)
  • medium temperature (°C) piezoelectric type:-40~260, -40~320;capacitance: -40~300,  -40~400, -40~450(order by agreement)
  • noumenon 1Cr18Ni9Ti, (order by agreement if need other material)
  • vibrating acceleration piezoelectric type:0.2g     capacitance:1.0~2.0g
  • range ±1%R, ±1.5%R, ±1FS;plug-in:±2.5%R, ±2.5%FS
  • Range degree 1:6~1:30
  • service voltage sensor:+12V DC, +24V DC;transmitter:+12V DC , +24V DC;battery supply feed:3.6V battery
  • output signal square wave pulse (non- battery supply feed):high level≥5V, low level≤1V;current:4~20mA
  • loss coefficient JB/T9249 Cd≤2.4
  • anti-explosion sign Ben-an type:ExdⅡia CT2-T5 anti-explosion type:ExdⅡCT2-T5      
  • Protection grade ordinary type IP65     dive type IP68
  • environment condition Tem-20°C~55°C, relative humidity 5%~90%, atm press 86~106kPa
  • transmission range three-wire system flow sensor:≤300m, electric sign of two-wire system transmitter (4~20mA):load resistance≤750Ω
View Complete Details

Water Flow Meter

  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • ACCURACY +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • REPEATABILITY +/- 0.2% F.S
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • OUTPUT 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Low Cost Battery Operated Electromagnetic Flow Meter

Specifications

Low Cost Battery Operated Electromagnetic Flow Meter (ISO 9001)1. Battery powered2. High Accuracy3. RS 485 / GPRS System

Low Cost Battery Operated Electromagnetic Flow Meter (ISO 9001)

Applications :
1. Effluent Treatement Plants.
2. Sewage Treatement Plants.
3. Water Supply Schemes.
4. Steel & Aluminium.
5. Pulp & Paper.
6. Chemical & Fertilizers.
7. Food & Drug.
8. Pumps & Valve Calibration Lab.
9. Dairy Industry.
10. Corrosive Liquids.
11. Sugar Industry.

Features:

  1. No pressure loss. No moving parts.
  2. High accuracy of 0.2%.
  3. Wide size range of 103000mm, adapt to different size of pipeline.
  4. Two-line LCD, able to displaypositive and negative instantaneous flow and accumulative flow.
  5. Measurement is not affected by the density, viscosity, temperature, pressure and electroconductibility of fluid;
  6. Multiple choices are available for the liner of converter and the material of electrode;
  7. Pulse and 4-20mAstandard current output. Multiple choices of communications:RS232, RS485, HART, Modbus, Profibus, etc.
  8. Explosion-proof type can be used at relevant explosion-proof sites. IP68 remote type can be used underwater.
  9. Variable forms for different kinds of working conditions.Compact and remote form; flanged, flanged wafer, clamped, threaded, insertion end connection; DC/AC, battery power supply.

Item

Compact type

Remote type

 

Flange connection

Inserted type

Threaded connection

Flange connection

Inserted type

Threaded connection

Caliber(mm)

15~3000

125~3000

10~25

15~3000

125~3000

10~25

Pressure(MPa)

0.6,1.0,1.6,4.0

Accuracy

±0.5%, ±0.3%(±0.2% available for special order)

Applicable medium

Conductive liquid and slurry

Medium Temperature

≤150°C

Medium Conductivity

≥5μS/cm

Medium Velocity

≤15 m/s

Ambient

Temperature:-25°C~+60°C, Humidity: 5%~90%

Liner Material

DN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane;
DN40mm~1000mm: F4, Polyurethane, Polychloropree rubber;
DN1000mm~3000mm: Polychloropree rubber;
Others: Polyvinyl fluoride, Fluorinated ethylene-propylene(FEP), etc.

Electrode Material

Mo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide

Electrode Type

Fixed type(DN150~DN2600); Blade type(DN300~DN1600)

Flange Material

SS, CS

Communication

RS485, RS232, HART, Modbus, Profibus-DP

Signal Output

Analog 4-20mA, pulse, isolated, load resistor≤750Ω

Power Supply

AC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V; lithium battery(3.6V)

AC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V

Display

LCD display with back light.

