Our Products
Cosmetics, Hair Care & Beauty Products
2 Products availableDisinfectant For Dental Suction System
1 Products availableHand Wash
1 Products availableHand Sanitizer
1 Products availableFloor Cleaner
1 Products availableWe offer the best product range of Bibforte Disinfectant, Desnet Plus Disinfectant, Desnet Surface & Environment Disinfectant and Minuten Spray Surface & Instrument Disinfectant.
Composition: 100 gram BIB forte contains: 2.2gm Dodecyldipropylenetriamine, 1.7gm Trialkylthoxyammonium, tensides and auxiliaries
Application concentrations & Efficacy : Bactericidal (incl. TBC, . MRSA), yeasticidal acc. to EN: efficient incl. limited spectrum 0.5 % - 60 minutes of virucidal activity according to 2.0 % - 30 minutes prEN 16777 quick incl. virucidal according to 3.0 % - 10 minutes EN 14476 (55 C) against (in ultrasonic device) non-enveloped viruses incl. 4.0 % - 5 minutes polio-and parvo as well as (in ultrasonic device) all enveloped viruses efficient incl. virucidal according 0.5 % - 60 minutes to prEN 16777 after the 1.0 % - 10 minutes pre-cleaning with AlproZyme (incl. parvo-viruses)
Virus-inactivating : Enveloped viruses HCV / BVDV 1% 5 min. Herpes simplex. Influenza (incl. H1N1, H5N1) 1% 5 min. HBV, HIV 1% 15 min. 2% 5 min. Vaccinia 1 % 15 min. No-enveloped Polio viruses : 4% 5 min. at 55C (e.g. in ultrasonic device)
Features :
Instrument compatibility: Approved and recommended by Olympus, Pentex, Fuginon. Karl Storz, Sass wolf endoscopes (Rigid & Flexible), Dental rotary precision instruments as e.g. steel and hard diamond drills. surgery drills and carbide burs, crown cutters, root canal instrument, rubber burnishes, arkansas stones, tweezers ultrasonic bath compatible and compatible to surgical instruments, plastic instruments, General surgical and medical instruments (diagnostic, preserving and surgical instruments e.g. extracting forceps, root elevators, dental mirrors,
Direction to use: Open the measuring cup lid of BIB forte bottle. Press the bottle keeping in upright direction to receive the required quantity in the cup and pour it in a container containing required amount of potable water and then dip in it the clean and dry instruments. endoscopes to be disinfected. After completion of holding period take out the instruments, endoscope and rinse it with filtered water for at least three intervals of one minute each. Dry the instrument and use.
Disinfection is effected by number of microbes and quantity of organic matter deposited on the article
Step 1 (Cleaning): Contaminated instruments must be thoroughly cleaned prior to disinfection to reduce the number of organisms and remove organic matter. Rinse the surface and lumen of the instrument thoroughly with large amount of fresh water. Note: Always refer to manufacturers instruction about cleaning, decontamination and disassembly of instrument .
Step 2 (Disinfection): Immerse clean and dry instrument completely in 5% Bib forte solution (50 ml of Bib forte+ 1000 ml of filter water). Don't forget to fill the lumen of instrument if applicable and ensure complete submersion of instrument in Bib forte. Wait for 30 minutes.
Step 3 (Rinsing): Following disinfection the instrument is rinsed thoroughly to remove any residual disinfectant. The lumen of the instrument should be flushed at least three times of one minute duration with large volumes of sterile/filtered water.
Cleaning Action
Action spectrum | Concentration | Contact time |
---|---|---|
Bactericidal, Fungicidal, Virucidal (HIV/HBV/HCV), Tuberculocidal | 5% | 30 min |
Emergency disinfection/In Ultrasonic Device | 10% | 5 min |
Terminal disinfection | 10%/5% | 5 hrs/10 hrs |
Procedure To Prepare Standard Working Dilution (5%)
Req. Sol | BIB Forte | Potable Water |
---|---|---|
1L | 50ml | 950ml |
2L | 100ml | 1.90L |
5L | 100ml | 4.75L |
10 L | 500 ml | 9.50 L |
Composition: 100gram contains: 7.0gm Didecyldimethylammoniumchloride 5.0gm Potassium carbonate, Tensides and auxiliaries.
Better
Area of Use: All High-risk Areas, Operation theaters and ICUs, Burn Units, Blood Banks, Clinical Laboratories and Dental Clinics
Application Fogging: Take 08m1 with 400m1 of water to make working solution, sufficient for 1000 cu.ft. for area like OT, ICU and ICCU wards. To achieve maximum effect close doors, windows fans & ACs during process of fogging. After switching off the fogger wait for 30 min as holding period.
Better Coverage
Features :
Other Information :
DesNet Fogging 'Area' Vs 'Solution' Vs 'Time'
Area | Solution | Fogging Time |
---|---|---|
1000 Ft | DesNet 20 ml + 980 ml water | 15 mins |
2000 Ft | DesNet 40 ml + 1960 ml water | 25 mins. |
3000 Ft | DesNet 80 ml + 2920 ml water | 40 mins. |
DesNet Cost Effective
Formulation used | Solution | No of surgeries lost | Financial loss | Toxicity |
---|---|---|---|---|
DesNet | 60 minutes | Nil | Nil | Non Toxic |
Formaldehyde + KMnO4+Ammonia |
24 hours (requrie sealing of room) |
6-12 | Maximum | Known Carcinogenic |
Formaldehyde + Gluteraldehyde |
4-6 hours (require sealing of room |
3-4 | Medium | Known Carcinogenic & Skin, Eye Irritant |
Composition: 100gram contains: Ethanol I.P. 45gm. Iso-propyl alcohol l.P. 15gm, Dialkyldimethylammonium chloride 0.08gm, Alkylamine derivatives 0.05gm, Chlorhexidine gluconate solution I.P.0.10gm
Aldehyde & Phenol Free QuickActing disinfectant ready for use for surfaces of medical devices such as hand pieces & contra-angles, unit grips and suspension tables, contains active cleaning ingredients, Medical Equipment & Noncritical Environmental Surfaces disinfection is a daily routine, which ensures safety. These are close to the patient & is frequently touched by the patient or staff which could result in patient exposures & also contribute to cross-contamination (e.g., Bedrails. Bedside tables tablet. Carts, Door-Knobs, Bedpans. Crutches Computers, Surgical Tables, Ventilators, Warmers, Infant Care Units). Approved & recommended by Sirona Dental.
Efficacy: Bactericidal incl. TBC and MRSA Fungicidal Virus-inactivating: enveloped viruses incl. HBV, HCV. HIV, Herpes simplex, Influenza (incl. H1N1, H5N1) BVDV Vaccinia as well as non-enveloped Adeno viruses With remanence effect (reduction of recontamination) Certified by VAH/DGHM, Germany. meets the DGHM requirements and EN-standards for surface disinfection Biodegradable (As per OECD regulations)
Application: Spray on the surface from a distance of 30 cms completely moisten surfaces & objects that have to be disinfected & let the disinfectant take effect according to the spectrum of activity. Wait for 2 minutes or till the surface dries up. Clean the instrument or surface with a clean dry wipe/strife cloth. Only for use on alcohol compatible surfaces.
Contact Time (Undiluted)
Precautions :
Maximum disinfection effect against Escherichia coil, Pseudomonas aerugnisa, Tuberculosis Staphylococcus aureus, Proteus Mirabilis, Mycobactericidal, and Candida albicans.