My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Freezers 15 Products available
  2. Laboratory Equipments 13 Products available
  3. Generators 7 Products available
  4. Lab Stirrer 6 Products available
  5. Hematology Analyzer 5 Products available
  6. Dryers 4 Products available
  7. X Ray Machine 4 Products available
  8. Biochemistry Analyzer 3 Products available
  9. Cupboard

    2 Products available
  10. Machines And Equipments

    2 Products available
  11. Others Products 52 Products available

Biochemistry Analyzer

Our Complete range of products are Fully Automated Bio-Chemistry Analyser, Fully Automated Randon Access Bio-Chemistry Analyser and Semi Automated Bio-Chemistry Analyser.

Fully Automated Bio-Chemistry Analyser

  • Dimension : 760mm x 560 mm x 456 mm {LXWXH}
  • Power supply : AC 220 V + - 22V, 50 Hz + - 1Hz
  • Power consumption : < 500 VA
  • Environmental temperature : 15 degree C ~ 30 degree C
  • Humidity : < 85 %
  • Water consumption : 5L/ hour
  • Weight : 90 Kg

NOVA 2200 Fully Automatic Bio-Chemistry Random Access Analyzers are high throughput and High Speed Auto Analyzers having throghput of 220 Tests/Hr and 440 Tests/Hour respectively.

Specification

> Throughput : 200 test / hour, up to 280 test/ hour with ISE (optional)> Test Mode : End point, kinectic, fixed time, Immuno assays.> Test Range : Clinical Biochemistry, Turbidmetry, ISE, Portain, Drug abuse> Test Setting : Programmable for single, multi combined, batch items tests> Parameter settings : Completed open for editing test parameters and calculate parameters

Sample System
Sample tray : 44 sample positions can be extended to 88 sample positioning for primary tubes, test tibes and various sample cups.Whole tray can be rempved and replaced. Any position can be aligned as the Emergnecy test position.Sample volume : 2 30 ul, step by 0.1 ulRetest : Dilutes and re test auotmatically when sample concentration beyond limitationSample probe : Liquid level detection and collision protectionProbe cleaning : Automatic washing for both inside and outside, carry over 3000 hoursWavelength : 9 interface filters : 340 nm, 405 nm, 450 nm, 505 nm, 546nm, 578nm, 620nm, 670nm, .Wavelenght accuracy : + - 2 nmAbsorbance range : 0.000 - 3.000 AbsResolution : 0.001 Abs

Calibration & Control

Calibration mode : Linear (one point and multi point) Logit - log 5 P, Exponnential, Polynomial, parabolaControl rules : Westgard multi rule, cumulative sum check, twin plot, 3 level s quality controlControl mode : Real tome, intra day & inter day QC

Operating Systems

Computer control : Windows 2000 systems or aboveData management : Large capacity for results, reaction curve be displayed, saved and printedInterface : RS 323 interface

View Complete Details

Fully Automated Randon Access Bio-Chemistry Analyser

  • Voltage AC 85 V ~ 26 V, 55 Hz +/- 8 Hz, Auto adaption according to the input voltage
  • Power < 350 VA
  • Weight 90Kg
  • Dimension 850mm x 650mm x 7067mm {L X H X H}

Features
> Discrete, random access, fullyu automated.
> 250 test / hours without ISE.
> STAT samples can be inserted at random.
> Unattached reagent & sample probe, liquid level detection collision protection.
> On board reagent cooling system

System Function

> Throughput : Up to 250 tests/hours (not including ISE test)> Test method : End-point, kinectic, fixed-time.> Test sequences : Discrete, random access, STAT can be inserted at any time. Test sequence can be sorted by samples or items> Spectrometer : Enclosed array of spectrometer and photodiodes, maintenance free.> Cuvette washing : Auto wash the cuvettes through 8 segments washing pipe and continuous use them (optional)> Reaction detect : Monitor 81 cuvettes reaction at the same time.> Photometric process : The interval time between two consecutive photometric points are exactly the same.> Pipeline system : Pressure auto released pumps and double filters to protect pumps and valves.> Gearing : Plastic gear leads lower noise and accuracy of positioning of moving parts.> Environmental resistance : Resistant from dust and water vapor.

Optical System
Light Source : 12 V, 20 W, Halogen lamp with lifetime more than 2000 hoursSpectrometer : Post spectrometer with arrayed and sealed filters, maintainsnce freeWavelenght : 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm.Absorbance range : 0 6

Reaction System
Cuvette : Permanent UV free glass cuvetteReaction Disc : Discal reaction disc with 81 disposable cuvettesReaction Volume : 150 ul 600 ulHeater : Solid and sealed heater leads temperature raise rapidly and steady and maintenance freeTemperature : 37 degree C + /- 1 degree C

Sample System

Sample Volume : 2 ul 300 ul, step by 0.1 ulSample Disc : 60 positions for primary tubes and secondary cupsReagent Volume : 20 ul 300 ul, step by 1 ulReagent Bottle : Particular raegent bottle without dead volumeReagent coooling : Continuous cooling systems according to teh principle of peltierProbe : Inner and outer walls are highly polished leads carry over < 0.1 % level detection and vertical and horizontal collision protectionStirrer : Paddle stirrer coated with Telfon, stir immediately after samplingWater Consume : Optimized item test sequence reinfirced washing process, lower the carry over avoid being clotted

Calibration / QC

Calibration Type : Single point linear, two point linear, multi points linear, logit - 4 P, Logit 5 p, S pline, Exponential 5P, Polynomial 5P, Auto choose the best fittest calibration curveQC type : Real time QC, day to day QCQC chart : L-j cumulative sum check, twin plotQC rule : Customized QC rule in order to adapt different items requirement

Operational Systems

Operational system : Vista, windows Xp, Wndows 2000Memory : Auto save and recover the resultsReport Format : Customized report formatStatus check : Real time check the working status of the analyzer

Power / Dimension
Voltage : AC 85 V 26 V, 55 Hz +/- 8 Hz, Auto adaption according to the input voltagePower : < 350 VADimension : 850mm x 650mm x 7067mm L X H X HNet Weight : 90Kg

View Complete Details

Semi Automated Bio-Chemistry Analyser

  • Test items 250
  • Flow cell quartz flow cell 32uL
  • Lamp PHILIP 6V 10W
  • Measurement range 0 ~ 5Abs
  • Resolution 0.001 Abs (display), 0.001 Abs (calculation)
  • Temperature control Peltier 37 ºC, 30ºC, 25ºC, 0.1ºC
  • Repeatability <1%

Semi Automated Bio-Chemistry Analyser

Specification :
> With both shipping and cuvette system> Resolution : 0.001 Abs (display), 0.001 Abs (calculation)> Temperature control : Peltier 37 C, 30C, 25C, 0.1C> Repeatability : Quality control for all test.> Statistic and print quality control parameters automatically wuth QC curves.> Program : Add or delete test items easily according to the condition, modify the test parameters.> Display dynamic curves at real time, visually react the process.> Dormant automatically for the lamp to proiong its lifespan> Input 8 standard curves at most in testing with multistandard method> Max reagent consumption : 500uL per sample

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us