Intelligent flow totalizer display.

Protection Grade

IP65

IP65, IP67, IP68

Explosion-
proof Grade

ExdmⅡCT4, mdⅡBT4

non







View Complete Details

Furnace Oil Flow Meter

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details

Gas Flow Meter

  • 1. Service Bio-Gas, Compressed Air, Compressed Gas, LPG, Steam.
  • 2. Size ½” to 14”
  • 3. Type of Flow meter Differential Pressure Type.
  • 4. Flow Element Orifice / Integral Orifice / Nozzle
  • 5. MOC of Flow Element SS 316
  • 6. Density Compensation Can be provided.
  • 7. Type of Flanges WNRF (Weld Neck Raised Face)
  • 8. MOC of Flange C.S / S.S / P.P.
  • 9. Flange Rating ANSI 150 / ANSI 300 / ANSI 600
  • 10. Type Of Taps Flanged Tapping / Corner Tapping / D & D/2
  • 11. No. Of DP Tappings 1 Pair
  • 12. No. Of Drain Tappings 1 Pair
  • 13. Design Standard BS - 1042 / ISO
  • 14. Accuracy ± 1% of actual reading (Flowmeter)
View Complete Details

Electromagnetic Flow Meter

  • Accuracy +/-0.5% of Actual Flow Rate (+/- 0.3%, +/-0.2% on request)
  • Repeatability +/- 0.2% F.S
  • CERTIFICATIN CE CERTIFIED
  • METERINGTUBE S.S 304
  • ELECTRODE S.S 316
  • FLANGE C.S.
  • LINING PTFE
  • END CONNECTION ASA150#Flanged as per B 16.5.
  • MOUNTING Inline
  • MIN CONDUCTIVITY 10 uS/cm
  • MAX PROCESS TEMP. 0-60 deg C Normally ( Higher Temperature Available)
  • PRESSURERATING 10 Bar ( Higher Pressuer Available)
  • MAINSPOWER 230 V AC 50Hz / 24 V DC
  • ENCLOSURE M.O.C. Cast Aluminum IP65Signal Amplifier Box
  • CABLE ENTRY PG-9 / PG-11
  • FLOW UNIT Selectable.
  • EMPTY PIPEDETECTION Available
  • LOW CUTTOFF Available
  • Output 4 – 20 Ma
  • COMMUNICATION RS 485 MODBUS
  • DIRECTION Suitable for Bi- Directional
  • PROGRAMMING Through Key/ Keypad on front facia.
  • TERMINALS Shock – Hazard – Protected screwless terminals.
  • SIGNAL CONVERTOR Integral / Remote (with 3 meterCable)
  • INTERCHANGE ABILITY Fully interchangeable with all sizes of flow sensors.
  • POWERFAILURE MODE Provision of RAM/PROM to store parameter entered and measured flow dataduring
View Complete Details

Insertion Type Electromagnetic Flow Meter

  • Accuracy +/-0.03 m/Sec +/- 1% of velocity
  • Medium Conductivity >5 uS/cm
  • Pipe Sizes >200 mm < 3 mtrs
  • Probe material SS 304
  • Electrodes SS 316L
  • Sensor Material Epoxy
  • Flow Velocity Ranges 0.1 to 10 m/s in two ranges ( 0 to 5 m/sec & 0 to 10 m/sec)
  • Pressure Rating 10 bar Standard , Higher pressure ratings on request
  • Operating Temperature Medium 0 to 60 Deg.C
  • Pressure Rating………………… 10 Bar at 55ºC (20 Bar optional)
  • Operating Temperature Ambient 0 to 55 Deg. C for Converter
View Complete Details

Oval Gear Flow Sensor

  • Enclosure Aluminum anodize/S.S-304/S.S-316
  • Rotor Aluminum anodize/S.S-316/PPS
  • O-ring NBR/Viton
  • Shaft Hard Stainless Steel-316
  • Accuracy (standard installation position) +/- 0.5% ( Higher on request)
  • Maximum working pressure 10MPa
  • Fluid &Ambient temperature -40 to80 Deg
  • Power voltage 5 - 24V DC
  • Connection Threaded M/F / Flange
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us