Our Products
Cupboard
2 Products availableMachines And Equipments
2 Products availableOur Complete range of products are Fully Automated Bio-Chemistry Analyser, Fully Automated Randon Access Bio-Chemistry Analyser and Semi Automated Bio-Chemistry Analyser.
NOVA 2200 Fully Automatic Bio-Chemistry Random Access Analyzers are high throughput and High Speed Auto Analyzers having throghput of 220 Tests/Hr and 440 Tests/Hour respectively.
Specification > Throughput : 200 test / hour, up to 280 test/ hour with ISE (optional)> Test Mode : End point, kinectic, fixed time, Immuno assays.> Test Range : Clinical Biochemistry, Turbidmetry, ISE, Portain, Drug abuse> Test Setting : Programmable for single, multi combined, batch items tests> Parameter settings : Completed open for editing test parameters and calculate parameters Sample System Calibration & Control Calibration mode : Linear (one point and multi point) Logit - log 5 P, Exponnential, Polynomial, parabolaControl rules : Westgard multi rule, cumulative sum check, twin plot, 3 level s quality controlControl mode : Real tome, intra day & inter day QC Operating Systems Computer control : Windows 2000 systems or aboveData management : Large capacity for results, reaction curve be displayed, saved and printedInterface : RS 323 interface | ||
Features
> Discrete, random access, fullyu automated.
> 250 test / hours without ISE.
> STAT samples can be inserted at random.
> Unattached reagent & sample probe, liquid level detection collision protection.
> On board reagent cooling system
System Function
> Throughput : Up to 250 tests/hours (not including ISE test)> Test method : End-point, kinectic, fixed-time.> Test sequences : Discrete, random access, STAT can be inserted at any time. Test sequence can be sorted by samples or items> Spectrometer : Enclosed array of spectrometer and photodiodes, maintenance free.> Cuvette washing : Auto wash the cuvettes through 8 segments washing pipe and continuous use them (optional)> Reaction detect : Monitor 81 cuvettes reaction at the same time.> Photometric process : The interval time between two consecutive photometric points are exactly the same.> Pipeline system : Pressure auto released pumps and double filters to protect pumps and valves.> Gearing : Plastic gear leads lower noise and accuracy of positioning of moving parts.> Environmental resistance : Resistant from dust and water vapor.
Optical System
Light Source : 12 V, 20 W, Halogen lamp with lifetime more than 2000 hoursSpectrometer : Post spectrometer with arrayed and sealed filters, maintainsnce freeWavelenght : 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm.Absorbance range : 0 6
Reaction System
Cuvette : Permanent UV free glass cuvetteReaction Disc : Discal reaction disc with 81 disposable cuvettesReaction Volume : 150 ul 600 ulHeater : Solid and sealed heater leads temperature raise rapidly and steady and maintenance freeTemperature : 37 degree C + /- 1 degree C
Sample System
Sample Volume : 2 ul 300 ul, step by 0.1 ulSample Disc : 60 positions for primary tubes and secondary cupsReagent Volume : 20 ul 300 ul, step by 1 ulReagent Bottle : Particular raegent bottle without dead volumeReagent coooling : Continuous cooling systems according to teh principle of peltierProbe : Inner and outer walls are highly polished leads carry over < 0.1 % level detection and vertical and horizontal collision protectionStirrer : Paddle stirrer coated with Telfon, stir immediately after samplingWater Consume : Optimized item test sequence reinfirced washing process, lower the carry over avoid being clotted
Calibration / QC
Calibration Type : Single point linear, two point linear, multi points linear, logit - 4 P, Logit 5 p, S pline, Exponential 5P, Polynomial 5P, Auto choose the best fittest calibration curveQC type : Real time QC, day to day QCQC chart : L-j cumulative sum check, twin plotQC rule : Customized QC rule in order to adapt different items requirement
Operational Systems
Operational system : Vista, windows Xp, Wndows 2000Memory : Auto save and recover the resultsReport Format : Customized report formatStatus check : Real time check the working status of the analyzer
Power / Dimension
Voltage : AC 85 V 26 V, 55 Hz +/- 8 Hz, Auto adaption according to the input voltagePower : < 350 VADimension : 850mm x 650mm x 7067mm L X H X HNet Weight : 90Kg
Semi Automated Bio-Chemistry Analyser
Specification :
> With both shipping and cuvette system> Resolution : 0.001 Abs (display), 0.001 Abs (calculation)> Temperature control : Peltier 37 C, 30C, 25C, 0.1C> Repeatability : Quality control for all test.> Statistic and print quality control parameters automatically wuth QC curves.> Program : Add or delete test items easily according to the condition, modify the test parameters.> Display dynamic curves at real time, visually react the process.> Dormant automatically for the lamp to proiong its lifespan> Input 8 standard curves at most in testing with multistandard method> Max reagent consumption : 500uL per sample